Loading...
HomeMy WebLinkAboutIntermountain Gas 250311 IPUC Form 1 Boise-Nampa Patrol Inspection IPUC Pipeline Safety Inspection Inspector(s): Galli Date(s): 250311 Company/Owner: Intermountain Gas Company Unit/OPID: 08160 Standard: ® Training: ❑ TIMP/DIMP: ❑ OQ: ❑ Incident: ❑ Damage Prevention: ❑ Drug&Alcohol: ❑ Inspection Days: 1 Inspection Summary March 11, 2025: (1.0 Standard) (Galli 1.0) IPUC inspector Galli conducted a field inspection of Intermountain Gas Companies right of ways, patrols and bridge crossings of main and transmission lines in Star, Middleton, Emmett and Eagle. Multiple anomalies were found that included missing line markers, faded line markers, pipe that is making contact with the canal retaining walls, vegetation and hangers that are making contact with the pipe. 48283-PP-82040 PIPE PATROL CANAL CROSSING W 4TH ST BETWEEN LINCOLN AVE AND S BOISE AVE EMMETT 4" Patrol sitting on retaining wall. Not able to conduct thorough inspection. Unknown condition of the bottom of the pipe. Possible external corrosion and rubbing from vehicular traffic on adjacent bridge. 48283-PP-14179 PIPE PATROL CHERRY LN AND BLACK CANYON CANAL EMMETT 2" Two hangers touching. Maloney post laying on ground. 48363-PP-14100 PIPE PATROL BOISE AVE & MILL SLOUGH MIDDLETON 2" East side maloney post sticker needs to be replaced. Vegetation on westside needs to be trimmed to conduct thorough inspection. Signage partially obscured. 48367-PP-55369 PIPE PATROL HWY 44 - STOFFLE LN TO HWY 16 -NORTH TO DEEP CANYON DR STAR 12" Underground. Multiple maloney posts along right-of-way need replacement stickers 48367-PP-14171 PIPE PATROL STAR RD 12" HWY 44 (W STATE ST) CROSSING STAR 12" Underground. No marker northside of HWY 44 48417-PP-14129 PIPE PATROL LINDER RD & CANAL XING(N.OF ARTESIAN RD) EAGLE 4" Broken 4" PVC pipe next to gas line. Appears the gas line made contact with and broke the PVC pipe. I IPUC Form 1 Rev. 12/11/2024 IPUC Pipeline Safety Inspection 48417-PP-14127 PIPE PATROL N. EAGLE RD SOUTH OF BEACON LIGHT (CANAL) EAGLE 4 "Pipe within 1/2 inch of retaining wall. Recommend remediation to avoid contact with retaining wall in the future. 48417-PP-14128 PIPE PATROL BEACON LIGHT RD & HOLL DR(FARMERS UNION CANAL) EAGLE 2" Needs new sticker on southside line marker 48417-PP-14125 PIPE PATROL BEACON LIGHT RD &N. GLEN STEWART LN EAGLE 4" Can't confirm if the pipe is sitting on the retaining wall. Needs sticker on eastside line marker. 48417-PP-14130 PIPE PATROL BEACON LIGHT& OSPREY RD (CANAL) EAGLE 2" Needs new stickers on line markers 48417-PP-14142 PIPE PATROL ARTESIAN RD & CANAL EAST OF N. LINDER EAGLE 4" Needs new sticker on line marker 48417-PP-14855 PIPE PATROL BEACON LIGHT RD EAST OF EQUESTRIAN(CANAL) EAGLE 4" Needs new stickers on line markers 48417-PP-14133 PIPE PATROL N. LINDER RD S. OF ARTESIAN RD MERIDIAN 4" Needs line marker on southside An exit interview was sent to IGC compliance personnel with a list of all discrepancies. Per IGC Compliance personnel work orders will be created for all discrepancies. Corrective Action Required: ❑ Yes ® No Compliance Letter#: NA Follow Up Required: ❑ Yes ® No By Date: N/A Lead Inspector: Galli Date: Reviewer: Brooks Date: 250311 b Signature: Signature: 0��9 IPUC Form 1 Rev. 12/11/2024