Loading...
HomeMy WebLinkAbout20090123Kopczynski Direct.pdfDAVID J. MEYER VICE PRESIDENT AN CHIEF COUNSEL OF REGULATORY & GOVERNENTAL AFFAIRS AVISTA CORPORATION P.O. BOX 3727 1411 EAST MISSION AVENUE SPOKAE i WASHINGTON 99220 - 3 727TELEPHONE: (509) 495-4316FACSIMILE: (509) 495-8851 l'C""~ I l"Rt: ::1," :.i 1ßß9 J~N 23 PM \2: 42 BEFORE THE IDAHO PUBLIC UTILITIES COMMISSION IN THE MATTER OF THE APPLICATION OF AVISTA CORPORATION FOR THE AUTHORITY TO INCREASE ITS RATES AND CHARGES FOR ELECTRIC AND NATURAL GAS SERVICE TO ELECTRIC AN NATURA GAS CUSTOMERS IN THE STATE OF IDAHO CASE NO. AVU-E-09-01 CASE NO. AVU-G-09-01 DIRECT TESTIMONY OF DON F. KOPCZYNSKI FOR AVISTA CORPORATION (ELECTRIC AN NATURAL GAS) 1 2 I.INTRODUCTION Q.Please state your name, employer and business 3 address. 4 A.My name is Don F. Kopczynski and I am employed as 5 the vice President of Transmission and Distribution 6 Operations for Avista Utilities, at 1411 East Mission 7 Avenue, Spokane, Washington. 8 Q.Would you briefly describe your educational 9 background and professional experience? 10 A.Yes.Prior to joining the Company in 1979, I 11 earned a Bachelor of Science Degree in Engineering from the 12 University of Idaho.I have also earned a Mas ter 's Degree 13 in Management from Washington State University and a 14 Master's Degree in Organizational Leadership from Gonzaga 15 16 University.Over the past 30 years I have spent approximately 16 years in Energy Delivery,managing 17 Engineering, various aspects of Operations, and Customer Service.In addition, I spent three years managing the18 19 20 Energy Resources Department,including Power Supply, Generation and Production, and Natural Gas Supply.More 21 recently, I worked in the areas of Corporate business 22 analysis and development, and served in a variety of 23 leadership roles in subsidiary operations for Avista Corp. 24 I was appointed General Manager of Energy Delivery in 2003 25 and Vice President in 2004.I serve on several boards, Kopczynski, Di 1 Avista Corporation 1 including the Eastern washington University Electrical 2 Engineering and Computer Science Advisory Board, Washington 3 State Electrical Board, and the washington State university 4 Engineering Advisory Board. 5 6 Q.What is the scope of your testimony? A.i will provide an overview of the Company's 7 electric and natural gas energy delivery facilities and 8 operations. i will also explain some of our recent efforts 9 to increase efficiency and improve customer service, such 10 as the newly formatted website and outsourcing of the bill 11 print and mail service, as well as sumarize Avista' s 12 customer service programs in Idaho.A table of the 13 contents for my testimony is as follows: 14 15 16 17 18 19 20 21 22 23 24 i.II.Introduction Overview of Avista' s Energy Delivery Operations System Improvements & Efficiencies Information Services Support Cus tomer Support Programs Page Page 1 Page 3 Page 6 Page 9 Page 10 Description III. IV. V. Q.Are you sponsoring any exhibits in this 25 proceeding? 26 27 28 A.Yes.I am sponsoring Exhibit No.7, Schedules 1 and 2.Schedule 1 details the system improvements and efficiencies the Company has undertaken.Schedule 2 shows Kopczynski, Di 2 Avista Corporation 1 the detailed usage and numer of customers for each 2 customer class. These exhibits were prepared under my 3 direction. 4 5 6 7 II. OVERVIEW OF AVISTA'S ENERGY DELIVERY SERVICE Q.Please provide an overview of the customers. 8 served by Avista utilities in Idaho. 9 A.Of the Company's 352,423 electric and 309,912 10 natural gas customers (September 30, 2008), 120,972 and 11 72,326,respectively,were Idaho cus tomers .Avista's 12 largest electric customer in Idaho is the Potlatch 13 Corporation's Lewiston facility, with an annual usage of 14 approximately 898 million kWh. 15 Q.Please describe Avista utilities' Idaho electric 16 and natural gas utility operat~ons. 17 A.The Company serves the Idaho counties of 18 Benewah, Bonner, Boundary, Clearwater, Idaho, Kootenai, 19 Latah, Lewis, Nez Perce, and Shoshone.Lumer and wood 20 products manufacturing is the dominant industry in our 21 Idaho service area. Approximately 34% of 2008 Idaho 22 electric retail usage was from residential customers, with 23 29% from commercial, 35% from industrial customers, and 2% 24 from pumping customers. Approximately 48% of natural gas 25 retail revenues were from residential customers, and 16% Kopczynski, Di 3 Avista Corporation 1 from commercial and 37% from industrial and transportation 2 customers. The Company has seven transportation customers 3 in Idaho. 4 As detailed in the Company's 2007 electric integrated 5 Resource Plan, Avista expected retail electric sales 6 growth to average 2.3% annually for the next ten years and 7 2.0% over the next twenty years in Avista's service 8 territory, primarily due to increased population and 9 bus iness growth. The Company is currently in the process 10 of preparing its 2009 IRP, and the impacts of the current 11 economic climate will be reflected in that document to be 12 filed with the Commission in August 2009. 