Loading...
HomeMy WebLinkAbout20190924Avista to Staff McClain Crow 07 Attach.pdfMain Office: 24919 Canston Court Spring, Texas 77389 Tel: 281-357-5705 Fax: 281-357-5063 McLain Crow & Associates,LLC www.mclaincrow.com Insurance Loss, Management & Consulting Services Branch Office: 26423 Hidden Timber Ln. Katy, Texas 77494 Tel: 281-693-0663 Fax: 281-693-0668 9 September 2008 Underwriters and Insurers at Interest REPORT NO.10 INTERIM INSURED :Avista Corporation 1411 East Mission Avenue Spokane, WA 99220 INSURERS/POLICY NOS.:AIG –2611149 –40% Lloyds c/o R.K. Harrison –NRS10610147 –25% AEGIS –L0149A1A06 –20 % Starr Tech –EUTN01938630 -11% Energy Insurance Mutual –310218-06GP–4% POLICY TERM :November 25, 2006 to November 25,2007 LOCATION OF LOSS :Coyote Springs Substation Near Boardman, OR DATE OF LOSS :March 23, 2007 TYPE OF OCCURRENCE :Electrical Arcing of Transformer CLAIM OR REF.NUMBER :AIG –229-006448 Lloyds c/o R.K. Harrison –150174(3220) AEGIS –38920 Starr Tech -253 Energy Insurance Mutual –903921-06GP MCA FILE NO.:07MCA01 87RC Ladies &Gentlemen: We respectfully submit our interim report in connection with the above referenced matter. AVISTA Corporation 9 September 2008 MCA File # 07MCA0187RC Page No.2 ENCLOSURES 1.None at this time. REQUESTED INFORMATION: 1.Final costs and supporting documentation. DEVELOPMENTS: It was reported that on March 23, 2007 at 7:05 AM the Coyote Springs transformer was taken off line due to alarms that indicated the presence and then rapid increase of Acetylene in the oils.This increase in the gas was noted on the Serveron Unit, the Buchholz relay and the Hydran Gas indicator. Oil samples were also taken and a Dissolved Gas Analysis was performed. This analysis confirmed the increase gas in the oil.Following initial inspection to locate the source and extent of problem that caused elevated gassing, it was apparent that investigation of the transformer problems to affect potential repair could only be conducted only in a controlled factory environment.Based on the forensic examination,complete rebuild of the transformer would be necessary to restore it to serviceability. As of this date the insured has incurred the following costs. In-house costs $ 506,470.05 Siemens Down Payment $ 420,000.00 Transformer Salvage (277,918.00) Oil Salvage (8,690.40) Deductible.$(443,750.00) Total Net of Deductible $ 196,111.65 As previously reported with insurer’s authorization we proceeded to take a partial proof of loss for the partial payment of $196,111.65 as outlined above.A copy of the fully executed partial proof of loss was attached to our last report. Avista has entered into an agreement with Siemens to provide another unit that they intend to use as a spare now that the original spare is in service.The anticipated delivery of this transformer is mid-2009. EXPERTS: With insurers authorization we retained the services of Mr.Ed Feloni to assist us in this matter. SUBROGATION AND SALVAGE: With your authorization we retained the services of Robins, Kaplan, Miller & Ciresi to look in to possible subrogation. OTHER INSURANCE: We are not aware of any other insurance that would apply to this occurrence. AVISTA Corporation 9 September 2008 MCA File # 07MCA0187RC Page No.3 RESERVE: Based on the insured’s calculation and the comments from Mr. Ed Feloni we recommend the current net reserve of $4,044,111.65 be maintained on the file pending developments. As additional information is developed, we will contact you concerning recommendations of any adjustment of these reserves. REMARKS: We will continue to give this matter our closest attention and will inform you of future developments. Should you have any questions or comments, or wish to discuss any of the above items, please feel free to contact me. Please diary your file 45 days pending further activity. Very truly yours, McLain Crow & Associates, LLC Ronald R. Crow, CPCU, ARM, AIC Executive General Adjuster Distribution:VIA E-mail Mr. Patrick Jeremy –AIG Mr. Simon Dawes RK Harrison on behalf of Lloyds Underwriters Mr. Paul Carnovale –AEGIS Mr. Rabindranath Rajkumar –Starr Tech Ms. Ann Joslin -Energy Insurance Mutual Mr. David Bocan –RKMC Mr. William Webster -RKMC