Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Intermountain Gas 250407 Twin Falls Construction
IPUC Construction Inspection Inspector(s): Perkins Date(s): 7 Apr 2025 Company/Owner: Intermountain Gas Company (IGC)/ Unit/OPID: 8160 KV Utilities Address: 312 Walnut St City/District: Twin Falls Contractor/Job#: W012086040 Foreman: Operator Supervisor: T. Anderson Job Description: %" Service install System Type: © GD ❑ GT ❑ GG One-Call Ticket: 2025142578 Total Inspection Days: 1.0 Tasks: Procedure# Rating Comments 1. Materials—Handling, Storage, Labeling OPS 11 SAT 2. Trenching/Boring—Depth, Clearance OPS 308 SAT OPS 322 3. Bedding/Backfill OPS 308 N/A SF 418 4. Pipe Installation(Tracer Wire) OPS 308 SAT OPS 322 5. Valve Installation OPS 703 N/A 6. Coating Condition OPS 401 SAT OPS 403 7. Manuals—Field Procedures, O & M SAT 8. Testing—Pressure, Duration, Type OPS 505 N/A 9. OQ Qualifications OPS 800 SAT 10. Casing Seal/Installation OPS 325 N/A 11. Service Line Installation OPS 302 SAT 12. Tie-In/Hot Tapping OPS 600 N/A 13. Meter Location/Regulator Testing OPS 302 N/A 14. Equipment Calibration Verification OPS 501 SAT Dates in file 15. EFV Installation OPS 301 SAT 1200 EFV 16. MAOP OPS 602 N/A OPS 606 OPS 900 OPS 1000 17. Purge OPS 603 N/A 18. Safety Equipment SF 418 SAT SF 422 19. Abandonment OPS 607 N/A 20. Line Locating OPS 611 SAT IPUC Form 4 Rev.12/10/2024 IPUC Construction Inspection 21. Plastic Pipe OPS 307 SAT Fusing& Stab fittings - Joiner(s) Qualified OPS 309 - Fusion Tools OPS 325 - Squeezing OPS 800 _ - Heat Plate - Joining Procedure 22. Steel Pipe OPS 200 SAT Welded on 3/" tapping tee - Welder(s) Qualified OPS 201 Pipe/Coating—Inspected/Repaired OPS 202 - Cathodic Protection OPS 306 - Non-Destructive Testing OPS 401 - Welding Procedures OPS 407 - Removal of asbestos wrap OPS 402 - Exothermic Welding OPS 403 Additional Comments: Address: 321 Walnut St, Twin Fals, Idaho Installed 88 ft of 3/" MDPE service from the steel main in the alley to the meter location. Observations Included: Line locating, boring, trenching, stab fittings, fusing, EFV installation, safety equipment, tracer wire, U/T for wall thickness, welding of 3/"tapping tee, verification of OQ records and questioned bore operator on rest times after doing pullback of service line. Corrective Action Required: ❑ Yes ® No Compliance Letter#: Lead Inspector: Perkins Date: Reviewer: Brooks Date: 250407 Signature: / Signature: 0 f�'q IPUC Form 4 Rm 12/10/2024