13 Also, based on Avista' s 2007 Natural Gas Integrated 14 Resource Plan, in Idaho the numer of customers were 15 proj ected to increase at an average annual rate of 3.0%, 16 wi th demand also growing at 3.0% per year.As with the 17 electric IRP, the impacts of the current economic climate 18 will be addressed in the Company's 2009 natural gas IRP 19 that will be filed with this Commission in December 2009. 20 Q.Please describe the Company's electric and 21 natural gas delivery facilities. 22 A.Avista utilities operates a vertically-integrated 23 electric system.In addition to the hydroelectric and 24 thermal generating resources described by Company witness 25 Mr. Storro, the Company has approximately 4,052 miles of Kopczynski, Di 4 Avista Corporation 1 lines in the following classes in Idaho: 286 miles of 230 2 kV transmission, 604 miles of 115 kV transmission, and 3 3,162 miles of sub-transmission and distribution line at a 4 5 variety of voltages.Avista also has 928 miles of distribution underground cable;the predominant 6 distribution voltage is 13.2 kV. Avista owns and maintains 7 1876 miles of natural gas pipelines (excluding services) in 8 the state of Idaho of which 560 miles are steel and 1316 9 10 miles are polyethylene.All of these pipelines are distribution,not transmission,operating at various 11 maximum allowable operating pressures (MAOPs) from 60 psig 12 to 720 psig.Avista has 69,337 natural gas service lines 13 in Idaho. 14 Q.Please describe the Company's operations centers 15 that support electric and gas customers in Idaho. 16 A.The Company has construction offices in 17 Grangeville, Orofino, Lewiston-Clarkston, Moscow-pullman, 18 Kellogg, St. Maries, Coeur d'Alene, Sandpoint and Bonner's 19 Ferry, and customer contact center operations in Lewiston 20 and Coeur d'Alene. Avista's four customer contact centers 21 in Coeur d' Alene, Lewiston, Spokane, and Medford, Oregon 22 are networked, allowing the full pool of regular and part- 23 time employees to respond to customer calls in all 24 jurisdictions. Kopczynski, Di 5 Avista Corporation 1 Q.What construction an maintenance programs does 2 the Company have in place to maintain gas and electric 3 facilities? 4 A.Avista Utilities utilizes Company seasonal and 5 regular crews for gas and electric construction, including 6 new and reconstructed lines, damage repair, and connecting 7 new cus tomers .The Company employs contract crews and 8 temporary and part-time employees to meet customer needs 9 during the peak construction season.The Company also has 10 several maintenance programs to maintain the reliability of 11 our electric and gas infrastructure. On the electric side, 12 this includes the Company's asset management program 13 (including wood pole inspection and replacement) , 14 vegetation managemen t ,electric transmission line 15 inspection and reconstruction.Company witness Mr. Kinney 16 discusses this program in more detail. Regarding natural 17 gas operations, ongoing maintenance focuses on valve and 18 regulator stations, atmospheric corrosion protection, and 19 leak surveys. 20 21 III. SYSTEM IMPROVES AN EFFICIENCIES 22 Q.Has the Company looked at undertaking additional 23 measures to either reduce costs or increase customer 24 service levels? Kopczynski, Di 6 Avista Corporation 1 A.Yes. Avista utilities has undertaken a numer of 2 improvements and efficiency initiatives throughout our 3 service area that are focused on either increasing customer 4 service and satisfaction, or increasing productivity and 5 reducing operating costs.We believe these measures have 6 served to mitigate the impact on customers of the proposed 7 rate increase. 8 Q.Please explain the system improvement measures 9 that Avista has implemented in Idaho. 10 A.Some of the recent improvements that the Company 11 has implemented are as follows: 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 . We have updated our Integrated voice Response system to provide more assistance to our customers to interact with our company. . Our redesigned website - AvistaUtilities. com provides customers easy access to their account where they can review and pay their bill; it also provides current companyinformation. . The Every Little Bit Enerov Efficiency Camoaian - We are able to show customers that "every little bit" does add up and can make a difference in their energy usage. . Evaluating transmission and distribution system efficiencies. By tracking the reduction in losses across our transmission and distribution system, Avista can verify the life cycle cost benefit of the system improvement. . Avista has been able to complete numerous small energy efficiency projects that have resulted in energy conservation at company offices and service centers. Kopczynski, Di 7 Avista Corporation 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 . We outsourced our bill orint and mailing operations which now meets all requirements for disaster recovery which ensures timely delivery of customer information and customerbills. . Avista is