HomeMy WebLinkAboutIntermountain Gas 241029 Garden City Construction IPUC Construction Inspection Inspector(s): Galli Date(s): 10/29/2024 Company/Owner: Unit/OPID: 08160 Intermountain Gas Company IGC Address: 5663 N Glenwood City/District: Garden City Contractor/Job#: Foreman: Employees: See Job List 421-006724 Jesus Garcia Job Description: V Service Line(s) System Type: ® Distribution ❑ Transmission from 2" Main Operator Supervisor: Will One-Call Ticket: 2024433075 On-Site: N Total Inspection Days: 1.0 Tasks: Rating Critical Procedure# Comments 1. Materials—Handling, Storage, SAT OPS l l Labeling 2. Trenching/Boring—Depth, Clearance SAT OPS 308 Bore crew 24 inches OPS 322 3. Bedding/Backfill SAT OPS 308 Sand used SF 418 4. Pipe Installation(Tracer Wire) SAT OPS 308 14-gauge OPS 322 5. Valve Installation N/A OPS 703 6. Coating Condition N/A OPS 401 OPS 403 7. Manuals—Field Procedures, O & M SAT 8. Testing—Pressure, Duration, Type SAT OPS 505 96 psi for 15 minutes 9. OQ Qualifications SAT OPS 800 Verified 10. Casing Seal/Installation SAT OPS 325 Sleeve V through 2"PE 11. Service Line Installation SAT OPS 302 12. Tie-In/Hot Tapping N/A OPS 600 13. Meter Location/Regulator Testing SAT OPS 302 14. Equipment Calibration Verification SAT OPS 501 Verified 15. EFV Installation SAT OPS 301 EFV 1200 16. MAOP N/A OPS 602 OPS 606 OPS 900 OPS 1000 17. Pure SAT OPS 603 Cleani purge 18. Safety Equipment SAT SF 418 Fire extinguisher SF 422 19. Abandonment N/A OPS 607 20. Line Locating SAT OPS 611 Hand dig near main Visible Markings IPUC Form 4 Rev. 12/21/2023 IPUC Construction Inspection 21. Plastic Pipe SAT OPS 307 Saddle Tee - Joiner(s) Qualified OPS 309 Manual Butt Fusion - Fusion Tools OPS 324 - Heat Plate OPS 325 - Joining Procedure OPS 800 -Squeeze Off 22. Steel Pipe N/A OPS 200 - Welder(s) Qualified OPS 201 Pipe/Coating—Inspected/Repaired OPS 202 - Cathodic Protection OPS 306 -Non-Destructive Testing OPS 401 - Welding Procedures OPS 407 - Removal of asbestos wrap OPS 402 - Exothermic Welding OPS 403 4800 Additional Comments: Address: 5663 N Glenwood, Garden City, ID Observations Included: Saw cutting, line locating(hand dig near main), boring, pullback, sleeved a 3/" PE service line through a section of 2"PE pipe, correct trench depth, safety equipment, verification OQ records, verification equipment calibrations, valid dig ticket, tracer wire install, mechanical fittings (saddle tee), manual butt fusion, EFV 1200 installation, successful pressure test at 96 psi for 15 minutes, cleaning purge, bedding and backfill. All observed procedures were completed in accordance with IGC Operations and Maintenance Manual. Corrective Action Required: Yes No X Follow-up Required: By Date: Yes No X Inspector(Lead): Date: 10/29/2024 Galli Reviewer: 'I Brooks Date: 10.3�• IPUC Form 4 Rev. 12/21/2023