Avista 260209 & 260210 Bonners Ferry & Moyie Springs Construction
IPUC Construction Inspection Inspector(s): Galli, Brooks Date(s): 260209 & 260210 Company/Owner: Avista Utilities Unit/OPID: 31232 Address: 164 Black Mountain Rd, 70 Appaloosa Rd City/District: Bonners Ferry, Moyie Springs Contractor/Job #: Foreman: Operator Supervisor: None 1036739131 & 1036643054 G. Williams Job Description: %" Service Line System Type: ® GD One-Call Ticket: 260360028 & 260360028 Total Inspection Days: 4.0 Tasks: Procedure# Rating Comments 1. Materials-Handling, Storage, Labeling 3.12-3.13 SAT 3/" dated 06/2025 2. Trenching/Boring-Depth, Clearance 3.15 SAT 24" trench depth 3. Bedding/Backfill 3.15 SAT Bedding with native soil 4. Pipe Installation(Tracer Wire) 3.13 SAT 14-gauge in open trench 12- au e throu h bore 5. Valve Installation 2.14 N/A 6. Coating Condition 2.12 N/A 7. Manuals-Field Procedures, O & M 1.4 SAT All procedures followed 8. Testing-Pressure, Duration, Type 2.12-13/3.18 SAT 102 and 100 psi for 10 minutes 9. OQ Qualifications 4.31 SAT Verified 10. Casing Seal/Installation 3.42 N/A 11. Service Line Installation 3.16 SAT 12. Tie-In/Hot Tapping 3.32 N/A 13. Meter Location/Regulator Testing 2.22 SAT 14. Equipment Calibration Verification 5.11,14,21 SAT Verified 15. EFV Installation 3.16 SAT EFV 1200 16. MAOP 4.15 N/A 17. Purge 3.17 N/A 18. Safety Equipment GESH 4 SAT Fire Extinguisher and JSA 19. Abandonment 5.16 N/A 20. Line Locating 4.13 SAT Hand dig to expose main 21. Plastic Pipe 3.23-25 SAT Lyco fitting - Joiner(s) Qualified 3.34 - Squeeze - Fusion Tools - Heat Plate - Joining Procedure IPUC Form 4 Rev. 12/08/2025 IPUC Construction Inspection 22. Steel Pine N/A -Welder(s) Qualified 3.22 Pipe/Coating—Inspected/Repaired 2.12 - Cathodic Protection 2.32 -Non-Destructive Testing 3.12 - Welding Procedures - Removal of asbestos wrap - Exothermic Welding Additional Comments: IPUC staff traveled to Coeur d'Alene on February 9, 2026. Observations included(164 Black Mountain Road, Bonners Ferry, ID): Safety equipment, JSA, valid dig ticket, verified operator qualifications, verified equipment calibration, correct trench depth, Lyco fitting tee, EFV 1200 installation, tracer wire and bedding with native soil, successful pressure test, squeeze off, backfill and continuity testing. Quizzed employees on applicable AOCs for squeeze off procedures. All observed procedures were followed in accordance with Avista procedures. Observations included (70 Appaloosa Road, Moyie Springs, ID): Safety equipment, JSA, valid dig ticket, hand dig to expose main line, verified operator qualifications, verified equipment calibration, correct trench depth, thumper bore, Lyco fitting coupler, saddle tapping tee, EFV 1200 installation, tracer wire and bedding with native soil, successful pressure test and backfill. Quizzed employees on applicable AOCs of tapping tee installation. All observed procedures were followed in accordance with Avista procedures. Corrective Action Required: ❑ Yes ® No Compliance Letter#: NA Lead Inspector: Galli Date: Reviewer: Brooks Date: 260210 0,�0310 Signature: i' Signature: IPUC Form 4 Rev. 12/08/2025