Loading...
HomeMy WebLinkAbout20141016IES_Nozzle Replacement_Demand Savings.docx D1 = kW savings per nozzle D2 = Flow rate of worn nozzle (6.41 gpm) D3 = Average operating pressure with worn nozzles (45 psi) D4 = Average pumping plant efficiency (60% or 0.6) D5 = Flow rate of new nozzle (5.12 gpm) D6 = Average operating pressure with new nozzles (50 psi) D7 = Average number nozzles per line (33 nozzles) D8 = Average number of nozzles per system (84 nozzles) D9 = Number of nozzle replacements resulting in energy savings (67% or 0.67) D10 = factor to average demand savings from the irrigation season over the entire year (5/12) Equation Constants Conversion factor from psi to feet of head = 2.31 Conversion factor from hp to kW = 0.746 Units conversion factor for water horsepower calculation = 3,960