Loading...
HomeMy WebLinkAboutIntermountain Gas 210802-04 Idaho Falls Field Idaho PUC Pipeline Safety Inspection Summary Inspector(s): Ulmer/Brooks Date(s): z a aug 2o2i Company/Owner: Intermountain Gas Company Unit/OPID: I Idaho Falls Inspection Type &Time (1 day, 0.5 day) I Total Inspection Days:1 8 Standard: 7.5 Construction: Training: = (T)(D)Integrity Management: Incident: M/M: Follow-up: OQ: 0.5 Damage Prevention: D&A: Inspection Summary Audit consisted of inspecting field installed equipment and operator qualification for the Idaho Falls, Idaho inspection units. Records and procedures for all Idaho Intermountain Gas Units were inspected in March 2021 at the Intermountain Gas Company(IGC) headquarters in Boise, Idaho. August 2-4,2021: (5.5 Standard, .5 OQ) Traveled to Idaho Falls and met with IGC company representatives in the Idaho Falls district office for in-brief and to begin field audit. Regulator Stations 70106, 70108, 70111, 70112, 70113, 70115, 70116, 70118, 70126, 70127, 70128, 70129, 70130, 70131, 70132, 70133, 70134, 70136, 70137, 70138, 70142, 70144, 70146 and 70147 were inspected for proper operating parameters, regulator lock-up, relief device operation, cathodic protection pipe-to-soil readings, pipe-to soil interface wrap protection, station warning signs and right-of-way clearances. Nine casing-to-carrier isolation checks, one cathodic protection rectifier,four pipeline patrols, and twenty-one emergency isolation valves were checked for proper operation. An IPUC Form 3 (exit interview) was performed following the district inspection with Will Lindsey(Pipeline Safety Specialist) of Intermountain Gas Company. Observations: Reg Station: 70108 relief had a low CP read (-0.77) Reg Stations: not plumbed for lock-up 701128 and 70130 Reg Station: 70106 Primary had a leak on the loading element Reg Stations: 70115 and 70130 reliefs failed to reset,fixed on the spot Casing: 789-00-301 had a low CP read (-0.74) Casing: 773-01-102 No sticker/marker, fixed on the spot Patrol: PP-787-001 No sticker/marker,fixed on the spot Patrol: ACP-789-001 No marking/signage IPUC Form 1 Idaho PUC Pipeline Safety Inspection Summary Patrol: ACP-775-002 No sticker/marker,fixed on the spot Aug 5,2021: (2.0 Standard) Traveled back to Boise, completed forms and typed report. Attached: IPUC Form 1, Inspection Summary IPUC Form 3, Exit Interview IPUC Field Equipment Status Worksheets PHMSA Form 2, Standard Inspection of a Gas Distribution Operator(IA Version) PHMSA Form 15 OQ Field Corrective Action Required: Yes X Na Follow-up Required: b (date . Nov 2021 Yes X No Inspector (Lead): Date: Reviewer: Date: IPUC Form 1