working through collaborative efforts with the City of Spokane in a pilot program to coordinate design locates as part of the City's construction design process. . Helped formulate the Spokane RegionalInfrastructure Efficiencv Plan. The Joint utilities Coordination Council has resulted in greater coordination and efficiencies across the entire Spokane region. . Craft Traininq this new learning network gives us a delivery and a record-keeping system that allows the Company to plan, schedule and document our training programs and requirements in a more efficient way. . Implemented a new Asset Manaqement Proqram. This new software allows detailed analysis of the impacts of increased or decreased reliability based on system configuration and component reliability. . The Company recently deployed a customsoftware application which provides the Company wi th the abi 1 i ty to manaqe the scheduling of planned outages for transmission lines and line segments. This improvement tothe system has reduced operator time, streamlined the scheduling process, andreduces errors. . As of late 2008, all qas and electric crew callouts in all jurisdictions will be handled by the ARCOS Rostermonster system. The expanded capabilities of ARCOS will allow us to callout personnel from multiple lines with less delay, thereby improving restoration time for after-hour customer outages. . The Company has recently started an evaluation of the Fleet Department. Company employees have identified process improvements in Kopczynski, Di 8 Avista Corporation 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 addi tion to technological upgrades that will benefit and modernize its fleet department. . We have implemented a new Outage Management System to help minimize the restoration time of outages on our system. . Our Mobile Dispatch Program reduces the time it takes for the Company to process customers' natural gas orders, and provide service. Wealso made outage information available to customers on the Company's website athttp://ww.avistautilities.com/safety/outages/ pages / defaul t . aspx. These programs are detailed further in Exhibit No.7, 18 and are examples of the extensive efforts of Avista to 19 identify and implement efficiency measures and/or 20 productivity while continuing to provide quality service to 21 cus tomers . 22 23 24 iv. INFORMTION SERVICES SUPPORT Q.Please explain what expenditures are directly 25 related to the Company's Informtion Services being 26 captured in this case. 27 A.The expendi tures that the Company has pro formed 28 in this case include the administrative and general (A&G) 29 expenses associated with incremental known and measureable 30 changes for labor and non-labor informational services 31 costs planned for 2009 above the test period, which total 32 $2.6 million on a system basis (Idaho's share is Kopczynski, Di 9 Avista Corporation 1 approximately $ .7 million). They are related to the 2 following: 3 1) addi tional labor dollars required to support 4 applications utilized by the Company in recent years, such 5 as the mobile dispatch and outage management applications, 6 improved web application support, and additional security 7 and compliance requirements; and 8 2) additional non-labor dollars required for hosting 9 fees, application fees, software maintenance and license 10 fees, and new and replacement software and hardware for 11 business applications.Company witness Ms.Andrews 12 includes these additional expenses in her pro forma 13 adjustments. 14 15 16 v.CUSTOMER SUPPORT PROGRAS Q.Please explain the customer support programs 17 that Avista provides for its customers in Idaho. 18 A.Avista Utilities actively participated in the 19 energy affordabili ty workshops in Case No. GNR-U-08-01. In 20 that case, workshop participants explored ways to address 21 energy affordability and the ability of customers to pay 22 energy bills. Staff's comments in the above mentioned case, 23 among other issues, recommended that the Commission support 24 legislation to allow it to adopt a LIRAP program. The 25 Company continues to advocate the implementation of a Low Kopczynski, Di 10 Avista Corporation 1 Income Rate Assistant Program (LIRAP)for its Idaho 2 cus tomers . 3 Avista Utilities offers a numer of programs for its 4 Idaho customers, such as energy efficiency programs, 5 Project Share for emergency assistance to customers, a 6 Customer Assistance Referral and Evaluation Service (CARES) 7 program, senior programs, level pay plans, and payment 8 arrangements.Some of these programs will serve to 9 mitigate the impact on customers of the proposed rate 10 increase. 11 Q.Please describe Avista utilities' demnd-side 12 management (DSM), or energy efficiency, programs. 13 A.The Company's innovative Energy Efficiency 14 Tariff Rider is celebrating its fourteenth anniversary. 15 The tariff rider, the country's first distribution charge 16 to fund DSM and now replicated in many other states, has 17 provided consistent funding for the delivery of energy 18 efficiency services. Company witness Mr. Folsom provides 19 more detail about Avista Utili ties' energy efficiency 20 services. 