HomeMy WebLinkAboutFinal Approved Schedule 84.pdf
January 25, 2007
Ms. Jean D. Jewell, Secretary
Idaho Public Utilities Commission
P. O. Box 83720
Boise, ID 83720-0074
RE: IPC-E-06-17
Amended Tariffs
Dear Ms. Jewell:
Please find enclosed for filing the amended Schedule 84 tariff sheets as prescribed in
IPUC Order NO. 30227.
Sincerely,
Bart Kline
Senior Attorney
BLK:sh
Enclosures
c: Ric Gale
P&RS Files
Legal Files
RECEIVED
2007 January 25 PM 1:44
IDAHO PUBLIC
UTILITIES COMMISSION
Idaho Power Company First Revised Sheet No. 84-1
Cancels
I.P.U.C. No. 28, Tariff No. 101 Original Sheet No. 84-1
IDAHO Issued by IDAHO POWER COMPANY
Issued per IPUC Order No. 30227 John R. Gale, Vice President, Regulatory Affairs
Effective - January 25, 2007 1221 West Idaho Street, Boise, Idaho
SCHEDULE 84
CUSTOMER ENERGY
PRODUCTION NET METERING
AVAILABILITY
Service under this schedule is available throughout the Company’s service territory within the
State of Idaho for Customers intending to operate as Sellers under this schedule to generate electricity to
reduce all or part of their monthly energy usage.
Service under this schedule is available on a first-come, first-served basis until the cumulative
generation nameplate capacity of net metering systems equals 2.9 MW, which represents one-tenth of
one percent of the Company’s retail peak demand during 2000. No single Seller may connect more
than 20 percent of the cumulative generation nameplate capacity connected under this schedule.
APPLICABILITY
Service under this schedule is applicable to any Seller that:
1. Owns and/or operates a Generation Facility fueled by solar, wind, biomass, or
hydropower, or represents fuel cell technology; and
2. Maintains its retail electric service account for the loads served at the Point of Delivery
adjacent to the Generation Interconnection Point as active and in good standing; and
3. Meets all applicable requirements of the Company’s Schedule 72 and Generation
Interconnection Process; and
4. Takes retail electric service under:
a. Schedule 1 or Schedule 7; and
Owns and/or operates a Generation Facility with a total nameplate capacity rating of 25
kW or smaller that is interconnected to the Seller’s individual electric system on the Seller’s side
of the Point of Delivery, thus all energy received and delivered by the Company is through the
existing watt-hour retail meter.
b. Schedules other than Schedule 1 or Schedule 7; and
Owns and/or operates a Generation Facility with a total nameplate capacity rating of 100
kW or smaller that is interconnected at a Generation Interconnection Point that is adjacent to the
Seller’s Point of Delivery and is metered at the same voltage through a meter that is separate
from the retail load metering at the Seller’s Point of Delivery.
IDAHO PUBLIC UTILITIES COMMISSION
Approved Effective
Feb. 8, 2007 Jan. 25, 2007
Per ON 30227
Jean D. Jewell Secretary
Idaho Power Company First Revised Sheet No. 84-2
Cancels
I.P.U.C. No. 28, Tariff No. 101 Original Sheet No. 84-2
IDAHO Issued by IDAHO POWER COMPANY
Issued per IPUC Order No. 30227 John R. Gale, Vice President, Regulatory Affairs
Effective - January 25, 2007 1221 West Idaho Street, Boise, Idaho
SCHEDULE 84
CUSTOMER ENERGY
PRODUCTION NET METERING
(Continued)
APPLICABILITY (Continued)
One-Meter Option: A separate meter from the existing retail load metering at the Seller’s
Point of Delivery is not required if:
1. The Generation Facility has a total nameplate capacity rating of 25 kW or
smaller; and
2. The Generation Facility has a total nameplate capacity rating no more
than 2% of the Seller’s Basic Load Capacity (BLC) or comparable average maximum
monthly Billing Demands.
A Seller who uses the One-Meter Option will not receive financial credit for any Excess
Net Energy during the Billing Period.
