Loading...
HomeMy WebLinkAbout20141016IES_Custom Sprinkler Package_Usage Savings.docx E1 = annual kWh savings for replacing the pivot package E2 = Original pivot package flow rate (gpm) E3 = Acres for full circle pivot E4 = New pivot package flow rate (gpm) E5 = Average operating pressure (68 psi) E6 = Averagelift from water surface to pump (5 feet for surface pumps and 219 feet for well pumps) E7 = Average pumping plant efficiency (65% or .65) E8 = Savings realization factor (.8) E9 = Average annual operating hours (1,158 hours) Equation Constants Conversion factor from psi to feet of head = 2.31 Conversion factor from hp to kW = 0.746 Units conversion factor for water horsepower calculation = 3,960 Assumed increase in pivot flow rate due to wear = 1 gpm/acre