Loading...
HomeMy WebLinkAbout20141016IES_Dual Sprinkler Package_Usage Savings.docx E1 = annual kWh savings for a dual sprinkler package conversion E2 = Flow rate with standard pivot nozzles (885 gpm) E3 = Average pump operating pressure (65 psi) E4 = Average annual operating hours (1,940 hours) E5 = Average pumping plant efficiency (60% or 0.6) E6 = Average operating hours at full flow with a dual nozzle package (1,455 hours) E7 = Reduced flow rate with dual sprinkler nozzles (649 gpm) E8 = Average operating hours at reduced flow with a dual nozzle package (485 hours) Equation Constants Conversion factor from psi to feet of head = 2.31 Conversion factor from hp to kW = 0.746 Units conversion factor for water horsepower calculation = 3,960