Loading...
HomeMy WebLinkAbout20141016IES_Custom Sprinkler Package_Demand Savings.docx D1 = kW savings for replacing the pivot package D2 = Original pivot package flow rate (gpm) D3 = Acres for full circle pivot D4 = New pivot package flow rate (gpm) D5 = Average operating pressure (68 psi) D6 = Average lift from water surface to pump (5 feet for surface pumps and 219 feet for well pumps) D7 = Average pumping plant efficiency (65% or 0.65) D8 = Savings realization factor (0.8) D9 = factor to average demand savings from the irrigation season over the entire year (5/12) Equation Constants Conversion factor from psi to feet of head = 2.31 Conversion factor from hp to kW = 0.746 Units conversion factor for water horsepower calculation = 3,960 Assumed increase in pivot flow rate due to wear = 1 gpm/acre