Loading...
HomeMy WebLinkAbout20210407Western Aircraft to Staff 1-5.pdfDAVID H. LEROY Attorney At Law 802 West Bannock Street, Suite 201 Boise, Idaho 83702 Telephone: (208) 342-0000 Facsimile: (208) 342-4200 Idaho State Bar No. 1359 BEFORE THE IDAHO PUBLIC UTILITIES COMMISSION WESTERN AIRCRAFT, INC, Complainant, VS. SUEZ WATER IDAHO, INC, Respondent. ) ) ) ) ) ) ) ) ) ) Case No. SUZ-W-21-01 COMPLAINANT'S RESPONSES TO THE FIRST PRODUCTION REQUEST OF THE COMMISSION STAFF TO WESTERN AIRCRAFT, INC. COMES Now Complainant, Western Aircraft, Inc., by and through its attorney of record David H. Leroy, and to the First Production Requests of the Commission Staff hereby responds, replies and provides documentation as follows: REQUEST NO. 1: In its Complaint, Western asks the Commission to provide relief by allowing "a temporary domestic water connection to Hangar O from the existing Hangar 1 water line, pending the final resolution of this matter .. " Complaint at 6. Please provide the following information: a. Please provide a drawing showing the routing, size, ad capacity of the proposed temporary connection. RESPONSE l(a) Attachment "A" shows the location and installation of a new two inch domestic service line forty two feet in length from the existing Suez main line to serve Hangar 0. COMPLAINANT'S RESPONSES -l RECEIVED 2021April 2, PM 4:56 IDAHO PUBLIC UTILITIES COMMISSION b. ls it Western 's intent that this temporary line provide water for fire service? If so, will the proposed temporary line be able to provide the necessary fire flows? RESPONSE l(b) No. The temporary line will provide only domestic water service to Hangar 0. c. Will Western be able to occupy Hangar O without it receiving fire service? RESPONSE I (c): Fire service to Hangar O is provided solely from the private fire tank onsite. Note that Hangar O contains a 300,000 gallon fire tank located and illustrated on Attachment "A". This tank is fed from an existing 4" Suez line off Kennedy Street. The feed to the tank from Suez is needed, but there is no new direct connection from Suez to Hangar 0 required for fire flow. d. If this temporary connection were made, does Western intend to continue construction of the covered walkway connecting Hangars O and I? RESPONSE NO. l(d): Yes. The 42 foot long by 11 foot wide walkway is not a "building," but we intend to work with the Commission and Suez to resolve the issues. REQUEST NO. 2: What are the fire flow requirements for Hangar O and Hangar 1? RESPONSE NO. 2: Per Clarence McLain of Tribal Fire Systems, the fire system is a combined system that covers Hangars 0, 1, and 2. The sizing is determined by the building with the largest demand. Hangar O is the largest. However, system sizing is greatly reduced by the on-site storage tank and adds a 500 GMP hose allowance. For Hangar O this calculates to a need for 1,750 GPM (1,250 sprinklers+ 500 hose) at 20 psi. Thi s would be 5,500 GPM without using the storage tank to meet the 120-minute duration. See also Attachment "C." REQUEST NO. 3: In its Complaint (2B), Western asks the Commission to either approve COMPLAINANT'S RESPONSES - 2 the revised connection plan prepared by T.O. Engineers on August 20, 2020, or to "indicate which of the (other) previously proposed alternative solutions it endorses so as to allow a water service connection to Hangar 0 ... " Please provide a list and descriptions of the solutions that Western would like the Commission to consider. RESPONSE NO. 3: In light of new information developed over recent weeks, Western Aircraft would like to purpose a new alternative plan to reach a compromise with Suez. See Attachment "B" illustrating the same. The plan is contingent upon two approvals from the City of Boise: 1. Western Aircraft needs approval from the City of Boise to reconfigure the existing fire system in Hangar 1 which would allow the 4" fire service from the Suez main line in Boeing to be abandoned. 