Loading...
HomeMy WebLinkAbout20141016IES_Custom Pressure Regulators_Usage Savings.docx E1 = annual kWh savings for pivot pressure regulator replacement E2 = Estimated leak per regulator (0.4 gpm) E3 = Number of regulators being replaced E4 = Average operating pressure (68 psi) E5 = Average lift from water surface to pump (5 feet for surface pumps and 219 feet for well pumps) E6 = Average pumping plant efficiency (65% or 0.65) E7 = Savings realization factor (0.8) E8 = Average annual operating hours (1,158 hours) Equation Constants Conversion factor from psi to feet of head = 2.31 Conversion factor from hp to kW = 0.746 Units conversion factor for water horsepower calculation = 3,960