Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Intermountain Gas 260303 Meridian Construction Construction
IPUC Construction Inspection Inspector(s): Galli, Green Date(s): 260303 Company/Owner: Intermountain Gas Company(IGC) Unit/OPID: 8160 Address: Ustick Road between Linder and Ten Mile City/District: Meridian Contractor/Job #: W012426130 Foreman: Operator Supervisor: None K. Oakes Job Description: 6" Main Line System Type: M GD ❑ GT ❑ GG One-Call Ticket: 2026101206 Total Inspection Days: 2.0 Tasks: Procedure Rating Comments 1. Materials—Handling, Storage, OPS 11 SAT 6" inch dated 07/2024 Labeling 2. Trenching/Boring—Depth, Clearance OPS 308 SAT OPS 322 3. Bedding/Backfill OPS 308 N/A SF 418 4. Pipe Installation (Tracer Wire) OPS 308 N/A OPS 322 5. Valve Installation OPS 703 N/A 6. Coating Condition OPS 401 N/A OPS 402 OPS 403 7. Manuals—Field Procedures, 0 & M SAT IGC procedures followed 8. Testing—Pressure, Duration, Type OPS 505 N/A 9. OQ Qualifications OPS 800 SAT Verified 10. Casing Seal/Installation OPS 325 N/A 11. Service Line Installation OPS 302 N/A 12. Tie-In/Hot Tapping OPS 600 N/A 13. Meter Location/Regulator Testing OPS 302 N/A 14. Equipment Calibration Verification OPS 501 SAT Verified 15. EFV Installation OPS 301 N/A 16. MAOP OPS 602 N/A OPS 606 OPS 900 OPS 1000 17. Purge OPS 603 N/A 18. Safety Equipment SF 418 SAT Fire extinguisher and JSA SF 422 19. Abandonment OPS 607 N/A IPUC Form 4 Rev. 12/08/2025 IPUC Construction Inspection 20. Line Locating OPS 611 SAT Potholing 21. Plastic Pipe OPS 307 SAT Observed 6"butt fusion -Joiner(s) Qualified OPS 309 Observed proper rollback of 6"butt -Fusion Tools OPS 325 fusion - Squeezing OPS 800 - Heat Plate - Joining Procedure 22. Steel Pipe OPS 200 N/A - Welder(s) Qualified OPS 201 Pipe/Coating—Inspected/Repaired OPS 202 - Cathodic Protection OPS 306 -Non-Destructive Testing OPS 401 -Welding Procedures OPS 407 - Removal of asbestos wrap OPS 402 - Exothermic Welding OPS 403 Additional Comments: Observations included (Ustick Road between Linder and Ten Mile) Safety equipment, JSA, valid dig ticket, line locating, potholing, verified operator qualifications, verified equipment calibration, correct trench/bore depth, observed butt fusion process, verified proper rollback of completed 6"butt fusions, observed install a weak link prior to boring. Observed employees scrap multiple sections of pipe with greater than 10%wall damage. All observed procedures were followed in accordance with IGC procedures. Corrective Action Required: ❑ Yes ® No Compliance Letter#: N/A Lead Inspector: Galli Date: Reviewer: Brooks Date: ' � 260303 Signature: L �� Signature: Z60305 IPUC Form 4 Rev. 12/08/2025