Loading...
HomeMy WebLinkAbout20200302Final Approved Tariffs.pdfRECElVED ROCKY MOUNTAIN on ,.Joelle R.Steward ERP f U.0 C i 2Vice President,Regulation 1407 West North Temple,Suite 330ADIVISIONOFPACIFICORPSaltLakeCity,UT 84116 February 21,2020 VL4 OVERNTGHTDELIVERY Diane Hanian Commission Secretary Idaho Public Utilities Commission I1331 W Chinden Blvd Building 8 Suite 201A Boise,Idaho,83714 Re:CASE NO.PAC-E-19-15 IN THE MATTER OF THE APPLICATION OF ROCKY MOUNTAIN POWER FOR AUTHORITY TO MODIFY ELECTRIC SERIVCE SCHEDULE NO.31 PARTIAL REQUIREMENTSSERVICE Dear Ms.Hanian: Enclosed for approval in the above referenced matter are an original and two (2)copies of Rocky Mountain Power's conforming tariff sheets reflecting the changes to Electric Service Schedule No. 31 -Partial Requirements Service as approved by Commission Order No.34553.Please provide a stamped copy of the approved tariff to the Company. Please contact Ted Weston,Idaho Regulatory Affairs Manager at (801)220-2963 if you have any questions. V ry truly yours, Joelle R.Stewar Vice President,Regulation Enclosures ROCKY MOUNTAIN POWER A DIVISION OF PACIFICORP First Revision of Sheet No.31.1 I.P.U.C.No.1 Canceling Original Sheet No.31.1 ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO.31 STATE OF IDAHO Partial Requirements Service--Large General Service-1,000 kW and Over AVAILABILITY:At any point on the Company's interconnected system where there are facilities of adequate capacity. APPLICATION:This Schedule is for alternatingcurrent,three phase electric service supplied at Company's available voltage through a single point of delivery for Supplementary,Back-up,Maintenance Power or Excess Service (partial requirements service)in addition to regular electric requirements obtained from any service other than the Company,includingon-site generation.This Schedule is applicable to customers with on-site generation of more than 1,000 kW but that does not exceed 15,000 kW.Customers not contracting for Back-up Power shall not be subject to this Schedule and shall receive electric service under the applicable general service schedule.This Schedule is not applicable to service for resale,intermittent or highly fluctuating loads,or seasonal use.This Schedule is not required where on-site generation is used only for emergency supply during times of utility outage.This Schedule is not available to loads in excess of 15,000 kW,a maximum power requirement in excess of 15,000 kW shall be deemed to exist when a Customer's maximum power requirement exceeds 15,000 kW in at least three (3)months of any continuous period of six (6) successive months. MONTHLY BILL: Rate: Billing Months May Billing Months November throughOctober,Inclusive throughApril,Inclusive Customer Service Charge: Secondary Voltage $37.00 per Customer $37.00 per Customer Primary Voltage $111.00 per Customer $111.00 per Customer Transmission $370.00 per Customer $370.00 per Customer Voltage Back-up Facilities Rate: Secondary Voltage $7.94 per kW for all kW $6.49 per kW for all kW Primary Voltage $7.58 per kW for all kW $6.13 per kW for all kW Transmission $5.70 per kW for all kW $4.30 per kW for all kW Voltage The Facilities Rate applies to the kW of Back-up Contract Power (continued) Submitted Under Case No.PAC-E-19-15 ISSUED:October 10,2019 EFFECTIVE:February 11,2020 IDAHO PUBLIC UTILITIES COMMISSION Approved Effective Mar. 2, 2020 Feb. 11, 2020 Per O.N. 34553 Diane M. Hanian Secretary ROCKY MOUNTAINPOWER A DIVISION OF PACIFICORP Third Revision of Sheet No.31.2 I.P.U.C.No.1 Canceling Second Revision of Sheet No.31.2 ELECTRIC SERVICE SCHEDULE NO.31 -Continued MONTHLY BILL: Rate: Billing Months May Billing Months November through October,Inclusive through April,Inclusive Back-up Power Rate: Secondary Voltage $0.26 all kW Day $0.22 all kW Day Primary Voltage $0.25 all kW Day $0.21 all kW Day Transmission $0.19 all kW Day $0.14 all kW Day Voltage Back-up Power is billed on a per day basis and is based on the fifteen (15) minute period of the Customer's greatest use of Back-up Power duringthe day Scheduled Maintenance Power rate is one half (1/2)of the Back-up Power Excess Power Rate: Secondary Voltage $28.72 per kW for all kW $23.62 per kW for all kW Primary Voltage $27.42 per kW for all kW $22.32 per kW for all kW Transmission $20.52 per kW for all kW $15.48 per kW for all kW Voltage Supplementary Power Rate: Secondary Voltage $14.36 per kW for all kW $11.81 per kW for all kW Primary Voltage $13.71 per kW for all kW $11.16 per kW for all kW Transmission $10.26 per kW for all kW $7.74 per kW for all kW Voltage Supplementary and Back-up Energy Rate: Secondary Voltage 3.9880¢per kWh 3.9880¢per kWh Primary Voltage 3.9880¢per kWh 3.9880¢per kWh Transmission 4.1872¢per kWh 4.1872¢per kWh Voltage POWER FACTOR:This rate is based on the Customer maintaining at all times a power factor of 85% lagging,or higher,as determined by measurement.If the average power factor is found to be less than 85%lagging, the Power as recorded by the Company's meter will be increased by ¾of 1%for every1%that the power factor is less than 85%. VOLTAGE LEVELS:Secondary Voltage applies where a distribution Customer takes service from Company's available lines of less than 2,300 volts.Primary Voltage applies where a distributionCustomer takes service fromCompany'savailable lines of2,300 to less than 46,000 volts and provides and maintains all transformers and other necessary related equipment.Transmission Voltage applies where service is supplied at approximately 46,000 volts or greater througha single point of delivery. (continued) Submitted Under Case No.PAC-E-19-15 ISSUED:October 10,2019 EFFECTIVE:February 11,2020 IDAHO PUBLIC UTILITIES COMMISSION Approved Effective Mar. 2, 2020 Feb. 11, 2020 Per O.N. 34553 Diane M. Hanian Secretary