21 Q.Please describe the recent resul ts of the 22 Company's Project Share efforts? 23 A.Project Share is a community-funded program 24 Avista sponsors to provide one-time emergency support to 25 families in the Company's region. Avista customers and Kopczynski, Di 11 Avista Corporation 1 shareholders help support the fund with voluntary 2 contributions that are distributed through local community 3 action agencies to customers in need.Grants are 4 available to those in need without regard to their heating 5 source. As of November 2008 Avista Utili ties' customers 6 donated $219,346 on a system basis, of which $67,468 was 7 directed to Idaho Community Action Agencies. In addition, 8 the Company contributed $74,781 to Idaho customers in 9 2008. 10 11 Q.Does the Company offer a bill-averaging program? A.Yes. Comfort Level Billing helps smooth out the 12 seasonal highs and lows of customers' energy usage and 13 provides the customer the option to pay the same bill 14 amount each month of the year.This allows customers to 15 more easily budget for energy bills and avoid higher winter bills.This program has been well-received by16 17 participating customers.Over 16,684, or 12%, of Idaho 18 electric and natural gas customers are on Comfort Level 19 Billing. 20 In addition,the Company's Contact Center 21 Representatives work with customers to set up payment 22 arrangements to pay energy bills.In 2008, 32,228 Idaho 23 customers were provided with over 85,711 such payment 24 arrangements. 25 Kopczynski, Di 12 Avista Corporation 1 2 Q.Please sumrize Avista' s CARS program. A.In Idaho, Avista is currently working with over 3 1,255 special needs customers in the CARES program. 4 Specially-trained representatives provide referrals to area 5 agencies and churches for customers with special needs for 6 help with housing, utilities, medical assistance, etc. In 7 its comments in Case No. GNR-U-08-01, the I PUC Staff 8 "recommends that all utilities implement case management 9 programs if they have not already done so." 10 Q.Have these programs helped mitigate the impact 11 on customers in need? 12 A.Yes. Through these programs, the Company works 13 to build lasting ways to ease the burden of energy costs 14 for customers that have the greatest need. 15 In the 2007/2008 heating season,10,125 Idaho 16 customers received $2,814,506 in various forms of energy 17 assistance (Federal LIHEAP program, Project Share, and 18 local community funds). On September 30, 2008, President 19 Bush signed legislation that provides $5.1 billion for the 20 Low Income Home Energy Assistance Program (LIHEAP) for the 21 2008/2009 heating season. This increased funding will 22 serve an additional 2 million households and raise the 23 average grant from $355 to $550 and also allows states to 24 carryover any funds remaining to next years heating 25 season. Idaho's share of the LIHEAP funding was increased Kopczynski, Di 13 Avista Corporation 1 from $12,376,000 to $26,969,000. This bill also provides 2 increased funding for weatherization assistance programs. 3 These programs and the partnerships we have formed have 4 been invaluable to customers who often have nowhere else 5 to go for help. 6 Q.Does this conclude your pre-filed direct 7 testimony? 8 A.Yes. Kopczynski, Di 14 Avista Corporation DAVID J. MEYER RECEI D VICE PRESIDENT AN CHIEF COUNSEL OF REGULATORY & GOVERNENTAL AFFAIRs2û09 JAN 23 PH 12: 42 AVISTA CORPORATION P . O. BOX 3727 1411 EAST MISSION AVENE SPOKAE, WASHINGTON 99220 - 3 727 TELEPHONE: (509) 495-4316 FACSIMILE: (509) 495-8851 BEFORE THE IDAHO PUBLIC UTILITIES COMMISSION IN THE MATTER OF THE APPLICATION ) CASE NO. AVU-E-09-01 OF AVISTA CORPORATION FOR THE ) CASE NO. AVU-G-09-01 AUTHORITY TO INCREASE ITS RATES ) AN CHARGES FOR ELECTRIC AN ) NATURA GAS SERVICE TO ELECTRIC ) EXHIBIT NO. 7 AN NATURAL GAS CUSTOMERS IN THE )STATE OF IDAHO ) DON F. KOPCZYNSKI ) FOR AVISTA CORPORATION (ELECTRIC AN NATURA GAS) 1 SYSTEM IMPROVENTS, EFFICIENCIES & PRODUCTIVITY MESURS 2 3 Avista Utilities is continually evaluating potential 4 system improvements,additional efficiencies and 5 productivity measures.The Company has undertaken a 6 numer of improvements throughout our utility that are 7 focused on either increasing customer service and 8 satisfaction, or reducing operating costs. Some examples 9 of these initiatives are as follows: 10 11 A. Integrated voice Response System (IVR) 12 B. Website Redesign 13 C. Every Little Bit Energy Efficiency Campaign 14 D. Transmission and Distribution System Efficiencies 15 E. Onsite Energy Efficiency Projects 16 F. Facilities and Janitorial Services 17 G. Bill Print and Mail Service Outsource 18 H. Design Locates 19 I. Regional Infrastructure Efficiency Plan 20 J. Craft Training 21 K. Asset Management 22 L. Transmission Outage Scheduling 23 M. ARCOS Rostermonster 24 N. Fleet Optimization 25 O. Outage Management 26 P. Mobile Dispatch 27 28 29 Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 1 of 15 1 A.Interactive voice Response System (IVR) 2 Avista i s Interactive voice Response System (IVR) has been 3 in service since Novemer 1997.Currently, nearly 40% of 4 customer calls are handled by the IVR for self-service, 5 which includes outage reporting and messaging, accepting 6 payments, making payment arrangements, hearing account 7 information and other information such as pay station, and 8 heating assistance locations. In 2008, the IVR was updated 9 to allow customers to use the system to conduct other 10 business, such as electronic payments (over 123,406 in 11 2008) and obtaining account balances (over 144,526 in 2008) 12 and payment arrangements (over 80,471 in 2008). 