Loading...
HomeMy WebLinkAbout20210326Staff 6-10 to INT.pdfDAYN HARDIE DEPUTY ATTORNEY GENERAL IDAHO PUBLIC UTILITIES COMMISSION PO BOX 83720 BOISE, IDAHO 83720.0074 (208) 334-0312 IDAHO BAR NO. 9917 r-.;.r.i:ii /#{*1 ;ii;: ii:it e* PH t: *0 :. ::;,- *..,:l rl;1,-.h/',-, ,. i,;i€i#";; Street Address for Express Mail: 472W. WASHINGTON BOISE, IDAHO 83702.5918 Attorney for the Commission Staff BEFORE THE IDAHO PUBLIC UTILITIES COMMISSION IN THE MATTER OF INTERMOUNTAIN GAS COMPANY'S APPLICATION FOR APPROVAL TO CHANGE DEPRECIATION AND AMORTIZATION RATES CASE NO. INT-G.2I-01 SECOND PRODUCTION REQUEST OF THE COMMISSION STAFF TO INTERMOUNTAIN GAS COMPANY The Staff of the Idaho Public Utilities Commission, by and through its attorney of record, Dayn Hardie, Deputy Attorney General, request that Intermountain Gas Company (Company) provide the following documents and information as soon as possible, or by FRIDAY, APRrL 16,2021. This Production Request is continuing, and the Company is requested to provide, by way of supplementary responses, additional documents that it, or any person acting on its behalf, may later obtain that will augment the documents produced. Please provide answers to each question, supporting workpapers that provide detail or are the source of information used in calculations. The Company is reminded that responses, pursuant to Commission Rules of Procedure, must include the name and phone number of the person preparing the document, and the name, location, and phone number of the record holder, and if different, the witness who can sponsor the answer at hearing if need be. Reference IDAPA 31.01.01.228. SECOND PRODUCTION REQUEST TO INTERMOUNTAIN GAS MARCH 26,2021 ) ) ) ) ) ) ) ) ) 1 with formulas activated. REQUEST NO. 6: In Section 3.4 of its Depreciation Study, Concentric states that it uses a residual measure based on a least squares solution of the difference between the stub curve and the survivor curve. Please confirm that the following equation describes this residual measure: restdua.lmeasttre =f,1(data; - cur$€i)2 TL where datai is the ith data point, ctttr€i is the corresponding point from the survivor curve, and r is the number of data points used in the computation. If this equation does not correctly describe the residual measure as described in Section3.4, please provide a corrected equation with explanation of the variables used in it. REQUEST NO. 7: In Section 3.4 of its Depreciation Study, Concentric states, "This Residual Measure is based on a least squared solution of the differences between the stub curve (or original data points) and smooth survivor curve, which also requires a balancing of the differences above and below the stub curve." Please explain how this balancing is performed. REQUEST NO. 8: In its Depreciation Study, Concentric evaluates the fit of several survivor curves using the residual measure. For example, when evaluating the curve fit for account 367 (Transmission Mains) in Section 3.5.1, the Company states, "The recommended retirement rate analysis provides a statistical residual measure of 1.842 which indicates a good fit." Please answer the following questions: a. What values of the residual measure does Concentric take to indicate a good fit? b. What values of the residual measure does Concentric take to indicate a poor fit? c. How did Concentric determine the criteria used to judge whether the fit is good or poor? SECOND PRODUCTION REQUEST TO INTERMOUNTAIN GAS MARCH 26,20212 In addition to the written copies provided as response to the questions below, please provide all reouested charts- tahles^ and workoaoers in their native electronic file format (i e F,xcel)- on CD REQUEST NO. 9: Pages 6-23 through6-26 of Concentric's Depreciation Study provide the data and survivor curve for Account 367.00, Transmission Mains. For this account, Concentric chose a 58-R3 survivor curve. According to Section 5.2,the first numeral (58) indicates the average life estimated from curve fiUing. Please explain how, given that92.79Yo of the plant in account 367.00 was still in service at 58 years Concentric chose the 58-R3 curve. REQUEST NO. 10: Pages 6-30 through6-32 of Concentric's Depreciation Study provide the data and survivor curve for Account 370.00, Transmission-Communication Equipment. According to this data,l00o/o of the equipment in this account was still in service at 47.5 years. Please explain how Concentric fit this data to a curve with a 35-year average life. DATED at Boise, Idaho, this 2(h day of March2D2l. Dayn Deputy Attomey General i:umisc:prodreq/intg2l.ldh prod req2 SECOND PRODUCTION REQUEST TO INTERMOUNTAIN GAS J MARCH 26,2027 CERTIFICATE OF SERVICE I HEREBY CERTIFY THAT I HAVE THIS 26TH DAY OF MARCH 2021, SERVED THE FOREGOING SECOND PRODUCTION REQUEST OF THE COMMISSION STAFF TO INTERMOUNTAIN GAS COMPAI\"Y, IN CASE NO INT-G-21.01, BY E.MAILING A COPY THEREOF, TO THE FOLLOWNG: LORI BLATTNER DIR _ REGULATORY AFFAIRS INTERMOUNTAIN GAS CO PO BOX 7608 BOISE ID 83707 E-MAIL : lori.blattner@intgas.com PRESTON N CARTER GIVENS PURSLEY LLP 601 W BANNOCK ST BOISE ID 83702 E-MAIL : prestoncarter@ givenspursley.com kendrah@ eivenspursley. com SECRETAR CERTIFICATE OF SERVICE