Loading...
HomeMy WebLinkAbout20161011Attachment 2.pdfAttachment 2 2014 Idaho Annual Demand Side Management Report Appendices A endix 1 Rocky Mountain Power Attachment 2 Page 1 of 112 Case No. PAC-E-16-14 Explanation of Capacity Estimates 2014 Energy Efficiency Programs Rocky Mountain Power Attachment 2 Page 2 of 112 Case No. PAC-E-16-14 The MW reported savings of 2.57 (at generation) for energy efficiency programs during 2014 represents the summation of estimated MW values made available through the Company's business and residential energy efficiency programs; calculations for the business and residential programs differ. The Company's business programs MW contributions are based on engineering estimates of capacity values for installed measures; project unique factors are individually calculated for custom projects while deemed factors are utilized for prescriptive measures. These calculations are based on actual installed measures in the reported year. For 2014, it is calculated that 0.86 MW of capacity contribution were made available through business program energy efficiency acquisitions. Specific hours during which business program measures contribute MW capacity are dependent upon several factors including specific business operations and general economic conditions. For the residential programs, an energy to capacity factor is utilized to calculate the MW savings made available through these programs. The energy to capacity factor utilized in the calculation (2 .41 MW in 2014 for each average MWh of energy efficiency acquired) is the same as the average load profile factor of energy efficiency resources selected in the 2013 IRP, i.e. the average peak contribution of the energy efficiency resource selections across all measures and sectors. The utilization of this factor in the MW calculation assumes that the energy efficiency resources acquired through the Company's residential programs have the same average load profile as those energy efficiency resources selected in the 2013 IRP. Utilization of this factor in determining the MW contribution of energy efficiency programs for 2014 is detailed in the table below. Line Description Value I First year EE program savings acquired during 2013 6,208 2 Average MWh value (line I / 8760 hours) 0.71 3 Peak MW contribution of 20 I 4 EE acquisitions 1.7 I As demonstrated, it is estimated that the residential energy efficiency program acquisitions in 2014 contributed 1. 71 MW of capacity contribution. As with the business programs, when these savings occur on an hourly basis is dependent upon several factors including energy usage patterns of residential customers. Together, the 0.86 MW's estimated for the business programs and the 1.71 MW's estimated for residential programs make up the 2.57 MW savings value of energy efficiency programs. A endix 2 Idaho Cost Effectiveness Rocky Mountain Power Attachment 2 Page 3 of 112 Case No. PAC-E-16-14 Table of Contents Rocky Mountain Power Attachment 2 Page 4 of 112 Case No. PAC-E-16-14 Portfolio and Sector Level Cost Effectiveness ............................................................................... 3 Program Level Cost Effectiveness .................................................................................................. 7 Home Energy Savers Program ..................................................................................................... 7 Refrigerator Recycling (See ya later, refrigerator) .................................................................... 14 Low Income Weatherization ...................................................................................................... 17 wattsmart Business ..................................................................................................................... 19 Page 2 of 24 Portfolio and Sector Level Cost Effectiveness Rocky Mountain Power Attachment 2 Page 5 of 112 Case No. PAC-E-16-14 Navigant estimated the cost-effectiveness for the overall energy efficiency portfolio and component sectors, based on 2014 costs and savings estimates provided by PacifiCorp. This memo provides the cost-effectiveness results for the overall energy efficiency portfolio and the two sector components. The program passes the cost-effectiveness for all the tests except the RIM test. The memo consists of the following tables. Table 1 -Utility Inputs Table 2 -Portfolio Level Costs 2014 Table 3 -Benefit/Cost Ratios by Portfolio Type Table 4 -2014 Total Portfolio Cost-Effectiveness Results Table 5 -2014 Total Portfolio Cost-Effectiveness Results (Including NEBs) Table 6 -2014 C&I Energy Efficiency Portfolio Cost-Effectiveness Results Table 7 -2014 Residential Energy Efficiency Portfolio Cost-Effectiveness Results Table 8 -2014 Residential Energy Efficiency Portfolio Cost-Effectiveness Results (Including NEBs) Table 1 -Utility Inputs Parameter Value Discount Rate Residential Line Loss Commercial Line Loss Industrial Line Loss Irrigation Line Loss Residential Energy Rate ($/kWh)(base year 2014) Commercial Energy Rate ($/kWh)(base year 2014) Industrial Energy Rate ($/kWh)(base year 2014) Irrigation Energy Rate ($/kWh)(base year 2014) Inflation Ratei 6.88% 11.47% 10.75% 7.52% 11.45% $0.1049 $0.0866 $0.0698 $0.0886 1.90% 1 Future rates determined using a 1.9% annual escalator. Page 3 of 24 Rocky Mountain Power Attachment 2 Page 6 of 112 Case No. PAC-E-16-14 Table 2 -Portfolio Level Costs 2014 Cost Value Commercial and Industrial Evaluation Costs Residential Evaluation Costs Low Income Energy Conservation Education Outreach & Communications Wattsmart Technical Reference Library DSM Central Total Costs $110,685 $93,900 $25,000 $4,989 $14,488 $13,309 $262,372 Table 3 -Benefit/Cost Ratios by Portfolio Type Measure Group PTRC TRC UCT RIM PCT Total Portfolio 1.52 1.38 1.69 0.54 4.01 Total Portfolio (Including NEBs) 1.59 1.45 1.69 0.54 4.10 C&I Programs 1.32 1.20 1.67 0.56 3.02 Residential Programs1 1.95 1.77 1.79 0.52 6.30 Residential Programs (Including NEBs)1 2.15 1.98 1.79 0.52 6.60 1 Includes additional costs of $20,473 for the Home Energy Reporting program. Table 4 -2014 Total Portfolio Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/k\"h Costs Benefits 8 f" R . , ene its atio Total Resource Cost Test (PTRC) + $0.0574 $3,955,735 $6,002,194 $2,046,459 1.52 Conversation Adder Total Resource Cost Test (TRC) $0.0574 $3,955,735 $5,456,540 $1,500,804 1.38 No Adder Utility Cost Test (UCT) $0.0468 $3,222,116 $5,456,540 $2,234,424 1.69 Rate Impact Test (RIM) $10,191,009 $5,456,540 -$4,734,470 0.54 Participant Cost Test (PCT) $2,730,801 $10,947,406 $8,216,605 4.01 Lifecycle Revenue Impacts ($/kWh) $0.000115178 Page 4 of 24 I Rocky Mountain Power Attachment 2 Page 7 of 112 Case No. PAC-E-16-14 Table 5 -2014 Total Portfolio Cost-Effectiveness Results (Including NEBs) . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits B f. R . ene its aho Total Resource Cost Test (PTRC) + $0.0574 $3,955,735 $6,279,040 $2,323,305 1.59 Conversation Adder Total Resource Cost Test (TRC) $0.0574 $3,955,735 $5,733,386 $1,777,650 1.45 No Adder Utility Cost Test (UCT) $0.0468 $3,222,116 $5,456,540 $2,234,424 1.69 Rate Impact Test (RIM) $10,191,009 $5,456,540 -$4,734,470 0.54 Participant Cost Test (PCT) $2,730,801 $11,192,677 $8,461,876 4.10 Lifecycle Revenue Impacts ($/kWh) $0.000115178 Table 6 -2014 C&I Energy Efficiency Portfolio Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/k"'h Costs Benefits B f' R . n ene its atio Total Resource Cost Test (PTRC) + $0.0640 $2,549,724 $3,377,613 $827,889 1.32 Conversation Adder Total Resource Cost Test (TRC) $0.0640 $2,549,724 $3,070,557 $520,833 1.20 No Adder Utility Cost Test (UCT) $0.0461 $1,835,053 $3,070,557 $1,235,504 1.67 Rate Impact Test (RIM) $5,531,701 $3,070,557 -$2,461,144 0.56 Participant Cost Test (PCT) $1,908,474 $5,767,031 $3,858,557 3.02 Lifecycle Revenue Impacts ($/kWh) $0.000051248 Table 7 -2014 Residential Energy Efficiency Portfolio Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits B f" R . ene its atio Total Resource Cost Test (PTRC) + $0.0464 $1,348,224 $2,624,581 $1,276,356 1.95 Conversation Adder Total Resource Cost Test (TRC) $0.0464 $1,348,224 $2,385,983 $1,037,758 1.77 No Adder Utility Cost Test (UCT) $0.0458 $1,329,276 $2,385,983 $1,056,707 1.79 Rate Impact Test (RIM) $4,601,521 $2,385,983 -$2,215,539 0.52 Participant Cost Test (PCT) $822,327 $5,180,375 $4,358,048 6.30 Lifecycle Revenue Impacts ($/kWh) $0.000072012 Page 5 of 24 Rocky Mountain Power Attachment 2 Page 8 of 112 Case No. PAC-E-16-14 Table 8 -2014 Residential Energy Efficiency Portfolio Cost-Effectiveness Results (Including NEBs) . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits B f' R . ene its aho Total Resource Cost Test (PTRC) + $0.0464 $1,348,224 $2,901,427 $1,553,202 2.15 Conversation Adder Total Resource Cost Test (TRC) $0.0464 $1,348,224 $2,662,829 $1,314,604 1.98 No Adder Utility Cost Test (UCT) $0.0458 $1,329,276 $2,385,983 $1,056,707 1.79 Rate Impact Test (RIM) $4,601,521 $2,385,983 -$2,215,539 0.52 Participant Cost Test (PCT) $822,327 $5,425,646 $4,603,319 6.60 Lifecycle Revenue Impacts ($/kWh) $0.000072012 Page 6 of 24 Rocky Mountain Power Attachment 2 Page 9 of 112 Case No. PAC-E-16-14 Program Level Cost Effectiveness Home Energy Savers Program Navigant estimated the cost-effectiveness results for the Idaho Home Energy Savings Program, based on 2014 costs and savings estimates provided by PacifiCorp. This memo provides the cost­ effectiveness results for the overall program and for the 6 measure categories. Cost-effectiveness was tested using the 2013 IRP East Residential Whole House 35% and East Residential Lighting 48% load factor decrements. The program passes the cost-effectiveness for all the tests except the RIM test. The memo consists of the following tables. Table 1 -Home Energy Savings Inputs Table 2 -Home Energy Savings Annual Program Costs Table 3 -Home Energy Savings -Savings by Measure Category Table 4 -Benefit/Cost Ratios by Measure Category Table 5 -Home Energy Savings Program Level Cost-Effectiveness Results Table 6 -Home Energy Savings Appliances Cost-Effectiveness Results Table 7 -Home Energy Savings Energy Savings Kits Cost-Effectiveness Results Table 8 -Home Energy Savings HVAC Cost-Effectiveness Results Table 9 -Home Energy Savings Lighting Cost-Effectiveness Results Table 10 -Home Energy Savings Manufactured Home Cost-Effectiveness Results Table 11 -Home Energy Savings Weatherization Cost-Effectiveness Results Table 12-Home Energy Savings Appliances Non-Energy Benefits Table 13 -Home Energy Savings Appliances (with NEBs) Cost-Effectiveness Results Table 14 -Home Energy Savings Energy Savings Kits Non-Energy Benefits Table 15 -Home Energy Savings Energy Savings Kits (with NEBs) Cost-Effectiveness Results Table 16 -Home Energy Savings Lighting Non-Energy Benefits Table 17 -Home Energy Savings Lighting (with NEBs) Cost-Effectiveness Results Table 18 -Home Energy Savings Program Cost-Effectiveness Results with Non-Energy Benefits Table 1 -Home Energy Savings Inputs Parameter Value Discount Rate Residential Line Loss Residential Energy Rate ($/kWh)(base year 2014) Inflation Rate1 6.88% 11.47% $0.1049 1.90% 1 Future rates determined using a 1.9% annual escalator. Page 7 of 24 Table 2 -Home Energy Savings Annual Program Costs Rocky Mountain Power Attachment 2 Page 1 O of 112 Case No. PAC-E-16-14 E · · ·i· Total Gross ngmeenng Uh 1ty Program Program . . . Measure Group C Ad . 0 1. 0 Incentives Uhhty Customer osts mm e 1very ev. C C osts osts Appliances $0 $762 $24,030 $0 $17,772 $42,563 $66,084 Energy Savings Kits $0 $56,031 $82,120 $0 $87,851 $226,002 $104,522 HVAC $0 $2,149 $67,799 $0 $28,875 $98,823 $102,284 Lighting $0 $24,891 $34,582 $0 $404,522 $463,995 $508,536 Manufactured Horne $0 $806 $25,423 $0 $5,740 $31,968 $5,740 Weatherization $0 $1,044 $32,949 $0 $24,861 $58,855 $35,161 Total $0 $85,682 $266,903 $0 $569,621 $922,206 $822,327 Table 3 -Home Energy Savings -Savings by Measure Category M G Gross kWh Realization GAdjuskte.4!_ Net to Gross Net kWh Measure easure roup 5 . ross h n . 5 . "f avmgs Rate 5 . Ratio avmgs Li e avmgs Appliances 43,232 81% 35,009 100% 35,009 14 Energy Savings Kits 3,180,964 100% 3,180,964 78% 2,480,687 9 HVAC 121,977 100% 121,977 63% 76,845 20 Lighting 1,413,094 100% 1,413,094 66% 932,642 8 Manufactured Horne 45,738 100% 45,738 100% 45,738 18 Weatherization 59,279 95% 56,315 100% 56,315 30 Total 4,864,284 100% 4,853,097 75% 3,627,237 9 Table 4 -Benefit/Cost Ratios by Measure Category Measure Group PTRC TRC UCT RIM PCT Appliances 0.35 0.32 0.69 0.36 0.86 Appliances with NEBs 0.49 0.45 0.69 0.36 1.04 Energy Savings Kits 7.04 6.40 6.22 0.64 25.21 Energy Savings Kits with NEBs 7.89 7.25 6.22 0.64 27.00 HVAC 0.95 0.86 1.18 0.56 1.96 Lighting 1.30 1.18 1.01 0.41 2.82 Lighting with NEBs 1.42 1.30 1.01 0.41 2.91 Manufactured Home 1.56 1.42 1.42 0.49 11.53 Wea theriza tion 1.21 1.10 1.29 0.48 3.50 Total 2.50 2.27 2.32 0.55 5.49 Total (with NEBs) 2.76 2.53 2.32 0.55 5.79 Page 8 of 24 -------------------------------------------------·-··-----·····-- Rocky Mountain Power Attachment 2 Page 11 of 112 Case No. PAC-E-16-14 Table 5 -Home Energy Savings Program Level Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/k\•'h Costs Benefits B f' R . , ene its aho Total Resource Cost Test (PTRC) + $0.0357 $941,154 $2,353,960 $1,412,806 Conversation Adder Total Resource Cost Test (TRC) $0.0357 $941,154 $2,139,964 $1,198,810 No Adder Utility Cost Test (UCT) $0.0349 $922,206 $2,139,964 $1,217,758 Rate Impact Test (RIM) $3,894,091 $2,139,964 -$1,754,127 Participant Cost Test (PCT) $822,327 $4,515,723 $3,693,396 Lifecycle Revenue Impacts ($/kWh) Discounted Participan t Payback (years) Table 6 through Table I I provides cost-effectiveness results for all 6 measures. Table 6 -Home Energy Savings Appliances Cost-Effectiveness Results (2013 IRP East Residential Whole House 35%) 2.50 2.27 2.32 0.55 5.49 $0.000057015 0.65 . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits Benefits Ratio Total Resource Cost Test (PTRC) + $0.2619 $90,875 $32,238 -$58,637 Conversation Adder Total Resource Cost Test (TRC) $0.2619 $90,875 $29,307 -$61,568 No Adder Utility Cost Test (UCT) $0.1227 $42,563 $29,307 -$13,256 Rate Impact Test (RIM) $81,695 $29,307 -$52,387 Participant Cost Test (PCT) $66,084 $56,903 -$9,181 Lifecycle Revenue Impacts ($/kWh) Discounted Participant Payback (years) Table 7 -Home Energy Savings Energy Savings Kits Cost-Effectiveness Results (2013 IRP East Residential Whole House 35%) 0.35 0.32 0.69 0.36 0.86 $0.000001091 19.31 . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits Benefits Ratio Total Resource Cost Test (PTRC) + Conversation Adder Total Resource Cost Test (TRC) No Adder Utility Cost Test (UCT) Rate Impact Test (RIM) Participant Cost Test (PCT) Lifecycle Revenue Impacts ($/kWh) Discounted Participant Payback (years) $0.0124 $219,663 $0.0124 $219,663 $0.0128 $226,002 $2,212,718 $104,522 $1,545,651 $1,325,988 7.04 $1,405,137 $1,185,475 6.40 $1,405,137 $1,179,136 6.22 $1,405,137 -$807,581 0.64 $2,635,400 $2,530,878 25.21 $0.000026249 0.06 Page 9 of 24 Rocky Mountain Power Attachment 2 Page 12 of 112 Case No. PAC-E-16-14 Table 8 -Home Energy Savings HV AC Cost-Effectiveness Results (2013 IRP East Residential Whole House 35%) . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits 8 f" R . ene its aho Total Resource Cost Test (PTRC) + $0.1401 $134,386 $127,794 -$6,592 0.95 Conversation Adder Total Resource Cost Test (TRC) $0.1401 $134,386 No Adder $116,177 -$18,210 0.86 Utility Cost Test (UCT) $0.1030 $98,823 $116,177 $17,354 1.18 Rate Impact Test (RIM) $207,212 $116,177 -$91,035 0.56 Participant Cost Test (PCT) $102,284 $200,921 $98,638 1.96 Lifecycle Revenue Impacts ($/kWh) $0.000001321 Discounted Participant Payback (years) Table 9 -Home Energy Savings Lighting Cost-Effectiveness Results (2013 IRP East Residential Lighting 48%) 11.30 . levelized . Net Benefit/Cost Cost-Effectiveness Test $/k\"h Costs Benefits B f' R . , ene its aho Total Resource Cost Test (PTRC) + $0.0655 $395,106 Conversation Adder $514,771 $119,665 1.30 Total Resource Cost Test (TRC) $0.0655 $395,106 $467,974 $72,868 1.18 No Adder Utility Cost Test (UCT) $0.0769 $463,995 $467,974 $3,979 1.01 Rate Impact Test (RIM) $1,142,875 $467,974 -$674,901 0.41 Participant Cost Test (PCT) $508,536 $1,433,128 $924,592 2.82 Lifecycle Revenue Impacts ($/kWh) $0.000024691 Discounted Participant Payback (years) 1.05 Table 10 -Home Energy Savings Manufactured Homes Cost-Effectiveness Results (2013 IRP East Residential Whole House 35%) . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/k "h Costs Benefits f" • h Bene its Ratio Total Resource Cost Test (PTRC) + $0.0597 $31,968 Conversation Adder $49,926 $17,958 1.56 Total Resource Cost Test (TRC) $0.0597 $31,968 No Adder $45,388 $13,419 1.42 Utility Cost Test (UCT) $0.0597 $31,968 $45,388 $13,419 1.42 Rate Impact Test (RIM) $92,437 $45,388 -$47,049 0.49 Participant Cost Test (PCT) $5,740 $66,208 $60,468 11.53 Lifecycle Revenue Impacts ($/kWh) $0.000000760 Discounted Participant Payback (years) 0.00 Page 10 of 24 Rocky Mountain Power Attachment 2 Page 13 of 112 Case No. PAC-E-16-14 Table 11-Home Energy Savings Weatherization Cost-Effectiveness Results (2013 IRP East Residential Whole House 35%) . Levelized . Net Benefit/Cost Cost-Effectiveness Test S/l .. 'h Costs Benefits B f" • ,., e~,h R~o Total Resource Cost Test (PTRC) + $0.0797 $69,155 $83,579 $14,424 1.21 Conversation Adder Total Resource Cost Test (TRC) $0.0797 $69,155 $75,981 $6,826 1.10 No Adder Utility Cost Test (UCT) $0.0678 $58,855 $75,981 $17,126 1.29 Rate Impact Test (RIM) $157,156 $75,981 -$81,175 0.48 Participant Cost Test (PCT) $35,161 $123,162 $88,001 3.50 Lifecycle Revenue Impacts ($/kWh) $0.000000782 Discounted Participant Payback (years) 1.75 In addition to the energy benefits reported above, appliances, energy savings kits and lighting in the Home Energy Savings program offer significant non-energy benefits (NEBs). Table 12, Table 14 and Tablel6 details the non-energy benefits for appliances, energy savings kits and lighting respectively. Table 12 -Home Energy Savings Appliances Non-Energy Benefits Non-Energy . Non-Energy B f" Total Annual Perspective . ene its per . Benefits M Installs Value Ad Justed easure Clothes Washers $41.64 287 $11,951 PTRC,TRC,PCT Table 13 -Home Energy Savings Appliances (with NEBs) Cost-Effectiveness Results (2013 IRP East Residential Whole House 35%) . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/l Wh Costs Benefits B t· R . , ene its aho Total Resource Cost Test (PTRC) + $0.2619 $90,875 $44,189 -$46,686 0.49 Conversation Adder Total Resource Cost Test (TRC) $0.2619 $90,875 $41,258 -$49,617 0.45 No Adder Utility Cost Test (UCT) $0.1227 $42,563 $29,307 -$13,256 0.69 Rate Impact Test (RIM) $81,695 $29,307 -$52,387 0.36 Participant Cost Test (PCT) $66,084 $68,854 $2,770 1.04 Lifecycle Revenue Impacts ($/kWh) $0.000001091 Discounted Participant Payback (years) 19.31 Page 11 of 24 Rocky Mountain Power Attachment 2 Page 14 of 112 Case No. PAC-E-16-14 Table 14 -Home Energy Savings Energy Savings Kits Non-Energy Benefits Non-Energy . Non-Energy f' Total Annual Perspective . B=~~ . Benefits M Installs Value Ad1usted easure Basic Kit 1 $23.61 1047 $24,720 PTRC, TRC, PCT Basic Kit 2 $44.14 3008 $132,773 PTRC, TRC, PCT Best Kit 1 $23.13 51 $1,180 PTRC, TRC, PCT Best Kit 2 $43.66 282 $12,312 PTRC, TRC, PCT Better Kit 1 $23.61 42 $992 PTRC, TRC, PCT Better Kit 2 $44.14 124 $5,473 PTRC, TRC, PCT CFL Kit $3.08 2769 $8,529 PTRC, TRC, PCT LED Kit $2.60 189 $491 PTRC,TRC,PCT Table 15 -Home Energy Savings Energy Savings Kits (with NEBs) Cost-Effectiveness Results (2013 IRP East Residential Whole House 35%) . Levelized . Net Benefit/Cost Cost-Effectiveness Test S/k"Th Costs Benefits B f' R . .. ene its atio Total Resource Cost Test (PTRC) + $0.0124 $219,663 $1,732,121 $1,512,458 7.89 Conversation Adder Total Resource Cost Test (TRC) $0.0124 $219,663 $1,591,607 $1,371,944 7.25 No Adder Utility Cost Test (UCT) $0.0128 $226,002 $1,405,137 $1,179,136 6.22 Rate Impact Test (RIM) $2,212,718 $1,405,137 -$807,581 0.64 Participant Cost Test (PCT) $104,522 $2,821,870 $2,717,348 27.00 Lifecycle Revenue Impacts ($/kWh) $0.000026249 Discounted Participant Payback (years) 0.06 Table 16 -Home Energy Savings Lighting Non-Energy Benefits Non-Energy . Non-Energy B f" Total Annual Perspective . =~~ . Benefits M Installs Value Ad1usted easure CFL General $0.77 43,601 $33,573 PTRC, TRC, PCT CFL Specialty $1.18 10286 $12,137 PTRC,TRC,PCT LED General $0.65 273 $177 PTRC, TRC, PCT LED Specialty $2.76 349 $963 PTRC, TRC, PCT Page 12 of 24 I Rocky Mountain Power Attachment 2 Page 15 of 112 Case No. PAC-E-16-14 Table 17 -Home Energy Savings Lighting (with NEBs) Cost-Effectiveness Results (2013 IRP East Residential Lighting 48%) . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits Benefits Ratio Total Resource Cost Test (PTRC) + $0.0655 $395,106 $561,622 $166,516 1.42 Conversation Adder Total Resource Cost Test (TRC) $0.0655 $395,106 $514,825 $119,719 1.30 No Adder Utility Cost Test (UCT) $0.0769 $463,995 $467,974 $3,979 1.01 Rate Impact Test (RIM) $1,142,875 $467,974 -$674,901 0.41 Participant Cost Test (PCT) $508,536 $1,479,979 $971,443 2.91 Lifecycle Revenue Impacts ($/kWh) $0.000024691 Discounted Participant Payback (years) 1.05 Table 18 -Home Energy Savings Program Cost-Effectiveness Results with Non-Energy Benefits . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/k""-Costs Benefits B f" R . n n ene its atio Total Resource Cost Test (PTRC) + $0.0357 $941,154 $2,599,231 $1,658,077 2.76 Conversation Adder Total Resource Cost Test (TRC) $0.0357 $941,154 $2,385,235 $1,444,081 2.53 No Adder Utility Cost Test (UCT) $0.0349 $922,206 $2,139,964 $1,217,758 2.32 Rate Impact Test (RIM) $3,894,091 $2,139,964 -$1,754,127 0.55 Participant Cost Test (PCT) $822,327 $4,760,994 $3,938,667 5.79 Lifecycle Revenue Impacts ($/kWh) $0.000057015 Discounted Participant Payback (years) 0.65 Page 13 of 24 Rocky Mountain Power Attachment 2 Page 16 of 112 Case No. PAC-E-16-14 Refrigerator Recycling (See ya later, refrigerator) Navigant estimated the cost-effectiveness results for the Idaho See Ya Later Refrigerator (SYLR) Program, based on 2014 costs and savings estimates provided by PacifiCorp. This memo provides the cost-effectiveness results for the overall program and for the 3 measure categories. Cost-effectiveness was tested using the 2013 IRP East Residential Whole House 35% and East Residential Lighting 48% load factor decrements. The program passes the cost-effectiveness for all the tests except the RIM and PCT tests. The memo consists of the following tables. Table 1 -SYLR Inputs Table 2 -SYLR Annual Program Costs Table 3 -SYLR Savings by Measure Category Table 4 -Benefit/Cost Ratios by Measure Category Table 5 -SYLR Program Level Cost-Effectiveness Results Table 6 -SYLR Refrigerators Cost-Effectiveness Results Table 7 -SYLR Freezers Cost-Effectiveness Results Table 8 -SYLR Kits Cost-Effectiveness Results Table 1-SYLR Inputs Parameter Value Discount Rate Residential Line Loss Residential Energy Rate ($/kWh)(base year 2014) Inflation Rate1 6.88% 11.47% $0.1049 1.90% 1 Future rates determined using a 1.9% annual escalator. Table 2 -SYLR Annual Program Costs 1\1 E . . U ·1· I ·1· Gross easure ngmeenng h 1ty d . Program . Tota Uti 1ty G C Adm. A mm O Incentives C Customer roup osts m ev. osts Refrigerators Freezers Kits Total $0 $0 $0 $0 $9,250 $43,393 $8,201 $2,657 $12,464 $2,355 $338 $1,586 $300 $12,244 $57,443 $10,856 $20,600 $6,090 $3,368 $30,058 $81,443 $23,566 $5,592 $110,601 Costs $0 $0 $0 $0 Page 14 of 24 Rocky Mountain Power Attachment 2 Page 17 of 112 Case No. PAC-E-16-14 Table 3 -SYLR Savings by Measure Category Measure Gross kWh Realization Adjusted Net to Gross Net kWh Measure Group Savings Rate Gross kWh Savings Ratio Savings Life Refrigerators Freezers Kits Total 492,912 141,577 18,016 652,505 100% 100% 100% 100% 492,912 141,577 18,016 652,505 54% 48% 100% 54% Table 4 -Benefit/Cost Ratios by Measure Category 266,172 67,957 18,016 352,145 Measure Group PTRC TRC UCT RIM PCT Refrigerators Freezers Kits Total 1.68 1.10 1.39 1.54 1.53 1.00 1.26 1.40 1.53 1.00 1.26 1.40 0.49 0.41 0.44 0.47 Table 5 -SYLR Program Level Cost-Effectiveness Results n/a n/a n/a n/a 7 5 6 7 . Levelized . Net Benefit/Cost Cost-Effectiveness Test S/k\"h Costs Benefits 8 f" R . , ene its aho Total Resource Cost Test (PTRC) + $0.0574 $110,601 $170,731 $60,130 1.54 Conversation Adder Total Resource Cost Test (TRC) $0.0574 $110,601 $155,210 $44,609 1.40 No Adder Utility Cost Test (UCT) $0.0574 $110,601 $155,210 $44,609 1.40 Rate Impact Test (RIM) $327,358 $155,210 -$172,148 0.47 Participant Cost Test (PCT) $0 $430,355 $430,355 n/a Lifecycle Revenue Impacts ($/kWh) $0.000007201 Discounted Participant Payback (years) n/a Table 6 through Table 8 provides cost-effectiveness results for all 3 measures. Page 15 of 24 Rocky Mountain Power Attachment 2 Page 18 of 112 Case No. PAC-E-16-14 Table 6 -SYLR Refrigerators Cost-Effectiveness Results (2013 IRP East Residential Whole House 35%) . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits 8 f" R . Total Resource Cost Test (PTRC) + $0.0528 $81,443 $137,179 Conversation Adder Total Resource Cost Test (TRC) $0.0528 $81,443 $124,708 No Adder Utility Cost Test (UCT) $0.0528 $81,443 $124,708 Rate Impact Test (RIM) $254,822 $124,708 Participant Cost Test (PCT) $0 $341,673 Lifecycle Revenue Impacts ($/kWh) Discounted Participant Payback (years) Table 7 -SYLR Freezers Cost-Effectiveness Results (2013 IRP East Residential Whole House 35%) ene its aho $55,735 1.68 $43,265 1.53 $43,265 1.53 -$130,115 0.49 $341,673 n/a $0.000005442 n/a . Levelized . Net Benefit/Cost Cost-Effectiveness Test S/k\Vh Costs Benefits B f" R . Total Resource Cost Test (PTRC) + $0.0801 $23,566 $25,807 Conversation Adder Total Resource Cost Test (TRC) $0.0801 $23,566 $23,461 No Adder Utility Cost Test (UCT) $0.0801 $23,566 $23,461 Rate Impact Test (RIM) $56,655 $23,461 Participant Cost Test (PCT) $0 $75,025 Lifecycle Revenue Impacts ($/kWh) Discounted Participant Payback (years) Table 8 -SYLR Kits Cost-Effectiveness Results (2013 IRP East Residential Lighting 48%) ene its atio $2,241 1.10 -$105 1.00 -$105 1.00 -$33,194 0.41 $75,025 n/a $0.000001946 n/a . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits f" R . Bene its atio Total Resource Cost Test (PTRC) + $0.0611 $5,592 $7,745 $2,154 1.39 Conversation Adder Total Resource Cost Test (TRC) $0.0611 $5,592 $7,041 $1,450 1.26 No Adder Utility Cost Test (UCT) $0.0611 $5,592 $7,041 $1,450 1.26 Rate Impact Test (RIM) $15,881 $7,041 -$8,839 0.44 Participant Cost Test (PCT) $0 $13,657 $13,657 n/a Lifecycle Revenue Impacts ($/kWh) $0.000000432 Discounted Participant Payback (years) n/a Page 16 of 24 Rocky Mountain Power Attachment 2 Page 19 of 112 Case No. PAC-E-16-14 Low Income Weatherization Navigant estimated the cost-effectiveness results for the Idaho Low Income Weatherization Program, based on 2014 costs and savings estimates provided by PacifiCorp. This memo provides the cost-effectiveness results for the overall program. Cost-effectiveness was tested using the 2013 IRP East Residential Whole House 35% load factor decrement. The program does not pass any of the cost-effectiveness tests. The memo consists of the following tables. Table 1 -Low Income Weatherization Inputs Table 2 -Low Income Weatherization Annual Program Costs Table 3 -Low Income Weatherization Savings by Measure Category Table 4 -Low Income Weatherization Program Level Cost-Effectiveness Results Table 5 -Low Income Weatherization Non Energy Benefits Table 6 -Low Income Weatherization Program Level (with Non Energy Benefits) Cost­ Effectiveness Results Table 1-Low Income Weatherization Inputs Parameter Value Discount Rate Residential Line Loss Residential Energy Rate ($/kWh)(base year 2014) Inflation Rate' 6.88% 11.47% $0.1049 1.90% 1 Future rates determined using a 1.9% annual escalator. Table 2 -Low Income Weatherization Annual Program Costs . . .1. Total Gross Engmeenn<> Uh 1ty Program Protrram . . . Measure Group C O Ad . 