13 Four years ago, Nortel (manufacturer of Avista's IVR) 14 announced the end of the operating system. Therefore, the 15 technology is now obsolete and new functionality will be 16 difficult or impossible to add to the current platform. 17 The hardware was over 10 years old.Avista needs to 18 refresh this technology as a way to guarantee the continued 19 ability for customers to self-serve.New functionality 20 includes the ability for customers to sign up for Comfort 21 Level Billing (CLB) and Automated Payment Service (APS) 22 along with Restoration Call Backs to customers. 23 The Company has selected Intervoice, a leading IVR 24 manufacturer on a new platform that will offer customers 25 additional functionality, and will use Voice Recognition as 26 the main interface between customers and machine.Touch- Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 2 of 15 1 tone entry will still be available, however.The new IVR 2 system is currently scheduled to be available for customers 3 by the third quarter of 2009. This system will continue to 4 allow us to have fewer customer service representatives on 5 staff ,which results in lower labor costs. 6 B.Web Site Redesign - Web Redesign was a project 7 launched in July 2005 to rebuild the Avista utilities 8 website.This proj ect included visual design and user 9 interface, customer transaction automation and technology 10 platform reliability, scalability, flexibility.The 11 Company's primary goal is to achieve a 10% reduction in the 12 call center's total call volume while increasing customer 13 satisfaction.Avista transformed the website to provide 14 meaningful and timely information with powerful self- 15 service tools that will help customers make informed energy 16 management choices. 17 c.Every Little Bit Energy Efficiency campaign 18 The Company understands that rising energy costs have put 19 added pressure on customers. With this in mind, Avista is 20 committed to increasing customer and community awareness 21 about wise energy use.Promoting the wise and efficient 22 use of energy resources has taken on added importance 23 locally, nationally and globally, and it is our goal to 24 build customer awareness around energy usage, energy 25 efficiency practices, and to direct them to the resources 26 and tools we have available to assist them. To ensure we Exhibit No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 3 of 15 1 did this appropriately,Avista conducted a baseline 2 research study to determine how we could best affect 3 customer usage habits. 4 Armed with this data, Avista created the "Every Little 5 Bit" campaign. We are able to show customers that "every 6 little bit" does add up and can make a difference in their 7 energy usage. We focused this initial campaign on low-cost 8 and no-cost measures, with information on rebates and 9 energy efficiency. The initial campaign,launched in 10 September 2007 is the beginning of a long-term effort aimed 11 at assisting customers to use energy more efficiency. This 12 project is funded under the Company's DSM tariff rider. 13 D.Transmission and Distribution System Efficiencies 14 Avista is developing innovative programs to locate and 15 quantify energy losses across our transmission and 16 distribution system. The efficiencies programs will review 17 the energy savings associated with a wide range of system 18 improvements from feeder balancing to conservation voltage 19 reduction. The energy savings associated with each program 20 will be assemled into an energy portfolio identifying the 21 relative cost per kWh of savings. This portfolio will be 22 used to prioritize proj ects in order to focus improvements 23 on programs with the greatest benefit. 24 Another consideration for the efficiencies programs is 25 the development of an implementation strategy which bundles 26 efficiencies projects with operational programs. The Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 4 of 15 1 efficiencies program to replace older less efficient 2 transformers with new more efficient transformers may be 3 bundled with the redesign or replacement of secondary 4 districts since a strong correlation exists between old 5 transformers feeding large secondary districts.By 6 combining these two programs, Avista can accomplish the 7 following two program goals: 1) Coordinate crew time "touch 8 the pole just once" and 2) optimize energy savings, 9 eliminate a source of outages, thus improving reliability. 