HomeMy WebLinkAboutIntermountain Gas 240306.2 Caldwell Construction IPUC Construction Inspection
Inspector(s): Perkins, Galli Date(s): 03/06/2024
Company/Owner: Unit/OPID: 08160
Intermountain Gas Company IGC)
Address: 1609 Lansing Ave City/District: Caldwell
Contractor/Job#: Foreman: Employees: See Job List
050879-413 Bob Schwehrt
Job Description: Install 3/4" Service Line(s) System Type: ® Distribution ❑ Transmission
Operator Supervisor: Zach Williams One-Call Ticket: 2024
On-Site: N
Total Inspection Days: 2.0
Tasks: Rating Critical Procedure# Comments
1. Materials—Handling, Storage, SAT OPS 11
Labeling
2. Trenching/Boring—Depth, Clearance SAT OPS 308
OPS 322
3. Bedding/Backfill SAT OPS 308 Sand
SF 418
4. Pipe Installation(Tracer Wire) SAT OPS 308
OPS 322
5. Valve Installation N/A OPS 703
6. Coating Condition N/A OPS 401
OPS 403
7. Manuals—Field Procedures, O & M SAT
8. Testing—Pressure, Duration, Type SAT OPS 505 95 PSI for 15 Min
9. OQ Qualifications SAT OPS 800 In folder
10. Casing Seal/Installation N/A OPS 325
11. Service Line Installation SAT OPS 302
12. Tie-In/Hot Tapping N/A OPS 600
13. Meter Location/Regulator Testing N/A OPS 302
14. Equipment Calibration Verification SAT OPS 501 All dates in the folder
15. EFV Installation N/A OPS 301
16. MAOP N/A OPS 602
OPS 606
OPS 900
OPS 1000
17. Pure SAT OPS 603
18. Safety Equipment SAT SF 418
SF 422
19. Abandonment N/A OPS 607
20. Line Locating SAT OPS 611
IPUC Form 4 Rev. 12/2v2023
IPUC Construction Inspection
21. Plastic Pine SAT OPS 307
- Joiner(s) Qualified OPS 309
- Fusion Tools OPS 324
-Heat Plate OPS 325
-Joining Procedure OPS 800
22. Steel Pine N/A OPS 200
- Welder(s) Qualified OPS 201
Pipe/Coating—Inspected/Repaired OPS 202
- Cathodic Protection OPS 306
-Non-Destructive Testing OPS 401
- Welding Procedures OPS 407
- Removal of asbestos wrap OPS 402
- Exothermic Welding OPS 403
4800
Additional Comments:
IPUC inspector Perkins and Galli observed an IGC crew repair a 1/2" service line(s) that was bored
through a concrete sewer pipe in Caldwell, ID.
Address: 1609 Lansing Ave, Caldwell, ID
Observations Include: Correct trench depth, safety equipment, verification of OQ records, verification
of equipment calibrations, tracer wire, successful pressure test, mechanical fittings (3/4 to 1/2 inch
reducing continental stab fittings) and backfill. All observed procedures were followed in accordance
with IGC Operations and Maintenance Manual.
Corrective Action Required: Yes No X
Follow-up Required: By Date: Yes f No X
Inspector(Lead): fig -,
Date: 03/06/2024
Perkins
Reviewer:
Brooks /
Date: 2-`7 a4
P U C Form 4 Rev. 12i21/2023