HomeMy WebLinkAboutIntermountain Gas 250311 IPUC Form 1 Boise-Nampa Patrol Inspection IPUC Pipeline Safety Inspection
Inspector(s): Galli Date(s): 250311
Company/Owner: Intermountain Gas Company Unit/OPID: 08160
Standard: ® Training: ❑ TIMP/DIMP: ❑ OQ: ❑
Incident: ❑ Damage Prevention: ❑ Drug&Alcohol: ❑ Inspection Days: 1
Inspection Summary
March 11, 2025: (1.0 Standard) (Galli 1.0)
IPUC inspector Galli conducted a field inspection of Intermountain Gas Companies right of ways, patrols
and bridge crossings of main and transmission lines in Star, Middleton, Emmett and Eagle. Multiple
anomalies were found that included missing line markers, faded line markers, pipe that is making contact
with the canal retaining walls, vegetation and hangers that are making contact with the pipe.
48283-PP-82040
PIPE PATROL CANAL CROSSING W 4TH ST BETWEEN LINCOLN AVE AND S BOISE AVE
EMMETT 4"
Patrol sitting on retaining wall. Not able to conduct thorough inspection. Unknown condition of the
bottom of the pipe. Possible external corrosion and rubbing from vehicular traffic on adjacent bridge.
48283-PP-14179
PIPE PATROL CHERRY LN AND BLACK CANYON CANAL EMMETT 2"
Two hangers touching. Maloney post laying on ground.
48363-PP-14100
PIPE PATROL BOISE AVE & MILL SLOUGH MIDDLETON 2"
East side maloney post sticker needs to be replaced. Vegetation on westside needs to be trimmed to
conduct thorough inspection. Signage partially obscured.
48367-PP-55369
PIPE PATROL HWY 44 - STOFFLE LN TO HWY 16 -NORTH TO DEEP CANYON DR STAR 12"
Underground. Multiple maloney posts along right-of-way need replacement stickers
48367-PP-14171
PIPE PATROL STAR RD 12" HWY 44 (W STATE ST) CROSSING STAR 12"
Underground. No marker northside of HWY 44
48417-PP-14129
PIPE PATROL LINDER RD & CANAL XING(N.OF ARTESIAN RD) EAGLE 4"
Broken 4" PVC pipe next to gas line. Appears the gas line made contact with and broke the PVC pipe.
I
IPUC Form 1 Rev. 12/11/2024
IPUC Pipeline Safety Inspection
48417-PP-14127
PIPE PATROL N. EAGLE RD SOUTH OF BEACON LIGHT (CANAL) EAGLE 4
"Pipe within 1/2 inch of retaining wall. Recommend remediation to avoid contact with retaining wall in
the future.
48417-PP-14128 PIPE PATROL BEACON LIGHT RD & HOLL DR(FARMERS UNION CANAL)
EAGLE 2"
Needs new sticker on southside line marker
48417-PP-14125
PIPE PATROL BEACON LIGHT RD &N. GLEN STEWART LN EAGLE 4"
Can't confirm if the pipe is sitting on the retaining wall. Needs sticker on eastside line marker.
48417-PP-14130
PIPE PATROL BEACON LIGHT& OSPREY RD (CANAL) EAGLE 2"
Needs new stickers on line markers
48417-PP-14142
PIPE PATROL ARTESIAN RD & CANAL EAST OF N. LINDER EAGLE 4"
Needs new sticker on line marker
48417-PP-14855
PIPE PATROL BEACON LIGHT RD EAST OF EQUESTRIAN(CANAL) EAGLE 4"
Needs new stickers on line markers
48417-PP-14133
PIPE PATROL N. LINDER RD S. OF ARTESIAN RD MERIDIAN 4"
Needs line marker on southside
An exit interview was sent to IGC compliance personnel with a list of all discrepancies. Per IGC
Compliance personnel work orders will be created for all discrepancies.
Corrective Action Required: ❑ Yes ® No Compliance Letter#: NA
Follow Up Required: ❑ Yes ® No By Date: N/A
Lead Inspector: Galli Date: Reviewer: Brooks Date:
250311 b
Signature: Signature: 0��9
IPUC Form 1 Rev. 12/11/2024