HomeMy WebLinkAboutIntermountain Gas 240205-07 Boise Construction IPUC Construction Inspection Inspector(s): Perkins Date(s): 02/05-07/2024 Company/Owner: Unit/OPID: 08160 Intermountain Gas Company(IGC) Address: 19255 N McCleod Wy City/District: Boise Contractor/Job#: Foreman: Employees: See Job List 425-117917 German Gomez Job Description: Install 484' of 2" Service line off System Type: ® Distribution ❑ Transmission of 4" main Operator Supervisor: Jason One-Call Ticket: 2024050604 On-Site: Y Total Inspection Days: 2.5 Tasks: Rating Critical Procedure# Comments 1. Materials—Handling, Storage, SAT OPS 11 Labeling 2. Trenching/Boring—Depth, Clearance SAT OPS 308 OPS 322 3. Bedding/Backfill SAT OPS 308 SF 418 4. Pipe Installation(Tracer Wire) SAT OPS 308 OPS 322 5. Valve Installation N/A OPS 703 6. Coating Condition N/A OPS 401 OPS 403 7. Manuals—Field Procedures, O & M SAT 8. Testing—Pressure, Duration, Type SAT OPS 505 94 PSI for 30 Minutes 9. OQ Qualifications SAT OPS 800 In folder 10. Casio Seal/Installation N/A OPS 325 11. Service Line Installation SAT OPS 302 12. Tie-In/Hot Tapping SAT OPS 600 Electro fusion tee 13. Meter Location/Regulator Testing N/A OPS 302 14. Equipment Calibration Verification SAT OPS 501 All dates in the folder 15. EFV Installation SAT OPS 301 5500 16. MAOP N/A OPS 602 OPS 606 OPS 900 OPS 1000 17. Purge SAT OPS 603 18. Safety Equipment SAT SF 418 SF 422 19. Abandonment N/A OPS 607 20. Line Locating SAT OPS 611 IPUC Form 4 Rev. 12/21/2023 IPUC Construction Inspection 21. Plastic Pipe SAT OPS 307 - Joiner(s) Qualified OPS 309 -Fusion Tools OPS 324 - Heat Plate OPS 325 - Joining Procedure OPS 800 22. Stcel Pipe N/A OPS 200 - Welder(s) Qualified OPS 201 Pipe/Coating—Inspected/Repaired OPS 202 - Cathodic Protection OPS 306 -Non-Destructive Testing OPS 401 - Welding Procedures OPS 407 - Removal of asbestos wrap OPS 402 - Exothermic Welding OPS 403 4800 Additional Comments: IPUC inspector Perkins observed Das-Co, a contractor for IGC installing 450' of 2" service line off of main in Boise, ID. Address: 19255 N McCleod Wy Observations Include: Safety equipment, trenching, boring, pressure test, purging, verification of OQ records,bedding,back-filling, locating all utilities, and fusing. All procedures were followed in accordance with IGC Operations and Maintenance Manual. Corrective Action Required: Yes No X Follow-up Required: By Date: , Yes No X Inspector (Lead): Date: Perkino�<e 2/07/2024 Reviewer: il-- Date: a-�S•�y Brooks IPUC Form 4 Re,. 12/21/2023