HomeMy WebLinkAboutIntermountain Gas 260114 Boise Construction IPUC Construction Inspection Inspector(s): Galli Date(s): 260114 Company/Owner: Intermountain Gas Company(IGC) Unit/OPID: 8160 Address: 902, 904, 906 E Logan St City/District: Boise Contractor/Job#: W012412039, Foreman: Operator Supervisor: None W012412042,W012412048 J. Rodriguez Job Description: %" Service Line System Type: © GD ❑ GT ❑ GG One-Call Ticket: 2025530369, 2025530367, 2025530365 Total Inspection Days: 1.0 Tasks: Procedure Rating Comments 1. Materials—Handling, Storage, OPS 11 SAT %" inch dated 11/2025 Labeling 2. Trenching/Boring—Depth, Clearance OPS 308 SAT JAt least 24" deep OPS 322 3. Bedding/Backfill OPS 308 SAT Observed bedding with sand on SF 418 902 E Logan St 4. Pipe Installation(Tracer Wire) OPS 308 SAT 14 gauge in open trench OPS 322 5. Valve Installation OPS 703 N/A 6. Coating Condition OPS 401 N/A OPS 402 OPS 403 7. Manuals—Field Procedures, O & M SAT IGC procedures followed 8. Testing—Pressure, Duration, Type OPS 505 N/A Did not observe 9. OQ Qualifications OPS 800 SAT Verified 10. Casing Seal/Installation OPS 325 N/A 11. Service Line Installation OPS 302 SAT 12. Tie-In/Hot Tapping OPS 600 N/A 13. Meter Location/Regulator Testing OPS 302 SAT 3 feet away from electrical 14. Equipment Calibration Verification OPS 501 SAT Verified 15. EFV Installation OPS 301 SAT EFV 1200 16. MAOP OPS 602 N/A OPS 606 OPS 900 OPS 1000 17. Purge OPS 603 N/A 18. Safety Equipment SF 418 SAT Fire extinguisher and JSA SF 422 19. Abandonment OPS 607 N/A IPUC Form 4 Rev.12/08/2025 IPUC Construction Inspection 20. Line Locating OPS 611 SAT Hand dig to locate main. 21. Plastic Pipe OPS 307 SAT Observed '/" butt fusion -Joiner(s) Qualified OPS 309 Observed 2" electrofusion - Fusion Tools OPS 325 - Squeezing OPS 800 - Heat Plate - Joining Procedure 22. Steel Pipe OPS 200 N/A -Welder(s) Qualified OPS 201 Pipe/Coating—Inspected/Repaired OPS 202 - Cathodic Protection OPS 306 -Non-Destructive Testing OPS 401 - Welding Procedures OPS 407 - Removal of asbestos wrap OPS 402 - Exothermic Welding OPS 403 Additional Comments: Observations included (902 E Logan St, Boise, ID): Safety equipment, JSA, valid dig ticket, verified operator qualifications, verified equipment calibration, correct trench depth, verified proper rollback of completed 3/4"butt fusions, observed butt fusion process, observed sidewall electrofusion process, EFV 1200 installation, tracer wire and bedding with sand. Observations included(904 E Logan St, Boise, ID): Safety equipment, JSA, valid dig ticket, verified operator qualifications, verified equipment calibration, correct trench depth, verified proper rollback of completed 3/4"butt fusions, observed butt fusion process, observed sidewall electrofusion process and EFV 1200 installation. Observations included (906 E Logan St, Boise, ID): Safety equipment, JSA, valid dig ticket, verified operator qualifications, verified equipment calibration, correct trench depth, verified proper rollback of completed 3/4"butt fusions, observed butt fusion process and EFV 1200 installation. All observed procedures were followed in accordance with IGC Operations and Maintenance Manual. Corrective Action Required: ❑ Yes ® No Compliance Letter#: NA Lead Inspector: Galli Date: Reviewer: Brooks Date: 260114 G Signature: Signature: (� IPUC Form 4 Rev.12/08/2025