HomeMy WebLinkAbout20141016IES_Replacement SprinkPkg_Usage.docx
E1 = annual kWh savings for replacing the pivot package
E2 = Estimated flow savings per pivot package replacement (118 gpm)
E3 = Average operating pressure (65 psi)
E4 = Average pumping plant efficiency (60% or 0.6)
E5 = Estimated average annual operating hours (1,940 hours)
Equation Constants
Conversion factor from psi to feet of head = 2.31
Conversion factor from hp to kW = 0.746
Units conversion factor for water horsepower calculation = 3,960