Loading...
HomeMy WebLinkAboutIntermountain Gas 240520-23 Eagle Construction IPUC Construction Inspection Inspector(s): Perkins, Brooks and Galli Date(s): 05/20-23/2024 Company/Owner: Unit/OPID: 08160 Intermountain Gas Company(IGC) Address: Goose Creek Rd/N Horseshoe Bend Rd City/District: Eagle Ada county landfill-RNG Contractor/24NG2000 Foreman: Employees: See Job List Donald Teel Job Description: Install 6" RNG Steel System Type: ❑ Distribution ® Transmission Transmission and interconnect piping Operator Supervisor: One-Call Ticket: 2024191028 On-Site: QCI-Ron Sanders Total Inspection Days: 7 Tasks: Ratip& Critical Procedure# Comments 1. Materials—Handling, Storage, SAT OPS 11 Stringing pipe Labeling 2. Trenching/Boring—Depth, Clearance SAT OPS 308 OPS 322 3. Bedding/Backfill SAT OPS 308 SF 418 4. Pipe Installation(Tracer Wire) SAT OPS 308 6" Steel OPS 322 5. Valve Installation N/A OPS 703 6. Coating Condition SAT OPS 401 Wrapping/Jeeping OPS 403 7. Manuals—Field Procedures, O & M SAT 8. Testing—Pressure, Duration, Type N/A OPS 505 9. OQ Qualifications SAT OPS 800 In folder 10. Casing Seal/Installation N/A OPS 325 11. Service Line Installation N/A OPS 302 12. Tie-In/Hot Tapping N/A OPS 600 13. Meter Location/Regulator Testing N/A OPS 302 14. Equipment Calibration Verification SAT OPS 501 Pyrometer for pre-heat 15. EFV Installation N/A OPS 301 16. MAOP N/A OPS 602 OPS 606 OPS 900 OPS 1000 Purge N/A OPS 603 17. 18. Safety Equipment SAT SF 418 SF 422 19. Abandonment N/A OPS 607 20. Line Locating SAT OPS 611 I P U C Form 4 Rev. 12/21/2023 IPUC Construction Inspection 21. Plastic Pipe N/A OPS 307 - Joiner(s) Qualified OPS 309 -Fusion Tools OPS 324 -Heat Plate OPS 325 - Joining Procedure OPS 800 22. Steel Pipe SAT OPS 200 6" Steel, X-Ray testing - Welder(s) Qualified OPS 201 10%, Pre-heat of weld Pipe/Coating—Inspected/Repaired OPS 202 joints. - Cathodic Protection OPS 306 -Non-Destructive Testing OPS 401 - Welding Procedures OPS 407 - Removal of asbestos wrap OPS 402 - Exothermic Welding OPS 403 4800 Additional Comments: IPUC inspector Perkins/Brooks/Galli observed Das-Co, a contractor for IGC Install 6"Transmission in Eagle, ID. Address: Goose Creek Rd/N Horseshoe Bend Rd, Ada County landfill Observations Include: Verification of OQ records, trenching, welding. pre-heating of welding joint, jeeping, wrapping, bedding, cad-welding with installation of anode, back filling, and pipe stringing. All observed procedures were followed in accordance with IGC Operations and Maintenance Manual. Corrective Action Required: Yes INo X Follow-up Required: By Date: Yes 1. No FX Inspector(Lead: -� Date: 05/23/2024 Perkins Reviewer: Brooks AIL_ Date: IPUC Form 4 Rev. 12/21/2023