HomeMy WebLinkAboutIntermountain Gas 231211 Eagle Construction IPUC Construction Inspection
Inspector(s): Galli Date(s): 12/11/2023
Company/Owner: Unit/OPID: 08160
Intermountain Gas Company(IGC
Address: 6742 W Piaffe St City/District: Eagle
Contractor/Job #: Foreman: Employee: See Lineup
15455-417 Librado Ruiz
Job Description: 1/4" Service Lines Circle: Distribution
Operator Supervisor: Joe One-Call Ticket: 461116
On-Site: Yes
Total Inspection Days: .5
Tasks: Rating Critical Procedure # Comments
1. Materials—Handling, Storage, SAT OPS 11
Labeling
2. Trenching/Boring—Depth, Clearance SAT OPS 308
OPS 322
3. Bedding/Backfill SAT OPS 308 Sand Used
SF 418
4. Pipe Installation(Tracer Wire) SAT OPS 308
OPS 322
5. Valve Installation N/A OPS 703
6. Coating Condition N/A OPS 401
OPS 403
7. Manuals—Field Procedures, O & M SAT
8. Testing—Pressure, Duration, Type SAT OPS 505 94 PSI for 15 minutes
9. OQ Qualifications SAT OPS 800
10. Casing Seal/Installation N/A OPS 325
11. Service Line Installation N/A OPS 302
12. Tie-In/Hot Tapping N/A OPS 600
13. Meter Location/Regulator Testing SAT OPS 302
14. Equipment Calibration Verification SAT OPS 501 Pyrometer: See pics
Pressure Gauge: See pics
15. EFV Installation SAT OPS 301 EFV 1200
16. MAOP N/A OPS 602
OPS 606
OPS 900
OPS 1000
17. Pure N/A OPS 603
18. Safety Equipment SAT SF 418
SF 422
19. Abandonment N/A I OPS 607
20. Line Locating SAT I OPS 611
IPUC Form 4 Rev. April 2023
I PUC Construction Inspection
21. Plastic Pipe SAT OPS 307
- Joiner(s) Qualified OPS 309
- Fusion Tools OPS 324
- Heat Plate OPS 325
- Joining Procedure OPS 800
22. Steel Pipe N/A OPS 200
- Welder(s) Qualified OPS 201
Pipe/Coating—Inspected/Repaired OPS 202
- Cathodic Protection OPS 306
-Non-Destructive Testing OPS 401
- Welding Procedures OPS 407
- Removal of asbestos wrap OPS 402
- Exothermic Welding OPS 403
4800
Additional Comments:
IPUC inspector Galli observed Dasco, a contractor for IGC install a 1/" service line in Eagle, ID.
Address: 6742 W Piaffe St, Eagle, ID
Observations Include: correct trench depth, safety equipment, tracer wire, verification of equipment
calibrations, successful pressure test, stab fitting(T), squeeze off procedures,bedding with sand and
backfill, line locating and continuity testing. All observed procedures were followed in accordance with
IGC Operations and Maintenance Manual.
Address: 6652 W Piaffe St, Eagle, ID
Observations Include: correct trench depth, line locating�safety equipment, verification of equipment
calibrations, butt fusion and bedding with sand. All observed procedures were followed in accordance
with IGC Operations and Maintenance Manual.
Corrective Action Required: Yes No X
Follow-up Required: By Date: Yes No X
Inspector(Lead): Date: 12/11/2023
Galli
Reviewer: Date: '_
Brooks
IPUC Form 4 Rev. April 2023