2. Western Aircraft needs approval to relocate the proposed fire hydrant from the location adjacent to the fire room in Hangar I to a new location at the NE corner of the proposed concrete apron with a connection to the Suez main line in Ingalls. Following these approvals from the City of Boise building department, Western Aircraft proposes the following solutions as shown on Attachment "B": 1. Reconfigure the private fire system in Hangar l and abandon the fire service line from Suez. 2. Install a new fire hydrant at the NE corner of the new apron as required by the Boise City Fire Department. 3. Cap and abandon the 8" Suez main line in Boeing just east of the building service line connection. COMPLAINANT'S RESPONSES -3 4. Construct the Western Aircraft enclosed walkway as proposed between Hangar 1 and Hangar 0. REQUEST NO. 4: Regarding the non-potable lines encountered during Western's excavation for the Hangar O project: a. What is the purpose of these lines and whom do they serve? RESPONSE 4(a): It is assumed this question is in regard to the fire water line that runs from the storage tank to the fire room in Hangar 1. The original line was installed in a straight line from the tank to the fire room. The line was re-rerouted around the footprint of the new hangar as part of this project. The lines are privately owned and maintained to serve the fire system of the Western Aircraft facility. b. Who installed these lines? RESPONSE 4(b): Both the original and new lines were installed by Western Aircraft contractors. c. Were these lines installed before, or after the Suez main on Boeing? RESPONSE 4(c) The original lines were installed in roughly 1990 based on a date from drawings provided by the owner. The new fire line was installed in the summer of 2020 as part of this project. The installation date of Suez main on Boeing is unknown. d. Please provide a drawing showing the location of these lines. Are they above or below the Suez main? RESPONSE 4(d): See Attachment "B." REQUEST NO. 5: Regarding the sewer line encountered dw-ing Western's excavation for the Hangar O project: COMPLAINANT'S RESPONSES -4 a. Whom does this sewer line serve? RESPONSE 5(a): This sewer line was originally a City of Boise mainline sewer which served the Western Aircraft building. As part of this development, we abandoned the "mainline" sewer and replaced it with a sewer "service" line that would continue to serve the existing hangars in addition to the new Hangar 0. The new sewer lines were installed at the same depth and alignment as the existing sewer main, but located a few feet West for phasing purposes. See Attachment "D" consisting of three pages the illustrating the various historical lines. b. Who installed this line? RESPONSE 5(b ): The original sewer main was owned by the City of Boise. The new sewer line was installed by Western Aircraft. c. Was this line installed before or after the Suez main on Boeing? RESPONSE 5(c): The original sewer line install date is unknown. The new service line was installed in Summer of 2020 as a replacement to maintain service to the existing building. d. Please provide a drawing showing the location of this line. ls it above or below the Suez main? RESPONSE 5(d): See Attachments "Band "D." There are two sewer line locations in question: i. Location A-North of new Hangar 0 ii. Location B-South of new Hangar 0 As to Location A -The sewer