HomeMy WebLinkAboutIntermountain Gas 250317 Weiser Construction IPUC Construction Inspection Inspector(s): Perkins Date(s): 17 March 2025 Company/Owner: Intermountain Gas Company(IGC) Unit/OPID: 8160 Address: 1355/1365 Crescent St (1375 Crescent IGC) City/District: Weiser Contractor/Job: W012044642, Foreman: Operator Supervisor: None W012044617 C. Zimmerman Job Description: %" Services System Type: ® GD ❑ GT ❑ GG One-Call Ticket: 2025110615, 2025102653 Total Inspection Days: 1.0 Tasks: Procedure# Rating Comments 1. Materials—Handling, Storage, Labeling OPS 11 SAT 2. Trenching/Boring—Depth, Clearance OPS 308 SAT 24" OPS 322 3. Bedding/Backfill OPS 308 SAT Native soil SF 418 4. Pipe Installation(Tracer Wire) OPS 308 SAT OPS 322 5. Valve Installation OPS 703 N/A 6. Coating Condition OPS 401 N/A OPS 403 7. Manuals—Field Procedures, O & M SAT 8. Testing—Pressure, Duration, Type OPS 505 SAT 100 PSI-15 Min 9. OQ Qualifications OPS 800 SAT 10. Casing Seal/Installation OPS 325 N/A 11. Service Line Installation OPS 302 SAT 12. Tie-In/Hot Tapping OPS 600 N/A 13. Meter Location/Regulator Testing OPS 302 N/A 14. Equipment Calibration Verification OPS 501 SAT Dates in file 15. EFV Installation OPS 301 SAT 1200 16. MAOP OPS 602 N/A OPS 606 OPS 900 OPS 1000 17. Purge OPS 603 SAT 18. Safety Equipment SF 418 SAT SF 422 19. Abandonment OPS 607 N/A 20. Line Locating OPS 611 SAT IPUC Form 4 Rev. 12/10/2024 IPUC Construction Inspection 21. Plastic Pine OPS 307 SAT Stab fittings - Joiner(s) Qualified OPS 309 - Fusion Tools OPS 325 - Squeezing OPS 800 - Heat Plate - Joining Procedure 22. Steel Pine OPS 200 N/A - Welder(s) Qualified OPS 201 Pipe/Coating—Inspected/Repaired OPS 202 - Cathodic Protection OPS 306 -Non-Destructive Testing OPS 401 - Welding Procedures OPS 407 - Removal of asbestos wrap OPS 402 - Exothermic Welding OPS 403 Additional Comments: Address: 1355/1365 Crescent St Weiser, Idaho Observations: • Safety equipment was verified • Conducted pressure test, purging, and verification of OQ records. • Performed Stabbing, EFV installation, tracer wire placement, trenching, bedding, and backfilling. • Checked for gas quality to ensure compliance and line located after installation • Quizzed the employee on squeeze/release times. Address: 1375 Crescent St Weiser, Idaho Upon arriving at the subdivision, I detected the distinct smell of a gas leak. I proceeded to spray the meter bar on the house and identified a leak at the union connecting the riser to the meter bar. I immediately contacted the IGC leak line, and a service technician from the Nampa district promptly responded to repair the issue. Corrective Action Required: ❑ Yes ® No Compliance Letter#: Lead Inspector: ins Date: Reviewer: Brooks �, Date: 250317 Signature: Signature: 0_� IPUC Form 4 Rev. 12/10/2024