DEFINITIONS
Avoided Energy Cost is the monthly weighted average of the daily on-peak and off-peak Dow
Jones Mid-Columbia Electricity Price Index (Dow Jones Mid-C Index) prices for non-firm energy. This
rate is calculated based upon the previous calendar month’s data. If the Dow Jones Mid-C Index prices
are not reported for a particular day or days, the average of the immediately preceding and following
reporting periods or days will be used.
Basic Load Capacity (BLC) is the average of the two greatest non-zero monthly Billing Demands
established during the 12-month period which includes and ends with the current Billing Period.
Excess Net Energy means the positive difference between the kWh generated by a Seller and
the kWh supplied by the Company over the applicable Billing Period.
Generation Facility means all equipment used to generate electric energy where the resulting
energy is either delivered to the Company via a single meter at the Point of Delivery or Generation
Interconnection Point, or is consumed by the Seller.
Generation Interconnection Process is the Company’s generation interconnection application and
engineering review process developed to ensure a safe and reliable generation interconnection.
Interconnection Facilities are all facilities reasonably required by Prudent Electrical Practices and
the applicable electric and safety codes to interconnect and safely deliver energy from the Generation
Facility to the Point of Delivery or Generation Interconnection Point.
IDAHO PUBLIC UTILITIES COMMISSION
Approved Effective
Feb. 8, 2007 Jan. 25, 2007
Per ON 30227
Jean D. Jewell Secretary
Idaho Power Company First Revised Sheet No. 84-3
Cancels
I.P.U.C. No. 28, Tariff No. 101 Original Sheet No. 84-3
IDAHO Issued by IDAHO POWER COMPANY
Issued per IPUC Order No. 30227 John R. Gale, Vice President, Regulatory Affairs
Effective - January 25, 2007 1221 West Idaho Street, Boise, Idaho
SCHEDULE 84
CUSTOMER ENERGY
PRODUCTION NET METERING
(Continued)
DEFINITIONS (Continued)
Generation Interconnection Point is the point where the conductors installed to allow receipt of
Seller’s generation connect to the Company’s facilities adjacent to the Seller’s Point of Delivery.
Point of Delivery is the retail metering point where the Company's and the Seller’s electrical
facilities are interconnected to allow Seller to take retail electric service from the Company.
Prudent Electrical Practices are those practices, methods and equipment that are commonly used in
prudent electrical engineering and operations to operate electric equipment lawfully and with safety,
dependability, efficiency and economy.
Schedule 72 is the Company’s service schedule which provides for interconnection to non-utility
generation or its successor schedule(s) as approved by the Commission.
Seller is any Customer that owns and/or operates a Generation Facility and desires to
interconnect the Generation Facility to the Company’s system to potentially sell net surplus energy to the
Company.
MONTHLY BILLING
The Seller shall be billed in accordance with the Seller’s applicable standard service schedule,
including appropriate monthly charges.
CONDITIONS OF PURCHASE AND SALE
The conditions listed below shall apply to all transactions under this schedule.
1. Balances of generation and usage by the Seller:
a. If electricity supplied by the Company during the Billing Period exceeds the
electricity generated by the Seller and delivered to the Company during the Billing Period, the
Seller shall be billed for the net electricity supplied by the Company at the Seller’s standard
schedule retail rate, in accordance with normal metering practices.
