Avista 250422 Deary Construction
IPUC Construction Inspection Inspector(s): Perkins Date(s): 250422 Company/Owner: Avista Utilities Unit/OPID: 31232 Address: V Ave and Line St City/District: Deary Contractor/Job #: W/O 1036379846 Foreman: Operator Supervisor: Jake Nielsen On-Site: N Job Description: Lower 2" main that became exposed System Type: © GD due to erosion One-Call Ticket: 2025143232 Total Inspection Days: 1 Tasks: Procedure# Rating Comments 1. Materials-Handling, Storage, Labeling 3.12-3.13 SAT 2. Trenching/Boring-Depth, Clearance 3.15 N/A 3. Bedding/Backfill 3.15 SAT Bedded/backfilled with sand,then gas tape, put fabric on top, 3" basalt rock, and topped with road mix 4. Pipe Installation(Tracer Wire) 3.13 N/A 5. Valve Installation 2.14 N/A 6. Coating Condition 2.12 SAT Operator did exposed pipe report 7. Manuals-Field Procedures, O & M 1.4 SAT 8. Testing-Pressure, Duration, Type 2.12-13/3.18 N/A 9. OQ Qualifications 4.31 SAT In file 10. Casing Seal/Installation 3.42 N/A 11. Service Line Installation 3.16 N/A 12. Tie-In/Hot Tapping 3.32 N/A 13. Meter Location/Regulator Testing 2.22 N/A 14. Equipment Calibration Verification 5.11,14,21 N/A 15. EFV Installation 3.16 N/A 16. MAOP 4.15 N/A 17. Purge 3.17 N/A 18. Safety Equipment GESH 4 SAT Extinguisher 19. Abandonment 5.16 N/A 20. Line Locating 4.13 SAT 21. Plastic Pipe 3.23-25 N/A - Joiner(s) Qualified - Fusion Tools IPUC Form 4 Rev. 12/11/2024 IPUC Construction Inspection - Heat Plate - Joining Procedure 22. Steel Pine N/A - Welder(s) Qualified 3.22 Pipe/Coating—Inspected/Repaired 2.12 - Cathodic Protection 2.32 -Non-Destructive Testing 3.12 - Welding Procedures - Removal of asbestos wrap - Exothermic Welding Additional Comments: Approximately one week ago, Sunrise Engineering conducted a leak survey in Deary, Idaho and identified an exposed 2-inch main gas line caused by water erosion. The issue was promptly reported to Avista, who subsequently issued a work order to address and repair the problem. Avista's Pullman crew identified the exposed 2-inch main and excavated approximately 25 feet in both directions from the point of exposure. An exposed pipe report was completed prior to any repairs. The pipe was lowered by 14 inches. A 1-foot layer of sand was placed as bedding and another I-foot layer as cover. Gas tape was laid over the sand, followed by an impermeable fabric spanning the length of the trench. A 1-foot layer of 3"basalt rock was then added, topped with road mix and compacted using a thumper to solidify the trench. Corrective Action Required: ❑ Yes ® No Compliance Letter#: NA Lead Inspector: Perkins Date: Reviewer: Brooks Date: 250422 Signature:eZ Signature: . IPUC Form 4 Rev.12/11/2024