10 Finally, as efficiencies programs are implemented, 11 Avista is interested in achieving energy savings across its 12 system. Consequently, Avista is establishing work processes 13 and information systems to track these savings when 14 programs are implemented. For example, to account for the 15 energy savings from the replacement of an old vintage 16 transformer with a new transformer, the tracking system 17 will capture the replacement date, the relative transformer 18 losses, and the load profile. By tracking the reduction in 19 losses across our transmission and distribution system, 20 Avista can verify the life cycle cost benefit of the system 21 improvement. 22 E.Onsite Energy Efficiency projects - Avista has 23 completed numerous small energy efficiency projects that 24 have resulted in energy conservation at company offices and 25 service centers. Following are some examples: 26 .Passenger elevator upgrade Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 5 of 15 1 .Service elevator upgrade 2 .Appliance replacement 3 .Compressed air sys tem 4 .HVAC system control valve 5 6 . Various lighting improvement projects (LED, exit signs, etc.) 7 · HVAC controls - Coeur d' Alene Service Center 8 · Motors and Controls 9 A total of 28 projects were completed since 2005. Total 10 kWh saved are 3,197,594 and total therms saved are 47,828. 11 12 In 2007, Avista initiated a multi-year HVAC renovation 13 at its headquarters facilities in Spokane. The project is 14 needed to replace equipment that is now 50 years old. 15 Present estimates indicate cost savings of $432,000 per 16 year in energy use, a 36% reduction in energy costs. The 17 proj ect will also achieve asbestos abatement and life 18 safety (fire sprinkler)additions.Project will 19 tentatively be completed in 2013. 20 F.Facilities and Janitorial Services In 1993, 21 Avista converted from an "in house" bargaining unit 22 janitorial crew at the Spokane facility, to a contract 23 crew.The initial savings based on 1993 rates was 24 approximately $134,000 per year. 25 In 2006, as a result of union negotiations, the 26 company was able to switch to a non-bargaining unit Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 6 of 15 1 contract crew providing an additional $51,000 per year 2 savings. 3 G.Bill Print and Mail Service out source - Avista' s 4 bill printing and mail services were outsourced to Regulus, 5 the second largest first class mailer in the United States. 6 The project objectives were to move bill printing, 7 inserting and mailing offsi te and to leverage core 8 competencies of the provider.It will also serve to meet 9 disaster recovery requirements, ensure daily print volume 10 flexibility and scalability, reduce costs for bill print, 11 inserting and mailing, and serve to maximize technology. 12 Avista's primary objective was to achieve disaster 13 recovery. Avista needed a back-up system to ensure day-to- 14 day business operations. Furthermore, customers expect to 15 receive their billing statements in a timely manner in 16 order to avoid delayed payments, unintended collections and 17 shut-offs. Through a third-party provider, Avista has 18 available five alternative printing sites and at each site 19 there are redundant systems for equipment breakdowns. 20 Avista has invested in dedicated data lines to both the 21 primary print site in Napa, CA, and to the alternative site 22 in Charlotte, SC. In the event that those lines were not 23 available, Avista would access lines at the vendors other 24 sites. 25 Avista has obtained USPS postage expertise to maximize 26 its postage costs. Under the Regulus contract, Avista Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 7 of 15 1 expects to pay approximately 12 cents per piece. That is 2 down from 17 cents under the former provider. The 12 cents 3 per piece does not include the capital costs to implement 4 the proj ect .Furthermore, the Vendor has USPS postal 5 personnel onsite to ensure that the mailings meet USPS 6 requirements and can be delivered in the fastest means 7 possible. 8 As part of the project, Avista redesigned its bills, 9 letters and notices making them easier-to-read and 10 understand, thereby reducing call center call volumes. The 11 bill also provides flexible space for providing improved 12 communications to customers. 13 14 H.Design Locates Avista is working through 15 collaborative efforts with the City of Spokane in a pilot 16 program to coordinate design locates as part of the City's 17 construction design process. The goal of this pilot is to 18 have utility locators provide locates for the Company's 19 existing facilities before the city projects are designed 20 in order to avoid potentially costly facility relocation. 21 Cost savings will be measured throughout the construction 22 year.The measurements will be used to evaluate whether 23 the process should be extended in conjunction with other 24 jurisdictions throughout the Avista service territory. 