0 1. do . Incentives Uhhty Customer Low Income Weatherization Total osts mm e 1very A mm C C osts osts $0 $0 $16,455 $16,455 $13,260 $13,260 $1,688 $1,688 $150,694 $182,097 $150,694 $182,097 Table 3 -Low Income Weatherization Savings by Measure Category . . Adjusted Net to $0 $0 Gross kWh Realization G kWh G Net kWh Measure Measure Group S . R ross ross S . t·f avmgs ate S . R . avmgs 1 e Low Income Weatherization Total 52,320 52,320 100% 100% avmgs aho 52,320 52,320 100% 100% 52,320 52,320 25 25 Page 17 of 24 Rocky Mountain Power Attachment 2 Page 20 of 112 Case No. PAC-E-16-14 Table 4 -Low Income Weatherization Program Level Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits Benefits Ratio Total Resource Cost Test (PTRC) + $0.2465 $182,097 $99,889 -$82,207 0.55 Conversation Adder Total Resource Cost Test (TRC) $0.2465 $182,097 $90,809 -$91,288 0.50 No Adder Utility Cost Test (UCT) $0.2465 $182,097 $90,809 -$91,288 0.50 Rate Impact Test (RIM) $265,700 $90,809 -$174,891 0.34 Participant Cost Test (PCT) $0 $234,297 $234,297 n/a Lifecycle Revenue Impacts ($/kWh) $0.000002025 Discounted Participant Payback (years) n/a In addition to the energy benefits reported above the program offers significant non-energy benefits (NEBs) in the form of health, safety and repair costs as shown in Table 5. Table 5 -Low Income Weatherization Program Level Cost-Effectiveness Results Non-Energy Benefit Program Impact Perspective Adjusted Health, Safety and Repair Costs $31,575 PTRC, TRC Table 6 -Low Income Weatherization Program Level (with Non Energy Benefits) Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits Benefits Ratio Total Resource Cost Test (PTRC) + $0.2465 $182,097 $131,464 -$50,632 0.72 Conversation Adder Total Resource Cost Test (TRC) $0.2465 $182,097 $122,384 -$59,713 0.67 No Adder Utility Cost Test (UCT) $0.2465 $182,097 $90,809 -$91,288 0.50 Rate Impact Test (RIM) $265,700 $90,809 -$174,891 0.34 Participant Cost Test (PCT) $0 $234,297 $234,297 n/a Lifecycle Revenue Impacts ($/kWh) $0.000002025 Discounted Participant Payback (years) n/a Page 18 of 24 wattsmart Business Rocky Mountain Power Attachment 2 Page 21 of 112 Case No. PAC-E-16-14 Navigant estimated the cost-effectiveness results for the Idaho Wattsmart Business Program, based on 2014 costs and savings estimates provided by PacifiCorp. This memo provides the cost­ effectiveness results for the overall program and for the eight measure categories. Cost-effectiveness was tested using the 2013 IRP east system 70% load factor decrement. The program passes the cost-effectiveness for all the tests except the RIM test. The memo consists of the following tables. Table 1 -Utility Inputs Table 2 -Annual Commercial and Industrial Program Costs by Measure Type Table 3 -Annual Commercial and Industrial Savings by Measure Type Table 4 -Benefit/Cost Ratios by Measure Category Table 5 -Wattsmart Business Program Level Cost-Effectiveness Results Table 6 -Wattsmart Business Lighting Cost-Effectiveness Results Table 7 -Wattsmart Business HVAC Cost-Effectiveness Results Table 8 -Wattsmart Business Motors Cost-Effectiveness Results Table 9 -Wattsmart Business Irrigation Cost-Effectiveness Results Table 10 -Wattsmart Business Refrigeration Cost-Effectiveness Results Table 11 -Wattsmart Business Dairy Cost-Effectiveness Results Table 12 -Wattsmart Business Pumps Cost-Effectiveness Results Table 13 -Wattsmart Business Cooking Equipment Cost-Effectiveness Results Table 1 -Utility Inputs Parameter Value Discount Rate Commercial Line Loss Industrial Line Loss Irrigation Line Loss Commercial Energy Rate ($/kWh)(base year 2014) Industrial Energy Rate ($/kWh)(base year 2014) Irrigation Energy Rate ($/kWh)(base year 2014) Inflation Ratel 6.88% 10.75% 7.52% 11.45% $0.0866 $0.0698 $0.0886 1.90% 1 Future rates determined using a 1.9% annual escalator. Page 19 of 24 Rocky Mountain Power Attachment 2 Page 22 of 112 Case No. PAC-E-16-14 Table 2 -Annual Commercial and Industrial Program Costs by Measure Category • · •1. Total Gross Engmeermg Uti 1ty Program Proo-ram . . . Measure Group C Adm" d . Do Incentives Uhhty Customer osts m A mm ev. C C osts osts Lighting $89,046 $68,573 $196,637 $37,025 $305,974 $697,256 $870,644 HVAC $1,435 $1,105 $3,168 $597 $8,006 $14,310 $28,977 Motors $55,355 $42,629 $122,239 $23,016 $93,025 $336,265 $299,594 Irrigation $62,958 $48,483 $139,027 $26,177 $174,980 $451,625 $491,755 Refrigeration $27,904 $21,489 $61,620 $11,602 $75,105 $197,720 $179,097 Dairy $1,550 $1,193 $3,422 $644 $8,930 $15,739 $28,994 Pumps $1,802 $1,388 $3,979 $749 $2,888 $10,806 $8,483 Cooking Equipment $68 $52 $149 $28 $350 $647 $931 Total $240,118 $184,911 $530,242 $99,839 $669,258 $1,724,368 $1,908,474 Table 3 -Annual Commercial and Industrial Savings by Measure Category !\I G Gross kWh Realization GAdjusktWedh Net to Gross Net kWh Measure , easure roup 5 . ross . 5 . 'f avmgs Rate 5 . Ratio avmgs LI e avmgs Lighting 2,166,198 98% 2,112,078 73% 1,531,572 14 HVAC 34,900 98% 34,028 73% 24,675 15 Motors 1,346,613 98% 1,312,969 73% 952,099 15 Irrigation 1,531,552 98% 1,493,288 73% 1,082,857 11 Refrigeration 678,816 98% 661,857 73% 479,945 15 Dairy 37,696 98% 36,754 73% 26,652 12 Pumps 43,838 98% 42,743 73% 30,995 12 Cooking Equipment 1,644 98% 1,603 73% 1,162 10 Total 5,841,257 98% 5,695,320 73% 4,129,958 14 Page 20 of 24 Rocky Mountain Power Attachment 2 Page 23 of 112 Case No. PAC-E-16-14 Table 4 -Benefit/Cost Ratios by Measure Category Measure Group PTRC TRC UCT RIM PCT Lighting 1.23 1.12 1.64 0.55 2.57 HVAC 0.82 0.75 1.42 0.53 1.41 Motors 1.75 1.60 2.18 0.59 4.48 Irrigation 1.31 1.19 1.67 0.58 2.76 Refrigeration 1.65 1.50 1.92 0.57 4.00 Dairy 0.66 0.60 1.06 0.48 1.21 Pumps 1.56 1.42 1.85 0.54 4.60 Cooking Equipment 0.72 0.66 0.99 0.43 1.61 Total 1.38 1.26 1.78 0.57 3.02 Table 5 -Wattsmart Business Program Level Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/k'Vh Costs Benefits B f" R . .-ene its aho Total Resource Cost Test (PTRC) + $0.0612 $2,439,039 $3,377,613 $938,574 1.38 Conversation Adder Total Resource Cost Test (TRC) $0.0612 $2,439,039 $3,070,557 $631,518 1.26 No Adder Utility Cost Test (UCT) $0.0433 $1,724,368 $3,070,557 $1,346,189 1.78 Rate Impact Test (RIM) $5,421,016 $3,070,557 -$2,350,459 0.57 Participant Cost Test (PCT) $1,908,474 $5,767,031 $3,858,558 3.02 Lifecycle Revenue Impacts ($/kWh) $0.000048943 Table 6 through Table 13 provides cost-effectiveness results for all eight measures. Table 6 -Wattsmart Business Lighting Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits B f" R . ene its atio Total Resource Cost Test (PTRC) + $0.0674 $1,022,629 $1,259,106 $236,477 1.23 Conversation Adder Total Resource Cost Test (TRC) $0.0674 $1,022,629 $1,144,642 $122,013 1.12 No Adder Utility Cost Test (UCT) $0.0459 $697,256 $1,144,642 $447,386 1.64 Rate Impact Test (RIM) $2,097,552 $1,144,642 -$952,910 0.55 Participant Cost Test (PCT) $870,644 $2,237,018 $1,366,375 2.57 Lifecycle Revenue Impacts ($/kWh) $0.000019842 Discounted Participant Payback (years) 4.60 Page 21 of 24 Rocky Mountain Power Attachment 2 Page 24 of 112 Case No. PAC-E-16-14 Table 7 -Wattsmart Business HV AC Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits B f" R . ene its aho Total Resource Cost Test (PTRC) + $0.1065 $27,317 $22,423 -$4,894 0.82 Conversation Adder Total Resource Cost Test (TRC) $0.1065 $27,317 $20,384 -$6,932 0.75 No Adder Utility Cost Test (UCT) $0.0558 $14,310 $20,384 $6,074 1.42 Rate Impact Test (RIM) $38,196 $20,384 -$17,811 0.53 Participant Cost Test (PCT) $28,977 $40,945 $11,968 1.41 Lifecycle Revenue Impacts ($/kWh) $0.000000346 Discounted Participant Payback (years) n/a Table 8 -Wattsmart Business Motors Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test S/k\\'h Costs Benefits B f" R . · ene its atio Total Resource Cost Test (PTRC) + $0.0465 $460,490 $808,047 $347,557 1.75 Conversation Adder Total Resource Cost Test (TRC) $0.0465 $460,490 $734,588 $274,099 1.60 No Adder Utility Cost Test (UCT) $0.0340 $336,265 $734,588 $398,323 2.18 Rate Impact Test (RIM) $1,241,008 $734,588 -$506,419 0.59 Participant Cost Test (PCT) $299,594 $1,340,689 $1,041,095 4.48 Lifecycle Revenue Impacts ($/kWh) $0.000009834 Discounted Participant Payback (years) 2.61 Table 9 -Wattsmart Business Irrigation Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits Benefits Ratio Total Resource Cost Test (PTRC) + $0.0703 $633,241 $830,110 $196,869 1.31 Conversation Adder Total Resource Cost Test (TRC) $0.0703 $633,241 $754,645 $121,404 1.19 No Adder Utility Cost Test (UCT) $0.0502 $451,625 $754,645 $303,020 1.67 Rate Impact Test (RIM) $1,308,379 $754,645 -$553,734 0.58 Participant Cost Test (PCT) $491,755 $1,356,466 $864,711 2.76 Lifecycle Revenue Impacts ($/kWh) $0.000014706 Discounted Participant Payback (years) 3.44 Page 22 of 24 Rocky Mountain Power Attachment 2 Page 25 of 112 Case No. PAC-E-16-14 Table 10 -Wattsmart Business Refrigeration Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits B f" R . ene its aho Total Resource Cost Test (PTRC) + $0.0506 $252,487 $416,784 $164,297 1.65 Conversation Adder Total Resource Cost Test (TRC) $0.0506 $252,487 $378,895 $126,408 1.50 No Adder Utility Cost Test (UCT) $0.0396 $197,720 $378,895 $181,175 1.92 Rate Impact Test (RIM) $662,685 $378,895 -$283,790 0.57 Participant Cost Test (PCT) $179,097 $716,304 $537,208 4.00 Lifecycle Revenue Impacts ($/kWh) $0.000005511 Discounted Participant Payback (years) 2.55 Table 11-Wattsmart Business Dairy Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/k\"h Costs Benefits B f" R . , ene its aho Total Resource Cost Test (PTRC) + $0.1177 $27,834 $18,433 -$9,401 0.66 Conversation Adder Total Resource Cost Test (TRC) $0.1177 $27,834 $16,757 -$11,076 0.60 No Adder Utility Cost Test (UCT) $0.0666 $15,739 $16,757 $1,018 1.06 Rate Impact Test (RIM) $34,730 $16,757 -$17,973 0.48 Participant Cost Test (PCT) $28,994 $35,119 $6,125 1.21 Lifecycle Revenue Impacts ($/kWh) $0.000000437 Discounted Participant Payback (years) 12.94 Table 12 -Wattsmart Business Pumps Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits B f" R . ene its atio Total Resource Cost Test (PTRC) + $0.0512 $14,070 $22,008 $7,938 1.56 Conversation Adder Total Resource Cost Test (TRC) $0.0512 $14,070 $20,007 $5,937 1.42 No Adder Utility Cost Test (UCT) $0.0393 $10,806 $20,007 $9,201 1.85 Rate Impact Test (RIM) $36,984 $20,007 -$16,977 0.54 Participant Cost Test (PCT) $8,483 $38,988 $30,505 4.60 Lifecycle Revenue Impacts ($/kWh) $0.000000413 Discounted Participant Payback (years) n/a Page 23 of 24 Rocky Mountain Power Attachment 2 Page 26 of 112 Case No. PAC-E-16-14 Table 13 -Wattsmart Business Cooking Equipment Cost-Effectiveness Results . Levelized . Net Benefit/Cost Cost-Effectiveness Test $/kWh Costs Benefits B f' R . ene its aho Total Resource Cost Test (PTRC) + $0.1082 $972 $702 -$270 0.72 Conversation Adder Total Resource Cost Test (TRC) $0.1082 $972 $638 -$334 0.66 No Adder Utility Cost Test (UCT) $0.0720 $647 $638 -$9 0.99 Rate Impact Test (RIM) $1,482 $638 -$844 0.43 Participant Cost Test (PCT) $931 $1,502 $571 1.61 Lifecycle Revenue Impacts ($/kWh) $0.000000025 Discounted Participant Payback (years) 6.43 Page 24 of 24 ~2!\;~0UNTAIN Aooendix 3 Program Expenditures by Category 2014 Rocky Mountain Power Attachment 2 Page 27 of 112 Case No. PAC-E-16-14 Admin -Program Admin -Utility Program Adjusted Total Delivery Total Total Energy FinAnswer -Commercial $ 146,666.97 $16,303.77 Energy FinAnswer -Industrial $ 67,583.88 $12,896.56 FinAnswer Express -Agricultural $ 7,160.55 $6,906.08 FinAnswer Express -Commercial $629,329.02 $175,910.99 $35,731.72 FinAnswer Express -Industrial $ 308,924.70 $227,305.29 $34,518.50 Home Energy Reporting $ 20,472.99 $12,750.00 Home Energy Savings $ 922,205.61 $266,903.10 $73,912.94 Irrigation Energy Savers $ 468,972.12 $126,375.50 $34,150.86 Low Income Weatherization $ 182,096.85 $13,260.14 $16,454.75 Low Income Education $ 25,000.00 $25,000.00 Outreach & Comm -wattsmart $ 4,989.41 $39.00 Portfolio -DSM Central $ 13,309.39 $9,403.83 $3,905.56 Portfolio -TRL $14,488.17 $14,488.17 Portfolio Evaluation -C&I $ 110,684.72 $110,684.72 Portfolio Evaluation -Residential $ 93,899.56 $93,899.56 See Ya Later Refrigerator $ 110,600.81 $57,442.50 $12,244.40 wattsmart Business -Agricultural $ 3,153.00 $91.00 wattsmart Business -Commercial $ 39,556.32 $31,775.92 wattsmart Business -Industrial $ 19,085.62 $7,886.96 wattsmart Business -Portfolio $ 33,935.71 $650.00 $4,650.00 Total of all programs $ 3,222,115.40 $5,318,406.76 $553,371.87 Program Expenditures 6y category Dealer/Trade Customer Ally Incentive Equipment Incentive Total Total Engineering Total Total $76,343.98 $46,829.20 $16,397.00 $21,186.60 $351,710.13 $37,975.84 $23,184.89 $11,830.32 $561,535.82 $8,085.00 $196,242.66 $105,633.69 $0.00 $150,694.46 $30,057.98 $3,062.00 $2,317.00 $5,463.40 $11,198.66 $1,266,979.44 $158,779.46 $240,117.71 Evaluation Total $582.77 $1,087.95 $114.57 $3,677.04 $1,524.61 $3,535.80 $3,376.30 $1,099.44 $0.00 $226.88 $25,060.98 Rocky Mountain Power Attachment 2 Page 28 of 112 Case No. PAC-E-16-14 I Marketing Total $6,607.25 $13,118.94 $16,122.25 $8,202.32 $264.00 $2,855.38 $787.61 $10.01 $4,950.41 $8,952.98 $984.99 $62,856.14 A endix 4 Rocky Mountain Power Attachment 2 Page 29 of 112 Case No. PAC-E-16-14 Idaho Measure Installation Verifications Rocky Mountain Power Attachment 2 Page 30 of 112 Case No. PAC-E-16-14 Idaho Measure Installation Verifications Low Income Weatherization All projects • All measures are qualified through US Department of Energy approved audit tool. • 100 percent inspection by agency inspector of all homes treated, reconciling work completed and quality (corrective action includes measure verification) prior to invoicing Company. • Community Action Partnership Association of Idaho (CAP AI) and state inspector follows with random inspections. • Company program manager joins CAP AI and state inspectors during their monitoring session. Home Energy Savings Site inspections by Program Administrator staff for the following retrofit measures. Inspections are performed on >=5 percent of single family homes, >=5 percent of manufactured homes, and 100 percent of multifamily projects. • Duct sealing • Duct sealing and insulation • Gas furnace with electrically commutated motor (ECM) • Heat pump best practices installation and proper sizing • Heat pump tune-ups • Heat pump water heaters • Insulation • Windows No site inspections are conducted for the following measures. However, all post-purchase incented measures undergo a quality assurance review prior to the issuance of the customer/dealer incentive and recording of savings ( e.g. proof of purchase receipt review) and eligible equipment review. Additionally, customer account and customer address are checked to ensure the Company does not double pay for the same measure or double count measure savings. • Central air conditioners • Clothes washers • Electric water heater • Evaporative coolers • Freezers • Heat pumps • Ductless heat pumps • Ground source heat pumps • Refrigerators No site inspections are conducted for the following measures, which are delivered via an upstream, manufacturer buy-down model. Promotion agreement contracts are signed with Rocky Mountain Power Attachment 2 Page 31 of 112 Case No. PAC-E-16-14 manufacturers and retailers to set incentive levels, final product prices, and limits to the total number of units that can be purchased per customer. Program Administrator verifies measures for product eligibility and correct pricing. Pricing is also verified by Program Administrator field visits to retail locations. • CFL bulbs • LED bulbs • Light fixtures • Room air conditioners • Advanced power strips Customer eligibility for wattsmart Starter Kits is verified using the customer's account number and last name and cross-verifying with the current PacifiCorp customer database. Refrigerator Recycling Company hires an independent inspector to phone survey :::::. 5 percent program participants and to site inspect :::::. 5 percent of program participants in order to verifying program participation, eligibility of equipment, that vendor pick-up procedures are followed ( equipment is disabled at site, kits distributed, etc.) and to survey customer experience. wattsmart Business For projects delivered by third party program administrator Lighting projects • Retrofits -100 percent pre-and post-installation site inspections by third party consultant of all projects with incentives over a specified dollar amount. Project cost documentation reviewed for all projects. • New construction -100 percent post-installation site inspections by third party consultant of all projects with incentives over a specified dollar amount. • A percent of post-installation site inspections by program administrator of projects with incentives under a specified dollar amount. Non-lighting projects (typical upgrades/listed measures, custom measures) • 100 percent of applications with an incentive that exceeds a specified dollar amount will be inspected (via site inspection) by program administrator. • A minimum of a specified percent of remaining non-lighting applications will be inspected, either in person or via telephone interview, by program administrator. For Company in-house project manager delivered projects Lighting and non-lighting • l 00 percent pre/post-installation site inspections by third party consulting engineering firms , invoice reconciled to inspection results. • No pre-inspection for new construction All Programs Rocky Mountain Power Attachment 2 Page 32 of 112 Case No. PAC-E-16-14 As part of the third-party program evaluations (two-year cycle) process, the Company is implementing semi-annual customer surveys to collect evaluation-relevant data more frequently to cure for memory loss and other detractors such as customers moving and data not be readily available at evaluation time). This will serve as a further check verifying customer participation and measures installed. Additional record reviews and site inspections (including metering/data logging) is conducted as part of the process and impact evaluations, a final verification of measure installations. A endix 5 Rocky Mountain Power Attachment 2 Page 33 of 112 Case No. PAC-E-16-14 Home Energy Savers Retailers 2014 Table of Contents Rocky Mountain Power Attachment 2 Page 34 of 112 Case No. PAC-E-16-14 Table I: 2014 Participating Idaho Upstream Retailers ................................................................................ 3 Table 2: 2014 Participating Idaho Downstream Retailers ........................................................................... 3 Table 3: 2014 Participating Idaho HYAC Trade Allies ............................................................................... 4 Table 4: 2014 Participating Idaho Weatherization Trade Allies .................................................................. 6 Table 5: Percentage of2014 Idaho Applications by Category .................................................................... 6 Page 2 of9 Table 1: 2014 Participating Idaho Upstream Retailers Store Name City CFLs Ace Hardware #14355 Rexburg " Broulim's Fresh Foods #1 Montpelier " Broulim's Fresh Foods #2 Rexburg " Dollar Tree #3691 Rexburg " Downey Food Center # 1 Downey " Thomas Market Inc. # 1 Malad City " Walgreens #9918 Rexburg " Wal-Mart #1878 Rexburg " Table 2: 2014 Participating Idaho Downstream Retailers .... (I) .... ~ (I) .... 0 (I) * :t ..c: * 0 "' .... u "' (I) .... ~ ..c: ~ (I) "' > "' "' ~ ~ -~ (I) ..c: ..c: <.) .... 0 "' 0 Q ·;: 0. 0 -"' <.) (I) > UJ ~ Retailer Citv Ace Hardware # 14355 Rexburg Best Buy #944 Idaho Falls " Bingham & Sons Furniture and Appliance Rexburg " " Blacker's Home Furnishings Idaho Falls " " Denning's Showcase Idaho Falls " " Do It Best -Stronks and Sons Ashton Do It Best -Yellowstone Rigby El Gene's TV and Appliance Rexburg Falls Plumbing Supply Idaho Falls " Ferguson Enterprises Inc Idaho Falls First Street Plumbing Idaho Falls Home Depot # 1802 Idaho Falls " " " " Lowe's # 1906 Idaho Falls " " Northgate Appliance Idaho Falls " " Rocknacks Hardware Plus Idaho Falls Sanders Furniture Soda Springs Sears #2278 Idaho Falls " " Sears #3290 Rexburg " " Rocky Mountain Power Attachment 2 Page 35 of 112 Case No. PAC-E-16-14 LEDs Fixtures " " .... C: -.:I" 0 ..... (I) 0 C: ] N :~ C: .... :l ~ -0 "' "' (I) .... C: C: C: .... (I) ..... N .... 0 .Q :l (I) u -0 .B (I) Oil ~ 0.. (I) ~ .... .... ] E (.I. µ, :.;: (I) (I) ~ "' -0 E C: ..... (I) 0 <+!, ~ 0 ~ ~ 0 r/) z " " " " " " " " " " " " " " " " Page 3 of9 ... ~ ... <I) ... 0 <I) * <I) ..c:: * :I: 0 "' ... u c:,:t <I) ... ~ ..c:: <I) <I) "' cc > c:,:t "' ~ -~ <I) ~ ..c: ..c: 0 ... 0 "' 0 6 ·c: 0. 0 .... c:,:t 0 > <I) Ul U.l Retailer Citv Thomas Electric & Furniture Malad City ...J ...J True Value #10217 Montpelier U&l Furniture Preston Wolfe Lighting #1 Rexburg Table 3: 2014 Participating Idaho HVAC Trade Allies oil .... c:: C .N <I) c:: E 0 <I) vi 0. ·;;; "O o(! ·5 tu E! C'" C > oil c:: U.l 0 c:: 0. 0 0 0 ] ,...._ ] ... u u <I) 0. <i:: ;::l 0 0. E .;; oil "' <I) E .... u .5 c:: 0 0 ;::l "' .._, ..... u c:,:t ;::l p.., c:: .... .;; o(! E p.., cc _, <I) <I) <I) <I) c:: r;/) > ;::l cc <I) 0 .g oil ·~ µ., <I) ::c ·u .... .5 ::r: 0 .... "' <I) c:,:t :a ;::l .;; 0 c:,:t 0 .... Ci <I) 0. 0 <I) ... Q., C 0 0 r;/) c:,:t ... ;::l .... u .... > ;::l 0 "' 0 U.l 0 r;/) <I) .... ;::l r;/) c:i ~ Ci "O "O C 0. C ;::l E .;; ;::l 0 t: e ... ;::l 0 Q., c:: 0 cc <I) u <I) ::r: Trade Allv Name Citv Alpine Heating & Air ldaho ...J ...J Conditioning Falls Conan Heating, lnc. Idaho ...J Falls DuctzofWA & Post Falls ID/Ductz of Post Falls Excellence Heating & Idaho ...J Cooling Falls First Call Jewel, Inc. Idaho ...J ...J Falls Hallmark Exteriors Ammon Home Energy Experts Clearfield <I) ... ;::l .... )< Li: ...J Rocky Mountain Power Attachment 2 Page 36 of 112 Case No. PAC-E-16-14 ... c:: "'" -<I) 0 0 c:: "ia N .g ... ;; .5 ~ :a "' "' ... c:: c:: c:: ~ ... 0 ..... .e <I) u "O <I) oil <I) Q. <I) ... ;f ... ~ E LI... ~ <I) <I) " "' "O E c:: ~ 0 _, ~ ~ 0 0 r;/) z ...J ...J c:: "'" * -* 0 <I) "' 0 "' 0. ·;;; "O ~ N 7' ... c:,:t <I) ... 0 C <I) > oil ;::l c:: C 0. Ci "' ;::l 0 ;:i C f-; u .e 0. 11. Q. 0. 0. E E E E ;::l E ;::l ;::l ;::l Q., Q., <I) p.., p.., "O cc cc cc <I) cc <I) <I) " <I) <I) ::c ::c ::c ::c 0 z ...J ...J ...J ...J ...J ...J ...J ...J Page4of9 -s:: Q) E Q. ·s CT s:: "1.l 0 ,.-._ ] .... u Q) <I'. ::, 0 0/) "' 0 Q) u .5 .:l 0 '-' u <,I .... .; ~ E Q) Q) Q) > C: r/) ::, .g 0/) -~ i:.r. 0 .5 .... "' :.a ::, .; 0 <,I 0 Q) Q. c., s:: 0 r/) <,I u -> 0 "1.l .... ::, "-< 0 .; .... -s:: Q) u Trade Ally Name City J. Ransom Heating Inc Preston JM Mechanical Hyde Park " Johnson Brothers, Inc Idaho Falls Malad Heating and Malad Cooling LLC City Master Tech LLC Rigby Mountain Valley Heating and Air Wellsville Conditioning Palmer Heating and Idaho Cooling LLC Falls Quantum Engineering Idaho Falls Sermon Service and Idaho Electric Falls Sprinter Heating and Rigby Hydronics Young Electric Heating Idaho and Air Inc Falls 0/) s:: .N s:: 0 Q) ci3 ·;;; -0 ~ .... ~ Q) > s:: C: Q. 0 0 ~ ] u Q. Q. E ] E ::, "' ;:::j Q., s:: 0... 'ca ..... Q) 'ca Q) 0 Q) ::c ·n ::c Q) e 0 Q) .... 0... 0 .... ::, -::, 0 "' 0 r/) Q) r/) ~ -0 -0 s:: Q. s:: ::, E ::, e e ::, c., Q., 0 -<,I Q) ::c * * Rocky Mountain Power Attachment 2 Page 37 of 112 Case No. PAC-E-16-14 C: ""'" -0 Q) "' 0 "' Q. ·;;; -0 ~ N <,I ::, .... .... .5 I Q) 0/) 0 Q) > ::, s:: s:: Q. 0 "' ::, 0 ~ s:: f-, 0 u ci:. Q. ·.:; Q. Q. E E Q. E E ::, ::, E ::, ::, 0... Q., Q) Q., Q., -0 'ca -'ca <,I Q) 'ca Q) Q) p::: Q) Q) ::c ::c ::c ::c 0 z " " " " " " " " " " Page 5 of 9 Rocky Mountain Power Attachment 2 Page 38 of 112 Case No. PAC-E-16-14 Table 4: 2014 Participating Idaho Weatherization Trade Allies "<t" -0 C: N C: C: 0 0 0 ·= -~ ] ] V) V) :i ~ C: ::s ::s 0 .Q V) V) V) -0 ..!: ..!: C: C: 0. -0 .... j E .E 0 .,j <1) 0 ~ -0 <r: 5::: <1) i::i:: Trade Ally Name City z Advanced Insulation Idaho Falls ..J BDI Insulation of Idaho Falls Idaho Falls ..J Bi-State Siding & Window-ID Lewiston ..J BMC West -Idaho Falls Idaho Falls ..J Campbell's Quality Exteriors Idaho Falls ..J Cardall's Insulation -Logan Logan ..J ..J ..J Classic Remodeling Ogden ..J Ductz of WA & ID/Ductz of Post Falls Post Falls ..J Eco Insulation-Idaho Pocatello ..J First Call Jewel, Inc. Idaho Falls ..J Go Green Insulation Caldwell ..J Green Acres Home Improvement Idaho Falls ..J Hallmark Exteriors Ammon ..J Hansen Paint & Glass Preston ..J High Country Glass & Mirror St. Anthony ..J Holeshot Plumbing Ammon ..J Home Energy Experts Clearfield ..J New1 Construction Idaho Falls ..J Precision Glass And Aluminum, Inc. Pocatello ..J Rocky Mountain Insulation-Idaho Pocatello ..J Table 5: Percentage of 2014 Idaho Applications by Category % of Appliance %of %of %of All o/oofHVAC Manufactured % of Kits Customer City Applications & Fixture Applications Homes W eatherization Applications Applications Applications Applications IDAHO FALLS 19.64% 27.37% 35.42% 100.00% 35.19% 17.86% REXBURG 16.84% 11.21% 4.17% 0.00% 7.41% 18.05% RIGBY 12.60% 15.94% 6.25% 0.00% 11.11% 12.06% Page 6 of9 % of Appliance %of All Customer City Applications & Fixture Applications AMMON 8.11% 12.95% SHELLEY 6.10% 5.60% PRESTON 5.00% 4.66% SAINT ANTHONY 4.31% 1.89% MALAD CITY 1.97% 1.46% FIRTH 1.81% 1.60% ASHTON 1.69% 0.58% MONTPELIER 1.50% 0.80% SUGAR CITY 1.39% 1.38% JONA 1.18% 2.40% MENAN 1.16% 1.31% MCCAMMON 0.81% 0.00% UCON 0.78% 1.09% TETON 0.77% 0.29% LAVA HOT 0.73% 0.36% SPRINGS FRANKLIN 0.73% 1.09% WESTON 0.73% 1.02% RIRJE 0.69% 1.09% PARIS 0.60% 0.07% FISH HAVEN 0.59% 0.15% DOWNEY 0.56% 0.22% DUBOIS 0.52% 0.29% ROBERTS 0.52% 0.36% BEAR LAKE WEST 0.50% 0.29% LEWISVILLE 0.49% 0.36% GEORGETOWN 0.47% 0.15% ARCO 0.46% 0.07% SODA SPRINGS 0.46% 0.15% NEWDALE 0.43% 0.15% GRACE 0.42% 0.29% DAYTON 0.38% 0.44% TERRETON 0.38% 0.22% BANCROFT 0.34% 0.00% ARJMO 0.32% 0.22% BLOOMINGTON 0.31% 0.36% PARKER 0.29% 0.15% CLIFTON 0.28% 0.15% %of %ofHVAC Manufactured Applications Homes AppHcations 8.33% 0.00% 12.50% 0.00% 6.25% 0.00% 4.17% 0.00% 2.08% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 2.08% 0.00% 0.00% 0.00% 2.08% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 2.08% 0.00% 0.00% 0.00% 2.08% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 4.17% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% Rocky Mountain Power Attachment 2 Page 39 of 112 Case No. PAC-E-16-14 %of %ofKits W eatherization Applications Applications 3.70% 7.27% 11.11% 6.12% 5.56% 5.06% 7.41% 4.74% 1.85% 2.06% 3.70% 1.85% 0.00% 1.92% 0.00% 1.65% 1.85% 1.40% 0.00% 0.96% 1.85% 1.13% 0.00% 0.96% 0.00% 0.73% 0.00% 0.87% 0.00% 0.81% 0.00% 0.68% 3.70% 0.67% 0.00% 0.63% 0.00% 0.71% 0.00% 0.68% 1.85% 0.60% 0.00% 0.57% 0.00% 0.55% 0.00% 0.55% 1.85% 0.51% 0.00% 0.53% 0.00% 0.53% 0.00% 0.52% 0.00% 0.49% 0.00% 0.45% 0.00% 0.37% 1.85% 0.37% 0.00% 0.41% 0.00% 0.35% 0.00% 0.31% 0.00% 0.32% 0.00% 0.31% Page 7 of9 % of All Customer City Applications HAMER 0.26% BASALT 0.24% BLACKFOOT 0.22% STCHARLES 0.22% BENNINGTON 0.21% MONTEVIEW 0.18% DINGLE 0.14% CHESTER 0.13% OVID 0.13% HOWE 0.12% MARYSVILLE 0.11% SWANLAKE 0.10% KILGORE 0.09% THATCHER 0.09% MUD LAKE 0.08% BERN 0.06% DYKELAKE 0.06% ONYX 0.06% SHARON 0.06% SPENCER 0.06% LANARK 0.04% ALEXANDER 0.03% STONE 0.03% TRAIL CREEK 0.03% BEAR LAKE SD 0.03% CENTRAL 0.03% HOLBROOK 0.03% LIBERTY 0.03% BENCH 0.02% EAST SHORE 0.02% GENEVA 0.02% NlTER 0.02% OXFORD 0.02% ROBIN 0.02% WOOD CANYON 0.02% BLAZER 0.01% CLEVELAND 0.01% FISH CREEK 0.01% % of Appliance %of %ofHVAC Manufactured & Fixture Applications Homes Applications Applications 0.44% 2.08% 0.00% 0.15% 0.00% 0.00% 0.15% 0.00% 0.00% 0.22% 0.00% 0.00% 0.15% 0.00% 0.00% 0.22% 0.00% 0.00% 0.15% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.15% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 2.08% 0.00% 0.07% 0.00% 0.00% 0.07% 0.00% 0.00% 0.07% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 2.08% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% Rocky Mountain Power Attachment 2 Page 40 of 112 Case No. PAC-E-16-14 %of %ofKits Weatherization Applications Applications 0.00% 0.21% 0.00% 0.27% 0.00% 0.24% 0.00% 0.23% 0.00% 0.23% 0.00% 0.17% 0.00% 0.15% 0.00% 0.16% 0.00% 0.16% 0.00% 0.15% 0.00% 0.13% 0.00% 0.12% 0.00% 0.11% 0.00% 0.08% 0.00% 0.09% 0.00% 0.07% 0.00% 0.07% 0.00% 0.07% 0.00% 0.07% 0.00% 0.07% 0.00% 0.05% 0.00% 0.04% 0.00% 0.04% 0.00% 0.04% 0.00% 0.03% 0.00% 0.03% 0.00% 0.03% 0.00% 0.03% 0.00% 0.03% 0.00% 0.03% 0.00% 0.03% 0.00% 0.03% 0.00% 0.03% 0.00% 0.03% 0.00% 0.01% 0.00% 0.01% 0.00% 0.01% 0.00% 0.01 % Page 8 of9 % of Appliance % of All %ofHVAC Customer City Applications & Fixture Applications Applications LEADORE 0.01% 0.00% 0.00% LUND 0.01% 0.00% 0.00% MEADOWVILLE 0.01% 0.00% 0.00% THORNTON 0.01% 0.00% 0.00% TOPAZ 0.01% 0.00% 0.00% TURNER 0.01% 0.00% 0.00% VIRGlNlA 0.01% 0.00% 0.00% EMERALD BEACH 0.01% 0.00% 2.08% %of Manufactured Homes Applications 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% Rocky Mountain Power Attachment 2 Page 41 of 112 Case No. PAC-E-16-14 %of % of Kits W eatherization Applications Applications 