Loading...
HomeMy WebLinkAboutIntermountain Gas 240205 Boise Construction IPUC Construction Inspection Inspector(s): Galli,Brooks Date(s): 02/05/2024 Company/Owner: Unit/OPID: 08160 Intermountain Gas Compaq (IGC) Address: 12590 W Franklin Road City/District: Boise Contractor/Job #: Foreman: Employees: See Job List 117969-425 Jacob Pritt Job Description: Install %" Service Line System Type: n Distribution ❑ Transmission Operator Supervisor: Jason One-Call Ticket: 040654 On-Site: N Total Inspection Days: 2.0 1 Tasks: Rating Critical Procedure# Comments 1. Materials—Handling, Storage, SAT OPS 11 Labeling 2. Trenching/Boring—Depth, Clearance SAT OPS 308 OPS 322 3. Bedding/Backfill SAT OPS 308 Sand used SF 418 4. Pipe Installation(Tracer Wire) SAT OPS 308 OPS 322 5. Valve Installation N/A OPS 703 6. Coating Condition N/A OPS 401 OPS 403 7. Manuals—Field Procedures, O &M SAT 8. Testing—Pressure, Duration, Type SAT OPS 505 96 psi for 15 min 9. OQ Qualifications SAT OPS 800 10. Casing Seal/Installation N/A OPS 325 11. Service Line Installation SAT OPS 302 12. Tie-In/Hot Tapping N/A OPS 600 13. Meter Location/Regulator Testing SAT OPS 302 14. Equipment Calibration Verification SAT OPS 501 Pyrometer: 1/8/2025 Pres. Gauge: 1/4/2025 15. EFV Installation SAT OPS 301 EFV pre-installed on stub 16. MAOP N/A OPS 602 OPS 606 OPS 900 OPS 1000 17. Pure N/A OPS 603 18. Safety Equipment SAT SF 418 SF 422 19. Abandonment N/A OPS 607 IPUC Form 4 Rev. 12/21/2023 IPUC Construction Inspection 20. Line Locating SAT OPS 611 21. Plastic Pine SAT OPS 307 - Joiner(s) Qualified OPS 309 - Fusion Tools OPS 324 - Heat Plate OPS 325 - Joining Procedure OPS 800 22. Steel Pine N/A OPS 200 -Welder(s) Qualified OPS 201 Pipe/Coating—Inspected/Repaired OPS 202 - Cathodic Protection OPS 306 -Non-Destructive Testing OPS 401 - Welding Procedures OPS 407 - Removal of asbestos wrap OPS 402 - Exothermic Welding OPS 403 4800 Additional Comments: IPUC inspector Galli and Brooks observed Dasco, a contractor for IGC install a V service line from a 2" stub with a reducing stab fitting in Boise, ID. Address: 12590 W Franklin Road, Boise, ID Observations Include: correct trench depth, line locating, safety equipment, verification of OQ records, verification of equipment calibrations, tracer wire, EFV pre-installed on the stub, butt fusion, stab fittings (2"to V reducer),bedding and backfill. Quizzed employee on applicable AOCs of squeeze off. Dasco crew needed to cut out a section of pipe that was damaged during the squeeze off. All procedures were followed in accordance with IGC Operations and Maintenance Manual. Corrective Action Required: Yes No X Follow-up Required: By Date: Yes No X Inspector (Lead): Date: 02/05/2024 Galli Reviewer: / 'I Date: Brooks IPUC Form 4 Rev. 12/21/2023