25 I.Regional Infrastructure Efficiency Plan 26 Spokane's Joint Utili ties Coordination Council was formed Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 8 of 15 1 to bring together regional municipali ties,utility 2 companies, telecommunication providers, sewer, water and 3 railroad to coordinate construction activities on an annual 4 basis.Avista, in partnership with the City of Spokane, 5 hosts this meeting every February, just prior to the 6 beginning of the construction project season. 7 Municipalities and utilities share their project plans and 8 schedules so as to increase the coordination and mitigate 9 the risk of unknown proj ects .The Joint Utilities 10 Coordination Council has resulted in greater coordination 11 and efficiencies across the entire Spokane region. 12 J.Craft Training The craft training department 13 has developed over 50 different on-line training classes 14 for our natural gas, electriè and generation apprentice and 15 qualification programs.In 2007,the natural gas 16 department alone was able to cut a full day from the annual 17 natural gas refresher training for 250 employees. The new 18 learning network also gives us a delivery and record 19 keeping system that allows the Company to plan, schedule 20 and document our training programs and requirements. 21 K.Asset Management Program As described by Mr. 22 Kinney, Avista has assigned two full-time engineers to the 23 formal Asset Management program.These individuals are 24 responsible for gathering information, prioritizing work 25 and executing efforts to best meet the Asset Management 26 mission.The engineers utilize a statistical Reliability Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 9 of 15 1 Centered Maintenance (RCM) software package to analyze 2 data.This software allows detailed analysis of the 3 impacts of increased or decreased reliability based on 4 system configuration and component reliability. 5 L.Transmission outage Scheduling - Avista recently 6 deployed a custom software application which provides the 7 Company with the ability to manage the scheduling of 8 planned outages for transmission lines and line segments. 9 Previously, transmission outages were requested via phone 10 or email and were tracked via a spreadsheet. Requests for 11 outages can now be submitted electronically via a web page, 12 which can then be either approved or rejected by the system 13 administrators. This improvement to the system has reduced 14 operator time, streamlined the scheduling process, and 15 ameliorates any errors. 16 M.ARCOS Roster.onster - Previously, after-hour crew 17 callouts were conducted on a one-on-one basis. As of late 18 2008,all gas and electric crew callouts in all 19 jurisdictions will be handled by the ARCOS Rostermonster 20 system.The expanded capabilities of ARCOS will allow us 21 to callout personnel from multiple lines with less delay, 22 thereby improving restoration time for after hour customer 23 outages. 24 N.Fleet Optimization - The Company recently started 25 an evaluation of the Fleet Department.Company employees 26 believe process improvements and technological upgrades Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 10 of 15 1 would increase productivity and modernize its fleet 2 departmen t .As part of the analysis, three areas of 3 fleet's business are being evaluated: service work, repair 4 work, and compliance/DOT work.Based on the results of 5 this analysis, we believe process reorganization and 6 scheduling efficiencies could be achieved through 7 specialized fleet software.The outcome of the project 8 should reflect a scheduling system and electronic filing 9 system, as well as determine the appropriate level of 10 staffing of mechanics and clerical staff. 11 o. OUtage Management Avista's Outage Management 12 System is an application utilizing the Company's Geographic 13 Information System (GIS mapping system).It allows 14 Avista' s distribution facilities to be linked to individual 15 customer service points in a computer based model.The 16 connectivity within the model allows for predictive 17 analysis tools to determine outage areas, affected system 18 devices and customers experiencing an outage. 19 Customers can report outages quickly by calling 20 Avista' scontact center or speaking to the Company's IVR. 21 All customer calls are plotted in the GIS mapping system 22 and tied to outage incidents, dramatically reducing the 23 chance they would be missed or forgot ten.Prediction of 24 the probable outage device allows all commonly affected 25 customers to be associated with an incident tied to the 26 outage device,dramatically reducing the numer of Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 11 of 15 1 incidents that must be managed by the dispatcher. Quick 2 identification of affected customers reduces outage time. 3 Customer outages are quickly identified geographically 4 through the GIS mapping system. Crews and other resources 5 can be assigned and managed at the incident level and can 6 be dispatched directly to the problem, reducing the outage 7 time. Accurate outage data is collected for all incidents 8 providing feedback to improve reliabili ty.Outage 9 statistics such as CAIDI and SAIFI are gathered in real 10 time to indicate the severity of maj or events and assist in 11 resource planning. The system is also capable of handling 12 customer callbacks to validate restoration has been 13 successful. 