Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Intermountain Gas 260430 Pocatello Construction Construction
IPUC Construction Inspection Inspector(s): Galli Date(s): 260430 Company/Owner: Intermountain Gas Company(IGC) Unit/OPID: 8160 Address: 3500 Bannock Hwy,3075 Stephanie Road City/District: Pocatello Contractor/Job#: Foreman: Operator Supervisor: IGC W012571011, Form 457 M.McCurry Phillip Colborn Job Description: Retire Service/Leak Repair Service System Type: 0 GD ❑ GT ❑ GG One-Call Ticket: 2026163436,2026183410 Total Inspection Days: 1 Tasks: Procedure# Rating Comments 1. Materials—Handling, Storage, Labeling OPS 11 SAT 2. Trenching/Boring—Depth, Clearance OPS 308 SAT OPS 322 3. Bedding/Backfill OPS 308 SAT SF 418 4. Pipe Installation(Tracer Wire) OPS 308 SAT OPS 322 5. Valve Installation OPS 703 N/A 6. Coating Condition OPS 401 N/A OPS 402 OPS 403 7. Manuals—Field Procedures, O &M SAT 8. Testing—Pressure, Duration,Type OPS 505 SAT 9. OQ Qualifications OPS 800 SAT Verified 10. Casing Seal/Installation OPS 325 N/A 11. Service Line Installation OPS 302 N/A 12. Tie-In/Hot Tapping OPS 600 N/A 13. Meter Location/Regulator Testing OPS 302 N/A 14. Equipment Calibration Verification OPS 501 SAT Verified 15. EFV Installation OPS 301 N/A 16. MAOP OPS 602 N/A OPS 606 OPS 900 OPS 1000 17. Purge OPS 603 N/A 18. Safety Equipment SF 418 SAT JSA and Fire Extinguisher SF 422 19. Abandonment OPS 607 1 N/A IPUC Form 4 Rev.12/08/2025 IPUC Construction Inspection 20. Line Locating OPS 611 SAT 21. Plastic Pine OPS 307 SAT -Joiner(s) Qualified OPS 309 -Fusion Tools OPS 325 - Squeezing OPS 800 -Heat Plate -Joining Procedure 22. Steel Pine OPS 200 N/A -Welder(s) Qualified OPS 201 Pipe/Coating—Inspected/Repaired OPS 202 - Cathodic Protection OPS 306 -Non-Destructive Testing OPS 401 -Welding Procedures OPS 407 -Removal of asbestos wrap OPS 402 -Exothermic Welding OPS 403 Additional Comments: Observations included(3500 Bannock Hwy,Pocatello, ID) (Aldyl-A Service Retire): Safety equipment, JSA,valid dig ticket, line locating(hand dig to daylight service), verified operator qualifications, correct trench depth, squeeze off,mechanical fittings (met-fit end cap), leak test with soap,bedding with native soil and backfill. Observations included(3075 Stephanie Road,Pocatello, ID)(Leak Repair Service Line): Safety equipment, JSA,valid dig ticket, line locating(hand dig to daylight service), verified operator qualifications, correct trench depth, squeeze off,mechanical fittings(met-fit couplers),pressure test at 97 psi for 15 min, leak test closed fitting with soap,bedding with native soil and backfill. All observed procedures were followed in accordance with IGC procedures. Corrective Action Required: ❑ Yes N No Compliance Letter#: NA Lead Inspector: Galli Date: Reviewer: Brooks Date: 260430 Signature: `J Signature: k6051 IPUC Form 4 Rm 12/08/2025