0.00% 0.01% 0.00% 0.01% 0.00% 0.01% 0.00% 0.01% 0.00% 0.01% 0.00% 0.01% 0.00% 0.01% 0.00% 0.00% Page 9 of9 A endix 6 Rocky Mountain Power Attachment 2 Page 42 of 112 Case No. PAC-E-16-14 Idaho Program Evaluation Recommendations and Responses Rocky Mountain Power Attachment 2 Page 43 of 112 Case No. PAC-E-16-14 Idaho 2014 Evaluations Program Evaluation Recommendations and Company Responses Evaluation reports provide detailed information on the process and impact evaluations performed on each program, summarizing the methodology used to calculate the evaluated savings as well as providing recommendations for the Company to consider for improving the process or impact of the program, as well as customer satisfaction. Outlined below is a list of the programs, the years that were evaluated during 2014 and the third party evaluator who completed the evaluation. Program evaluations are available for review at www.pacificorp.com/es/ dsm/idaho.html Program Years Evaluated Evaluator Home Energy Savings 2011-2012 The Cadmus Group Company responses to the program recommendations contained in the 2011 -2012 evaluations are provided below. The third party evaluator's recommendations and Company's responses are provided m the below Tables: Table 1 Home Energy Savings Evaluation Recommendations Evaluation Recommendations Rocky Mountain Power Action Plan In order to remain consistent with the Uniform The program uses commercially available baselines Methods Project (UMP), Cadmus recommends as recommended by the Uniform Methods Project using the lumen equivalency methodology outlined to determine the baseline for each replacement CFL in UMP protocol to determine baseline wattages for and LED wattage; savings are determined per lamp future program years. based on this replacement data. Commercially available baselines are determined using both the recommended lumen output buckets as indicated by ENERGY ST AR as well as actual program data gathered from redeemed bulbs. To further enhance the program administrator's The data used in the retail sales allocation tool, methodology for calculating and minimizing CFL which is used to minimize leakage, is reviewed on leakage, review the confidence surrounding a regular basis to ensure accurate mapping of store geocoded addresses to ensure that store locations locations and utility service territory. are accurately mapped. Also, consider using Rocky Mountain Power's actual service area territory Evaluation Recommendations boundary to refine the model. Review options for how best to understand and track the impact of EISA for 60-and 40-watt bulbs in 2014. Some states have allowed utilities to stagger changing the baseline for bulbs impacted by EISA. In order to reduce the number of rejected applications, incorporate as many of the best practices stated in Appendix M into the HES incentive fonns as deemed cost-effective. Cadmus suggests prioritizing the following: -Keep the incentive form length to a minimum. -Encourage trade allies to fill out the paperwork through training or bonuses to decrease the number of rejected applications. -Utilize a paperless application process for all incentive applications. Rocky Mountain Power Attachment 2 Page 44 of 112 Case No. PAC-E-16-14 Rocky Mountain Power Action Plan The program continues to monitor bulbs sales to understand trends in the market. Paperless online incentive applications are available for all appliance measures. Paper based incentive applications have been revised and are now shorter. Training trade allies on filling out paperwork correctly is ongoing. ~~\;,~OUNTAIN Aooendix 7 wattsmart Business Trade Allies 2014 Rocky Mountain Power Attachment 2 Page 45 of 112 Case No. PAC-E-16-14 Energy Efficiency Alliance Rocky Mountain Power Attachment 2 Page 46 of 112 "WROCKY MOUNTAIN ~POWER The following is a list of contractors, distributors and other businesses participating in Rocky Mountain Power's Energy Efficiency Alliance displayed in random order (unless sorted by the user) based on the search criteria selected. This listing is provided solely as a convenience to our customers. Rocky Mountain Power does not warrant or guarantee the work performed by these participating vendors. You are solely responsible for any contract with a participating vendor and the performance of any vendor you have chosen. An asterisk (*) indicates Rocky Mountain Power Outstanding Contribution Award winning trade allies in 2009, 2010, 2011, 2012 and/or 2013. Search Criteria: Selected State(s): Specialties: Business Type: Idaho Lighting HVAC -unitary HVAC -evaporative Motors and VFDs Controls Building envelope Appliances Office Equipment Food Service Compressed Air Farm and Dairy Irrigation Other --ANY-- Search Results: 107 -Date and Time: 04/23/2015 10:55:24 AM Northern Lights Electric LLC* Specialties Business Type Lighting Contractor 3473 E. 20th N. Unit A Idaho Falls, ID -83401 Phone: 208-757-9473 American Mechanical Sysytems Specialties Business Type Service, LLC Controls Contractor HVAC -unitary 7530 South State Street Motors and VFDs Midvale, UT -84047 Phone: 801-428-0400 Website: www.ams-ut.com Young Electric, Heating & Air, inc. Specialties Controls Business Type Contractor 1573 W. Suniside Road HVAC -evaporative Idaho Falls,, I -83402 HVAC -unitary Phone: 208-357-1899 Lighting Website: www.youngehainc.com DesignTek Consulting Group, LLC Specialties Business Type Compressed Air Contractor 1600 W. 2200 S. Controls Engineering Firm Salt Lake Ci~, UT -84119 HVAC -evaporative Phone: 801-55-5449 HVAC -unitary Website: www.designtekconsulting.com Lighting Motors and VFDs Spectrum Energy Solutions Specialties Business Type Farm and Dairy Contractor 8050 N Palm Ave Irrigation Engineering Firm #106, Motors and VFDs Other: consultant Fresno, CA -93711 Other: Other Specialty Phone: 559-438-2700 Website: www.spectrum-nrg.com Green Planet Company Specialties Business Type Appliances Distributor 63 East 11400 South #257 HVAC -evaporative Manufacturer -Rep Sandy , UT -84070 HVAC -unitary Phone: 801-980-1518 Lighting Website: Motors and VFDs www.greenplanetcompany.com Compressor -Pump & Service, Inc. Specialties Business Type Compressed Air Distributor 3333 W. 2400 S. Salt Lake City, UT -84119 Phone: 801-973-0154 Website: www.compressor-pump.com Join Date 04/01/2009 Join Date 11 /30/2012 Join Date 12/03/2014 Join Date 11 /11/2013 Join Date 04/10/2014 Join Date 05/07/2014 Join Date 10/21/201 3 C2014 Rocky Mountain Power, a dlvl1Jon of PacifiCorp and part of MidAmerican Energy Holdings Company Projects Completed 8 Projects Completed Projects Completed Projects Completed Projects Completed Projects Completed Projects Completed Rocky Mountain Power Attachment 2 Page 4 7 of 112 Energy Efficiency Alliance ~ROCKY MOUNTAIN POWER Gustave A. Larson Company Specialties Business Type Join Date Projects HVAC -unita~ Distributor 09/01/2008 Completed 1395 Northgate Mile Motors and V Os Idaho Falls, ID -83401 Phone: 208-522-3270 Website: galarson.com RME, Inc Specialties Business Type Join Date Projects Controls Contractor 10/14/2014 Completed 8685 W State St Lighting Engineering Firm Boise, ID -83714 Phone: 208-853-2968 Website: rmeinc.net Bastion Technologies, LLC Specialties Business Type Join Date Projects Lighting Distributor 07/30/2014 Completed 175 W 7065 S Manufacturer -Rep 12 Midvale, UT -84047 Other: consultant Phone: 800-328-6024 Website: www.bastiontech.com Harris Mechanical lntermountain Specialties Business Type Join Date Projects HVAC -evaporative Contractor 01 /27/2014 Completed 1925 South Milestone Drive HVAC -unitary Suite E, Salt Lake City, UT -84104 Phone: 801-433-2640 Website: www.hmcc.com Electrical Wholesale Supply Co., Inc. Specialties Business Type Join Date Projects -Corporate Controls Distributor 09/22/2012 Completed Lighting null 1355 Fremont Ave Motors and VFDs Idaho Falls, ID -83405 Phone: 208-523-2901 Website: www.ewscoinc.com Candle3 LLC Specialties Business Type Join Date Projects Controls Distributor 11/21/2014 Completed 6385 Corporate Dr. Lighting Manufacturer -Rep Colorado Springs, CO -80919 Phone: 719-930-9099 Website: www.candle3.com Consolidated Electrical Distributors* Specialties Business Type Join Date Projects -Logan, UT Farm and Dairy Distributor 03/26/2005 Completed Irrigation 58 636 N. 600W. Lighting Logan, UT -84321 Phone: 435-752-8905 Pacheco Company LLC Specialties Business Type Join Date Projects Lighting Contractor 02/12/2015 Completed 3646 E. Summer Hill Other: Other Specialty Distributor Salt Lake City, UT -84121 Manufacturer -Rep Phone:801-541-3375 Website: www.pachecoco.com Architectural Nexus, Inc. Specialties Business Type Join Date Projects Appliances Architect 08/18/2014 Completed 2505 East Parleys Way Building envelope Salt Lake City, UT -84109 Controls Phone: 801-924-5000 HVAC -evaporative Website: www.archnexus.com HVAC -unitary Lighting Motors and VFDs Office Equipment H-C Design & Consulting Specialties Business Type Join Date Projects Food Service Manufacturer -Rep 07/01/2013 Completed P.O. Box 10545 Bozeman, MT -59719 Phone: 406-522-7700 Network Consulting Services, inc. Specialties Business Type Join Date Projects Office Equipment Architect 04/29/2013 Completed 563 West 500 South Contractor Suite 245, Engineering Firm Bountiful, UT -84010 Manufacturer -Rep Phone: 801-295-7555 Website: http://www.ncsi.us 02014 Rocky Mountain Power, a division of PacifiCorp and part of MidAmerican Energy Holdings Company Rocky Mountain Power Attachment 2 Page 48 of 112 Energy Efficiency Alliance ~ROCKY MOUNTAIN POWER Alloway Commercial Lighting Specialties Business Type Join Date Projects Lighting Distributor 09/26/2012 Completed 1420 Grove Street 1 Boise, ID -83702 Phone: 208-344-2507 Website: www.allowaylighting.com PVE, Inc Specialties Business T~pe Join Date Projects Controls Engineering irm 07/29/2013 Completed 1040 North 2200 West, Suite 100 HVAC -evaporative Salt Lake City, UT -84107 HVAC -unitary Phone: 801-359-3158 Lighting Motors and VFDs Utah Yamas Controls Inc.• Specialties Business Type Join Date Projects Building envelope Contractor 01/21/2013 Completed 13526S.110W. Controls Distributor Draper, UT -84020 HVAC -evaporative Engineering Firm Phone: 801-990-1950 HVAC -unitary Manufacturer -Rep Website: www.utahyamas.com Lighting Motors and VFDs Other: Other Specialty Green Creative LLC Specialties Business Type Join Date Projects Lighting Manufacturer -Rep 06/25/2013 Completed 533 Airport Blvd., Suite 212 Burlingame, CA -94010 Phone: 866-774-5433 Website: www.gc-lighting.com Harris Lighting Products Specialties Business Type Join Date Projects Lighting Distributor 04/01/2007 Completed 1405 W. 800 N. Manufacturer -Rep 41 Preston, ID -83263 Phone: 208-852-2890 Norbryhn Equipment Company Specialties Business Type Join Date Projects HVAC -unita~ Distributor 05/01/2012 Completed 3711 E. Newby St. Motors and V Ds Nampa, ID -83687 Phone: 208-465-5700 Website: norbryhn.com Valley Implement Specialties Business Type Join Date Projects Controls Contractor 12/05/2012 Completed 213 West 8th North Irrigation null Preston, ID -83263 Motors and VFDs Phone: 208-852-0430 Website: valley-implement.com Titan LED -North Logan Specialties Business Type Join Date Projects Lighting Manufacturer -Rep 07/08/2014 Completed 641 E 2200 N 4 North Logan, UT -84341 Phone: 801-784-8260 Website: www.titanled.net Lennox* Specialties Business Type Join Date Projects HVAC -unitary Distributor 11/01/2005 Completed 1008 W 2780 S Salt Lake City, UT -84119 Phone: 801-556-6114 Website: lennoxcommercial.com Allred's Incorporated -Logan Specialties Business Type Join Date Projects HVAC -unitary Distributor 05/11/2011 Completed 642 North 1000 West Unit # 104 Logan, UT -84321 Phone: 435-774-1200 Website: www.allreds.net Patriot Electric, Heating & Air Inc. Specialties Business Type Join Date Projects Controls Contractor 08/26/2014 Completed 1347 E 1500 N Lighting 1 Terreton, ID -83450 Motors and VFDs Phone: 208-680-7345 Website: www.facebook.com/PtriotElectricHeatin gAir c201, Rocky Mountain Power, a division of PacffiCorp and part of MidAmerican En•rgy Holdings Company ------·---- Rocky Mountain Power Attachment 2 Page 49 of 112 Energy Efficiency Alliance ~ROCKY MOUNTAIN POWER Loeb Lighting Services Specialties Business Type Join Date Projects Controls Distributor 03/16/2015 Completed 1800 E 5th Ave Lighting Columbia, OH -43219 Phone: 800-866-5616 JRW & Associates, PLLC Specialties Business Type Join Date Projects Building envelope Architect 10/21/2013 Completed 1152 Bond Ave Rexburg, ID -83440 Phone: 208-359-2309 Advanced Lighting, Inc. -Idaho Specialties Business Type Join Date Projects Lighting Distributor 04/28/2014 Completed 3099 south 1030 west 1 Salt Lake City, UT -84119 Phone: 801-972-9530 Codale Electric Supply, Inc -Casper Specialties Business Type Join Date Projects Lighting Distributor 06/27/2013 Completed 3131 Wood Court 1 Casper, WY -82601 Phone: 702-261-8900 Website: www.codale.com Cooper Lighting Specialties Business Type Join Date Projects Controls Manufacturer -Rep 12/13/2012 Completed 1121 Highway 74 South Lighting Peachtree, GA -30269 Phone: 770-486-3092 Website: www.cooperlighting.com Electrical Wholesale Supply Co., Inc. Specialties Business Type Join Date Projects -Rexburg Controls Distributor 09/22/2012 Completed Lighting 20 899 Jetstream Dr. Motors and VFDs Rexburg, ID -83440 Phone: 208-356-7282 Website: www.ewscoinc.com Verismic Software Inc. Specialties Business Type Join Date Projects Office Equipment Contractor 01/16/2013 Completed 65 Enterprise Other: Other Specialty Distributor Aliso Viejo, CA -92656 Manufacturer -Rep Phone: 949-270-1903 x 4 736 Other Website: www.verismic.com Smart Building Solutions Specialties Business Type Join Date Projects Building envelope Distributor 03/04/2015 Completed 2876 South 460 West Controls Manufacturer -Rep Salt Lake City, UT -84115 HVAC -evaporative Phone: 801-733-6000 HVAC -unitary Website: www.intellivex.com Lighting Motors and VFDs Office Equipment Other: Other Specialty American Electric Company, Inc. Specialties Business Type Join Date Projects Appliances Contractor 04/06/2015 Completed 78 West 13775 South, Suite 9 Building envelope Draper, UT -84020 Controls Phone: 801-254-0782 Lighting Website: www.americanelectric.cc Motors and VFDs Other: Other Specialty Mark Clary Specialties Business Type Join Date Projects Lighting Architect 08/08/2013 Completed 2302 West 8540 South West Jordan, UT -84088 Phone: 801-233-0882 Electrical Wholesale Supply Co., Inc. Specialties Business Type Join Date Projects -Driggs Controls Distributor 09/22/2012 Completed Lighting 21 83C Rocky Road Ind Lp. Motors and VFDs Driggs, ID -83422 Phone: 208-354-1228 Website: www.ewscoinc.com e>201• Rocky Mountain Power, a division of PacifiCorp and part of MidAmeric.n Energy Holdings Company Rocky Mountain Power Attachment 2 Page 50 of 112 Energy Efficiency Alliance ~ROCKY MOUNTAIN POWER Conan's Inc. Specialties Business Type Join Date Projects Controls Contractor 02/12/2015 Completed 429 W. 18th Street HVAC -evaporative P.O. Box 2253, HVAC -unitary Idaho Falls, ID -83402 Phone: 208-522-3372 Rocky Mountain Electric -Idaho Specialties Business Type Join Date Projects Falls Lighting Contractor 08/27/2014 Completed 6698 N. 25th E Idaho Falls, ID -83401 Phone: 208-587-9682 x 6 Precision-Paragon [P2] Specialties Business Type Join Date Projects Lighting Manufacturer -Rep 03/13/2013 Completed 23281 La Palma Ave Other: Manufacturer Yorba Linda, CA -92887 Phone: 714-386-5550 Website: www.p-2.com Restaurant and Store Equipment Specialties Business Type Join Date Projects Company Appliances Distributor 10/15/2013 Completed Food Service 230 West 700 South Salt Lake City, UT -84101 Phone: 801-364-1981 Website: rescoslc.com Clark's Quality Roofing, Inc. Specialties Business Type Join Date Projects Building envelope Contractor 09/19/2012 Completed 334 W. Anderson Avenue Salt Lake City, UT -84107 Phone: 801-266-3575 Website: clarkroof.com Nulite Electric LLC Specialties Business Type Join Date Projects Controls Contractor 08/26/2014 Completed 3570 Brookfield Ln. Lighting Ammon, ID -83406 Motors and VFDs Phone: 208-680-9990 Website: nourlsited.org Royal Engineering, Inc. Specialties Business T~pe Join Date Projects Building envelope Engineering irm 12/31/2014 Completed 2335 S. State Street Controls Suite 100, HVAC -evaporative Provo, UT -84606 HVAC -unitary Phone: 801-375-2228 Lighting Website: www.royaleng.com Motors and VFDs Engineered Systems Assoc., Inc. Specialties Business T~pe Join Date Projects Controls Engineering irm 01/10/2014 Completed 1355 E. Center Street HVAC -evaporative Pocatello, ID -83201 HVAC -unita~ Phone: 208-233-0501 Motors and V Ds Hatch Lighting Specialties Business Type Join Date Projects Lighting Distributor 05/06/2014 Completed 4133N45E 2 Idaho Falls, ID -83401 Phone: 208-200-3000 Bradley Engineering Specialties Business T~pe Join Date Projects Lighting Engineering irm 09/22/2012 Completed 382 Walnut Street 8 Idaho Falls, ID -83402 Phone: 208-523-2862 Website: www.bradleyengineering.com Electrical Equipment Company Specialties Business Type Join Date Projects Lighting Contractor 01/01/2012 Completed 540 W. 20th St. Other: Other Specialty 1 Idaho Falls, ID -83402 Phone: 208-522-4732 Website: electricalequipment.com Engineering Economics, Inc. Specialties Business T~pe Join Date Projects Building envelope Engineering irm 01/20/2014 Completed 780 Simms Street Suite 210 Controls Golden, CO -80401 HVAC -evaporative Phone: 800-869-6902 HVAC -unitary C)201' Rocky Mountain Power, a division of PacifiCorp and part of MidAmerican Energy Holdings Company Rocky Mountain Power Attachment 2 Page 51 of 112 Energy Efficiency Alliance ~ROCKY MOUNTAIN POWER Van Boerum & Frank Associates Specialties Business Type Join Date Projects Building envelope Architect 01/01/2012 Completed 330 South 300 East Controls Engineering Firm Salt Lake City, UT -84111 HVAC -evaporative Other Phone: 801-530-3148 HVAC -unitary Website: www.vbfa.com Lighting Motors and VFDs Honeywell International Specialties Business Type Join Date Projects Controls Contractor 05/01/2006 Completed 2371 S. Presidents Way Suite A HVAC -evaporative Distributor Salt Lake City, UT -84120 HVAC -unita~ Manufacturer -Rep Phone: 801-978-7136 Motors and V Os Website: honeywell.com Mountain West Mechanical Specialties Business Type Join Date Projects HVAC -evaporative Contractor 03/17/2014 Completed 2336 W. 5200 S. HVAC -unitary Rexburg, ID -83440 Phone: 208-356-0370 Website: www.mountainwestmechanical.com Lewis Corporation• Specialties Business Type Join Date Projects HVAC -unitary Contractor 08/01/2008 Completed 15136 Hunziker Pocatello, ID -83202 Phone: 208-238-1202 Website: !corp.com Electrical Wholesale Supply Co., Inc. Specialties Business Type Join Date Projects -Blackfoot Controls Distributor 09/22/2012 Completed Lighting null 560 Jensen Grove Rd. Motors and VFDs Blackfoot, ID -83221 Phone: 208-542-4995 Website: www.ewscoinc.com Electrical Marketing Solutions (DBA) Specialties Business Type Join Date Projects EMS Controls Manufacturer -Rep 12/31/2014 Completed 2139 S West Temple Lighting Salt Lake City, UT -84115 Phone: 801-869-1445 Website: http://emsreps.com/ LEPCO (Leonard Petroleum Specialties Business Type Join Date Projects Equipment) Lighting Contractor 09/24/2012 Completed P.O. Box 170219 2 Boise, ID -83717 Phone: 208-336-1155 Coolerado Corporation Specialties Business Type Join Date Projects HVAC -evaporative Distributor 03/01/2007 Completed 4700 W. 60th Ave., Ste. 3 HVAC -unitary Manufacturer -Rep Arvada, CO -80003 Phone: 303-375-0878 Website: coolerado.com Electrical Wholesale Supply Co., Inc. Specialties Business Type Join Date Projects -Pocatello Controls Distributor 09/22/2012 Completed Lighting null 220 West Maple Motors and VFDs Pocatello, ID -83206 Phone: 208-233-1362 Website: www.ewscoinc.com Hussmann Corporation Specialties Business Type Join Date Projects Controls Manufacturer -Rep 01/14/2015 Completed 1385 W 2200 St Food Service Salt Lake City, UT -84119 HVAC -evaporative Phone: 805-458-7615 HVAC -unitary Website: hussmann.com Lighting Motors and VFDs 02014 Rocky Mountain Power, a division of PacfflCorp and part of MidAmerican Energy Holdings Company Rocky Mountain Power Attachment 2 Page 52 of 112 Energy Efficiency Alliance ~ROCKY MOUNTAIN POWER Wheeler Electric Specialties Business Type Join Date Projects Building envelope Contractor 01/01/2007 Completed 469 West 16th St. Compressed Air 5 Idaho Falls, ID -83402 Controls Phone: 208-522-1906 Farm and Dairy Website: wheelerelectric.com Food Service Lighting Motors and VFDs Green Light National, LLC Specialties Business Type Join Date Projects Lighting Contractor 02/18/2015 Completed 1001 South 400 East Distributor 23 Orem, UT -84077 Phone: 801-722-8677 Website: www.greenlightnational.com HD Supply Facilities Maintenance, Specialties Business Type Join Date Projects Ltd. Appliances Distributor 01/22/2014 Completed 10641 Scripps Summit Court HVAC -evaporative San Diego, CA-92131 HVAC -unitary Phone: 858-831-2231 Website: www.hdsupplysolutions.com High Country Heating Specialties Business Type Join Date Projects HVAC -evaporative Contractor 06/18/2014 Completed 3939 E 240 N HVAC -unitary Rigby, ID -83442 Phone: 208-745-7021 Website: www.modernphe.com Electrical Wholesale Supply Co., Inc. Specialties Business Type Join Date Projects -Home Lighting Controls Distributor 09/22/2012 Completed Lighting null 650 W. Sunnbside Rd. Motors and VFDs Idaho Falls, I -83402 Phone: 208-523-2300 Website: www.ewscoinc.com Tirrell's Electric, Inc. Specialties Business Type Join Date Projects Lighting Contractor 03/01/2009 Completed 770 E. Sunnflside Rd. 1 Idaho Falls, D -83404 Phone: 208-524-2456 Royal Wholesale Electric -Logan Specialties Business Type Join Date Projects Lighting Distributor 01/09/2008 Completed 917 W 600 N Ste 101 15 Logan, UT -84321 Phone: 435-752-7692 Website: royalutah.com Felt Lighting Inc. Specialties Business Type Join Date Projects Controls Distributor 11/27/2013 Completed 1220 East 3300 South Lighting 1 Salt Lake City, UT -84106 Phone: 801-484-8571 Website: www.feltlighting.com Sika Sarnafil Incorporated* Specialties Business Type Join Date Projects Building envelope Contractor 11/01/2011 Completed 2881 South 900 West Salt Lake City, UT-84119 Phone: 801-575-8648 Website: usa.samafil.sika.com Colvin Engineering Associates, Inc. Specialties Business Type Join Date Projects Controls Architect 04/29/2013 Completed 244W 300 N HVAC -evaporative Engineering Firm Suite 200, HVAC -unitary Salt Lake Ci~, UT -84103 Other: Other Specialty Phone: 801-22-2400 GE Specialties Business Type Join Date Projects Controls Manufacturer -Rep 09/04/2014 Completed 664 East 1300 North Lighting Pleasant Grove, UT -84062 Phone: 801-785-8838 Website: www.gelighting.com CC>2014 Rocky Mountain Power,• division of PacifiCorp and part of MidAmerican Energy Holdings Company Rocky Mountain Power Attachment 2 Page 53 of 112 Case Nn PAC-E-16-14 Energy Efficiency Alliance ~ROCKY MOUNTAIN POWER DiVi Energy, LLC Specialties Business Type Join Date Projects Lighting Manufacturer -Rep 01/23/2013 Completed 191 North 290 West Other 60 Lindon, UT -84042 Phone: 801 -243-1811 Valley Implement Specialties Business Type Join Date Projects Controls Contractor 12/05/2012 Completed 2570 N Main Farm and Dairy null Logan, UT -84341 Irrigation Phone: 435-787-1586 Motors and VFDs Website: valley-implement.com LDP Associates Inc. Specialties Business Type Join Date Projects Architect 06/27/2014 Completed 3908 Smith Ranch Rd Other: Other Specialty Engineering Firm Eagle Mountain, UT -84005 Manufacturer -Rep Phone: 801-597-0618 Website: http://www.ldpassociates.com/ D&S Electrical Specialties Business Type Join Date Projects Lighting Distributor 12/01/2008 Completed 363 West Chubbuck Road Motors and VFDs 43 Pocatello, ID -83202 Phone: 208-731-3701 BKJ Holdings, LLC Specialties Business Type Join Date Projects Lighting Distributor 01/06/2015 Completed 3458 E Fairway Lane Manufacturer -Rep Spanish Fork, UT -84660 Phone: 801-636-5969 Ovation Engineering & Consulting Specialties Business T~pe Join Date Projects Controls Engineering irm 12/08/2014 Completed 1113 N Victoria Way Lighting Salt Lake City, UT -84116 Phone: 801-871-0900 D.W. Electric Specialties Business Type Join Date Projects Lighting Contractor 05/01/2011 Completed 4565 E. 75th N. 1 Rigby, ID -83442 Phone: 208-681-7006 VESCO LLC -Young Electric Sign Specialties Business Type Join Date Projects Co. -Salt Lake City, UT Appliances Contractor 09/22/2012 Completed Controls Manufacturer -Rep 62 1605 S. Gramercf Road Lighting Salt Lake City, U -84104 Motors and VFDs Phone: 801-464-6454 Website: www.yesco.com All American Lighting Inc. Specialties Business Type Join Date Projects Lighting Distributor 03/01 /2010 Completed P.O. Box 2996 4 Idaho Falls, ID -83206 Phone: 208-237-2164 WHW Engineering Inc. Specialties Business T~pe Join Date Projects HVAC -evaporative Engineering irm 02/23/2015 Completed 8619 Sandy Parkway #101 HVAC -unitary Sandy, UT -84070 Motors and VFDs Phone: 801-466-4021 Electrical Wholesale Supply Co., Inc. Specialties Business Type Join Date Projects -Idaho Falls Lighting Distributor 09/22/201 2 Completed 3140 McNeil Dr. 20 Idaho Falls, ID -83402 Phone: 208-523-2800 Website: www.ewscoinc.com Pete's Lighting Specialties Business Type Join Date Projects Lighting Distributor 09/01/2010 Completed 227 S. Johnson Ave. 1 Pocatello, ID -83204 Phone: 208-233-0220 ()2014 Rocky Mountain Power, a division of PacifiCorp and part of MidAmerican Energy Holdings Company Rocky Mountain Power Attachment 2 Page 54 of 112 Energy Efficiency Alliance ~ROCKY MOUNTAIN POWER Bateman-Hall, Inc.* Specialties Business Type Join Date Projects Contractor 02/18/2014 Completed 1405 Foote Drive Other: Other Specialty Idaho Falls, ID -83402 Phone: 208-523-2681 Website: www.bateman-hall.com Consolidated Electrical Distributors* Specialties Business Type Join Date Projects -Idaho Falls Lighting Distributor 09/24/2012 Completed 865 Pancheri 14 Idaho Falls, ID -83402 Phone: 208-523-2022 Catalyst LED Lighting Solutions Specialties Business Type Join Date Projects Lighting Distributor 05/01 /2014 Completed 2817 N 12th St Manufacturer -Rep Coeur d Alene, ID -83815 Phone: 480-789-3773 Website: http://www.catalystleds.com Optica Energy Management, LLC Specialties Business Type Join Date Projects HVAC -unitary Distributor 04/11/2013 Completed 1772 Ross Dr Lighting Other: Energy 11 Ogden, UT -84403 Motors and VFDs Management Phone: 888-442-4866 Company Website: www.opticaenergy.com Engineering System Solutions OBA Specialties Business T~pe Join Date Projects ES2 Appliances Engineering irm 05/08/2014 Completed 4943 N 29 E Suite A Building envelope Controls Idaho Falls, ID -83401 HVAC -evaporative Phone: 208-552-9874 HVAC -unitary Website: www.es2eng.com Lighting Motors and VFDs Electrical Support Services LLC Specialties Business Type Join Date Projects Farm and Dairy Contractor 03/12/2015 Completed 1037 E 1400 N. lrriiation Shelly, ID -83274 Lig ting Phone: 208-251~022 Motors and VFDs Platt Electric Supply* -Idaho Falls Specialties Business Type Join Date Projects Controls Distributor 01 /01 /2009 Completed 919 Pancheri Street Lighting 11 Idaho Falls, ID -83402 Motors and VFDs Phone: 208-524~171 Case, Lowe & Hart, Inc. Specialties Business Type Join Date Projects Building envelope Architect 05/17/2013 Completed 2484 Washington Blvd. Compressed Air Engineering Firm Suite 510, Controls Ogden, UT -84401 HVAC -evaporative Phone: 801-399-5821 HVAC -unitary Website: www.clhae.com Lighting Motors and VFDs Town & Country Electric, Inc. Specialties Business Type Join Date Projects Lighting Contractor 01 /01 /2009 Completed 1223 11th Ave. North Nampa, ID -83687 Phone: 208-467-2148 Website: town-and-country-electric.com Midgley-Huber, Inc.* Specialties Business Type Join Date Projects HVAC -evaporative Manufacturer -Rep 05/01 /2007 Completed 2465 Progress Drive HVAC -unitary Salt Lake City, UT -84119 Phone: 801-972-5011 Website: Migley-huber.com Trane* Specialties Business Type Join Date Projects Controls Distributor 03/01 /2005 Completed 2817 S. 1030 W. HVAC -unitary Manufacturer -Rep Salt Lake City, UT -84119 Motors and VFDs Phone: 801-486-0500 Website: www.trane.com C2014 Rocky Mountain Power, a division of PacifiCorp and part of MidAmerican Energy Holdlnga Company Rocky Mountain Power Attachment 2 Page 55 of 112 Energy Efficiency Alliance ~ROCKY MOUNTAIN POWER Energy Management Corporation• Specialties Business Type Join Date Projects HVAC -unitary Distributor 05/01/2004 Completed 501 West 700 South Motors and VFDs Salt Lake City, UT -84101 Phone: 801-366-4100 Website: emcsolutions.com Johnson Controls, Inc.