b. If electricity generated by the Seller during the Billing Period exceeds the electricity
supplied by the Company during the Billing Period, the Seller:
i. Shall be billed for the applicable Demand and other non-energy charges for
the Billing Period under the Seller’s standard service schedule, and
IDAHO PUBLIC UTILITIES COMMISSION
Approved Effective
Feb. 8, 2007 Jan. 25, 2007
Per ON 30227
Jean D. Jewell Secretary
Idaho Power Company First Revised Sheet No. 84-4
Cancels
I.P.U.C. No. 28, Tariff No. 101 Original Sheet No. 84-4
IDAHO Issued by IDAHO POWER COMPANY
Issued per IPUC Order No. 30227 John R. Gale, Vice President, Regulatory Affairs
Effective - January 25, 2007 1221 West Idaho Street, Boise, Idaho
SCHEDULE 84
CUSTOMER ENERGY
PRODUCTION NET METERING
(Continued)
CONDITIONS OF PURCHASE AND SALE (Continued)
ii. Shall be financially credited for the Excess Net Energy delivered to the
Company during the Billing Period at the Seller’s standard service schedule retail rate for
Schedule 1 or Schedule 7 service. Sellers taking service under schedules other than
Schedule 1 or Schedule 7 will be credited an amount per kWh equal to 85 percent of the
most recently calculated monthly per kWh Avoided Energy Cost for the kWh of Excess Net
Energy delivered to the Company.
iii. Shall not be financially credited for Excess Net Energy delivered to the
Company if taking service under a schedule other than Schedule 1 or Schedule 7 and the
qualified Seller is utilizing the One-Meter Option.
iv. Shall, if taking service under a schedule other than Schedule 1 or Schedule
7, be billed the applicable retail rate for any net usage delivered by the Company and
recorded on the Seller’s generation meter.
2. As a condition of interconnection with the Company, the Seller shall:
a. Complete and maintain all requirements of interconnection in accordance with
the applicable portions of Schedule 72.
b. Complete and maintain all requirements of the Company’s Generation
Interconnection Process.
c. Obtain written confirmation from the Company that all conditions to
interconnection have been fulfilled prior to operation of the Generation Facility. Such
confirmation shall not be unreasonably withheld by the Company.
3. The Seller shall never deliver or attempt to deliver energy to the Company’s system
when the Company’s system serving the Seller’s Generation Facility is de-energized for any reason.
4. The Company shall not be liable directly or indirectly for permitting or continuing to allow
an attachment of a net metering facility to the Company’s system, or for the acts or omissions of the
Seller that cause loss or injury, including death, to any third party.
5. The Seller is responsible for all costs associated with the Generation Facility and
Interconnection Facilities. The Seller is also responsible for all costs associated with any Company
additions, modifications, or upgrades to any Company facilities that the Company determines are
necessary as a result of the installation of the Generation Facility in order to maintain a safe, reliable
electrical system.
IDAHO PUBLIC UTILITIES COMMISSION
Approved Effective
Feb. 8, 2007 Jan. 25, 2007
Per ON 30227
Jean D. Jewell Secretary
Idaho Power Company
I.P.U.C. No. 28, Tariff No. 101 Original Sheet No. 84-5
IDAHO Issued by IDAHO POWER COMPANY
Issued per IPUC Order No. 30227 John R. Gale, Vice President, Regulatory Affairs
Effective - January 25, 2007 1221 West Idaho Street, Boise, Idaho
SCHEDULE 84
CUSTOMER ENERGY
PRODUCTION NET METERING
(Continued)
CONDITIONS OF PURCHASE AND SALE (Continued)
6. The Company shall not be obligated to accept, and the Company may require the Seller
to curtail, interrupt or reduce deliveries of Energy if the Company, consistent with Prudent Electrical
Practices, determines that curtailment, interruption or reduction is necessary because of line
construction or maintenance requirements, emergencies, or other critical operating conditions on its
system.
7. If the Company is required by the Commission to institute curtailment of deliveries of
electricity to its customers, the Company may require the Seller to curtail its consumption of electricity
in the same manner and to the same degree as other Customers within the same customer class who
do not own Generation Facilities.
8. The Seller shall grant to the Company all access to all Company equipment and facilities
including adequate and continuing access rights to the property of the Seller for the purpose of
installation, operation, maintenance, replacement or any other service required of said equipment as
well as all necessary access for inspection, switching and any other operational requirements of the
Seller’s Interconnections Facilities.
IDAHO PUBLIC UTILITIES COMMISSION
Approved Effective
Feb. 8, 2007 Jan. 25, 2007
Per ON 30227
Jean D. Jewell Secretary