service was installed below the Suez waterline. Vertical separation is not compliant with IDEQ regulations. The project was intended and planned to relocate and lower the waterline in this area to meet IDEQ standards, but such waterline work COMPLAINANT'S RESPONSES -5 was put on hold by Suez. As to Location B-The sewer mainline is above the Suez "lowered main" water line. This crossing is existing and was not modified as part of this project. REQUEST NO. 6: IDENTIFICATION OF PERSON PREPARING RESPONSES: RESPONSE NO. 6: Brendon Daniels, T-O Engineers and Louie Gravel, Western Aircraft. REQUEST NO. 7: IDENTIFICATION OF RECORD HOLDERS: RESPONSE NO. 7: Same as Response 6 above. DA TED THIS~ day of April, 2021. David H. Leroy, Attorne for the Complainant COMPLAINANT'S RESPONSES -6 CERTIFICATE OF SERVICE I hereby certify that on this .,J V'c{ day of April, 2021, I caused a true and correct copy of the within instrument to be sent to: John R. Hammond Jr. Deputy Attorney General Idaho Public Utilities Commission P.O. Box 83720 Boise, Idaho 83720-0074 email: joh.han1mond@puc.idabo.gov David H. Leroy Defense Counsel P.O. Box 193 Boise, Idaho 83 702 email: dave@dleroy.com COMPLAINANT'S RESPONSES -7 Preston N. Carter Blake W. Ringer Givens Purs ley LLP Boise, Idaho 83701-2720 email: prestoncarter@givenspursley.com email: blakeringer@givenspursley.com Davalee Davis, Executive Assistant I i I !! ~ i ; I I I 1:1 I ;,; ' m z z s ~ m ~ ! .;, . Ii ~ i i -; I j1t ! I I ~ t I I is ! !! J ~ I I I ! i i Ii 2 ~ 30 @ 60 tELOCATED KISTING HP ISTALLEDB CONTRACT x 120 180 EXISTING WESTERN AIRCRAFT HANGAR "' CESSNA STREET T" ~ ~ ~...&..-· .l;e-' ,.., ---. • . , ,! ·.,;. ., <:t ' . • ~ ◄ ... . ... .. . :: . : · •. . • 'I I . ... . ... ~ :·: . tON·~•1 •• ... · .. :~. ...:·. •·. -:· .. ·. ~- • • ' • PROPOSED • CONCRETE APRON • r • ~ t I . ' .... I • : -':~ • • ; ... • . , .. ·~· . . . • ~ •• l • ., • •• I• ~ • • •• ,,. 1 ,. ; • .,. . •. -, ~--... ·,:=:• .; .... --. . ·. · ... ~ .. Iii ~ ~ en en ~ ~ u; .,__,.. J,.--K ~ ....---""' IDAHO MILITARY DIVISION RESTRICTED ACCESS 02Q2.1 MiamoflCorpo,"IUOn C 2021 ~C>OIES(202I) Ol!lribu6an AlrtMOS RD..OCAltD ,.Jlll!.OEPAATMl.NT ,~.°"~tM>HAHCW!t •~ UISINl £)0Sflf,C.HA.'CNI ~... ~ ,.,,,.,..---w-.ru11CJMC£ ~ • . -----~ "'1 -,.,.,.,.., -~ ..... ENLARGED DETAIL SCALE. 1"s20' . ---- LEGEND 1t•1 E>US1 If.JG WATER 1..1r~E ----- -----w -----PROPOSED WATER LINE -... TEMPORARY SERVICE APPROVAL NEEDED FOR BUILDING OCCUPANCY: 1. INSTALL FIRE HYDRANT ON KENNEDY ST. AT SW CORNER OF NEW OFFICE BUILDING. 2. INSTALL 2" DOMESTIC SERVICE TO NEW OFFICE BUILDING, LOCATED ON NORTH SIDE OF BUILDING. ii:J T•O ENGINEERS 1998 W. JUDITH LANE I ~ PHONE (208}~33-1900 WWW TO-ENGINEERS.COM 8 @) HU. GJ1--.A«:r11-_.L.,.Eoli.dli; [l,\fE:lZl71 411!Zl1 WESTERN AIRCRAFT TEMPORARY WATER LINE EXHIBIT BOISE. IDAHO 83705 sue2 TO: Coleen Baker Glancey Rockwell & Associates EMAIL: office@grboise.com DATE: April 19, 2019 SUBJECT: 4300 S. Kennedy St. COMMENTS: SUEZ 8248 West Victory Rd. Boise, ID 83709 Phone: 2o8. 362. 7354 Fa><: 2o8. 362. 3858 suezidcustserv@suez.com Our records indicate the following water pressure and volume at: 4300 S. Kennedy St.: Pressure at average demand is 55 psi Flow of 2,000 gpm at 20 psi residual pressure At fire hydrant 2937 at corner of Boeing & Kennedy This information represents the water system under maximum-day conditions. The pressures and flows are subject to change, however, depending on system demand and changes in system operations. This document shall be attached to the architectural plan sets, both for "Fire Department reviewed" and "Construction Approved" sets. It is provided for uniformity in fire sprinkler design criteria. If you have further questions or need information on the volume of water for a conditional use application or design review, please feel free to call. Sincerely, SUEZ \ -----~-.....,,...., [[lW -~ i I n1Trrru: 1 'I I I \ill.' I I I • rnnffn J\ ~ ,, J \ I I 111 m\ --~ I I __ , -.. --... ·-~c:=.