• Specialties Business Type Join Date Projects Controls Contractor 06/01/2007 Completed 2255 Technology Parkway HVAC -evaporative Manufacturer -Rep West Valley City, UT -84119 HVAC -unitary Phone: 801-946-4059 Motors and VFDs ESL Vision LLC Specialties Business Type Join Date Projects Controls Distributor 01/13/2013 Completed P.O. Box 58565 Lighting Manufacturer -Rep Salt Lake City, UT -84102 Phone:801-415-5177 Website: www.eslvision.com McKinstry Essention, LLC Specialties Business T~pe Join Date Projects Building envelope Engineering irm 02/12/2014 Completed 112 N. Rubey Dr. Compressed Air Suite 200, Controls Golden, CO -80403 HVAC -evaporative Phone: 435-632-8433 HVAC -unitary Website: www.mckinstry.com Irrigation Lighting Motors and VFDs Other: Other Specialty Skyview Electric Inc Specialties Business Type Join Date Projects Lighting Contractor 02/01/2009 Completed 2299 W Omni Dr Idaho Falls, ID -83402 Phone: 208-542-0321 RealWinWin, Inc. Specialties Business Type Join Date Projects Appliances 10/14/2013 Completed 1926 Arch Street, 4F Building envelope Other: Energy 6 Philadelphia, PA-19103 Controls Efficiency Incentive Phone: 215-732-4480 x 349 Food Service Administration and Website: www.realwinwin.com HVAC -evaporative Consultation HVAC -unitary Lighting Motors and VFDs Office Equipment Eco Safe Lighting Specialties Business Type Join Date Projects Lighting Distributor 02/11/2013 Completed 4600 NW Camas Meadows Drive, Suite 210 Camas, WA -98607 Phone:360-567-1923 Website: http://www.est- lights.com/about-us/ TreeFrog LED, Inc. Specialties Business Type Join Date Projects Lighting Distributor 07/29/2013 Completed 7594 North Swansea Court Eagle Mountain, UT -84005 Phone: 801-372-8720 Website: www.treefrogled.com Aspen Engineering and Specialties Business T~pe Join Date Projects Environmental LLC Building envelope Engineering irm 03/18/201 3 Completed Controls 140 Aspen Circle HVAC -evaporative Park City, UT -84098 HVAC -unitary Phone: 435-565-1535 Lighting Website: www.a2e-llc.com Motors and VFDs Total Energy Electrical/Full Specialties Business Type Join Date Projects Spectrum Services Lighting Contractor 10/11/2012 Completed 121 E. 38th, #106 null Boise, ID -83714 Phone: 208-622-9977 Website: www.fullspecservices.com C>2014 Rocky Mountain Power, a division of PacifiCorp and part of MidAmerican Energy Holdings Company Energy Efficiency Alliance Larsen Electric, LLC P.O. Box 2871 Pocatello, ID -83206 Phone: 208-237-2058 Specialties Lighting Business Type Contractor Join Date 09/22/2012 Rocky Mountain Power Attachment 2 Page 56 of 112 ... ROCKY MOUNTAIN ~POWER Projects Completed 1 ,C,2014 Rocky Mountain Power, a division of PacifiCorp and part of MidAmerican Energy Holdlnga Company ~~\;,~OUNTAIN Aooendix 8 Energy Efficiency Measures for Idaho Rocky Mountain Power Attachment 2 Page 57 of 112 Case No. PAC-E-16-14 Program : Home Energy Savings ~easure Category : Appliances Clothes Washers:Clothes Washer -Electric DHW & Electric Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Residential lathes Washer -3.2 MEF or Higher -Electric DHW & Electric Dryer· ID !Energy efficient clothes washer 04/14/2014 Clothes Washers:Clothes Washer -Electric DHW & Gas Dryer lathes Washer -3.2 MEF or Higher -Electric DHW & Gas Dryer -ID Clothes Washers:Clothes Washer -Gas DHW & Electric Dryer lathes Washer - 3.2 MEF or Higher -Gas DHW & Electric Dryer -ID Clothes Washers:Clothes Washer -Gas DHW & Gas Dryer lathes Washer -3.2 MEF or Higher -Gas DHW & Gas Dryer -ID Freezers:Freezer reezer -20%+ better than Federal Standard -Any Style -ID Refrigerators:Refrigerator CEE Tier 3 [Refrigerator -CEE Tier 3 -Any Style -ID ~easure Category : Bulldlng Shell lnsulation:Attic Insulation nsulation -Attic -Electric FAF Heating System -ID !Insulation -Attic -Electric Heat Pump Heating System -ID :insulation -Attic -Electric Zonal Heating System -ID :insulation -Attic -Gas Heat with CAC -ID [Insulation -Attic -Self Install -Electric FAF Heating System -ID [Insulation -Attic -Self Install -Electric Heat Pump Heating System -ID [Insulation -Attic -Self Install -Electric Zonal Heating System -ID nsulation -Attic -Self Install -Gas Heat with CAC -ID lnsulation:Floor Insulation [Insulation -Floor -Electric FAF Heating System -ID [Insulation -Floor -Electric Heat Pump Heating System -ID [Insulation -Floor -Electric Zonal Heating System -ID Residential nergy efficient clothes washer Residential ,Energy efficient clothes washer Residential :Energy efficient clothes washer Residential nergy efficient freezer Residential ~nergy efficient refrigerator Residential Install attic insulation -Contractor nstall attic insulation -Contractor [Install attic insulation -Contractor [Install attic insulation -Contractor Install attic insulation -Self-install :install attic insulation -Self-install nstall attic insulation -Self-install nstall attic insulation -Self-install Residential :install floor insulation -Contractor Install floor insulation -Contractor nstall floor insulation -Contractor Report Date: 04/27/2015 04/14/2014 04/14/2014 04/14/2014 08/20/2012 08/20/2012 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 Energy Savings Calculation method RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed Page 1 of 55 Rocky Mountain Po'Ner Attachment 2 Page 58 of 112 Case No. PAC-E~16--14 Gross incremental annual electric savings (kWh/yr) Savings unit 143 Measure 54 Measure 106 Measure 16 Measure 94.4 Measure 85.8 Measure 1.35 Sq. ft. 1 Sq. ft. 1.19 Sq. ft. 0.01 Sq. ft. 1.35 Sq. ft. 1 Sq. ft. 1.19 Sq. ft. 0.01 Sq. ft. 2.42 Sq. ft. 1.32 Sq. ft. 2.31 Sq. ft. Program : Home Enerr,y Savings -_, -Insulation -Floor -Self Install -Electric FAF Heating System -ID Insulation -Floor -Self Install -Electric Heat Pump Heating System -ID Insulation -Floor -Self Install -Electric Zonal Heating System -ID lnsulation:Wall Insulation Insulation -Wall -Electric FAF Heating System -ID Insulation -Wall -Electric Heat Pump Heating System -ID Insulation -Wall -Electric Zonal Heating System -ID Insulation -Wall -Gas Heat with CAC -ID Windows:Windows Tier 1 Window Tier 1 -U-0.30 -Electric FAF Heating System -ID Window Tier 1 -U-0.30 -Electric Heat Pump Heating System -ID Window Tier 1 -U-0.30 -Electric Zonal Heating System -ID Windows:Windows Tier 2 Window Tier 2 -U-0.22 -Electric FAF Heating System -ID Window Tier 2 -U-0.22 -Electric Heat Pump Heating System -ID Window Tier 2 -U-0.22 -Electric Zonal Heating System -ID Measure Category : Electronlcs Advanced Power Strips:Advanced Power Strips -IR Sensing dvanced Power Strip -IR Sensing -Direct Install -ID dvanced Power Strip -IR Sensing -Owner Install -ID Advanced Power Strips:Advanced Power Strips -Load Sensing dvanced Power Strip -Load Sensing -Direct Install -ID dvanced Power Strip -Load Sensing -Owner Install -ID Advanced Power Strips:Advanced Power Strips -Occupancy dvanced Power Strip -Occupancy Sensing -Direct Install -ID dvanced Power Strip -Occupancy Sensing -Owner Install -ID Measure Category : Energy Kita Lighting:CFL Kit Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date ·- nstall floor insulation -Self-install 04/14/2014 nstall floor insulation -Self-install 04/14/2014 nstall floor insulation -Self-install 04/14/2014 Residential nstall wall insulation -Contractor 04/14/2014 nstall wall insulation -Contractor 04/14/2014 Install wall insulation -Contractor 04/14/2014 Install wall insulation -Contractor 04/14/2014 Residential nstall low U-factor window -Tier 1 08/20/2012 nstall low U-factor window -Tier 1 08/20/2012 nstall low U-factor window -Tier 1 08/20/2012 Residential nstall low U-factor window -Tier 2 08/20/2012 nstall low U-factor window -Tier 2 08/20/2012 nstall low U-factor window -Tier 2 08/20/2012 Residential dvanced Power Strip 04/14/2014 dvanced Power Strip 04/14/2014 Residential dvanced Power Strip 04/14/2014 dvanced Power Strip 04/14/2014 Residential dvanced Power Strip 04/14/2014 dvanced Power Strip 04/14/2014 Residential Report Date : 04/27/2015 Energy Savings Calculation method ··~-·-,~ RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed Page 2 of 55 Rocky Mountain Power Attachment 2 Page 59 of 112 Case No. PAC-E.1&-14 Gross incremental annual Savings unit electric savings (kWh/yr) 2.42 Sq. ft 1.32 Sq, ft 2.31 Sq. ft. 2.93 Sq. ft. 2.12 Sq. ft. 2.55 Sq. ft. 0.01 Sq. ft. 2.5 Sq. ft. 1.81 Sq. ft. 2.18 Sq. ft. 6.2 Sq. ft. 4.54 Sq. ft. 5.39 Sq. ft. 300 Measure 300 Measure 40 Measure 30 Measure 70 Measure 70 Measure Program : Home Energy Savings nergy Savings Kit -CFL -ID Lighting:LED Kit nergy Savings Kit -LED -ID Lighting and Plumbing:Basic Kit [Energy Savings Kit -Basic -1 Bathroom -ID nergy Savings Kit -Basic -2 Bathrooms -ID Lighting and Plumbing:Best Kit nergy Savings Kit -Best -1 Bathroom -ID :Energy Savings Kit -Best -2 Bathrooms -ID Lighting and Plumbing:Better Kit nergy Savings Kit -Better -1 Bathroom -ID [Energy Savings Kit -Better -2 Bathrooms -ID Measul'II Category : HVAC Cooling:Central Air Conditioner entral Air Conditioner -ID Cooling:Evaporative Cooler vaporative Cooler -2,000 -3.499 CFM -ID vaporative Cooler -Min 3,500 CFM -ID Cooling:Residential Room Air Conditioner oom Air Conditioner -ENERGY STAR -ID Ducting:Duct Sealing and/or Insulation uct Sealing & Insulation -Electric FAF with CAC -ID uct Sealing & Insulation -Electric FAF without CAC -ID uct Sealing & Insulation -Electric Heat Pump Heating System -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 nergy savings kit -4-13 W CFLs Residential [Energy savings kit -4-13 W LEDs Residential [Energy savings kit -4-13W CFLs, 1.5 GPM kitchen aerator, 0.5[ PM bathroom aerator, 1.5 GPM showerhead nergy savings kit-4-13W CFLs, 1.5 GPM kitchen aerator, 2- .5 GPM bathroom aerators, 2-1.5 GPM showerheads Residential nergy savings kit -4-10W LEDs, 1.5 GPM kitchen aerator, .5 GPM bathroom aerator, 1.5 GPM handheld showerhead [Energy savings kit -4-1 OW LEDs, 1.5 GPM kitchen aerator, 2- .5 GPM bathroom aerators, 2-1 .5 GPM handheld howerheads Residential nergy savings kit -4-13W CFLs, 1.5 GPM kitchen aerator, 0.5[ PM bathroom aerator. 1.5 GPM handheld showerhead nergy savings kit -4-13W CFLs. 1.5 GPM kitchen aerator. 2- .5 GPM bathroom aerators, 2-1.5 GPM handheld howerheads Residential nergy efficient central air conditioning Residential ortable evaporative cooling system ermamently installed evaporative cooling system Residential nergy efficient room air conditioner Residential eal and insulate existing duct work eal and insulate existing duct work eal and insulate existing duct work Effective Date 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 08/20/2012 08/20/2012 08/20/2012 Report Date : 04/27/2015 I I I Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RTF Deemed RTF Deemed RTF Deemed Page 3 of 55 I I Rocky Mountain Po1Ner Attachment 2 Page 60 of 112 Case No. PAC-E.16--14 Gross incremental annual electric savings (kWh/yr) Savings unit 63.68 I Measure 92.12 I Measure 412.04 Measure 734.63 Measure 440.48 Measure 763.07 Measure 412.04 Measure 734.63 Measure 89.25 Measure 210 Measure 368 Measure 39 I Measure 3,351 Measure 3,251 Measure 4,269 Measure Program : Home Energy Savings Duct Sealing & Insulation -Gas FAF with CAC -ID Duct Sealing Only -Pre-Insulated Ducts -Electric FAF with CAC -ID Duct Sealing Only - Pre-Insulated Ducts -Electric FAF without CAC -ID Duct Sealing Only -Pre-Insulated Ducts -Electric Heat Pump Heating svstem -ID Ducting:Duct Sealing and/or Insulation Manufactured Home -Duct Sealing -Direct Install -Test Only -ID Manufactured Home -Duct Sealing -Direct Install -Test, Crossover Reolacement Seal and Insulate -ID Manufactured Home -Duct Sealing -Direct Install -Test. Seal and nsulate -ID Heat Pump:Heat Pump -Air Source Heat Pump Conversion -Tier 1 -Electric FAF with CAC -ID Heat Pump Conversion -Tier 1 -Electric FAF without CAC -ID Heat Pump Conversion -Tier 2 -Electric FAF with CAC -ID Heat Pump Conversion -Tier 2 -Electric FAF without CAC -ID Heat Pump Upgrade -Tier 1 -with Best practice install & sizing -ID Heat Pump Upgrade -Tier 2 -with Best practice install & sizing -ID Heat Pump:Heat Pump -Ductless uctless Heat Pump -ID Heat Pump:Heat Pump -Ground Source K;SHP Conversion from FAF without CAC -ID '3SHP Upgrade from ASHP -ID Heat Pump:Heat Pump -Quality Installation eat Pump Best Practices Installation and Proper Sizing -ID Heat Pump:Heat Pump -Tune-Up ~eat Pump Tune-Up -ID Ventilation:Furnace Fan Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 ~. -.. ,-.. !Seal and insulate existing duct work !Seal existing duct work -Pre-insulated ducts ISeal existing duct work -Pre-insulated ducts !Seal existing duct work -Pre-insulated ducts Residential Manufactured Home rrest existing duct work fT est, Seal and insulate existing duct work. Crossover eolacement Test, Seal and insulate existing duct work Residential Convert electric forced air furnace to air source heat pump vonvert electric forced air furnace to air source heat pump IConvert electric forced air furnace to air source heat pump !Convert electric forced air furnace to air source heat pump Combine heat pump upgrade with best practices sizing and nstallation Combine heat pump upgrade with best practices sizing and nstallation Residential nstall ductless heat pump Residential Convert electric forced air furnace to ground source heat pump Replace air source heat pump with ground source heat pump Residential nstall new heat pump with best practices installation and roper sizin Residential [une-up existing heat pump equipment Residential Effective Date 08/20/2012 08/20/2012 08/20/2012 08/20/2012 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 08/20/2012 08/20/2012 08/20/2012 04/14/2014 04/14/2014 04/14/2014 08/20/2012 Report Date : 04/27/2015 Energy Savings Calculation method RTF Deemed RTF Deemed RTF Deemed RTF Deemed null RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RMP Deemed RMP Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed Page 4 of 55 Rocky Mountain Power Attachment 2 Page 61 of 1 12 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 100 Measure 2,177 Measure 2,138 Measure 2,059 Measure 0 Measure 3,267 Measure 3,267 Measure 5,182 Measure 4,672 Measure 5,676 Measure 5,166 Measure 2,998 Measure 3,188 Installation 3,500 Measure 12,525 Measure 4,702 Measure 2,694 Measure 639 Measure Program : Home Energy Savings 5% Gas Furnace with ECM Blower -ID ~easure Category : Lighting General Service Fixtures:CFL FL Fixture -ENERGY STAR -ID General Service Fixtures:LED ED Fixture -ENERGY STAR -ID General Service Lamps:CFL r FL General Purpose -A-Lamp: 11 watts -Direct Install -ID ~FL General Purpose -A-Lamp: 11 watts -Mail By Request -ID CFL General Purpose -A-Lamp: 11 watts -Retail -ID r FL General Purpose -A-Lamp: 13 watts -Direct Install -ID ~FL General Purpose -A-Lamp: 13 watts -Mail By Request -ID ~FL General Purpose -A-Lamp: 13 watts -Retail -ID CFL General Purpose -A-Lamp: 14 watts -Direct Install -ID rFL General Purpose -A-Lamp: 14 watts -Mail By Request -ID ~FL General Purpose - A-Lamp: 14 watts -Retail -ID CFL General Purpose -A-Lamp: 15 watts -Direct Install -ID CFL General Purpose - A-Lamp: 15 watts -Mail By Request -ID ~FL General Purpose - A-Lamp: 15 watts -Retail -ID CFL General Purpose -A-Lamp: 19 watts -Direct Install -ID ~FL General Purpose -A-Lamp: 19 watts -Mail By Request -ID tFL General Purpose -A-Lamp: 19 watts -Retail -ID CFL General Purpose -A-Lamp: 20 watts -Direct Install -ID CFL General Purpose - A-Lamp: 20 watts -Mail By Request -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date !Install 95%+ AFUE gas furnace with ECM blower 08/20/2012 Residential !ENERGY STAR general service CFL fixture 04/14/2014 Residential ENERGY STAR general service LED fixture 04/14/2014 Residential Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 :::nergy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 !Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 [Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 11:nergy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General 04/14/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 5 of 55 Rocky Mountain Power Attachment 2 Page 62 of 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) Savings unit 528 Measure 43.66 Measure 40.94 Measure 12.82 Measure 9.55 Measure 9.55 Measure 21.37 Measure 15.92 Measure 15.92 Measure 20.66 Measure 15.39 Measure 15.39 Measure 19.94 Measure 14.86 Measure 14.86 Measure 17.1 Measure 12.73 Measure 12.73 Measure 23.51 Measure 17.51 Measure f rogram : Home Energy Savings K;FL General Purpose -A-Lamp: 20 watts -Retail -ID K:FL General Purpose -A-Lamp: 9 watts -Direct Install -ID t FL General Purpose -A-Lamp: 9 watts -Mail By Request -ID CFL General Purpose -A-Lamp: 9 watts -Retail -ID CFL General Purpose -Spiral: 10 watts -Direct Install -ID CFL General Purpose -Spiral: 10 watts -Mail By Request -ID CFL General Purpose -Spiral: 10 watts -Retail -ID CFL General Purpose -Spiral: 11 watts -Direct Install -ID CFL General Purpose -Spiral: 11 watts -Mail By Request -ID CFL General Purpose -Spiral: 11 watts -Retail -ID CFL General Purpose -Spiral: 12 watts -Direct Install -ID CFL General Purpose -Spiral: 12 watts -Mail By Request -ID CFL General Purpose -Spiral: 12 watts -Retail -ID CFL General Purpose -Spiral: 13 watts -Direct Install -ID CFL General Purpose -Spiral: 13 watts -Mail By Request -ID CFL General Purpose -Spiral: 13 watts -Retail -ID CFL General Purpose -Spiral: 14 watts -Direct Install -ID CFL General Purpose -Spiral: 14 watts -Mail By Request -ID CFL General Purpose -Spiral: 14 watts -Retail -ID CFL General Purpose -Spiral: 15 watts -Direct Install -ID CFL General Purpose -Spiral: 15 watts -Mail By Request -ID CFL General Purpose -Spiral: 15 watts -Retail -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date -- Purpose t:nergy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 !energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General 04/14/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 6 of 55 Rocky Mountain Po'Ner Attachment 2 Page 63 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 17.51 Measure 14.25 Measure 10.61 Measure 10.61 Measure 13.53 Measure 10.08 Measure 10.08 Measure 12.82 Measure 9.55 Measure 9.55 Measure 12.11 Measure 9.02 Measure 9.02 Measure 21.37 Measure 15.92 Measure 15.92 Measure 20.66 Measure 15.39 Measure 15.39 Measure 27.07 Measure 20.16 Measure 20.16 Measure Program : Home Enerr,y Savings - ~FL General Purpose -Spiral: 18 watts -Direct Install -ID ~FL General Purpose -Spiral: 18 watts -Mail By Request -ID CFL General Purpose -Spiral: 18 watts -Retail -ID ~FL General Purpose -Spiral: 19 watts -Direct Install -ID ~FL General Purpose -Spiral: 19 watts -Mail By Request -ID K:FL General Purpose -Spiral: 19 watts -Retail -ID ~FL General Purpose -Spiral: 20 watts -Direct Install -ID ~FL General Purpose -Spiral: 20 watts -Mail By Request -ID K:FL General Purpose -Spiral: 20 watts -Retail -ID t FL General Purpose -Spiral: 21 watts -Retail -ID CFL General Purpose -Spiral: 22 watts -Retail -ID CFL General Purpose -Spiral: 23 watts -Direct Install -ID CFL General Purpose -Spiral: 23 watts -Mail By Request -ID CFL General Purpose -Spiral: 23 watts -Retail -ID CFL General Purpose -Spiral: 24 watts -Retail -ID tFL General Purpose -Spiral: 26 watts -Direct Install -10 t FL General Purpose -Spiral: 26 watts -Mail By Request -ID CFL General Purpose -Spiral: 26 watts -Retail -ID CFL General Purpose -Spiral: 27 watts -Direct Install -ID t FL General Purpose -Spiral: 27 watts -Mail By Request -ID CFL General Purpose -Spiral: 27 watts -Retail -ID CFL General Purpose -Spiral: 28 watts - Direct Install -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date - Purpose Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 :::nergy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 !Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 [Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 [Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General 04/14/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 7 of 55 Rocky Mountain Power Attachment 2 Page 64of112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 24.93 Measure 18.57 Measure 18.57 Measure 24.22 Measure 18.04 Measure 18.04 Measure 23.51 Measure 17.51 Measure 17.51 Measure 27.06 Measure 26.53 Measure 34.9 Measure 26 Measure 26 Measure 25.47 Measure 32.77 Measure 24.41 Measure 24.41 Measure 32.05 Measure 23.88 Measure 23.88 Measure 31.34 Measure Program : Home Energy Savings ~FL General Purpose -Spiral: 28 watts -Mail By Request -ID K;FL General Purpose -Spiral: 28 watts -Retail -ID CFL General Purpose -Spiral: 29 watts -Direct Install -ID CFL General Purpose -Spiral: 29 watts -Mail By Request -ID CFL General Purpose -Spiral: 29 watts -Retail -ID CFL General Purpose -Spiral: 3 watts -Direct Install -ID CFL General Purpose -Spiral: 3 watts -Mail By Request -ID CFL General Purpose -Spiral: 3 watts -Retail -ID CFL General Purpose -Spiral: 30 watts -Direct Install -ID CFL General Purpose -Spiral: 30 watts -Mail By Request -ID CFL General Purpose -Spiral: 30 watts -Retail -ID CFL General Purpose -Spiral: 31 watts -Direct Install -ID CFL General Purpose -Spiral: 31 watts -Mail By Request -ID CFL General Purpose -Spiral: 31 watts -Retail -ID CFL General Purpose -Spiral: 32 watts -Direct Install -ID CFL General Purpose -Spiral: 32 watts -Mail By Request -ID CFL General Purpose -Spiral: 32 watts -Retail -ID CFL General Purpose -Spiral: 4 watts -Direct Install -ID CFL General Purpose -Spiral: 4 watts -Mail By Request -ID CFL General Purpose -Spiral: 4 watts -Retail -ID CFL General Purpose -Spiral: 5 watts -Direct Install -ID CFL General Purpose -Spiral: 5 watts -Mail By Request -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Purpose Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General 04/14/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 8 of 55 Rocky Mountain Po-...ier Attachment 2 Page 65 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings {kWh/yr) 23.35 Measure 23.35 Measure 30.63 Measure 22.82 Measure 22.82 Measure 8.55 Measure 6.37 Measure 6.37 Measure 29.92 Measure 22.28 Measure 22.28 Measure 29.2 Measure 21.75 Measure 21.75 Measure 28.49 Measure 21.22 Measure 21.22 Measure 14.96 Measure 11.14 Measure 11.14 Measure 17.81 Measure 13.26 Measure Program : Home Energy Savings CFL General Purpose -Spiral: 5 watts -Retail -ID CFL General Purpose -Spiral: 6 watts -Direct Install -ID C:FL General Purpose -Spiral: 6 watts -Mail By Request -ID (:FL General Purpose -Spiral: 6 watts -Retail -ID CFL General Purpose -Spiral: 7 watts -Direct Install -ID C:FL General Purpose -Spiral: 7 watts -Mail By Request -ID CFL General Purpose -Spiral: 7 watts -Retail -ID CFL General Purpose -Spiral: 8 watts -Direct Install -ID CFL General Purpose -Spiral: 8 watts -Mail By Request -ID CFL General Purpose -Spiral: 8 watts -Retail -ID CFL General Purpose -Spiral: 9 watts -Direct Install -ID CFL General Purpose -Spiral: 9 watts -Mail By Request -ID CFL General Purpose -Spiral: 9 watts -Retail -ID General Service Lamps:LED ED General Purpose: 10 watts -Direct Install -ID ED General Purpose: 10 watts -Mail By Request -ID ED General Purpose: 10 watts -Retail -ID ED General Purpose: 11 watts -Direct Install -ID ED General Purpose: 11 watts -Mail By Request -ID ED General Purpose: 11 watts -Retail -ID ED General Purpose: 12 watts -Direct Install -ID ED General Purpose: 12 watts -Mail By Request -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Purpose ~nergy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Energy efficient Compact Fluorescent Lamps-General Purpose 04/14/2014 Residential Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 9 of 55 Rocky Mountain Power Attachment 2 Page 66 of 112 Case No. PAC-E·1S..14 Gross incremental annual Savings unit electric savings (kWh/yr) 13.26 Measure 16.38 Measure 12.2 Measure 12.2 Measure 15.67 Measure 11 .67 Measure 11 .67 Measure 14.96 Measure 11.14 Measure 11.14 Measure 14.25 Measure 10.61 Measure 10.61 Measure 23.03 Measure 23.03 Measure 23.99 Measure 22.33 Measure 22.33 Measure 23.26 Measure 21 .63 Measure 21 .63 Measure Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Program : Home Energy Savings ~ED General Purpose: 12 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 '--ED General Purpose: 13 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 13 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 13 watts -Retail -ID 11::nergy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 14 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 14 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 14 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 15 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 15 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 15 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 LED General Purpose: 16 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 16 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 16 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 17 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 2 watts -Semi-omnidirectional -Direct Install -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 2 watts -Semi-omnidirectional -Mail By Request -Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 D ED General Purpose: 2 watts -Semi-omnidirectional -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 23 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 23 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 23 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 6 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 7 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 Report Date: 04/27/2015 Energy Savings Calculation method .. RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 10 of 55 Rocky Mountain Po'Ner Attachment 2 Page 67 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 22.53 Measure 20.93 Measure 20.93 Measure 21.81 Measure 20.24 Measure 20.24 Measure 21.08 Measure 19.54 Measure 19.54 Measure 20.35 Measure 25.82 Measure 25.82 Measure 26.89 Measure 39.98 Measure 16.05 Measure 16.05 Measure 16.72 Measure 34.19 Measure 34.19 Measure 35.62 Measure 16.72 Measure 15.35 Measure Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Program : Home Energy Savings -· ,-ED General Purpose: 7 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ,-ED General Purpose: 7 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ,_ED General Purpose: 8 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ,-ED General Purpose: 8 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ,-ED General Purpose: 8 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ,_ED General Purpose: 8 watts -Semi-omnidirectional -Direct Install -ID !Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ,_ED General Purpose: 8 watts -Semi-omnidirectional -Mail By Request -!Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 D ED General Purpose: 8 watts -Semi-omnidirectional -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 9 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 9 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 9 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 9 watts -Semi-omnidirectional -Direct Install -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ED General Purpose: 9 watts -Semi-omnidirectional -Mail By Request -Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 ID ED General Purpose: 9 watts -Semi-omnidirectional -Retail -ID Energy efficient Light Emitting Diode Lamps-General Purpose 04/14/2014 Specialty Lamps:CFL Residential CFL Specialty -3-Way: 10,20,28 watts -Direct Install -ID Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 CFL Specialty -3-Way: 10,20,28 watts -Mail By Request -ID [Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 CFL Specialty -3-Way: 10,20,28 watts -Retail -ID Energy efficient Compact Fluorescent Lamps-Specialty 01 /01/2014 CFL Specialty-3-Way: 12,19,28 watts -Direct Install -ID !