14 The GIS model provides the data necessary to analyze 15 system characteristics for system planning studies which 16 dictate how system modifications will proceed.Planning 17 models are now able to represent current system 18 configurations whereas in the past it would be easy for the 19 models to become badly out-of-date, due to the large manual 20 effort required to keep them current.System planners and 21 engineers now spend the majority of their time planning 22 instead of managing paper maps and re-creating computer 23 models. 24 The Mobile Dispatch implementation relies on the GIS 25 system to provide accurate representations of existing 26 facility and land features.Facility and customer Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 12 of 15 1 information is provided for routing and facility 2 identification.Documentation is provided by automated 3 updating of the GIS model from the field which eliminates 4 back office labor for map updates and insures currency of 5 the data. 6 Finally, the very sophisticated GIS connectivity model 7 gives Avista a distinct advantage by providing the 8 necessary foundation for the deployment of Smart Grid 9 technologies in the near or long term future. 10 P.Mobile Dispatch In June 2006,the 11 implementation of wireless laptop computers with mobile 12 maps (Mobile Dispatch) was deployed to all Avista natural 13 gas servicemen.Mobile Dispatch automatically dispatches 14 work orders to Avista servicemen throughout the day through 15 wireless technology to laptop computers mounted in Avista 16 service trucks.Prior to Mobile Dispatch, orders were 17 created in Avista' s work management system and printed at 18 the local construction offices.Employees in each office 19 would sort, assign and dispatch (via phone, pager, fax or 20 in person) orders each morning. The field employees would 21 work with the orders and call in the completed work 22 periodically throughout the day or simply turn-in the stack 23 of completed orders at the end of the day.The completed 24 orders were manually completed by employees who entered the 25 information regarding the order back into the work 26 management system. Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. KOpczynski, Avista Schedule 1, page 13 of 15 1 The paper processes made it nearly impossible to track 2 the status of individual orders and fieldworkers throughout 3 each day.It was also very difficult for the Dispatchers 4 to keep up with the volume of paper being sent out each 5 morning, changes to the orders that occurred during the 6 day, and completed orders returned at the end of the shift. 7 Mobile Dispatch has automated the order creation, 8 modification and completion process.With the new 9 technology, orders are created in the work management 10 system and are automatically dispatched to the correct 11 field worker based on the order's Latitude/Longitude 12 position and the person assigned to work orders in that 13 area. Once a field employee has been identified, the order 14 is sent through wireless technology to the laptop computer 15 mounted in Avista' s service truck.The order is then 16 reviewed by the employee for specific information needed to 17 complete the work. The order status is transmitted back to 18 the dispatch center, as the employee indicates they are en 19 route, on-site, and/or have completed the work. The 20 completed order is transmitted back to the work management 21 system where it is closed automatically. 22 Dispatchers have complete information for each order 23 and a field employee's status.They have the ability to 24 manage and redistribute work by simply dragging and 25 dropping orders from one field employee to another. The Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 14 of 15 1 orders instantly move from the originally-assigned laptop 2 to the newly-assigned laptop. Exhibi t No. 7 Case No. AVU-E-09-01 & AVU-G-09-01 D. Kopczynski, Avista Schedule 1, page 15 of 15 Customer Usage State of Idaho - Electric & Gas As of September 30, 2008 Electric kwh ScJiedule No. of Customers (OOOs)% of Total kwh Residential Sch. 1 99,073 1,181,158 33.7% General Sch. 11 & 12 19,005 325,696 9.3% Lge. General Sch. 21&22 1,452 704,569 20.1% Ex. Lge. General Sch. 25 13 1,219,378 34.8% Pumping Sch. 31&32 1,305 58,648 1.7% Street & Area Lights 124 13,747 0.4% 120,972 3,503,196 100% Natural Gas Therms Schedule No. of Customers (OOOs)% of Total Therms General Service 101 71,472 58,739 48% Lg. Genera Service 111/112 846 18,826 15% Interrptible Service 131/132 1 423 0% Transportation Service & Other 7 45,409 37% 72,326 123,397 100.00% Exhbit NO.7 Case No. A VU-E-09-01 and AVU-G-09-01 D. Kopczyski, A vista Schedule 2, p. 1 of 1