HomeMy WebLinkAboutDouglas Pipeline Company 2023 Douglas Integrity Dig - Mt Home Idaho PUC Pipeline Safety Inspection Summary Inspector(s): I Perkins, Galli I Date(s): 9/26/2023 Company/Owner: IDouglas Pipeline Company(DPC) I Unit#/OPID 131442 Inspection Type&Time (1 day, 0.5 day) I Total Inspection Days: 1.5 Standard: I Training: I (T)(D)Integrity Management: 1.5 Incident: Follow-up: I oQ: Damage Prevention: D&A: Inspection Summary IPUC Inspectors Perkins and Galli observed Douglas Pipeline Company(DPC) and Steele Cathodic conduct an integrity/HCA dig on the Idaho Power-Bennett Mountain pipeline in three locations between Highway 20 and the Power plant due to various wildlife holes along the right of way. Steele Cathodic was in the process of composing a report of all pertinent information/observations. Location I (adjacent to old school) -Minor pipe abrasions from excavation that were grinded down and coated with two-part epoxy; wall thickness reading of.55 inches.No signs of wildlife damage were observed. Location 2 (adjacent to dirt road and hwy 20 intersection) -Minor pipe abrasions from excavation that were grinded down and coated with two-part epoxy; wall thickness reading of.57 inches. No signs of wildlife damage were observed. Location 3 - (adjacent to hwy 20 near IGC odorizer) -Minor pipe abrasions from excavation that were grinded down and coated with two-part epoxy; wall thickness reading of.55 inches. No signs of wildlife damage were observed. All sections of daylighted pipe were bedded with sand and backfilled. Relevant photos saved in DPC integrity/HCA dig file. Corrective Action Required: Yes I Nol X Follow-up Required: by (date): Yes I Nol X Inspector (Lead): Date: Perkins "fir' 9/26/2023 Reviewer: Date: Brooks i0'10-�3 IPUC Form 1