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 CFL Specialty -3-Way: 12, 19,28 watts -Mail By Request -ID Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 CFL Specialty -3-Way: 12, 19,28 watts -Retail -ID Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 CFL Specialty -3-Way: 12,20,26 watts -Direct Install -ID Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 CFL Specialty -3-Way: 12,20,26 watts -Mail By Request -ID Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 CFL Specialty -3-Way: 12,20,26 watts -Retail - ID :nergy efficient Compact Fluorescent Lamps-Specialty 01 /01/2014 ~FL Specialty -3-Way: 12,20,29 watts -Direct Install -ID Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 11 of 55 Rocky Mountain Power Attachment 2 Page 68 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 15.35 Measure 15.99 Measure 14.65 Measure 14.65 Measure 15.26 Measure 14.65 Measure 14.65 Measure 15.26 Measure 13.96 Measure 13.96 Measure 14.54 Measure 13.96 Measure 13.96 Measure 14.54 Measure 56.98 Measure 42.45 Measure 42.45 Measure 57.7 Measure 42.98 Measure 42.98 Measure 56.98 Measure 42.45 Measure 42.45 Measure 56.98 Measure Program : Home Energy Savings CFL Specialty -3-Way: 12,20,29 watts -Mail By Request -ID CFL Specialty-3-Way: 12,20,29 watts -Retail -ID CFL Specialty -3-Way: 12,21 ,32 watts -Direct Install -ID K;FL Specialty -3-Way: 12,21,32 watts -Mail By Request -ID K;FL Specialty -3-Way: 12,21 ,32 watts -Retail -ID K;FL Specialty -3-Way: 12,22,33 watts -Direct Install -ID K;FL Specialty -3-Way: 12,22,33 watts -Mail By Request -ID ~FL Specialty -3-Way: 12,22,33 watts -Retail -ID ~FL Specialty -3-Way: 12,23,29 watts -Direct Install -ID CFL Specialty -3-Way: 12,23,29 watts -Mail By Request -ID CFL Specialty -3-Way: 12,23,29 watts -Retail -ID CFL Specialty -3-Way: 13,20,25 watts -Direct Install -ID CFL Specialty -3-Way: 13,20,25 watts -Mail By Request -ID CFL Specialty-3-Way: 13,20,25 watts -Retail -ID K;FL Specialty -3-Way: 14, 19,32 watts -Direct Install -ID K;FL Specialty -3-Way: 14, 19,32 watts -Mail By Request -ID K;FL Specialty -3-Way: 14, 19,32 watts -Retail -ID ~FL Specialty -3-Way: 15,26,40 watts -Direct Install -ID ~FL Specialty -3-Way: 15,26,40 watts -Mail By Request -ID CFL Specialty-3-Way: 15,26,40 watts -Retail -ID CFL Specialty -3-Way: 16,25,32 watts -Direct Install -ID CFL Specialty -3-Way: 16,25,32 watts -Mail By Request -ID K;FL Specialty -3-Way: 16,25,32 watts -Retail -ID K;FL Specialty -Candelabra: 13 watts -Direct Install -ID K;FL Specialty-Candelabra: 13 watts -Mail By Request -ID ~FL Specialty-Candelabra: 13 watts -Retail -ID CFL Specialty-Candelabra: 14 watts -Direct Install -ID CFL Specialty-Candelabra: 14 watts -Mail By Request -ID CFL Specialty-Candelabra: 14 watts -Retail -ID K;FL Specialty -Candelabra: 3 watts -Direct Install -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date .. Energy efficient Compact Fluorescent Lamps-Specialty 04/1 4/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01 /01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01 /01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01 /01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 12 of 55 Rocky Mountain Power Attachment 2 Page 69 of 112 Case No. PAC-E-16.14 Gross incremental annual Savings unit electric savings {kWh/yr) - 42.45 Measure 42.45 Measure 56.27 Measure 41.92 Measure 41.92 Measure 55.56 Measure 41 .39 Measure 41.39 Measure 54.85 Measure 40.86 Measure 40.86 Measure 56.98 Measure 42.45 Measure 42.45 Measure 57.7 Measure 42.98 Measure 42.98 Measure 52.71 Measure 39.26 Measure 39.26 Measure 53.42 Measure 39.79 Measure 39.79 Measure 21 .37 Measure 15.92 Measure 15.92 Measure 20.66 Measure 15.39 Measure 15.39 Measure 26.36 Measure Program : Home Energy Savings CFL Specialty -Candelabra: 3 watts -Mail By Request -ID CFL Specialty -Candelabra: 3 watts -Retail -ID ~FL Specialty -Candelabra: 5 watts -Direct Install -ID ~FL Specialty -Candelabra: 5 watts -Mail By Request -ID ~FL Specialty -Candelabra: 5 watts -Retail -ID ~FL Specialty -Candelabra: 7 watts -Direct Install -ID t FL Specialty -Candelabra: 7 watts -Mail By Request -ID K;FL Specialty -Candelabra: 7 watts -Retail -ID t FL Specialty -Candelabra: 9 watts -Direct Install -ID CFL Specialty -Candelabra: 9 watts -Mail By Request -ID K::FL Specialty -Candelabra: 9 watts -Retail -ID CFL Specialty -Daylight: 10 watts -Direct Install -ID CFL Specialty -Daylight: 10 watts -Mail By Request -ID CFL Specialty -Daylight: 10 watts -Retail -ID CFL Specialty -Daylight: 13 watts -Direct Install -ID ~FL Specialty -Daylight: 13 watts -Mail By Request -ID ~FL Specialty -Daylight: 13 watts -Retail -ID K:;FL Specialty -Daylight: 14 watts -Direct Install -ID K:;FL Specialty -Daylight: 14 watts -Mail By Request -ID K:;FL Specialty -Daylight: 14 watts -Retail -ID K:;FL Specialty -Daylight: 15 watts -Direct Install -ID K::FL Specialty -Daylight: 15 watts -Mail By Request -ID K:;FL Specialty -Daylight: 15 watts -Retail -ID K::FL Specialty -Daylight: 18 watts -Direct Install -ID CFL Specialty -Daylight: 18 watts -Mail By Request -ID ~FL Specialty -Daylight: 18 watts -Retail -ID ~FL Specialty -Daylight: 19 watts -Direct Install -ID ~FL Specialty -Daylight: 19 watts -Mail By Request -ID ~FL Specialty -Daylight: 19 watts -Retail -ID ~FL Specialty -Daylight: 20 watts -Direct Install -ID . Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01 /01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01 /01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01 /01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01 /01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Report Date: 04/27/2015 Energy Savings Calculation method - RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 13 of 55 Rocky Mountain Po'l.let Attachment 2 Page 70 of 112 Case No. PAC~E~16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 19.63 Measure 19.63 Measure 14.25 Measure 10.61 Measure 10.61 Measure 23.51 Measure 17.51 Measure 17.51 Measure 22.08 Measure 16.45 Measure 16.45 Measure 21.37 Measure 15.92 Measure 15.92 Measure 21 .37 Measure 15.92 Measure 15.92 Measure 20.66 Measure 15.39 Measure 15.39 Measure 19.94 Measure 14.86 Measure 14.86 Measure 24.93 Measure 18.57 Measure 18.57 Measure 24.22 Measure 18.04 Measure 18.04 Measure 23.51 Measure Program : Home Energy Savings .. - tFL Specialty -Daylight: 20 watts -Mail By Request -ID CFL Specialty -Daylight: 20 watts -Retail -ID CFL Specialty -Daylight: 23 watts -Direct Install -ID CFL Specialty -Daylight: 23 watts -Mail By Request -ID CFL Specialty -Daylight: 23 watts -Retail -ID CFL Specialty -Daylight: 24 watts -Retail -ID CFL Specialty -Daylight: 26 watts -Direct Install -ID CFL Specialty -Daylight: 26 watts -Mail By Request -ID CFL Specialty -Daylight: 26 watts -Retail -ID CFL Specialty -Daylight: 27 watts -Direct Install -ID CFL Specialty -Daylight: 27 watts -Mail By Request -ID CFL Specialty -Daylight: 27 watts -Retail -ID CFL Specialty -Daylight: 9 watts - Direct Install -ID CFL Specialty -Daylight: 9 watts -Mail By Request -ID CFL Specialty -Daylight: 9 watts -Retail -ID CFL Specialty -Dimmable: 11 watts -Direct Install -ID CFL Specialty -Dimmable: 11 watts -Mail By Request -ID CFL Specialty -Dimmable: 11 watts -Retail -ID CFL Specialty -Dimmable: 14 watts -Direct Install -ID CFL Specialty-Dimmable: 14 watts -Mail By Request -ID t FL Specialty -Dimmable: 14 watts -Retail -ID tFL Specialty -Dimmable: 15 watts -Direct Install -ID CFL Specialty -Dimmable: 15 watts -Mail By Request -ID CFL Specialty -Dimmable: 15 watts -Retail -ID CFL Specialty-Dimmable: 16 watts -Direct Install -ID CFL Specialty-Dimmable: 16 watts -Mail By Request -ID tFL Specialty -Dimmable: 16 watts -Retail -ID tFL Specialty -Dimmable: 20 watts -Direct Install -ID t FL Specialty -Dimmable: 20 watts -Mail By Request -ID CFL Specialty -Dimmable: 20 watts -Retail -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date .. "' Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 l,.nergy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 l,.nergy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 l,.nergy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMPDeemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 14 of 55 Rocky Mountain Power Attachment 2 Page 71 of 112 Case No. PAC-E.16-14 Gross incremental annual Savings unit electric savings (kWh/yr) .. ~ 17.51 Measure 17.51 Measure 34.9 Measure 26 Measure 26 Measure 25.47 Measure 32.77 Measure 24.41 Measure 24.41 Measure 32.05 Measure 23.88 Measure 23.88 Measure 22.08 Measure 16.45 Measure 16.45 Measure 20.66 Measure 15.39 Measure 15.39 Measure 32.77 Measure 24.41 Measure 24.41 Measure 32.05 Measure 23.88 Measure 23.88 Measure 17.1 Measure 12.73 Measure 12.73 Measure 28.49 Measure 21 .22 Measure 21 .22 Measure Program : Home Energy Savings CFL Specialty -Dimmable: 23 watts -Direct Install -ID CFL Specialty -Dimmable: 23 watts -Mail By Request -ID CFL Specialty -Dimmable: 23 watts -Retail -ID CFL Specialty -Dimmable: 24 watts · Direct Install -ID CFL Specialty -Dimmable: 24 watts -Mail By Request -ID CFL Specialty -Dimmable: 24 watts -Retail -ID CFL Specialty· Dimmable: 25 watts · Retail -ID CFL Specialty -Dimmable: 26 watts -Direct Install -ID CFL Specialty -Dimmable: 26 watts -Mail By Request -ID CFL Specialty · Dimmable: 26 watts · Retail -ID (;FL Specialty -Dimmable: 27 watts -Direct Install -ID CFL Specialty -Dimmable: 27 watts -Mail By Request -ID CFL Specialty -Dimmable: 27 watts -Retail -ID CFL Specialty -Globe: 11 watts -Direct Install -ID CFL Specialty -Globe: 11 watts -Mail By Request -ID CFL Specialty -Globe: 11 watts -Retail -ID CFL Specialty -Globe: 12 watts -Direct Install -ID CFL Specialty -Globe: 12 watts -Mail By Request -ID CFL Specialty -Globe: 12 watts -Retail -ID CFL Specialty -Globe: 14 watts -Direct Install -ID CFL Specialty -Globe: 14 watts -Mail By Request -ID CFL Specialty -Globe: 14 watts • Retail • ID CFL Specialty -Globe: 15 watts -Direct Install -ID CFL Specialty -Globe: 15 watts -Mail By Request -ID CFL Specialty -Globe: 15 watts -Retail -ID CFL Specialty -Globe: 25 watts -Direct Install -ID CFL Specialty -Globe: 25 watts -Mail By Request -ID CFL Specialty -Globe: 25 watts -Retail -ID CFL Specialty -Globe: 9 watts -Direct Install -ID CFL Specialty -Globe: 9 watts -Mail By Request -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/201S Effective Date Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 [Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 [Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 [Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 [Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 !Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 [Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 !Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 !Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 [Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Report Date : 04/27/201S .. Energy Savings Calculation method - RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 1S of SS Rocky Mountain Power Attachment 2 Page 72 of 112 Case No. PAC-E.16--14 Gross incremental annual Savings unit electric savings (kWh/yr) ., 54.85 Measure 40.86 Measure 40.86 Measure 54.13 Measure 40.33 Measure 40.33 Measure 39.79 Measure 52.71 Measure 39.26 Measure 39.26 Measure 52 Measure 38.73 Measure 38.73 Measure 20.66 Measure 15.39 Measure 15.39 Measure 19.94 Measure 14.86 Measure 14.86 Measure 20.66 Measure 15.39 Measure 15.39 Measure 19.94 Measure 14.86 Measure 14.86 Measure 19.94 Measure 14.86 Measure 14.86 Measure 22.08 Measure 16.45 Measure -Program : Home Energy Savings K:FL Specialty -Globe: 9 watts -Retail -ID ~FL Specialty -Outdoor: 11 watts -Direct Install -ID CFL Specialty -Outdoor: 11 watts -Mail By Request -ID CFL Specialty -Outdoor: 11 watts -Retail -ID CFL Specialty -Outdoor: 13 watts -Direct Install -ID CFL Specialty -Outdoor: 13 watts -Mail By Request -ID CFL Specialty -Outdoor: 13 watts -Retail -ID CFL Specialty -Outdoor: 14 watts -Direct Install -ID CFL Specialty -Outdoor: 14 watts -Mail By Request -ID CFL Specialty -Outdoor: 14 watts -Retail -ID CFL Specialty -Outdoor: 15 watts -Direct Install -ID CFL Specialty -Outdoor: 15 watts -Mail By Request -ID CFL Specialty -Outdoor: 15 watts -Retail -ID CFL Specialty -Outdoor: 23 watts -Direct Install -ID CFL Specialty -Outdoor: 23 watts -Mail By Request -ID CFL Specialty -Outdoor: 23 watts -Retail -ID CFL Specialty -Outdoor: 26 watts -Direct Install -ID CFL Specialty -Outdoor: 26 watts -Mail By Request -ID CFL Specialty -Outdoor: 26 watts -Retail -ID CFL Specialty -Outdoor: 9 watts -Direct Install -ID CFL Specialty -Outdoor: 9 watts -Mail By Request -ID CFL Specialty -Outdoor: 9 watts -Retail -ID CFL Specialty -Reflector: 11 watts -Direct Install -ID CFL Specialty -Reflector: 11 watts -Mail By Request -ID CFL Specialty -Reflector: 11 watts -Retail -ID CFL Specialty-Reflector: 14 watts -Direct Install -ID CFL Specialty -Reflector: 14 watts -Mail By Request -ID CFL Specialty-Reflector: 14 watts -Retail -ID CFL Specialty -Reflector: 15 watts -Direct Install -ID CFL Specialty -Reflector: 15 watts -Mail By Request -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date ., '• --,. Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01 /2014 l:nergy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Report Date : 04/27/2015 Energy Savings Calculation method . RMP Deemed RMP Deemed RMPDeemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMPDeemed RMPDeemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMPDeemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 16 of 55 Rocky Mountain Pov.,,er Attachment 2 Page 73 of 112 Case No. PAC-E·16-14 Gross incremental annual Savings unit electric savings {kWh/yr) _,.,. 16.45 Measure 20,66 Measure 15,39 Measure 15,39 Measure 19.23 Measure 14,33 Measure 14.33 Measure 32n Measure 24.41 Measure 24.41 Measure 32,05 Measure 23.88 Measure 23,88 Measure 12,11 Measure 9,02 Measure 9.02 Measure 34,9 Measure 26 Measure 26 Measure 22,08 Measure 16.45 Measure 16.45 Measure 13.53 Measure 10.08 Measure 10.08 Measure 36.33 Measure 27.06 Measure 27,06 Measure 35.62 Measure 26,53 Measure Program : Home Energy Savings -.. " ........ ·~ ... · CFL Specialty-Reflector: 15 watts -Retail -ID t FL Specialty -Reflector: 16 watts -Direct Install -ID t FL Specialty-Reflector: 16 watts -Mail By Request -ID CFL Specialty -Reflector: 16 watts -Retail -ID t FL Specialty -Reflector: 18 watts -Direct Install -ID t FL Specialty -Reflector: 18 watts -Mail By Request -ID t FL Specialty -Reflector: 18 watts -Retail -ID tFL Specialty -Reflector: 19 watts -Direct Install -ID CFL Specialty -Reflector: 19 watts -Mail By Request -ID CFL Specialty-Reflector: 19 watts -Retail -ID K;FL Specialty -Reflector: 20 watts -Direct Install -ID CFL Specialty -Reflector: 20 watts -Mail By Request -ID CFL Specialty -Reflector: 20 watts -Retail -ID CFL Specialty -Reflector: 23 watts -Direct Install -ID CFL Specialty -Reflector: 23 watts -Mail By Request -ID CFL Specialty -Reflector: 23 watts -Retail - ID CFL Specialty -Reflector: 26 watts -Direct Install -ID CFL Specialty -Reflector: 26 watts -Mail By Request -ID CFL Specialty -Reflector: 26 watts -Retail -ID CFL Specialty -Reflector: 9 watts -Direct Install -ID CFL Specialty -Reflector: 9 watts -Mail By Request -ID CFL Specialty -Reflector: 9 watts -Retail -ID Specialty Lamps:LED ED Downlight: 10 watts -Direct Install -ID ED Downlight: 10 watts -Mail By Request - ID ED Downlight: 10 watts -Retail -ID ED Downlight: 11 watts -Direct Install -ID ED Downlight: 11 watts -Mail By Request -ID ED Downlight: 11 watts -Retail -ID ED Downlight: 12 watts -Direct Install -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date -·--·- Energy efficient Compact Fluorescent Lamps-Specialty 01 /01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 :nergy efficient Compact Fluorescent Lamps-Specialty 01 /01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 !Energy efficient Compact Fluorescent Lamps-Specialty 01 /01/2014 !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01 /01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 [Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01/01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01 /01/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 [Energy efficient Compact Fluorescent Lamps-Specialty 01 /01/2014 !Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 04/14/2014 Energy efficient Compact Fluorescent Lamps-Specialty 01 /01/2014 Residential nergy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 :Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 :Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 :Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 :Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 :Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Report Date: 04/27/2015 Energy Savings Calculation method - RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 17 of 55 Rocky Mountain Power Attachment 2 Page 74 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 26.53 Measure 34.9 Measure 26 Measure 26 Measure 40.6 Measure 30.24 Measure 30.24 Measure 39.89 Measure 29.71 Measure 29.71 Measure 39.18 Measure 29.18 Measure 29.18 Measure 47.72 Measure 35.55 Measure 35.55 Measure 45.59 Measure 33.96 Measure 33.96 Measure 14.96 Measure 11.14 Measure 11 .14 Measure 38.38 Measure 38.38 Measure 39.98 Measure 23.72 Measure 23.72 Measure 24.71 Measure 36.98 Measure Program : Home Energy Savings " ... -···,.- ED Downlight: 12 watts -Mail By Request -ID ED Downlight: 12 watts -Retail -ID ,_ED Downlight: 13 watts -Direct Install -ID ,_ED Downlight: 13 watts -Mail By Request -ID ,_ED Downlight: 13 watts -Retail -ID ,-ED Downlight: 14 watts -Direct Install -ID ,-ED Downlight: 14 watts -Mail By Request -ID ,-ED Downlight: 14 watts -Retail -ID ,-ED Downlight: 15 watts -Direct Install -ID ,-ED Downlight: 15 watts -Mail By Request -ID ,_ED Downlight: 15 watts -Retail -ID ,_ED Downlight: 16 watts -Direct Install -ID ,_ED Downlight: 16 watts -Mail By Request -ID ,_ED Downlight: 16 watts -Retail -ID ,-ED Downlight: 17 watts -Direct Install -ID ,-ED Downlight: 17 watts -Mail By Request -ID ,~ED Downlight: 17 watts -Retail -ID ,..ED Downlight: 18 watts -Direct Install -ID ,-ED Downlight: 18 watts -Mail By Request -ID ,..ED Downlight: 18 watts -Retail -ID ED Downlight: 19 watts -Direct Install -ID ED Downlight: 19 watts -Mail By Request -ID ED Downlight: 19 watts -Retail -ID ED Downlight: 20 watts -Direct Install -ID ED Downlight: 20 watts -Mail By Request -ID ED Downlight: 20 watts -Retail -ID ED Downlight: 23 watts -Direct Install -ID ED Downlight: 23 watts -Mail By Request -ID ED Downlight: 23 watts -Retail -ID ED Downlight: 5 watts -Direct Install -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date ". (nergy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 (nergy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Report Date: 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 18 of 55 Rocky Mountain Po<Ner Attachment 2 Page 75 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 36.98 Measure 38.52 Measure 36.28 Measure 36.28 Measure 37.8 Measure 35.59 Measure 35.59 Measure 37.07 Measure 34.89 Measure 34.89 Measure 36.34 Measure 41.17 Measure 41.17 Measure 42.88 Measure 40.47 Measure 40.47 Measure 42.16 Measure 39.77 Measure 39.77 Measure 41.43 Measure 39.07 Measure 39.07 Measure 40.7 Measure 38.38 Measure 38.38 Measure 39.98 Measure 46.75 Measure 46.75 Measure 48.7 Measure 48.84 Measure Program : Home Energy Savings ED Downlight: 5 watts -Mail By Request -ID ED Downlight: 5 watts -Retail -ID ED Downlight: 6 watts -Direct Install -ID ED Downlight: 6 watts -Mail By Request -ID ED Downlight: 6 watts -Retail -ID ED Downlight: 7 watts -Direct Install -ID ED Downlight: 7 watts -Mail By Request -ID ED Downlight: 7 watts -Retail -ID ED Downlight: 8 watts -Direct Install -ID ED Downlight: 8 watts -Mail By Request -ID ED Downlight: 8 watts -Retail -ID ED Downlight: 9 watts -Direct Install -ID ED Downlight: 9 watts -Mail By Request -ID ED Downlight: 9 watts -Retail -ID ED Specialty -Candelabra: 2 watts -Direct Install -ID ED Specialty -Candelabra: 2 watts -Mail By Request -ID j..ED Specialty -Candelabra: 2 watts -Retail -ID l'-ED Specialty -Candelabra: 4 watts -Direct Install -ID l.ED Specialty -Candelabra: 4 watts -Mail By Request -ID 1.-ED Specialty -Candelabra: 4 watts -Retail -ID ._ED Specialty -Candelabra: 5 watts -Direct Install -ID ,..ED Specialty -Candelabra: 5 watts -Mail By Request -ID ,..ED Specialty -Candelabra: 5 watts -Retail -ID ._ED Specialty -Globe: 10 watts -Retail -ID ,..ED Specialty -Globe: 2 watts -Direct Install -ID ,..ED Specialty -Globe: 2 watts -Mail By Request -ID ,-ED Specialty -Globe: 2 watts -Retail -ID ,..ED Specialty -Globe: 4 watts -Direct Install -ID ,-ED Specialty -Globe: 4 watts -Mail By Request -ID ,-ED Specialty -Globe: 4 watts -Retail -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date - )energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Downlight 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/1 4/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMPDeemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 19 of 55 Rocky Mountain Pov.<er Attachment 2 Page 76 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 48.84 Measure 50.88 Measure 27.21 Measure 27.21 Measure 28.35 Measure 16.05 Measure 16.05 Measure 16.72 Measure 25.82 Measure 25.82 Measure 26.89 Measure 39.07 Measure 39.07 Measure 40.7 Measure 16.05 Measure 16.05 Measure 16.72 Measure 14.65 Measure 14.65 Measure 15.26 Measure 13.96 Measure 13.96 Measure 14.54 Measure 21.81 Measure 16.05 Measure 16.05 Measure 16.72 Measure 14.65 Measure 14.65 Measure 15.26 Measure Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Program : Home Energy Savings ..... ,._ --- ED Specialty -Globe: 5 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 ED Specialty -Globe: 6 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 ED Specialty -Globe: 8 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 -ED Specialty -Globe: 8 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 ,-ED Specialty -Globe: 8 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 ,-ED Specialty -Reflector: 10 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 ,_ED Specialty -Reflector: 10 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 ,-ED Specialty -Reflector: 10 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 ,_ED Specialty -Reflector: 4 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 _ED Specialty -Reflector: 4 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 _ED Specialty -Reflector: 4 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 _ED Specialty -Reflector: 5 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 -ED Specialty -Reflector: 5 watts -Mail By Request -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 -ED Specialty -Reflector: 5 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 ,_ED Specialty -Reflector: 6 watts -Direct Install -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 ,_ED Specialty -Reflector: 6 watts -Mail By Request -ID :::nergy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 ,_ED Specialty -Reflector: 6 watts -Retail -ID Energy efficient Light Emitting Diode Lamps-Specialty 04/14/2014 Measure Category : Plumblna Low Flow Aerators:Aerator -0.5 gpm Residential _ow Flow Aerator -Direct Install -Electric Only -0.5 gpm -ID nstall Low Flow Aerator 04/14/2014 _ow Flow Aerator -Mail By Request -Any Water Heat Fuel -0.5 gpm -ID Install Low Flow Aerator 04/14/2014 ,_ow Flow Aerator -Mail By Request -Electric Only - 0.5 gpm -ID Install Low Flow Aerator 04/14/2014 ,-ow Flow Aerator -Retail -Any Water Heat Fuel -0.5 gpm -ID nstall Low Flow Aerator 04/14/2014 Low Flow Aerators:Aerator • 1.5 gpm Residential ,_ow Flow Aerator -Direct Install -Electric Only -1.5 gpm -ID nstall Low Flow Aerator 04/14/2014 _ow Flow Aerator -Mail By Request -Any Water Heat Fuel -1.5 gpm -ID nstall Low Flow Aerator 04/14/2014 ,-ow Flow Aerator -Mail By Request -Electric Only - 1.5 gpm -ID Install Low Flow Aerator 04/14/2014 ,-ow Flow Aerator -Retail -Any Water Heat Fuel -1.5 gpm -ID 11nstall Low Flow Aerator 04/14/2014 Low Flow Showerheads:Low Flow Showerhead+ThV Residential Report Date: 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 20 of 55 Rocky Mountain Power Attachment 2 Page 77 of 112 Case No. PAC·E·16--14 Gross incremental annual Savings unit electric savings {kWh/yr) 25.44 Measure 24.71 Measure 22.33 Measure 22.33 Measure 23.26 Measure 24.42 Measure 24.42 Measure 25.44 Measure 18.14 Measure 18.14 Measure 18.9 Measure 17.44 Measure 17.44 Measure 18.17 Measure 23.72 Measure 23.72 Measure 24.71 Measure 74.12 Measure 30.67 Measure 62.59 Measure 28.25 Measure 30.52 Measure 12.63 Measure 25.77 Measure 11.63 Measure Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Program : Home Energy Savings ~,---... ~. ,-ow Flow Showerhead 1.5 gpm + Thermostatic Valve -Direct Install -Install a Low Flow Showerhead with a Thermostatic Valve 04/14/2014 Electric Onlv -ID ,_ow Flow Showerhead 1.5 gpm + Thermostatic Valve -Mail By Request - lA.nv Water Heat Fuel -ID Install a Low Flow Showerhead with a Thermostatic Valve 04/14/2014 ow Flow Showerhead 1.5 gpm + Thermostatic Valve -Mail By Request -Install a Low Flow Showerhead with a Thermostatic Valve 04/14/2014 Electric Onlv -ID ow Flow Showerhead 1.5 gpm + Thermostatic Valve -Retail -Any Water Install a Low Flow Showerhead with a Thermostatic Valve Heat Fuel -ID 04/14/2014 Low Flow Showerheads:Showerhead -1.50 gpm Residential ow Flow Showerhead -Direct Install -Electric Only -1.50 gpm -ID !install a Low Flow Showerhead 04/14/2014 ow Flow Showerhead -Mail By Request -Any Water Heat Fuel -1.50 I 04/14/2014 aom -ID 11nstall a Low Flow Showerhead ow Flow Showerhead -Mail By Request -Electric Only -1.50 gpm -ID I 1tnstall a Low Flow Showerhead 04/14/2014 ow Flow Showerhead -Retail -Any Water Heat Fuel -1 .50 gpm -ID I 11nstall a Low Flow Showerhead 04/14/2014 Low Flow Showerheads:Showerhead -1.75 gpm Residential ow Flow Showerhead -Direct Install -Electric Only -1. 75 gpm -ID ,nstall a Low Flow Showerhead 04/14/2014 ow Flow Showerhead -Mail By Request -Any Water Heat Fuel -1. 75 I 04/14/2014 anm-lD 11nstall a Low Flow Showerhead ow Flow Showerhead -Mail By Request -Electric Only -1. 75 gpm -ID 'install a Low Flow Showerhead I 04/14/2014 ow Flow Showerhead -Retail -Any Water Heat Fuel -1.75 gpm -ID I 11nstall a Low Flow Showerhead 04/14/2014 Low Flow Showerheads:Showerhead -2.00 gpm Residential ow Flow Showerhead -Direct Install -Electric Only -2.00 gpm -ID [ 11nstall a Low Flow Showerhead 04/14/2014 ow Flow Showerhead -Mail By Request -Any Water Heat Fuel -2.00 ~nstall a Low Flow Showerhead 04/14/2014 JOm-lD ow Flow Showerhead -Mail By Request -Electric Only -2.00 gpm -ID :Install a Low Flow Showerhead 04/14/2014 ow Flow Showerhead -Retail -Any Water Heat Fuel -2.00 gpm -ID I 11nstall a Low Flow Showerhead 04/14/2014 Thermostatic Valves:Thermostatic Valve Residential Thermostatic Valve -Direct Install -Electric Only -ID 11nstall Thermostatic Valve 04/14/2014 Thermostatic Valve -Mail By Request -Any Water Heat Fuel -ID Install Thermostatic Valve 04/14/2014 Thermostatic Valve -Mail By Request -Electric Only -ID Install Thermostatic Valve 04/14/2014 Thermostatic Valve -Retail -Any Water Heat Fuel -ID Install Thermostatic Valve 04/14/2014 Report Date : 04/27/2015 Energy Savings Calculation method -., RMP Deemed RMP Deemed RMP Deemed RMP Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 21 of 55 Rocky Mountain Power Attachment 2 Page 78 of 112 Case No. PAC-E·1&-14 Gross incremental annual Savings unit electric savings (kWh/yr) ' 343 Measure 190 Measure 284 Measure 172 Measure 307 Measure 170 Measure 260 Measure 157 Measure 222 Measure 123 Measure 187 Measure 121 Measure 139 Measure 77 Measure 117 Measure 81 Measure 36.08 Measure 20.31 Measure 24.17 Measure 15.46 Measure Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Program : Home Energy Saving• ~easure Category : Water Heating Water Heater:Heat Pump Water Heater HPWH -Tier 1 -50 to 75 gallons -Any Heat Type -Unheated Buffer ocation -ID HPWH -Tier 1 -50 to 75 gallons -Electric Furnace Heated Home - nterior Location -ID IHPWH -Tier 1 -50 to 75 gallons -Gas Heated Home -Interior Location - ID HPWH -Tier 1 -50 to 75 gallons -Heat Pump Heated Home -Interior " ocation -ID HPWH -Tier 1 -50 to 75 gallons -Zonal Electric Heated Home -Interior ocation -ID HPWH -Tier 1 -greater than 75 gallons -Any Heat Type -Unheated Buffer Location -ID HPWH -Tier 1 -greater than 75 gallons -Electric Furnace Heated Home - Interior Location -ID IHPWH -Tier 1 -greater than 75 gallons -Gas Heated Home -Interior Location -ID 1-iPWH -Tier 1 -greater than 75 gallons -Heat Pump Heated Home - nterior Location -ID HPWH -Tier 1 -greater than 75 gallons -Zonal Electric Heated Home - interior Location -ID Water Heater:Water Heater [Electric Water Heater -0.93 EF or greater -66 gallons or greater -ID Electric Water Heater -0.94 EF or greater -40 to 49 gallons -ID Electric Water Heater -0.95 EF or greater -50 to 65 gallons -ID ~easure Category : Whole Home Whole Home:Whole Home -Central Air Conditioner hole Home Upgrade Package -Gas Furnace with CAC -ID Whole Home:Whole Home· Ductless Heat Pump hole Home Upgrade Package • Ductless Heat Pump -ID Whole Home:Whole Home· Heat Pump Whole Home Upgrade Package -Heat Pump Conversion -ID Whole Home Upgrade Package -Heat Pump Upgrade -ID Residential IE lectric heat pump water heater Electric heat pump water heater 1,:: lectric heat pump water heater Electric heat pump water heater Electric heat pump water heater Electric heat pump water heater Electric heat pump water heater Electric heat pump water heater Electric heat pump water heater Electric heat pump water heater Residential Energy efficient electric water heater Energy efficient electric water heater Energy efficient electric water heater Residential ombine attic insulation. 