HomeMy WebLinkAbout20141016IES_Pivot Pressure Regulator Replacement_Demand Savings.docx D1 = kW savings for replacing pivot pressure regulators D2 = Estimated leaking flow rate per regulator (1.23 gpm) D3 = Average pump operating pressure (65 psi) D4 = Average pumping plant efficiency (60% or 0.6) D5 = factor to average demand savings from the irrigation season over the entire year (5/12) Equation Constants Conversion factor from psi to feet of head = 2.31 Conversion factor from hp to kW = 0.746 Units conversion factor for water horsepower calculation = 3,960