Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Intermountain Gas 240103 Boise Construction
IPUC Construction Inspection Inspector(s): Perkins Date(s): 01/03/2024 Company/Owner: Unit/OPID: 08160 Intermountain Gas Company (IGC) Address: 1801 N 18th St City/District: Boise Contractor/Job#: Foreman: Employees: See Job List 02267-425 German Gomez Job Description: Abandonment of service line System Type: ® Distribution ❑ Transmission Operator Supervisor: Jason One-Call Ticket: 50190 On-Site: N Total Inspection Days: 1 Tasks: Rating Critical Procedure # Comments 1. Materials—Handling, Storage, SAT OPS 11 Labeling 2. Trenching/Boring—Depth, Clearance SAT OPS 308 OPS 322 3. Bedding/Backfill N/A OPS 308 SF 418 4. Pipe Installation(Tracer Wire) N/A OPS 308 OPS 322 5. Valve Installation N/A OPS 703 6. Coating Condition N/A OPS 401 OPS 403 7. Manuals—Field Procedures, O & M SAT 8. Testing—Pressure, Duration, Type N/A OPS 505 9. OQ Qualifications SAT OPS 800 10. Casio Seal/Installation N/A OPS 325 11. Service Line Installation N/A OPS 302 12. Tie-In/Hot Tapping N/A OPS 600 13. Meter Location/Re lator Testin N/A OPS 302 14. Equipment Calibration Verification N/A OPS 501 15. EFV Installation N/A OPS 301 16. MAOP N/A OPS 602 OPS 606 OPS 900 OPS 1000 17. Pure SAT OPS 603 __Purged abandoned line 18. Safety Equipment SAT SF 418 SF 422 19. Abandonment SAT OPS 607 Abandon 3/4" ald 1-a 20. Line Locating SAT OPS 611 IPUC Form 4 Rev.12/2v2023 IPUC Construction Inspection 21. Plastic Pipe SAT OPS 307 - Joiner(s) Qualified OPS 309 - Fusion Tools OPS 324 - Heat Plate OPS 325 - Joining Procedure OPS 800 22. Steel Pipe N/A OPS 200 - Welder(s) Qualified OPS 201 Pipe/Coating—Inspected/Repaired OPS 202 - Cathodic Protection OPS 306 -Non-Destructive Testing OPS 401 - Welding Procedures OPS 407 - Removal of asbestos wrap OPS 402 - Exothermic Welding OPS 403 4800 Additional Comments: IPUC inspector Perkins observed Das-Co, a contractor for IGC install a 3/4' service line in Boise, ID. Address: 1801N 18t' St, Boise Idaho Observations Include: potholing, line locating, safety equipment, verification of OQ records, install repair tapping tee over top of aldyl-a tee (IGC),purging of abandoned line, filled both ends with spray foam,back-filling, removal of old house meter. All procedures were followed in accordance with IGC Operations and Maintenance Manual. Corrective Action Required: Yes No X Follow-up Required: By Date: Yes No X Inspector(Lead): �- Date: Perkins 1/3/2024 Reviewer: _ Date: I_8-0- Brooks IPUC Form 4 Rev. 12/2v2023