95%+ AFUE gas furnce with ECM lower, duct insulation & sealin Residential ombine attic insulation. ductless heat pump Residential Combine attic insulation. heat pump conversion with best practices install and sizing. and duct insulation & sealing Combine attic insulation. heat pump upgrade with best oractices install and sizina. and duct insulation & sealina Report Date: 04/27/2015 Effective Date 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 04/14/2014 08/20/2012 08/20/2012 08/20/2012 04/14/2014 04/14/2014 04/14/2014 04/14/2014 Energy Savings Calculation method RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed Page 22 of 55 Rocky Mountain Po..wr Attachment 2 Page 79 ol 112 Case No. PAC-E·16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 881 Measure 556 Measure 1,547 Measure 1,189 Measure 648 Measure 1,811 Measure 833 Measure 2,169 Measure 1,686 Measure 957 Measure 175 Measure 99 Measure 131 Measure 0 Measure 0 Measure 0 Measure 0 Measure Rocky Mountain Power Attachment 2 Page 80 of 112 Rocky Mountain Power Energy Efficiency Measures for Idaho Case No. PAC-E~1&.14 Measures Effective on 04/27/2015 Effective Date Energy Savings Gross incremental annual Savings unit Calculation method electric savings (kWh/yr) Program : Home Energy Savings Report Date : 04/27/2015 Page 23 of 55 --- Program : Low Income Weetherlzatlon ll,leaaure Category : Appliances Refrigerators:Refrigerator 01 Refrigerator Replacement -ID Measure Cateaorv : Bulldlng Shell Air Sealing:Air Sealed/Infiltration 18 Air Sealed/Infiltration -ID Doors:Thermal Doors 1 Thermal Doors -ID Grounds:Ground Cover 6 Ground Cover -ID lnsulation:Ceiling Insulation 9 Ceiling Insulation -ID lnsulation:Floor Insulation 11 Floor Insulation -ID lnsulation:Wa/1 Insulation 8 Wall Insulation -ID Ventilation:Attic Ventilation 10 Attic Ventilation -ID Weatherization:Home Weatherization Home Repair Cost -ID ID Weatherization -ID Windows: Window Replacement 01 Storm Windows -ID 32 Double Glass Replacement -ID Measure Category : Health and Safety Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Residential Low Income Energy Star refrigerators 01/01 /2014 Residential Low Income ir sealing 01/01 /2014 Residential Low Income hermal doors 01/01 /2014 Residential Low Income ~round cover when installed with floor insulation 01/01 /2014 Residential Low Income eiling insulation 01/01 /2014 Residential Low Income Floor insulation 01/01 /2014 Residential Low Income all insulation 01/01 /2014 Residential Low Income ~ttic ventilation 01/01 /2014 Residential Low Income Repairs necessary to install energy efficient measures 01/01 /2014 This is not a distinct measure but allows for a deemed savings amount to be applied to shell measures/a set kWh per home 01/01 /2014 Residential Low Income Storm windows 01/01 /2014 Replacement windows with a U-value of 0.35 or less 01/01 /2014 Report Date : 04/27/2015 Energy Savings Calculation method RMPDeemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed I RMP Deemed I RMPDeemed RMP Deemed RMP Deemed RMP Deemed Page 24 of55 Rocky Mountain Power Attachment 2 Page 81 ol 112 Case No. PAC-E-1&14 Gross incremental annual electric savings (kWh/yr) Savings unit -~ Savings included in "ID Home Weatherization -ID" measure Savings included in "ID Home Weatherization -ID" measure Savings included in "ID Home Weatherization -ID" measure 0 Home Savings included in "ID Weatherization -ID" measure I Home Savings included in "ID Weatherization -ID" measure I Home Savings included in "ID I Weatherization -ID" measure Home 0 Home 0 Home 1,308 Home Savings included in "ID Home Weatherization -ID" measure Savings included in "ID Home Weatherization -ID" measure Program : Low Income Weatherlzatlon Health and Safety:Health and Safety 74 Health and Safety -ID ~easure Category : HVAC Controls and Thermostats:Thermostat :14 Clock Thermostat -ID Ducting:Duct Sealing and/or Insulation ,15 Duct Insulation/Sealing Insulation -ID 81 Duct Sealing -ID Heating:Furnace Repair 71 Furnace Repair -ID Heating:Furnace Replacement 72 Furnace Replacement -ID Measure Category : Lighting General Service Lamps:CFL 1 Fluorescent Lighting -ID Measure Category : Water Heating Flow Control:Faucet Aerators 01 Faucet Aerators -ID Flow Control:Low Flow Shower Head 19 Low Flow Shower Head -ID Pipe lnsulation:Pipe Insulation 12 Pipe Insulation HYO -ID Water Heater:Water Heater Repair 40 Water Heater Repair -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Residential Low Income Health and safety measures related to electric usage 01 /0112014 Residential Low Income imed thermostats 01 /01/2014 Residential Low Income uct insulation 01 /0112014 uct sealing 01 /0112014 Residential Low Income ,Electric furnace repair 01 /01/2014 Residential Low Income !Electric furnace replacement 01 /01/2014 Residential Low Income Energy Star CFLs 01/01/2014 Residential Low Income Faucet aerators 01 /01/2014 Residential Low Income howerheads 01 /01/2014 Residential Low Income ater pipe wrap 01 /01/2014 Residential Low Income :Electric water heater repair 01/01/2014 Report Date : 04/27/2015 I I Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 25' of 55 Rocky Mountain Po.....-er Attachment 2 Page 82 of 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) 0 Savings included in "ID Weatherization -ID" measure Savings included in "ID Weatherization -ID" measure Savings included in "ID Weatherization -ID" measure Savings included in "ID Weatherization -ID" measure Savings included in "ID I I Weatherization -ID" measure Savings included in "ID Weatherization -ID" measure Savings included in "ID I Weatherization -ID" measure Savings included in "ID Weatherization -ID" measure Savings included in "ID Weatherization -ID" measure Savings included in "ID I Weatherization -ID" measure Savings unit Home Measure Home Home Measure Measure Home Measure Measure Home Measure Program : Low Income Weatherlzatlon -Water Heater:Water Heater Replacement 73 Water Heater Replacement -ID Measure Cateaory : Whole Home Whole Home:Whole Home Energy Conservation Education Kit -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Residential Low Income Electric water heater replacement 01/01 /2014 Residential Low Income 01/01/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed Page 26 of 55 Rocky Mountain Pov.,er Attachment 2 Page 83 of 112 Case No. PAC-E-16.14 Gross incremental annual electric savings (kWh/yr) Savings unit Savings included in "ID Measure Weatherization -ID" measure Savings included in "ID Measure Weatherization -ID" measure Program : See Ya Later, Refrigerator ~easure Category : Appliances Freezers:Freezer Recycling reezer Recycling -ID reezer Recycling -Secondary Market Intervention -ID Refrigerators:Refrigerator Recycling Refrigerator Recycling -ID Refrigerator Recycling -Secondary Market Intervention -ID Measure Cateaory : Food Service Egu1Dffl811t Freezers:Residential Freezer Recycling reezer Recycling (residential used in a business) -ID Refrigerators:Residential Refrigerator Recycling I Refrigerator Recycling (residential used in a business) -ID Measure Category : Lighting General Service Lamps:CFL Kit Energy Savings Kit (residential used in a business)-ID :Energy Savings Kit -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Residential Freezer recycling 07/01/2014 Freezer recycling, retailer pickup 07/01/2014 Residential Refrigerator recycling 07/01/2014 Refrigerator recycling, retailer pickup 07/01/2014 Non-Residential Freezer recycling, residential unit at non-residential site 07/01/2014 Non-Residential jRefrigerator recycling, residential unit at non-residential site 07/01/2014 Non-Residential Energy savings kit 07/01/2014 nergy savings kit 01 /01/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 27 of 55 Rocky Mountain Power Attachment 2 Page 84 of 1 12 Case No. PAC-E-1&14 Gross incremental annual Savings unit electric savings (kWh/yr) 1,033 Measure 1,033 Measure 1,022 Measure 1,022 Measure 1,033 Measure 1,022 Measure 30.23 Measure 30.23 Measure r rogram : wattsmart Business ••asure Category : Appliances Clothes Washers:Commercial Clothes Washer igh-Efficiency Clothes Washer (Must have Electric Water Heating) - ommercial · ENERGY STAR Qualified· ID Clothes Washers:Residential Clothes Washer • Electric DHW & lothes Washer -3.2 MEF or Higher -Electric DHW & Electric Dryer residential used in a business · ID Clothes Washers:Residential Clothes Washer -Electric DHW & lothes Washer -3.2 MEF or Higher -Electric DHW & Gas Dryer residential used in a business -ID Clothes Washers:Residential Clothes Washer· Gas DHW & lothes Washer - 3.2 MEF or Higher -Gas DHW & Electric Dryer residential used in a business -ID Clothes Washers:Residential Clothes Washer -Gas DHW & Gas Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Non-Residential nergy Star Qualified High Efficiency Clothes Washer 11/1 3/2014 Non-Residential Energy efficient clothes washers 11/13/2014 Non-Residential Energy efficient clothes washers 11/13/2014 Non-Residential Energy efficient clothes washers 11/13/2014 Non-Residential :lothes Washer -3.2 MEF or Higher -Gas DHW & Gas Dryer (residential nergy efficient clothes washers 11/13/2014 sed in a business -ID Water Heater:Residential Water Heater Non-Residential Electric Water Heater (.93 EF or greater) 66 gallon (residential used in a Energy efficient electric water heaters 11/13/2014 business\ -ID Electric Water Heater (.94 EF or greater) 40 gallon (residential used in a Energy efficient electric water heaters 11/13/2014 husiness \ -ID Electric Water Heater (.95 EF or greater) 50 gallon (residential used in a Energy efficient electric water heaters 11/13/2014 husiness l -ID ~asure Category : Bullcllna Shell lnsulation:Roof/Attic Insulation Non-Residential ;Roof/Attic Insulation -New Construction -ID ew Construction Roof/Attic Insulation 11/13/2014 :Roof/Attic Insulation -Retrofit -ID !Retrofit Roof/Attic Insulation 11/13/2014 lnsulation:Wa/1 Insulation Non-Residential all Insulation -New Construction -ID ew construction Wall Insulation 11/13/2014 all Insulation -Retrofit -ID !Retrofit Wall Insulation 11/13/2014 Roof:Cool Roof Non-Residential ool Roof -New Construction -ID ew Construction, Cool Roof. reflective roofing 11/13/2014 ool Roof -Retrofit -ID etrofit,Cool Roof, reflective roofing 11/13/2014 Windows:Window Film Non-Residential indow Film: Existing Windows -ID indow Film 11/13/2014 Report Date : 04/27/2015 Energy Savings Calculation method RTF Deemed I RTF Deemed I RTF Deemed I I RTF Deemed I RTF Deemed I RTF Deemed RTF Deemed RTF Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Calculation Page 28 of 55 Rocky Mountain Po'Ner Attachment 2 Page 85 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 391 I Measure 143 Measure 54 I Measure 106 I Measure 16 Measure 175 Measure 99 Measure 131 Measure 0.035 Sq. ft. 0.08 Sq. ft. 0.011 Sq. ft. 0.064 Sq. ft. 0.33 Sq. ft. 0.33 Sq. ft. Savings vary by install Site-specific Program : wattsmart Business Windows:Window Replacement indows -Retrofit: Assembly -ID indows -Retrofit: Site-Built -ID Windows:Window Upgrade indows -New Construction: Assembly -ID indows -New Construction: Site-Built -ID ~easure Category : Compressed Air Compressed Air:Compressed air end use reduction ompressed Air End Use Reduction -Retrofit ID Compressed Air:Low-pressure drop filter ow-pressure drop filter (New Construction) -ID ow-pressure drop filter (Retrofit) -iD Compressed Air:Outside air intake Outside air intake (New Construction) -ID b utside air intake (Retrofit) -ID Compressed Air:Receiver capacity addition Receiver capacity addition (New Construction) -ID Receiver capacity addition (Retrofit) -ID Compressed Air:Refrigerated cycling dryer Refrigerated cycling dryer (New Construction) -ID Refrigerated cycling dryer (Retrofit) -ID Compressed Air:VFD controlled compressor VFD controlled compressor (New Construction) -ID VFD controlled compressor (Retrofit) -ID Compressed Air:Zero loss condensate drain Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Non-Residential 1Retrofit preassembled windows 11/13/2014 ,Retrofit Site built windows 11/13/2014 Non-Residential ew construction preassembled windows 11/13/2014 ew construction site built windows 11/13/2014 Non-Residential !Replace inappropriate or inefficient compressed air end uses ith functionally equivalent alternatives, leak reduction, or 11/13/2014 solation valves. Non-Residential ow pressure drop filter in place of regular filter 11/13/2014 ow pressure drop filter in place of regular filter 11/13/2014 Non-Residential Permanent ductwork between compressor and outdoors for 11/13/2014 omoressor intake air 0 ermanent ductwork between compressor and outdoors for 11/13/2014 t omoressor intake air Non-Residential Incremental receiver capacity in excess of 2 gal/scfm of trim 11/13/2014 ~omoressor canacitv Incremental receiver capacity in excess of 2 gal/scfm of trim omnressor canacitv 11/13/2014 Non-Residential '-'ycling refrigerated dryer in place of nan cycling refrigerated 11/13/2014 jrver ::ycling refrigerated dryer in place of nan cycling refrigerated 11/13/2014 drver Non-Residential VFD compressor in place of fixed speed compressor (oil-11/13/2014 nooded onlv not oil-free\ VFD compressor in place of fixed speed compressor ( oil-11/13/2014 flooded onlv. not oil-free\ Non-Residential Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Calculation RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Calculation RMP Calculation Page 29 of 55 Rocky Mountain Power Attachment 2 Page 86 of 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) Savings unit f .. configuration I 4.425 Sq. ft. 4.065 Sq. ft. 1.614 Sq. ft. 1.219 Sq. ft. Savings vary by install Site-specific configuration 6.79 Scfm 6.79 Scfm 48.97 Hp 48.97 hp Gal above 2 13.1 nal/scfm 13.1 Gal above 2 aal/scfm 12.73 Scfm/hr 12.73 Scfm/hr Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Rocky Mountain Po'Ner Attachment 2 Page 87 of 112 Rocky Mount ain Power Energy Efficiency Measures for Idaho Case No. PAC-E·16-14 Measures Effective on 04/27/2015 Effective Date Energy Savings Gross incremental annual Savings unit Calculation method electric savings (kWh/yr) 1Program : wattsmart Business -· ero loss condensate drain (New Construction)-ID a-loss conden 1sate drain in place of conventional timer drain 11/13/2014 RMP Deemed 786.37 Measure ero loss condensate drain (Retrofit) -ID a-loss conden 1sate drain in place of conventional timer drain 11/13/2014 RMP Deemed 786.37 Measure lweasure Category : Cusj9m Additional Measures:Dust Collection Non-Residential ust Collection (New Construction wCode) Custom -ID ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiauration ustom engine ust Collection (Retrofit & NCMR woCode} Custom -ID ·ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiouration ustom engine Additional Measures:Other Controls Non-Residential ther Controls (New Construction wCode} Custom -ID ·ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiauration ustom engine ther Controls (Retrofit & NCMR woCode) Custom -ID ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiauration ustom engine Building Shell:Cool Roof Non-Residential ool Roof (New Construction wCode) Custom -ID ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiouration ustom engine ool Roof (Retrofit & NCMR woCode) Custom -ID ·ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiauration ustom engine Building She/1:Exterior Shading Non-Residential Exterior Shading (New Construction wCode) Custom -ID ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiauration ustom engine [Exterior Shading (Retrofit & NCMR woCode) Custom -ID ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiouration ustom engine Building She/1:Glazing Non-Residential lazing (New Construction wCode) Custom -ID ·ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiauration ustom engine lazing (Retrofit & NCMR woCode) Custom -ID ·ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiouration ustom engine Building She/1:lnsulation Package Non-Residential :insulation Package (New Construction wCode} Custom -ID ·ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiauration ustom engine [Insulation Package (Retrofit & NCMR woCode} Custom -ID ·ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiouration ustom engine Building She/1:0ther Building Shell Non-Residential '!her Building Shell (New Construction wCode) Custom -ID ·ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiauration ustom engine, ther Building Shell (Retrofit & NCMR woCode} Custom -ID •ering for industrial and large commercial 11/13/2014 RMP Calculation Savings vary by install Site-specific confiauration ustom engine Report Date : 04/27/2015 Page 30 of 55 Program : wattsmart Business ----------Building She/1:Roof/Attic Insulation Roof/Attic Insulation (New Construction wCode) Custom -ID Roof/Attic Insulation (Retrofit & NCMR woCode) Custom -ID Building She/1:Wall Insulation all Insulation (New Construction wCode) Custom -ID all Insulation (Retrofit & NCMR woCode) Custom -ID Compressed Air:Control ontrol (New Construction wCode) Custom -ID ontrol (Retrofit & NCMR woCode) Custom -ID Compressed Air:lmprovements !Improvements (New Construction wCode) Custom -ID :improvements (Retrofit & NCMR woCode) Custom -ID Compressed Air:VFD Compressor FD Compressor (New Construction wCode) Custom -ID FD Compressor (Retrofit & NCMR woCode) Custom -ID Energy Management:lndustrial Recommissioning :industrial Recommissioning Custom -ID Energy Management:Persistent Recommissioning ersistent Recommissioning Custom -ID Energy Management:Recommissioning ;Recommissioning Custom -ID Energy Management:Strategic Energy Mgmt trategic Energy Management Custom -ID HVAC:Chiller hiller (New Construction wCode) Custom -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/201 4 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 Report Date : 04/27/2015 I Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation Page 31 of 55 Rocky Mountain Power Attachment 2 Page 88 of 112 Case No. PAC-E-16--14 Gross incremental annual electric savings (kWh/yr) Savings vary by install confi uration Savings vary by install configuration Savings vary by install confi uration Savings vary by install configuration Savings vary by install confi uration Savings vary by install configuration Savings vary by install confi uration Savings vary by install configuration Savings vary by install confi uration Savings vary by install configuration Savings vary by install configuration Savings vary by install configuration Savings vary by install configuration Savings vary by install configuration Savings vary by install configuration Savings unit Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific 'Program : wattsmart Business hiller (Retrofit & NCMR woCode) Custom -ID HVAC:C02 Air Controls 02 Air Controls (New Construction wCode) Custom -ID 02 Air Controls (Retrofit & NCMR woCode) Custom -ID HVAC:Cooling Tower· VFD Fan ooling Tower -VFD Fan (New Construction wCode) Custom -ID ooling Tower -VFD Fan (Retrofit & NCMR woCode) Custom -ID HVAC:DDC DC (New Construction wCode) Custom -ID DC (Retrofit & NCMR woCode) Custom -ID HVAC:Economizer :Economizer (New Construction wCode) Custom -ID :Economizer (Retrofit & NCMR woCode) Custom -ID HVAC:Evaporative Cooler :Evaporative Cooler (New Construction wCode) Custom -ID !Evaporative Cooler (Retrofit & NCMR woCode) Custom -ID HVAC:Fan Controls IFan Controls (New Construction wCode) Custom -ID IFan Controls (Retrofit & NCMR woCode) Custom -ID HVAC:Fan-Powered VAV Fan-Powered VAV (New Construction wCode) Custom -ID Fan-Powered VAV (Retrofit & NCMR woCode) Custom -ID HVAC:Garage CO Fan Conts arage CO Fan Conts (New Construction wCode) Custom -ID arage CO Fan Conts (Retrofit & NCMR woCode) Custom -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial an~ large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Report Date : 04/27/2015 I Energy Savings Calculation method I RMP Calculation I RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation Page 32 of 55 Rocky Mountain Power Attachment 2 Page 89 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) s~i;;~;ry by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific frogram :_wattsmart Business HVAC:Groundwater-Source Heat Pumps Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Non-Residential K,roundwater-Source Heat Pumps (New Construction wCode) Custom -IC Custom engineering for industrial and large commercial 11 /13/2014 '-"roundwater-Source Heat Pumps (Retrofit & NCMR woCode) Custom -Custom engineering for industrial and large commercial 11 /13/2014 ID HVAC:Heat Pump Non-Residential Heat Pump (New Construction wCode} Custom -ID Custom engineering for industrial and large commercial 11 /13/2014 Heat Pump (Retrofit & NCMR woCode} Custom -ID Custom engineering for industrial and large commercial 11/13/2014 HVAC:Heat Recovery Non-Residential Heat Recovery (New Construction wCode) Custom -ID Custom engineering for industrial and large commercial 11/13/2014 Heat Recovery (Retrofit & NCMR woCode} Custom -ID Custom engineering for industrial and large commercial 11/13/2014 HVAC:High-Effic. Air Cond. Non-Residential High-Effie. Air Cond. (New Construction wCode) Custom -ID Custom engineering for industrial and large commercial 11/13/2014 High-Effie. Air Cond. (Retrofit & NCMR woCode} Custom -ID tustom engineering for industrial and large commercial 11 /13/2014 HVAC:Other HVAC Non-Residential Pther HVAC (New Construction wCode} Custom -ID Custom engineering for industrial and large commercial 11 /13/2014 Pther HVAC (Retrofit & NCMR woCode) Custom -ID Custom engineering for industrial and large commercial 11/13/2014 HVAC:Package HVAC Non-Residential Package HVAC (New Construction wCode} Custom -ID Custom engineering for industrial and large commercial 11/13/2014 Package HVAC (Retrofit & NCMR woCode) Custom -ID Custom engineering for industrial and large commercial 11/13/2014 HVAC:Premium RTU Non-Residential Premium RTU (New Construction wCode} Custom -ID Custom engineering for industrial and large commercial 11/13/2014 Premium RTU (Retrofit & NCMR woCode) Custom -ID Custom engineering for industrial and large commercial 11/13/2014 HVAC:VAV Nan-Residential AV (New Construction wCode} Custom -ID ustom engineering for industrial and large commercial 11/13/2014 AV (Retrofit & NCMR woCode} Custom -ID ustom engineering for industrial and large commercial 11/13/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation Page 33 of 55 Rocky Mountain Po"Wer Attachment 2 Page 90 of 112 Case No. PAC-E-16.14 Gross incremental annual electric savings (kWh/yr) - > - configuration Savings vary by install confiouration Savings vary by install confiouration Savings vary by install confiauration Savings vary by install confiouration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiouration Savings vary by install confiQuration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install configuration Savings vary by install Savings unit Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Program : wattsmart Business HVAC:VFD Fan FD Fan (New Construction wCode) Custom -ID FD Fan (Retrofit & NCMR woCode) Custom -ID HVAC:VFD Pump f./FD Pump (New Construction wCode) Custom -ID r,JFD Pump (Retrofit & NCMR woCode) Custom -ID HVAC:Water-Loop Heat Pump Water-Loop Heat Pump (New Construction wCode) Custom -ID r,\'ater-Loop Heat Pump (Retrofit & NCMR woCode) Custom -ID lrrigation:Pivots and Linear Systems K;enter Pivot Replacing Set Move System (Retrofit) -ID !Sprinkler Package Replacement (Retrofit) -ID lrrigation:Pump Upgrades Pump Replacement / Rebuild (Retrofit) -ID Pump Upgrades (New Construction wCode) Custom -ID Pump Upgrades (Retrofit & NCMR woCode) Custom -ID Jrrigation:System Redesign !System Redesign (New Construction wCode) Custom -ID !System Redesign (Retrofit & NCMR woCode) Custom -ID !System Redesign (Retrofit) -ID lrrigation:Variable Frequency Drives :Irrigation Pump VFD -ID lrrigation:Wheel Line/Hand Line Equipment [upgrade Wheel Line / Hand Line Equipment (Retrofit) -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date - Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential New center pivot replacing previous (non-pivot) system 11/13/2014 Replace sprinkler package on pivot or linear 11/13/2014 Non-Residential Replace or rebuild irrigation pump 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Nan-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Redesign irrigation system, including distribution equipment 11/13/2014 Non-Residential dd VFD to irrigation pump 11/13/2014 Non-Residential [Replace wheel lines, hand lines, and/or components 11/13/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation Page 34 of 55 Rocky Mountain Power Attachment 2 Page 91 of 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) configuration Savings vary by install configuration Savings vary by install configuration Savings vary by install confiauration Savings vary by install confiouration Savings vary by install confiauration Savings vary by install confiouration Savings vary by install confiauration Savings vary by install confiau ration Savings vary by install confiQuratian Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiQuration Savings vary by install confiauration Savings vary by install confiQuration Savings vary by install configuration Savings vary by install Savings unit I Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Program : wattsmart Business hereof Motors:Electronically Commutated Motor Non-Residential lectronically Commutated Motor (New Construction wCode) Custom -ID ustom engineering for industrial and large commercial 11/13/2014 Electronically Commutated Motor (Retrofit & NCMR woCode) Custom· ID "ustom engineering for industrial and large commercial 11/13/2014 Motors:Other Motors Non-Residential ,ther Motors (New Construction wCode) Custom -ID ustom engineering for industrial and large commercial 11/13/2014 ,ther Motors (Retrofit & NCMR woCode) Custom -ID ustom engineering for industrial and large commercial 11/13/2014 Motors:Pump Motors Non-Residential ump Motors (New Construction wCode) Custom -ID ustom engineering for industrial and large commercial 11 /13/2014 ump Motors (Retrofit & NCMR woCode) Custom -ID ustom engineering for industrial and large commercial 11 /13/2014 Motors:Pump with VFD Non-Residential ump with VFD (New Construction wCode) Custom -ID ustom engineering for industrial and large commercial 11 /13/2014 ump with VFD (Retrofit & NCMR woCode) Custom -ID ustom engineering for industrial and large commercial 11/13/2014 Motors:VFD Motors Non-Residential FD Motors (New Construction wCode) Custom -ID ustom engineering for industrial and large commercial 11 /13/2014 FD Motors (Retrofit & NCMR woCode) Custom -ID ustom engineering for industrial and large commercial 11 /13/2014 Motors:VSD Non-Residential SD (New Construction wCode) Custom -ID ustom engineering for industrial and large commercial 11 /13/2014 SD (Retrofit & NCMR woCode) Custom -ID ustom engineering for industrial and large commercial 11/13/2014 Refrigeration:2-Stage Ammonia Non-Residential -Stage Ammonia (New Construction wCode) Custom -ID ustom engineering for industrial and large commercial 11/13/2014 -Stage Ammonia (Retrofit & NCMR woCode) Custom -ID ustom engineering for industrial and large commercial 11/13/2014 Refrigeration:Box Insulation Non-Residential ox Insulation (New Construction wCode) Custom -ID ustom engineering for industrial and large commercial 11/13/2014 ox Insulation (Retrofit & NCMR woCode) Custom -ID ustom engineering for industrial and large commercial 11 /13/2014 Report Date : 04/27/2015 I Energy Savings I Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation Page 35 of 55 Rocky Mountain Power Attachment 2 Page 92 of 112 Case No. PAC-E-16-14 Gross incremental annual I Savings unit electric savings (kWh/yr) .... ·,a.