HomeMy WebLinkAboutIntermountain Gas 240813 Boise Construction IPUC Construction Inspection Inspector(s): Perkins Date(s): 08/13/2024 Company/Owner: Unit/OPID: 08160 Intermountain Gas Company IGC Address: 5106 W Promise Ln City/District: Boise Contractor/Job# Foreman: Employees: See Job List 115738-425 Rigo Chavarin Job Description: Install '/" Service Line System Type: ® Distribution ❑ Transmission Operator Supervisor: One-Call Ticket: 2024302157 On-Site: N Total Inspection Days: 1.0 Tasks: Rating Critical Procedure# Comments 1. Materials—Handling, Storage, SAT OPS 11 Labeling 2. Trenching/Boring—Depth, Clearance SAT OPS 308 OPS 322 3. Bedding/Backfill SAT OPS 308 SF 418 4. Pipe Installation(Tracer Wire) SAT OPS 308 OPS 322 5. Valve Installation N/A OPS 703 6. Coating Condition N/A OPS 401 OPS 403 7. Manuals—Field Procedures, O & M SAT 8. Testing—Pressure, Duration, Type SAT OPS 505 96 psi 15 minutes 9. OQ Qualifications SAT OPS 800 In folder 10. Casing Seal/Installation N/A OPS 325 11. Service Line Installation SAT OPS 302 12. Tie-In/Hot Tapping N/A OPS 600 13. Meter Location/Regulator Testing N/A OPS 302 14. Equipment Calibration Verification SAT OPS 501 In File 15. EFV Installation SAT OPS 301 16. MAOP N/A OPS 602 OPS 606 OPS 900 OPS 1000 17. Pure SAT OPS 603 18. Safety Equipment SAT SF 418 SF 422 19. Abandonment N/A OPS 607 20. Line Locating SAT OPS 61 P U C Form 4 Rev. 12/21/2023 IPUC Construction Inspection 21. Plastic Pine SAT OPS 307 - Joiner(s) Qualified OPS 309 - Fusion Tools OPS 324 - Heat Plate OPS 325 - Joining Procedure OPS 800 22. Steel Pine N/A OPS 200 - Welder(s) Qualified OPS 201 Pipe/Coating—Inspected/Repaired OPS 202 - Cathodic Protection OPS 306 -Non-Destructive Testing OPS 401 - Welding Procedures OPS 407 - Removal of asbestos wrap OPS 402 - Exothermic Welding OPS 403 4800 Additional Comments: IPUC inspector Perkins observed Das-Co, a contractor for IGC Install 3/" Service Line in Boise, ID. Address: 5106 W Promise Ln Observations Include: Verification of OQ records, fusing, EFV install, stab fitting,pressure testing, tracer wire, line locating, squeezing, trenching, bedding and backfilling. Quizzed employee on squeeze and release times. All observed procedures/manufacturer instructions were followed in accordance with IGC Operations and Maintenance Manual). Upon arrival at the job site, I detected the smell of gas and looked around and could not find it. I called IGC leak line, and they sent service tech Ryan Leser out to investigate. He attempted to locate the leak using a plume locator, bar holed and used a CGI and he determined that there must have been a dead animal in the next door backyard (jungle). Corrective Action Required: Yes No Follow-up Required: By Date: Yes No I X Inspector (Lead): Date: 08/13/2024 Perkins Reviewer: v Brooks *L-L Date: 1W•ty-ac IPUC Form 4 Rev. 12/21/2023