== 1 '--f ..:.:..,;-..:.:.,;-..::., I""' 1 ~~---¾:: ~~­~-::=:::::f-,/ j -··-·--· PIPE SUPPORT OETAll t ) b.1_Wtt ·.Clv _ ........ -- ·--\ t-" -1 1-- Water/Sewer crossing Location A. .... I SUEZ main was to be relocated and lowered for clearance with replaced sewer service lines to be compliant with DEQ regulations. I .. ·. :.\ \'.\·· ·· .. ·. · .. · ·. I : ...... ··~: ... · · . .-· .. · .. ·:. ' ...... \ -~~-·. ··.·'.I -~_:. -r ----~· .. :_ .: =··: A ---= i""'tt •·1--·---1•-■-,,-M_.1 --~ ... --·••-..:-----~ , _____ ..,. __ .. __ ,., ___ _ •11.i. ______ ..,_, __ .,._,_ ·~···-....... -··-"'--.... """ __ ,_n;t ... ,_ ... ______ _ --""·----...... -,a_,_1••""-"°• .... --~-"'---t•·- IKEVNOIU t =.t--.-:---•---­• ~·-.,~-·11.._, ~) :::."":: -~----·---­.--.....,-~-"'--"'- Existing Boise Sewer main crosses over top of the SUEZ "lowered" water main. No changes to this cross as part of this project. n =:,',.":'~a:-."::f.!:i'f'""­ w-=.1~=::-=!:.~·----•..---,---­Q----·--.... ~: ·. •.· ; ' .. ::.::::::o.• Water/Sewer crossing ·. · :-l location B • · .. -~I " ,..__.,., ., -•"'-' . } ·--------. , _____ , .. .,, ....... _ &II · :::-.=..---~··· .. :=.::.=--·····-,_., ·=~----~~\_ ,~7 lf!i:::.- ·-1 ·--0, f;:!0 ,--.:-:::=.-:==~ j& ,... .. ,:~ , __ -=.:~~4:-r\• .... \ M ::,,, ___ ...,. ..,..._ ... _ --=:".:.-•~ I ~ •-•" --.. ~··-/] \ L ............ ..: _-.:::::·::: ----U•to•••---• ----r-•• -• --• ----=.-.-= ..,.,., ____ ,_, __ ,,.,_ -U.• ....... _ .. __ ..... ...__ __ ___ ENClogD WALJ(.WAY CROSSING OETAU,/"; ~. "'"' \cio t-" -1 ·--\ lf~l: r _1_-- --I· .---..... -~ -.~.~=• :.:.=.:::.=: ENCLOSED WA1.KWAY CROSSING OETAli.. > k.to&L• I-~ .... ---. • :lo ----11 ....... l---------- 1 . I ..... -·--~::-==-- .:0 -:. l(IIJ.e_<:J~Jgn i ~ 1ii:J•~•--u•• ~ -;:=:: ...: - .... <{ 5~ er er <~ zZ er <t ~:i:: V11-W "'­ ::: <{ • .e ~== er ,u er a. ~<{ ~ u z V1 ~5~ u1-U Q<.11 -~~t -_Q JT LIIV PLAN C3.0 N/A ijl• N/A :.1 I( •&31 \ '631 MOUMl"AJH STATES PAINTI N/A • -·~ los60 r.i7i! N/A N/A Ill i l ,I,; '560 IY/4 tii .t:. f :i Ill ,,aa n,n ~w W.BoeingSt lftm J • "71. =t• ~ N/A ,_ N/A 4S058C1£>hGSl' Ill ~ :I :I • Ill •,o) i1~~:".:: -~ '· -, ..,.,. .•, \; I .,__,_ ·--., _,•~11 ...... -~' 4 Q. ,._,. ..... / r~~ - -.., ... ................... ,~.------ ,' r ~~-- - -n:• I .----... -Boise Sewer main. Lowered main for sewer clearance. Installed prior to any wor11 on Hangar O • tii Ill i ~ Ill -I' sue2 • , • F•Dale cn8/2019,_ I t -11nc11•1001ee1 SUEZ _ ..... Vlc:wJ-... .......... UJN ,_...,.,,.. --0 SO 100 200 )Fe« 300 n-....... .....,....,..r.m:,....,,0,...,..,.-111~-..... ------,..~ ........... "__,·" ................. _.,..~., ... ----------....,-aua.-•--~ .. ..._~.., .. , -ef-~tlt,.,..._..,_._Wlltdllll ........ M1c.-,.w.-.. 1ow.11w.,_,. __ ., __ ~.,..,... ...... ,.. ... ~----,..._,,.......,. ...._..,1Hlll-'f .... ..,_.....,..IIM....,.,,_...._,MIIC.-W. .... ;; ~1 W&oei,aist • ,.,., i· iii 1,f ~I. ~ l.l ~ Clfl ~ /I~ J .! ,!i ~~1-~;L_ $ Ill J~~,, "'· "' .. Ill I l ---;::,, " ,._,,. !'~ -_d JJII j,ri~ l ;.=-½ •• J l "' w ast ~ ' L.. ' ... " '1 i ~ ., r ... " "' woormanSt - tii .l!I ii r ... u, tii .!IJ ii : ... Ill WCessnast ,! "' ,! "' · . .riMJ , .. 66 ·:i~s ' fltt - \ ~ .. • Installed new mainline termination manhole as part of Hangar O project. over top S 't -1321 Boise sewer main abandon and replaced with a private service line as part of Hangar 0 expansion.