=-;; :a configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific Program : wattsmart Business Refrigeration:Case/Point of Sale Lighting Case/Point of Sale Lighting (New Construction wCode) Custom -ID Case/Point of Sale Lighting (Retrofit & NCMR woCode) Custom -ID Refrigeration:C02 Scrubber ~02 Scrubber (New Construction wCode) Custom -ID ~02 Scrubber (Retrofit & NCMR woCode) Custom -ID Refrigeration:Compressor VFD ~ompressor VFD (New Construction wCode) Custom -ID ~ompressor VFD (Retrofit & NCMR woCode) Custom -ID Refrigeration:Condenser Fan VFDs ~ondenser Fan VFDs (New Construction wCode) Custom -ID ~ondenser Fan VFDs (Retrofit & NCMR woCode) Custom -ID Refrigeration:Condensing Press Cont ~ondensing Press Cont (New Construction wCode) Custom -ID ~ondensing Press Cont (Retrofit & NCMR woCode) Custom -ID Refrigeration:Controls Refrigeration ~ontrols Refrigeration (New Construction wCode) Custom -ID ~ontrols Refrigeration (Retrofit & NCMR woCode) Custom -ID Refrigeration:EE Evaporator Coils EE Evaporator Coils (New Construction wCode) Custom -ID EE Evaporator Coils (Retrofit & NCMR woCode) Custom -ID Refrigeration:Evap & AirCool Condense :Evap & AirCool Condense (New Construction wCode) Custom -ID IEvap & AirCool Condense (Retrofit & NCMR woCode) Custom -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Non-Residential ~ustom engineering for industrial and large commercial 11/13/2014 ~ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ~ustom engineering for industrial and large commercial 11/13/2014 ~ustom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial ana large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation Page 36 of 55 Rocky Mountain Power Attachment 2 Page 93 of 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) -· " configuration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install configuration Savings vary by install Savings unit I Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Program : wattsmart Business Refrigeration:Evaporator Fan VFD Evaporator Fan VFD (New Construction wCode) Custom -ID Evaporator Fan VFD (Retrofit & NCMR woCode) Custom -ID Refrigeration:Evaporator System !Evaporator System (New Construction wCode) Custom -ID !Evaporator System (Retrofit & NCMR woCode) Custom -ID Refrigeration:Fan VFDs IFan VFDs (New Construction wCode) Custom -ID an VFDs (Retrofit & NCMR woCode) Custom -ID Refrigeration:Floating Head Press Cont loating Head Press Cont (New Construction wCode) Custom -ID '.Floating Head Press Cont (Retrofit & NCMR woCode) Custom -ID Refrigeration:Floating Suction Control loating Suction Control (New Construction wCode) Custom -ID loating Suction Control (Retrofit & NCMR woCode) Custom -ID Refrigeration:HE Evaporative Fan E Evaporative Fan (New Construction wCode) Custom -ID E Evaporative Fan (Retrofit & NCMR woCode) Custom -ID Refrigeration:Heat Pump Desuper eat Pump Desuper (New Construction wCode) Custom -ID eat Pump Desuper (Retrofit & NCMR woCode) Custom -ID Refrigeration:High Speed Doors igh Speed Doors (New Construction wCode) Custom -ID igh Speed Doors (Retrofit & NCMR woCode) Custom -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Non-Residential ustom engineering for industrial and large commercial 11/13/2014 ustom engineering for industrial and large commercial 11/13/2014 Report Date : 04/27/2015 I Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation Page 37 of 55 Rocky Mountain Pov.<er Attachment 2 Page 94of112 Case No. PAC.E.16--14 Gross incremental annual Savings unit electric savings (kWh/yr) configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific configuration Savings vary by install Site-specific confi uration Savings vary by install Site-specific Program : wattsmart Business - Refrigeration:High-Effic. Cases High-Effie. Cases (New Construction wCode) Custom -ID High-Effie. Cases (Retrofit & NCMR woCode) Custom -ID Refrigeration:Humidistat I Anti-Sweat Humidistat / Anti-Sweat (New Construction wCode) Custom -ID Humidistat / Anti-Sweat (Retrofit & NCMR woCode) Custom -ID Refrigeration:Other Refrigeration b ther Refrigeration (New Construction wCode) Custom -ID b ther Refrigeration (Retrofit & NCMR woCode) Custom -ID Refrigeration:Package Refrigeration Package Refrigeration (New Construction wCode) Custom -ID backage Refrigeration (Retrofit & NCMR woCode) Custom -ID Refrigeration:Plate Cooler Plate Cooler (New Construction wCode) Custom -ID b 1ate Cooler (Retrofit & NCMR woCode) Custom -ID Refrigeration:Solid Door Refrigerator Solid Door Refrigerator (New Construction wCode) Custom -ID Solid Door Refrigerator (Retrofit & NCMR woCode) Custom -ID Refrigeration:Warm Gas Defrost Warm Gas Defrost (New Construction wCode) Custom -ID Warm Gas Defrost (Retrofit & NCMR woCode) Custom -ID ~easure Category : Electronk:s Office Equipment:Network PC Power Management Software Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential C ustom engineering for industrial and large commercial 11/13/2014 C ustom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential Custom engineering for industrial and large commercial 11/13/2014 Custom engineering for industrial and large commercial 11/13/2014 Non-Residential Report Date: 04/27/2015 Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation Page 38 of 55 Rocky Mountain Pov.<er Attachment 2 Page 95 of 112 Case No. PAC·E·16-14 Gross incremental annual electric savings (kWh/yr) Savings unit configuration Savings vary by install Site-specific confiouration Savings vary by install Site-specific confiouration Savings vary by install Site-specific confinuration Savings vary by install Site-specific confiouration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confinuration Savings vary by install Site-specific confiouration Savings vary by install Site-specific confinuration Savings vary by install Site-specific confiouration Savings vary by install Site-specific confiouration Savings vary by install Site-specific confinuration Savings vary by install Site-specific confiouration Savings vary by install Site-specific confinuration Savings vary by install Site-specific confiouration Program : wattsmart Business --. --" . --... -.. ~etwork PC Power Management Software -ID Office Equipment:Smart Plug Strip !Smart Plug Strip -ID ~easure Category : Farm & Dairy Engine Block Timers:Agricultural engine block heater timer gricultural engine block heater timer (New Construction) -ID gricultural engine block heater timer (Retrofit) -ID Fans:Circulating fan ~irculating fan: 12-23" diameter (New Construction) -ID ~irculating fan: 12-23" diameter (Retrofit) -ID Circulating fan: 24-35" diameter (New Construction) -ID Circulating fan: 24-35" diameter (Retrofit) -ID Circulating fan: 36-47" diameter (New Construction) -ID Circulating fan: 36-47" diameter (Retrofit) -ID Circulating fan: >=48" diameter (New Construction) -ID Circulating fan: >=48" diameter (Retrofit) -ID Fans:Controfler rogrammable ventilation controller (New Construction) -ID rogrammable ventilation controller (Retrofit) -ID Fans:High-efficiency ventilation system High-efficiency ventilation system: 12-23" diameter (New Construction) - D High-efficiency ventilation system: 12-23" diameter (Retrofit) -ID High-efficiency ventilation system: 24-35" diameter (New Construction) - D High-efficiency ventilation system: 24-35" diameter (Retrofit) -ID High-efficiency ventilation system: 36-47" diameter (New Construction) - D High-efficiency ventilation system: 36-47" diameter (Retrofit) -iD High-efficiency ventilation system: >=48" diameter (New Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date ., " -,-,. ,.,.- ~omputer network Power Management Software 11/13/2014 Non-Residential Any plug strip that eliminates idle or stand-by polwer onsumption of connected pulg-lead appliance through the use 11/13/2014 of an occupancy sensor, electric load sensor, or timer. Non-Residential Agriculture imer for cycling agricultural engine block heater 11/13/2014 imer for cycling agricultural engine block heater 11/13/2014 Non-Residential Agriculture Circulation fan, small (12-23" diameter) 11/13/2014 Circulation fan, small (12-23" diameter) 11/13/2014 Circulation fan, medium (24-35" diameter) 11/13/2014 Circulation fan, medium (24-35" diameter) 11/13/2014 Circulation fan. large (36-47" diameter) 11/13/2014 Circulation fan, large (36-47" diameter) 11/13/2014 ~irculation fan. extra large (>=48" diameter) 11/13/2014 ~irculation fan, extra large (>=48" diameter) 11/13/2014 Non-Residential Agriculture ontroller for automatic switching of ventilation fans 11/13/2014 ontroller for automatic switching of ventilation fans 11/13/2014 Non-Residential Agriculture r,Jentilation fan, small (12-23" diameter) 11/13/2014 r,Jentilation fan, small (12-23" diameter) 11/13/2014 r,lentilation fan. medium (24-35" diameter) 11/13/2014 ~entilation fan. medium (24-35" diameter) 11/13/2014 r,Jentilation fan. large (36-47" diameter) 11/13/2014 r,Jentilation fan. large (36-47" diameter) 11/13/2014 r,Jentilation fan, extra large (>=48" diameter) 11/13/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 39 of 55 Rocky Mountain Power Attachment 2 Page 96 ol 112 Case No. PAC-E.1&14 Gross incremental annual Savings unit electric savings (kWh/yr) -,, 103 Measure 100 Measure 512 Measure 512 Measure 419 Measure 419 Measure 486 Measure 486 Measure 557 Measure 557 Measure 1,460 Measure 1,460 Measure 1,020 Measure 1,020 Measure 419 Measure 419 Measure 750 Measure 750 Measure 1,500 Measure 1,500 Measure 3,000 Measure Program : wattsmart Business I ,. ~·. ,, .. ~onstruction) -ID High-efficiency ventilation system: >=48" diameter (Retrofit) -ID Fans:Variable Frequency Drive otato or onion storage fan VFD -ID Livestock Waterers:High-efficiency livestock waterer High efficiency livestock waterer (New Construction) -ID High efficiency livestock waterer (Retrofit) -ID Milkers:Milker Take Off ~utomatic milker takeoffs (retrofit only) -ID Pumps:Variable Frequency Drives ariable frequency drive for dairy vacuum pump (retrofit only) -ID Refrigeration:Milk pre-cooler Milk pre-cooler (New Construction) -ID Milk pre-cooler (Retrofit) -ID Water Heating:Heat reclaimer Heat recovery (New Construction)-ID Heat recovery (Retrofit) -ID •easure Category : Food Service Equipment Cooking Equipment:Fryer Electric Commercial Fryer: Tier 1 -ID Electric Commercial Fryer: Tier 2 -ID Cooking Equipment:Griddle :Electric Griddle: Tier 2 -ID Cooking Equipment:Oven :Electric Combination Oven: (16-20 pans)-ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 I ~entilation fan, extra large (>=48" diameter) Non-Residential Agriculture dd variable frequency drive to existing or new fan in potato or nion stora e. Non-Residential Agriculture High efficiency livestock waterer High efficiency livestock waterer Non-Residential Agriculture ~utomatic milker takeoff Non-Residential Agriculture ariable frequency drive for dairy vacuum pump (retrofit only) Non-Residential Agriculture Precool milk with well water prior to refrigeration Drecool milk with well water prior to refrigeration Non-Residential Agriculture Reclaim heat from refrigeration condenser to heat water Reclaim heat from refrigeration condenser to heat water Non-Residential High Efficiency Energy Star qualified Commercial Fryer Electric Onlvl High Efficiency Energy Star qualified Electric Commercial Frye1 with a Heavy Load Efficiency >= 85% and Idle Energy Rate <= 860W. Non-Residential igh Efficiency Energy Star Tier 2 qualified Electric Griddle Non-Residential ;High efficiency Electric Combination Oven with Heavy Load ,Efficienc Effective Date 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 Report Date : 04/27/2015 Energy Savings Calculation method RMP Deemed RMP Calculation RMP Deemed RMP Deemed RMP Deemed I RMP Deemed I RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Deemed RMP Deemed RMP Deemed RTF Deemed Page 40 of 55 Rocky Mountain Power Attachment 2 Page 97 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 3,000 Measure Savings vary by install Site-specific confi uration 1,209 Measure 1,209 Measure 992 Measure 2,505 Hp Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration 1,689 Measure 2,881 Measure 2,595 Measure 12,945 Measure 'Program : wattsmart Business !Electric Combination Oven: (6-15 pans) -ID lectric Convection Oven: Full Size -ID ;Electric Convection Oven: Half Size -ID Cooking Equipment:Steam Cooker :Electric Steam Cooker: 3-, 4-. 5-and 6-pan sizes -Tier 1 -ID Electric Steam Cooker: 3-, 4-, 5-and 6-pan sizes -Tier 2 -ID Dishwashers:Commercial Dishwasher ~ommercial Dishwasher (Electric DHW): Multiple Tank Conveyor -ID ~ommercial Dishwasher (Electric DHW): Single Tank Conveyor -ID ~ommercial Dishwasher (Electric DHW): Stationary Rack, Single Tank, Poor Type -ID ~ommercial Dishwasher (Electric DHW): Undercounter -ID ~ommercial Dishwasher (Gas DHW): Multiple Tank Conveyor -ID Commercial Dishwasher (Gas DHW): Single Tank Conveyor -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 ;High efficiency Electric Combination Oven with Heavy Load :Efficienc igh Efficiency Electric Convection Oven IHigh Efficiency Electric Convection Oven Non-Residential High Efficiency Energy Star qualified Electric Steam Cooker ith a Cooking Efficiency>= 50% IHigh Efficiency Energy Star qualified Electric Steam Cooker ith a Cooking Efficiency >=68% Non-Residential High Efficiency Commercial Energy Star qualified high emperature Multiple Tank Conveyor Dishwasher with electric booster usina electicallv heated domestic water High Efficiency Commercial Energy Star qualified high emperature Single Tank Conveyor Dishwasher with electric booster usina electicallv heated domestic water High Efficiency Commercial Energy Star qualified high emperature Stationary Rack, Single Tank, Door Type Dishwasher with electric booster using electically heated domestic water High Efficiency Commercial Energy Star qualified high ~emperature Undercounter Dishwasher with electric booster usina electicallv heated domestic water High Efficiency Commercial Energy Star qualified high emperature Multiple Tank Conveyor Dishwasher with electric nooster usina aas heated domestic water High Efficiency Commercial Energy Star qualified high ~emperature Single Tank Conveyor Dishwasher with electric booster usina oas heated domestic water High Efficiency Commercial Energy Star qualified high Effective Date 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 Commercial Dishwasher (Gas DHW): Stationary Rack, Single Tank, Door •emperature Stationary Rack, Single Tank, Door Type 11/13/2014 lfype -ID Commercial Dishwasher (Gas DHW): Undercounter -ID Freezers:Commercial Freezer ommercial Transparent Door Freezer: 0 < V < 15 -ID ommercial Transparent Door Freezer: 15 <= V < 30 -ID Dishwasher with electric booster using gas heated domestic water High Efficiency Commercial Energy Star qualified high ~emperature Undercounter Dishwasher with electric booster usina electicallv heated domestic water Non-Residential igh Efficiency Energy Star qualified Commercial Transparent oor Freezer with Interior volume equal to (0 < V < 15 cubic eet igh Efficiency Energy Star qualified Commercial Transparent oor Freezer with an interior volume equal Report Date : 04/27/2015 11/13/2014 11/13/2014 11/13/2014 Energy Savings Calculation method RTF Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 41 of 55 Rocky Mountain Power Attachment 2 Page 98 of 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) Savings unit 17,665 Measure 3,020 Measure 3,059 Measure 18,769 Measure 39,312 Measure 27,408 Measure 9,212 Measure 11 ,863 Measure 3,171 Measure 11 ,230 Measure 4,948 Measure 4,840 Measure 2,089 Measure 396 Measure 947 Measure Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Program : wattsmart Business - - - Commercial Transparent Door Freezer: 30 <= V < 50 -ID Commercial Transparent Door Freezer: 50 <= V -ID t ommercial Transparent Door Freezer: Horizontal -ID Grocery Refrigeration:Refrigeration Controls nti-Sweat Heater Controls -Low Temp -ID nti-Sweat Heater Controls -Med Temp -ID Holding Cabinet:lnsulated Holding Cabinet Electric Insulated Holding Cabinet: 13 <= V < 28 cu. ft. -ID Electric Insulated Holding Cabinet: < 13 cu. ft. -ID Electric Insulated Holding Cabinet: >= 28 cu. Ft. -ID Ice Machine:lce Machine Ice Machines (Air-Cooled Only): Tier 1: Harvest Rate < 500 lbs/day -ID Ice Machines (Air-Cooled Only): Tier 1: Harvest Rate >= 500 lbs/day -ID Ice Machines (Air-Cooled Only): Tier 2: Harvest Rate < 500 lbs/day -ID Ice Machines (Air-Cooled Only): Tier 2: Harvest Rate >= 500 lbs/day -ID Lighting:Refrigerated Case Lighting ED Case Lighting (Retrofit Only) -ID efrigerated Case Occupancy Sensor (Retrofit Only) -ID Refrigerators:Commercial Refrigerator Commercial Transparent Door Refrigerator: 0 < V < 15 -ID Commercial Transparent Door Refrigerator: 15 <= V < 30 -ID "'"""" o (15 <= V < 30 cubic feet) High Efficiency Energy Star qualified Commercial Transparent Door Freezer with an interior volume equal to (30 <= V < 50 :ubic feet) High Efficiency Energy Star qualified Commercial Transparent Door Freezer with an interior volume equal to (50 <= V cubic eetl High Efficiency Energy Star qualified Commercial Transparent Door Freezer /Horizontal) Non-Residential nti-Sweat Heater Controls-RTF-Low Temp nti-Sweat Heater Controls-RTF-Med Temp Non-Residential High Efficiency Energy Star qualified 3/4 Size Electric Insulated Holding Cabinet with internal volume of 13 <= V < 28 cubic feel High Efficiency Energy Star qualified Electric Insulated Holding ~abinet with internal volume of< 13 cubic feet High Efficiency Energy Star qualified Full Size Electric nsulated Holding Cabinet with internal volume of >= 28 cubic 'eet Non-Residential High Efficiency Energy Star qualified Ice Machine with an ice harvest rate of less than 500 lbs ner dav High Efficiency Energy Star qualified Ice Machine with a ice harvest rate of eoual to or nreater than 500 lbs/ dav High Efficiency CEE Tier 2 qualified Ice Machine with an Ice harvest rate less than 500 lbs/dav High Efficiency CEE Tier 2 qualified Ice Machine with an Ice harvest rate of eaual to or areater than 500 lbs/dav Non-Residential ED replacing flourescent lamp in refrigerated cases. ccupancy Sensor installed in existing refrigerated case with ED liqhtin Non-Residential High Efficiency Energy Star qualified Commercial Transparent Door Refrigerator with Interior volume equal to (0 < V < 15 ubic feet\ High Efficiency Energy Star qualified Commercial Transparent b oor Refriaerator with an interior Report Date : 04/27/2015 Effective Date 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RTF Deemed RTF Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 42 of 55 Rocky Mountain Power Attachment 2 Page 99 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 1,504 Measure 2,393 Measure 1,978 Measure 378.4 Linear ft. 232.8 Linear ft. 2,770 Measure 658 Measure 5,624 Measure 748 Measure 2,410 Measure 1,355 Measure 3,876 Measure 96 Linear ft. 18.8 Linear ft. 883 Measure 856 Measure Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Program : wattsmart Buslne" -volume=15 <= V < 30 cubic feet High Efficiency Energy Star qualified Commercial Transparent Commercial Transparent Door Refrigerator: 30 <= V < 50 -ID Door Refrigerator with an interior volume=30 <= V < 50 cubic eel High Efficiency Energy Star qualified Commercial Transparent Commercial Transparent Door Refrigerator: 50 <= V -ID Door Refrigerator with an interior volume=50 <= V interior ubic feet Commercial Transparent Door Refrigerator: Horizontal -ID -iigh Efficiency Energy Star qualified Horizontal Configuration Commercial Transoarent Door Refriaerator Refrigerators:Residential Refrigerator CEE Tier 3 Non-Residential efrigerator -CEE Tier 3 -Any Style (residential used in a business) -ID !Energy efficient refrigerator Ventifation:Kitchen Ventilation emand Controlled Kitchen Ventilation -ID ~easure Category : HVAC Controls and Thermostats:Contro/fer ·ccupancy Based PTHP/PTAC control -ID Non-Residential emand Controlled Kitchen Ventilation Non-Residential ccupancy based PTHP/PTAC control, all sizes with no prior ccupancy based control, retrofit onl Controls and Thermostats:Thermostat Non-Residential 65/366 day Programmable Thermostat or Occupancy-based Thermostat-~65 day Programmable Thermosat 110 Coofing:Chiffer Non-Residential hillers-10 High Efficiency Chiller Coofing:Evaporative Cooler Non-Residential Evaporative Cooling -ID Indirect or Direct Evaporative Cooling Use of evaporative cooling to pre-cool the air passing over a :vaporative Pre-Cooler -Retrofit -ID ondensing coil included as part of building cooling system. ~or single air-cooled packaged rooftop or matched split system ondensers onlv. Indirect-Direct Evaporative Cooling (IDEC) -ID Indirect-direct Evaporative cooling Coofing:Package Terminal Air Conditioners (PTAC) Non-Residential PTAC: <= 8,000 Btu/hr: Single package -ID High efficiency package terminal air conditioners <= 8,000 Btu/hr Sinole oackaoe PTAC: > 13,500 Btu/hr: Single package -ID High efficiency package terminal air conditioners > 13,500 Btu/hr Sinale oackaae Report Date : 04/27/2015 Effective Date 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/201 4 11/13/2014 11/13/2014 11/13/2014 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RTF Deemed RMP Calculation RMP Deemed RMP Deemed RMP Calculation RMP Deemed RMP Deemed RMP Calculation RMP Deemed RMP Deemed Page 43 of 55 Rocky Mountain Pov.,,er Attachment 2 Page 100 of 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) 993 1,394 412 85.8 Savings vary by install configuration 446 1,310 Savings vary by install configuration 0.39 202 Savings vary by install confiauration 21 27 Savings unit Measure Measure Measure Measure Measure Measure Measure Site-specific Cfm Ton Site-specific Ton Ton Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04127/2015 Effective Date Program : wattsmart Business -~ ' ~· -- bTAC: > 8,000 Btu/hr and< 10,500 Btu/hr: Single package -ID High efficiency package terminal air conditioners > 8,000 11/13/2014 Btu/hr and < 10 500 Btu/h Sinale oackaae bTAC: >= 10,500 Btu/hr and <= 13,500 Btu/hr: Single package -ID High efficiency package terminal air conditioners >-10,500 11/13/2014 Rtu/hr and< 13 500 Btu/hr Sinale nackane Cooling:Unitary Commercial Air Conditioners, Air-Cooled Non-Residential Unitary CAC (Air): < 65, 000 Btu/hr (single phase): Single Package -CEE CEE Tier 1, High Efficiency Air Conditioner Air Cooled < 11/13/2014 lrier 1 -ID 35 000 Btu/hr sinale oackaae '1nitary CAC (Air): < 65, 000 Btu/hr (single phase): Single Package -CEE JEE Tier 2, High Efficiency Air Conditioner Air Cooled < 11/13/2014 ITier 2 -ID 35 000 Btu/hr sinale oackaae Unitary CAC (Air): < 65, 000 Btu/hr (single phase): Split System -CEE JEE Tier 1, High Efficiency Air Conditioner Air Cooled < 11/13/2014 !Tier 1 -ID 35 000 Btu/hr solit svstem Unitary CAC (Air): < 65, 000 Btu/hr (single phase): Split System -CEE JEE Tier 2, High Efficiency Air Conditioner Air Cooled < 11/13/2014 Tier 2 -ID 35 000 Btu/hr solit svstem Unitary CAC (Air): All equipment sizes (three phase): Single Package -EE Tier 1, High Efficiency Air Conditioner Air Cooled, All 11/13/2014 CEE Tier 1 -ID aauioment sizes sinale oackaae Unitary CAC (Air): All equipment sizes (three phase): Single Package -JEE Tier 2, High Efficiency Air Conditioner Air Cooled, All 11/13/2014 CEE Tier 2 -ID aauioment sizes sinale oackaae Unitary CAC (Air): All equipment sizes (three phase): Split System -CEE JEE Tier 1, High Efficiency Air Conditioner Air Cooled, All 11/13/2014 !Tier 1 -ID aauioment sizes solit svstem '1nitary CAC (Air): All equipment sizes (three phase): Split System -CEE JEE Tier 2, High Efficiency Air Conditioner Air Cooled, All 11/13/2014 ITier 2 -ID eauioment sizes solit svstem Cooling:Unitary Commercial Air Conditioners, Water and Non-Residential Unitary CAC (Water): All equipment sizes: Single Package -CEE Tier 1 -High Efficiency Air Conditioner Water and Evaporatively 11/13/2014 ID Cooled Sinale Packaae Unitary CAC (Water): All equipment sizes: Split System -CEE Tier 1 -ID High Efficiency Air Conditioner Water and Evaporatively "ooled Snlit Svstem 11/13/2014 Heat Pump:Heat Pump -Ground Source Non-Residential HP -Ground (Heating & Cooling Mode): Closed Loop -ID Ground Source Heat Pump Loop (closed loop) 11/13/2014 HP -Ground (Heating & Cooling Mode): Heat Pump, Ground Source -ID High Efficiency heat pumps (Ground source or groundwater) 11/13/2014 HP -Ground (Heating & Cooling Mode): Open Loop -ID Groundwater Source Heat Pump Loop (open loop) 11/13/2014 Heat Pump:Heat Pump -Packaged Terminal Non-Residential iDTHP (Heating & Cooling Mode): <= 8,000 Btu/hr: Single package -ID High Efficiency package terminal heat pumps <-8,000 Btu/hr Sinale oackaae 11/13/2014 bTHP (Heating & Cooling Mode): > 13,500 Btu/hr: Single package -ID High Efficiency package terminal heat pumps > 13,500 11/13/2014 Rtu/hr Sinale nackaae PTHP (Heating & Cooling Mode):> 8,000 Btu/hr and< 10,500 Btu/hr: High Efficiency package terminal heat pumps> 8,000 Btu/hr 11/13/2014 "innle nackaae -ID land< 10 500 Btu/hr Sinale oackaae bTHP (Heating & Cooling Mode):>= 10,500 Btu/hr and<= 13,500 Btu/hr: High Efficiency package terminal heat pumps>-10,500 Btu/hr ~inale oackaae -ID And< 13 500 Btu/hr Sinale oackane 11/13/2014 Heat Pump:Heat Pumps -Air-Cooled Non-Residential Report Date : 04127/2015 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Deemed RMP Calculation RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed Page 44 af 55 Rocky Mountain Po'Ner Attachment 2 Page 101 of 112 Case No. PAC-E.16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 45 Ton 28 Ton Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confinuration 73 Ton Savings vary by install Site-specific confiauration 589 Ton 298 Ton 325 Ton 293 Ton 159 Ton Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 'Program : wattsmart Business .. HP -Air (Heating & Cooling Mode): < 65, 000 Btu/hr (single phase): Single Packaae -GEE Tier 1 -ID HP -Air (Heating & Cooling Mode):< 65, 000 Btu/hr (single phase): Single Packaae -GEE Tier 2 -ID HP -Air (Heating & Cooling Mode): < 65, 000 Btu/hr (single phase): Split Svstem -GEE Tier 1 -ID HP -Air (Heating & Cooling Mode):< 65, 000 Btu/hr (single phase): Split Svstem -GEE Tier 2 -ID HP -Air (Heating & Cooling Mode):< 65, 000 Btu/hr (three phase): Single Packaae -GEE Tier 1 -ID HP -Air (Heating & Cooling Mode):< 65, 000 Btu/hr (three phase): Single Packaae -GEE Tier 2 -ID HP -Air (Heating & Cooling Mode):< 65, 000 Btu/hr (three phase): Split Svstem -GEE Tier 1 -ID HP -Air (Heating & Cooling Mode):< 65, 000 Btu/hr (three phase): Split ~vstem -GEE Tier 2 -ID HP -Air (Heating & Cooling Mode): >= 65,000 Btu/hr (three phase): Single Package -17°F db/15°F wb outdoor air -GEE Tier 1 -ID HP -Air (Heating & Cooling Mode): >= 65,000 Btu/hr (three phase): Single Package -47°F db/43°F wb outdoor air -GEE Tier 1 -ID HP -Air (Heating & Cooling Mode): >= 65,000 Btu/hr (three phase): Split ~ystem -17°F db/15°F wb outdoor air -GEE Tier 1 -ID HP -Air (Heating & Cooling Mode):>= 65,000 Btu/hr (three phase): Split System -47°F db/43°F wb outdoor air -GEE Tier 1 -ID Heat Pump:Heat Pumps -VRF Air-Cooled RF Air-Cooled Heat Pump (Heating & Cooling Mode): GEE Tier 1 -ID Heat Pump:Heat Pumps -VRF Water-Cooled RF Water-Cooled Heat Pump (Heating & Cooling Mode): < 135,000 tu/hr -GEE Tier 1 -ID Heat Pump:Heat Pumps -Water-Source P -Water (Heating and Cooling Mode):< 135,000 Btu/hr: CEE Tier 1 - D Motors:Variable-Frequency Drives (HVAC fans and pumps) Wariable-Frequency Drives (HVAC fans and pumps):<= 100 horsepower: HVAC fans -ID f.lariable-Frequency Drives (HVAC fans and pumps):<= 100 horsepower: HVAC numns -ID GEE Tier 1, High Efficiency Single Package heat pump air coled < 65 000 Btu/hr sinale ohase ~EE Tier 2, High Efficiency Single Package heat pump air coaled < 65 000 Btu/hr sinale ohase EE Tier 1, High Efficiency Split System heat pump air cooled < 65 000 Btu/hr sinale ohase GEE Tier 2, High Efficiency Split System heat pump air cooled < 65 000 Btu/hr sinale ohase GEE Tier 1, High Efficiency Single Package heat pump air oaled < 65 000 Btu/hr three ohase EE Tier 2, High Efficiency Single Package heat pump air cooled < 65 000 Btu/hr three ohase EE Tier 1, High Efficiency Split System heat pump air cooled < 65 000 Btu/hr three ohase GEE Tier 2, High Efficiency Split System heat pump air cooled < 65 000 Btu/hr three ohase CEE Tier 1, High Efficiency Single Package heat pump air cooled >= 65,000 Btu/hr and : 17°F db/15°F wb outdoor air hree ohase ~EE Tier 1, High Efficiency Single Package heat pump air coled>= 65,000 Btu/hr and: 47F db/1 5F wb outdoor air three )hase ~EE Tier 1, High Efficiency Split System heat pump air cooled >= 65,000 Btu/hr and : 17°F db/15°F wb outdoor air three )hase EE Tier 1, High Efficiency Split System heat pump air cooled >= 65,000 Btu/hr and : 47F db/15F wb outdoor air three phase Non-Residential EE Tier 1, High Efficiency variable refrigerant flow heat pump ir cooled Non-Residential EE Tier 1, High Efficiency variable refrigerant flow heat pump atercooled Non-Residential EE Tier 1 High Efficiency water source heat pumps Non-Residential fJariable Frequency Drive controlling an HVAC applied fan Variable Frequency Drive controlling an HVAC applied pump Report Date : 04/27/2015 Effective Date 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Deemed RMP Deemed Page 45 of 55 Rocky Mountain Power Attachment 2 Page 102 of 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install canfiauration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install configuration Savings vary by install configuration Savings vary by install con figuration Savings vary by install configuration Savings vary by install configuration Savings vary by install configuration Savings vary by install confiauration 1,184 919 Savings unit .. - Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Hp Hp 1Program : wattsmart Business ~easure Category : Irrigation Water Distribution Equipment:Center Pivot Equipment prinkler Pressure Regulator Package (Custom)· ID Measure Category : Lighting Controls:Advanced Daylighting Control dvanced Daylighting Control · Retrofit -ID Controls:Custom eneral Illumination Lighting Control -Retrofit -Custom -ID Controls:Daylighting Control aylighing Control -Retrofit -ID Controls:Exterior Lighting Control :Exterior Lighting Control -New Construction/Major Renovation -ID Controls:Occupancy Control ·ccupancy Control -Retrofit -Integral -ID ·ccupancy Control -Retrofit -PIR and Dual Tech -ID Controls:Occupancy Control eiling Occupancy Control -SBL -Retrofit -PIR and Dual Tech -ID all Occupancy Control -SBL -Retrofit -PIR and Dual Tech -ID Exterior Lighting:CFL FL Wall Pack -New Construction/Major Renovation -ID Exterior Lighting:Custom xterior General llluminance Lighting -New Construction/Major [Renovation -Custom -ID Exterior Lighting:lnduction Fixture nduction Fixture -New Construction/Major Renovation -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Non-Residential ew pivot or linear pressure regulators replacing worn ressure regulators. Non-Residential ust incorporate both an occupancy sensor and daylighting ensor operating as part of the same control sequence in the Non-Residential ustom General Illumination Lighting Control, control not listed n tariff incentive tables Non-Residential ust control interior fixtures with driver or qualifying ballast that ims 50% or more of the fixture in response to daylight. Non-Residential ,ccupancy control which must control a linear fluorescent, nduction, or LED fixture. Non-Residential Integral Occupancy Sensor, integrated into lighting fixture IR, Dual Tech Non-Residential Small Business IR, Dual Tech IR, Dual Tech Non-Residential ew construction /major renovation exterior LED Wall pack Non-Residential ustom General Illumination Lighting, exterior fixture or lamp ot listed in tariff incentive tables Non-Residential ew construction/major renovation exterior induction fixture Effective Date 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 Report Date : 04/27/2015 I Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Deemed RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Deemed RMP Calculation RMP Deemed Page 46 of 55 I I I Rocky Mountain Power Attachment 2 Page 103 of 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) Savings vary by install configuration Savings vary by install configuration Savings vary by install configuration Savings vary by install configuration 342 Savings vary by install confi uration Savings vary by install configuration Savings vary by install confi uration Savings vary by install confi uration 548 Savings vary by install configuration 657 Savings unit Site-specific I Site-specific I Site-specific I Site-specific Measure Site-specific Site-specific Site-specific Site-specific Measure Site-specific Measure Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Program : wattsmart Business ----Exterior Lighting:LED Non-Residential ED Canopy/Soffit Fixture -New Construction/Major Renovation -ID New construction/major renovation exterior LED Canopy/Soffit 1xture ~ED Flood Light Fixture -< 100 W -New Construction/Major Renovation -New construction/major renovation exterior LED Flood Light ID 1xture < 100 W ED Flood Light Fixture ->= 100 W -New Construction/Major Renovation New construction/major renovation exterior LED Flood Light ID 1xture > 100W ED Outdoor Pole/Roadway Decorative Fixture -< 75 W -New New construction/major renovation exterior LED Outdoor Construction/Maier Renovation -ID bole/Roadwav decorative fixture ED Outdoor Pole/Roadway Fixture -<= 200 W -New Construction/Major New construction/major renovation exterior LED Outdoor Area Renovation -ID and Roadwav fixture < 200W ED Outdoor Pole/Roadway Fixture -> 200 W -New Construction/Major New construction/major renovation exterior LED Outdoor Area Renovation -ID and Roadwav fixture > 200 W ED Wall Pack Fixture -< 50 W -New Construction/Major Renovation -ID New construction/major renovation exterior LED Wall Pack "ixture < 50 W LED Wall Pack Fixture ->= 50 W -New Construction/Major Renovation -New construction/major renovation exterior LED Wall Pack ID "ixture > 50 W General 11/uminance:Ceramic Metal Halide (CMH) eramic Metal Halide (CHM) Fixture -Retrofit -ID General 11/uminance:CFL ompact Fluorescent Lamp (CFL) -Retrofit -Hardwired Fixture -ID General 11/uminance:Cold Cathode old Cathode Lamp -Retrofit -Screw-in Lamp -ID General 11/uminance:lnduction Induction Fixture -Retrofit -New Fixture Only -ID General 11/uminance:LED LED Lamp -Retrofit -Integral Screw-in -ID ED Fixture -Retrofit -Other LED -ID L ED Fixture -Retrofit -Recessed Downlight -ID General 11/uminance:LED ED Fixture -Retrofit -SBL -Recessed Downlight -ID General 11/uminance:Non-eligible fixture on-eligible fixture -Retrofit -ID Non-Residential eramic Metal Halide Fixture, all wattages Non-Residential ompact Fluorescent fixture, hardwire fixtures only, all attaoes. Non-Residential old cathode screw in lamp, all wattages Non-Residential nduction Fixture, all wattages, new fixtures only Non-Residential Integral Screw-in LED Lamp, LED must be on qualified eauioment list ED Fixture (excluding Recessed Downlight and integral screw-in). LED must be on aualified eauioment list Recessed Downlight LED Fixture, LED must be on qualified eauioment list Non-Residential Small Business ust replace existing incandescent or fluorescent, LED must e listed on qualified equipment list Non-Residential ny installed fixture not eligible for incentives. but that Report Date : 04/27/2015 Effective Date 11/13/2014 11 /13/2014 11 /13/2014 11 /13/2014 11 /13/2014 11 /13/2014 11 /13/2014 11 /13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 Energy Savings Calculation method RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Deemed RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation Page47of55 Rocky Mountain Power Attachment 2 Page 104 ol 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) 460 679 1,183 460 1,095 3,285 460 657 Savings vary by install configuration Savings vary by install configuration Savings vary by install configuration Savings vary by install configuration Savings vary by install confiouration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install configuration Savings vary by install Savings unit Measure Measure Measure Measure Measure Measure Measure Measure Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Program : wattsmart Business --- General 11/uminance:Pulse Start Metal Halide (PSMH) Pulse Start Metal Halide (PSMH) -Retrofit -Electronic Ballast -ID Pulse Start Metal Halide (PSMH) -Retrofit -Fixture -ID General ll/uminance:T5 Fluorescent T5 Fluorescent Lamp -Retrofit -Continuous Operation -ID T5 Fluorescent Lamp -Retrofit -High Bay -< 6 lamp fixture -ID T5 Fluorescent Lamp -Retrofit -High Bay ->= 6 lamp fixture -ID T5 Fluorescent Lamp -Retrofit -Relamp -ID T5 Fluorescent Lamp -Retrofit -Standard -ID General 11/uminance:TS Fluorescent T5 Fluorescent Fixture -Retrofit -SBL -High Bay -< 6 lamp fixture -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date ;,·,-;·, ., .~ Fontributes to reported project savings. Non-Residential Pulse Start Metal Halide Ballast. must be used in place of or 11/13/2014 eolace a maanetic ballast Pulse Start Metal Halide Fixture, wattages > 500 W 11/13/2014 Non-Residential W Nominal High Output Lamp installed in a continuous 11/13/2014 boeration aoolication Fixture with less than six (6) lamps: 4' T5HO lamp. Must 11/13/2014 eolace T12HONHO Incandescent or HID Fixture with six (6) or more lamps: 4' T5HO lamp. Must replace 11/13/2014 tT12HONHO Incandescent or HID ~amp wattage reduction >= 3 Watts, No ballast retrofit 11/13/2014 14' Nominal Lamp<= 28 Watts, Ballast Factor <= 1.0 11/13/2014 Non-Residential Small Business Fixture with less than six (6) lamps: 4' T5HO lamp. Must 11/13/2014 eolace T12HONHO Incandescent or HID T5 Fluorescent Fixture -Retrofit -SBL -High Bay ->= 6 lamp fixture -ID IJ:ixture with six (6) or more lamps: 4' T5HO lamp. Must replace 11/13/2014 rT12HONHO Incandescent or HID T5 Fluorescent Fixture -SBL -Retrofit -Standard -ID 14' Nominal Lamp <= 28 Watts, Ballast Factor <= 1.0 11/13/2014 T5 Fluorescent Lamp -SBL -Retrofit -Relamp -ID ~amp wattage reduction >= 3 Watts, No ballast retrofit 11/13/2014 General 11/uminance:TB Fluorescent Non-Residential T8 Fluorescent Lamp -Retrofit -CEE High Performance -ID 14' CEE Qualified High Performance Lamp and CEE Qualified 11/13/2014 Ballast included on aualified ballast list T8 Fluorescent Lamp -Retrofit -CEE Reduced Wattage -ID 14' CEE Qualified Reduced Wattage Lamp and CEE Qualified 11/13/2014 Ballast included on aualified ballast list 4' CEE Qualified Reduced Wattage or High Performance Lamp TB Fluorescent Lamp -Retrofit -Continuous Operation -ID ~nd CEE Qualified Ballast included on qualified list installed in 11/13/2014 a continuous ooeration aoolication. High bay fixture with less than six (6) lamps: 4' CEE Qualified TB Fluorescent Lamp -Retrofit -High Bay -< 6 lamp fixture -ID High Performance Lamp. Must replace T1 2HONHO, 11/13/2014 Incandescent or HID. l~igh bay fixture with six (6) or more lamps: 4' CEE Qualified T8 Fluorescent Lamp -Retrofit -High Bay - >= 6 lamp fixture -ID High Performance Lamp. Must replace T12HONHO, 11/13/2014 Incandescent or HID. TB Fluorescent Lamp -Retrofit -Premium -Delamp -ID ' CEE Qualified Reduced Wattage or High Performance Lamp 11/13/2014 nd CEE Qualified Ballast. Must remove one or Report Date: 04/27/2015 Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation Page48 of55 Rocky Mountain Po.....er Attachment 2 Page 105of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) configuration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiouration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiouration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiauration Savings vary by install Site-specific confiouration Savings vary by install Site-specific configuration Savings vary by install Site-specific configuration Savings vary by install Site-specific configuration Savings vary by install Site-specific confiouration -~ Program : wattsmart Business 8 Fluorescent Lamp -Retrofit -Relamp -ID General llluminance:TB Fluorescent T8 Fluorescent Fixture -SSL -Retrofit - 8' T12 Conversion -ID T8 Fluorescent Fixture -SBL -Retrofit -CEE Premium -ID fr8 Fluorescent Fixture -SSL -Retrofit -Delamp -ID fr8 Fluorescent Fixture -SSL -Retrofit -High Bay -< 6 lamp fixture -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date more lamps. To delamp an existing fixture, the lamp and all orresponding sockets must be permanently disabled. ,_amp wattage reduction >= 3 Watts, No ballast retrofit 11/13/2014 Non-Residential Small Business 8' T12 to (2) 4' CEE Qualified Reduced Wattage or High 11/13/2014 "erformance TS Lamos and CEE Qualified Ballast 4' CEE Qualified Reduced Wattage Lamp and CEE Qualified 11 /13/2014 3allast included on aualified ballast list 4' CEE Qualified Reduced Wattage or High Performance Lamp and CEE Qualified Ballast. Must remove one or more lamps. To delamp an existing fixture, the lamp and all corresponding 11 /13/2014 sockets must be permanently disabled. High bay fixture with less than six (6) lamps: 4' CEE Qualified High Performance Lamp. Must replace T12HONHO, 11 /13/2014 Incandescent or HID. trs Fluorescent Fixture -SSL -Retrofit -High Bay ->= 6 lamp fixture -ID High bay fixture with six (6) or more lamps: 4' CEE Qualified High Performance Lamp. Must replace T12HONHO, 11/13/2014 fr8 Fluorescent Lamp -SSL -Retrofit -Relamp -ID Lighting:lnterior Lighting [Interior Lighting and Lighting Control -NCMR -ID Lighting:Package Lighting Package Lighting NCMR -ID Package Lighting Retrofit -ID Non-General llluminance:Custom on General llluminance Lighting -Retrofit -Custom -ID Non-General 11/uminance:LED ,-ED Channel Letter Sign -Retrofit -ID ,_ED Exit Sign -Retrofit -ID ,-ED Marquee/Cabinet Sign -Retrofit -ID ,-ED Message Center Sign -Retrofit -ID ncandescent or HID. amp wattage reduction >= 3 Watts, No ballast retrofit Non-Residential ers prescriptive and/or custom incentives for qualifying iohting equipment Non-Residential uners prescriptive and/or custom incentives for qualifying iahtina eauioment Jtters prescriptive and/or custom incentives for qualifying iahtina eauioment Non-Residential ustom Non-General Illumination Lighting, fixture or lamp not isled in tariff incentive tables Non-Residential ED replacing existing neon or fluorescent lamps in a channel etter sian ED or photoluminecent exit sign replacing incandescent of nuorescent exit sian ED replacing existing nuorescent lighting in a marquee or abinet sian ED replacing existing incandescent lamps in a message Report Date : 04/27/2015 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 11/13/2014 Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Calculation RMP Deemed RMP Calculation RMP Deemed RMP Deemed Page 49 of 55 Rocky Mountain Po......er Attachment 2 Page 106 of 112 Case No. PAC-E.16-14 Gross incremental annual electric savings (kWh/yr) Savings vary by install confiauration Savings vary by install confiouration Savings vary by install confiauration Savings vary by install configuration Savings vary by install configuration Savings vary by install configuration Savings vary by install confiouration Savings vary by install configuration Savings vary by install confiauration Savings vary by install confiauration Savings vary by install configuration 17 Savings vary by install confiauration 21 47 Savings unit Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Site-specific Linear ft. Site-specific Linear ft. Measure Program : wattsmart Business Non-General 11/uminance:LED ED Exit Sign · SBL · Retrofit· ID ~easure Category : Motol'S Electronically Commutated Motor:Electronically Commutated Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date r:enter sign l Non-Residential Small Business us! replace existing incandescent or fluorescent 11/13/2014 Non-Residential Electronically Commutated Motor:< 1 horsepower: HVAC application -ID Electronically Commutated Motor (ECM) used in an HVAC 11/13/2014 :rnnlication Electronically Commutated Motor: < 1 horsepower: Refrigeration Electronically Commutated Motor (ECM) used in a refrigeration 11/13/2014 bnnlication -ID a12olication Green Motor Rewinds:Green Motor Rewinds (Agriculture) Non-Residential Agriculture 100 hp Green Motor Rewind for motor used in agriculture, Green Motor Rewinds (Agriculture): 100 hp -ID eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess Green Motor Rewinds (Agriculture): 1000 hp -ID 1000 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 rewind orocess Green Motor Rewinds (Agriculture): 125 hp -ID 125 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 1250 hp Green Motor Rewind for motor used in agriculture, Green Motor Rewinds (Agriculture): 1250 hp -ID eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 15 hp Green Motor Rewind for motor used in agriculture, Green Motor Rewinds (Agriculture): 15 hp -ID eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 150 hpGreen Motor Rewind for motor used in agriculture, Green Motor Rewinds (Agriculture): 150 hp -ID eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 1500 hp Green Motor Rewind for motor used in agriculture, Green Motor Rewinds (Agriculture): 1500 hp -ID eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 1750 hp Green Motor Rewind for motor used in agriculture, Green Motor Rewinds (Agriculture): 1750 hp -ID eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess ?O hp Green Motor Rewind for motor used in agriculture, Green Motor Rewinds (Agriculture): 20 hp -ID eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess ?00 hp Green Motor Rewind for motor used in agriculture, Green Motor Rewinds (Agriculture): 200 hp -ID eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess Report Date : 04/27/2015 Energy Savings Calculation method RMP Calculation RMP Deemed RMP Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed Page 50 of 55 Rocky Mountain Power Attachment 2 Page 107 of 112 Case No. PAC-E-11>14 Gross incremental annual electric savings (kWh/yr) Savings vary by install configuration 2,895 9.3 1,040 10,192 1,157 10,590 317 1,376 12,681 14,732 425 1,821 Savings unit Site-specific Hp Watt Measure Measure Measure Measure Measure Measure Measure Measure Measure Measure - Program : wattsmart Business .. , ,· .. ~· ' Green Motor Rewinds (Agriculture): 2000 hp -ID Green Motor Rewinds (Agriculture): 2250 hp -ID Green Motor Rewinds (Agriculture): 25 hp -ID Preen Motor Rewinds (Agriculture): 250 hp -ID preen Motor Rewinds (Agriculture): 2500 hp -ID Green Motor Rewinds (Agriculture): 30 hp -ID Green Motor Rewinds (Agriculture): 300 hp -ID Green Motor Rewinds (Agriculture): 3000 hp -ID Green Motor Rewinds (Agriculture): 350 hp -ID Green Motor Rewinds (Agriculture): 3500 hp -ID Green Motor Rewinds (Agriculture): 40 hp -ID Preen Motor Rewinds (Agriculture): 400 hp -ID preen Motor Rewinds (Agriculture): 4000 hp -ID Green Motor Rewinds (Agriculture): 450 hp -ID Green Motor Rewinds (Agriculture): 4500 hp -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date 12000 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 2250 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 125 hpGreen Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 250 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind process 12500 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 30 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 1300 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11 /13/2014 ewind process 13000 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind process 1350 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11 /13/2014 ewind orocess 3500 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11 /13/2014 ewind process f40 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind process 400 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11 /13/2014 ewind orocess 4000 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 450 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind process 4500 hp Green Motor Rewind for motor used in agriculture, 11/13/2014 eturnina motor to best oossible efficiencv Report Date : 04/27/2015 Energy Savings Calculation method RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed Page 51 of 55 Rocky Mountain Power Attachment 2 Page 108ol112 Case No. PAC-E-16--14 Gross incremental annual Savings unit electric savings (kWh/yr) - 16,766 Measure 18,744 Measure 595 Measure 2,823 Measure 20,783 Measure 640 Measure 3,370 Measure 24,784 Measure 3,929 Measure 28,854 Measure 746 Measure 4,456 Measure 32,976 Measure 5,003 Measure 37,021 Measure Program : wattsmart Business --- preen Motor Rewinds (Agriculture): 50 hp -ID K,reen Motor Rewinds {Agriculture): 500 hp -ID K,reen Motor Rewinds (Agriculture): 5000 hp -JD K,reen Motor Rewinds {Agriculture): 60 hp -ID Preen Motor Rewinds {Agriculture): 600 hp -ID Preen Motor Rewinds (Agriculture): 700 hp -ID K,reen Motor Rewinds {Agriculture): 75 hp -JD K,reen Motor Rewinds (Agriculture): 800 hp -ID K,reen Motor Rewinds (Agriculture): 900 hp -ID Green Motor Rewinds:Green Motor Rewinds (Industrial) Preen Motor Rewinds {Industrial): 100 hp -ID preen Motor Rewinds (Industrial): 1000 hp -ID Preen Motor Rewinds (Industrial): 125 hp-ID Preen Motor Rewinds (Industrial): 1250 hp -ID K,reen Motor Rewinds {Industrial): 15 hp -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date "' - using controlled rewind process 50 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 500 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 5000 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 60 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 600 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 700 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 5 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess 800 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind orocess ~00 hp Green Motor Rewind for motor used in agriculture, eturning motor to best possible efficiency using controlled 11/13/2014 ewind process Non-Residential Industrial 100 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind process 1000 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind process 125 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind process 1250 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind process 15 hp Green Motor Rewind for motor used in an industrial 11/13/2014 ~nnlication returnina motor to best Possible Report Date : 04/27/2015 Energy Savings Calculation method RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed Page 52 of 55 Rocky Mountain Po<Ner Attachment 2 Page 109 of 112 Case No. PAC-E.16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 802 Measure 5,567 Measure 41 ,049 Measure 765 Measure 6,193 Measure 7,195 Measure 788 Measure 8,205 Measure 9,211 Measure 2,005 Measure 24,172 Measure 2,598 Measure 29,973 Measure 601 Measure Program : wattsmart Business --- Green Motor Rewinds (Industrial}: 150 hp -ID Green Motor Rewinds (Industrial}: 1500 hp -ID Green Motor Rewinds (Industrial}: 1750 hp -ID Green Motor Rewinds {Industrial): 20 hp -ID Green Motor Rewinds (Industrial}: 200 hp -ID Green Motor Rewinds (Industrial}: 2000 hp -ID Green Motor Rewinds (Industrial}: 2250 hp -ID Green Motor Rewinds (Industrial): 25 hp -ID Green Motor Rewinds (Industrial): 250 hp -ID Green Motor Rewinds (Industrial): 2500 hp -ID Green Motor Rewinds (Industrial): 30 hp -ID Green Motor Rewinds (Industrial): 300 hp -ID Green Motor Rewinds (Industrial}: 3000 hp -ID Green Motor Rewinds (Industrial): 350 hp -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date -- efficiency using controlled rewind process 150 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind orocess 1500 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind orocess 1750 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind nrocess ,o hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind orocess 200 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ;ontrolled rewind orocess '000 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind nrocess '250 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind orocess 5 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind orocess 250 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ;ontrolled rewind orocess '500 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ;ontrolled rewind orocess 30 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind orocess 300 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind orocess 3000 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ;ontrolled rewind orocess 350 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind process Report Date : 04/27/2015 Energy Savings Calculation method RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed Page 53 of 55 Rocky Mountain Poy..,er Attachment 2 Page 110 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 3,089 Measure 35,891 Measure 41 ,697 Measure 804 Measure 4,088 Measure 47,454 Measure 53,051 Measure 1,052 Measure 4,972 Measure 58,823 Measure 1,133 Measure 5,935 Measure 70,147 Measure 6,919 Measure rrogram : ~attsmart Business Green Motor Rewinds (Industrial}: 3500 hp -ID breen Motor Rewinds (Industrial): 40 hp -ID Green Motor Rewinds (Industrial): 400 hp -ID Green Motor Rewinds (Industrial}: 4000 hp -ID Green Motor Rewinds (Industrial): 450 hp -ID breen Motor Rewinds (Industrial): 4500 hp -ID breen Motor Rewinds (Industrial): 50 hp -ID Green Motor Rewinds (Industrial): 500 hp -ID Green Motor Rewinds (Industrial): 5000 hp -ID Green Motor Rewinds (Industrial): 60 hp -ID Green Motor Rewinds (Industrial): 600 hp -ID b reen Motor Rewinds (Industrial): 700 hp -ID breen Motor Rewinds (Industrial): 75 hp -ID b reen Motor Rewinds (Industrial): 800 hp -ID Green Motor Rewinds (Industrial): 900 hp -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 Effective Date 3500 .. hp Gr~en ·Motor R~wind for motor used in an iniustrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind orocess 40 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 :ontrolled rewind orocess 400 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind nrocess 4000 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind orocess 1450 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind orocess 14500 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind orocess 50 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind orocess 500 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind orocess 5000 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind orocess 60 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind orocess pOO hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind orocess 00 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind orocess 5 hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 controlled rewind orocess BOO hp Green Motor Rewind for motor used in an industrial application, returning motor to best possible efficiency using 11/13/2014 ontrolled rewind crocess 900 hp Green Motor Rewind for motor used in an industrial 11/13/2014 ~nnlication returnina motor to best oossible Report Date : 04/27/2015 Energy Savings Calculation method RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed RTF Deemed Page 54 of 55 Rocky Mountain Power Attachment 2 Page 111 of 112 Case No. PAC-E-16-14 Gross incremental annual Savings unit electric savings (kWh/yr) 81,667 Measure 1,319 Measure 7,848 Measure 93,334 Measure 8,811 Measure 104,783 Measure 1,418 Measure 9,804 Measure 116,183 Measure 1,476 Measure 14,689 Measure 17,065 Measure 1,519 Measure 19,461 Measure 21 ,847 Measure Program : wattsmart Business Measure Category : Refrlgeratlqn Controls:Adaptive Refrigeration Controller daptive Refrigeration Controller (Retrofit) -ID Fast Acting Door:Fast Acting Door Fast Acting Door (Retrofit) -ID Measure Category : Wastewater Wastewater:Aeration !Extended Range Circulator (Retrofit) -ID Rocky Mountain Power Energy Efficiency Measures for Idaho Measures Effective on 04/27/2015 fficiency using controlled rewind process Non-Residential !Replace conventional controls with adaptive controls and. in ome instances, electric expansion valves. Non-Residential eplace manually operated door, automatic door with long ycle time, strip curtain, or entryway with no door with fast ctini:i dQor. Non-Residential ddress excess aeration with extended range circulator. Report Date : 04/27/2015 Effective Date 11/13/2014 11/13/2014 11/13/201 4 Energy Savings Calculation method RMP Calculation RMP Calculation RMP Calculation Page 55 of 55 Rocky Mountain Po'Ner Attachment 2 Page 112 of 112 Case No. PAC-E-16-14 Gross incremental annual electric savings (kWh/yr) Savings vary by install configuration Savings vary by install configuration Savings vary by install confii:iuration Savings unit Site-specific Site-specific Site-specific