Loading...
HomeMy WebLinkAboutDEUWI GD 2020 NOTICE:This report is required by 49 CFR Part 191. Failure to report can result in a civil penalty not to exceed 100,000 for each violation for each day that such violation persists except that the maximum civil OMB NO:2137-0629 penalty shall not exceed$1,000,000 as provided in 49 USC 60122. EXPIRATION DATE:10/31/2021 Initial Date 03/11/2021 fa Submitted: U.S Department of Transportation Form Type: INITIAL Pipeline and Hazardous Materials Safety Administration Date Submitted: ANNUAL REPORT FOR CALENDAR YEAR 2020 GAS DISTRIBUTION SYSTEM A federal agency may not conduct or sponsor,and a person is not required to respond to,nor shall a person be subject to a penalty for failure to comply with a collection of information subject to the requirements of the Paperwork Reduction Act unless that collection of information displays a current valid OMB Control Number. The OMB Control Number for this information collection is 2137-0629. Public reporting for this collection of information is estimated to be approximately 16 hours per response,including the time for reviewing instructions,gathering the data needed,and completing and reviewing the collection of information. All responses to this collection of information are mandatory. Send comments regarding this burden estimate or any other aspect of this collection of information,including suggestions for reducing this burden to:Information Collection Clearance Officer,PHMSA,Office of Pipeline Safety(PHP-30)1200 New Jersey Avenue,SE,Washington,D.C.20590. Important: Please read the separate instructions for completing this form before you begin. They clarify the information requested and provide specific examples. /f you do not have a copy of the instructions,you can obtain one from the PHMSA Pipeline Safety Community Web Page at http://www. phmsa.dot.gov/p>�eline/library/forms. PART A-OPERATOR INFORMATION (DOT use only) 20210966-42397 1. Name of Operator DOMINION ENERGY UTAH/WYOMING/IDAHO 2. LOCATION OF OFFICE(WHERE ADDITIONAL INFORMATION MAY BE OBTAINED) 2a.Street Address 333 SOUTH STATE STREET P.O. BOX 45360 2b.City and County SALT LAKE CITY 2c.State UT 2d.Zip Code 84145 3.OPERATOR'S 5 DIGIT IDENTIFICATION NUMBER 12876 4. HEADQUARTERS NAME&ADDRESS 4a.Street Address 333 SOUTH STATE STREET 4b.City and County SALT LAKE CITY 4c.State UT 4d.Zip Code 84111 5.STATE IN WHICH SYSTEM OPERATES ID 6.THIS REPORT PERTAINS TO THE FOLLOWING COMMODITY GROUP(Select Commodity Group based on the predominant gas carried and complete the report for that Commodity Group.File a separate report for each Commodity Group included in this OPID.) Natural Gas 7.THIS REPORT PERTAINS TO THE FOLLOWING TYPE OF OPERATOR(Select Type of 0peratorbased on the structure of the company included in this OPID for which this report is being submitted.): Investor Owned PART B-SYSTEM DESCRIPTION 1.GENERAL STEEL UNPROTECTED CATHODICALLY CAST/ DUCTILE RECONDITION SYSTEM PROTECTED PLASTIC WROUGHT IRON COPPER OTHER ED TOTAL IRON CAST IRON BARE COATED BARE COATED MILES OF 1.564 52.112 0 0 0 0 0 53.676 MAIN NO.OF 1 2375 0 0 0 0 0 2376 SERVICES 2.MILES OF MAINS IN SYSTEM AT END OF YEAR MATERIAL UNKNOWN 2"OR LESS OVER 2" OVER 4" OVER 8" OVER 12" SYSTEM TOTALS THRU 4" THRU 8" THRU 12" 1.564 STEEL 0 0.062 0.026 1.476 0 0 0 DUCTILE IRON 0 0 0 0 0 0 0 COPPER 0 0 0 0 0 0 CAST/WROUGH 0 0 0 0 0 0 0 T IRON 0 PLASTIC PVC 0 0 0 0 0 0 52.112 PLASTIC PE 0 36.656 12.575 2.881 0 0 0 PLASTIC ABS 0 0 0 0 0 0 PLASTIC 0 0 0 0 0 0 0 OTHER 0 OTHER 0 0 0 0 0 0 RECONDITIONE 0 0 0 0 0 0 0 D CAST IRON 53.676 TOTAL 0 36.718 12.601 4.357 0 0 Describe Other Material: 3.NUMBER OF SERVICES IN SYSTEM AT END OF YEAR AVERAGE SERVICE LENGTH:911 MATERIAL UNKNOWN 1"OR LESS OVER 1" OVER 2" OVER 4" OVER 8" SYSTEM TOTALS THRU 2" THRU 4" THRU 8" 1 STEEL 0 1 0 0 0 0 0 DUCTILE IRON 0 0 0 0 0 0 0 COPPER 0 0 0 0 0 0 CAST/WROUGH 0 0 0 0 0 0 0 T IRON 0 PLASTIC PVC 0 0 0 0 0 0 2375 PLASTIC PE 0 2308 65 2 0 0 0 PLASTIC ABS 0 0 0 0 0 0 PLASTIC 0 0 0 0 0 0 0 OTHER 0 OTHER 0 0 0 0 0 0 RECONDITIONE 0 0 0 0 0 0 0 D CAST IRON 2376 TOTAL 0 2309 65 2 0 0 Describe Other Material: -F 4.MILES OF MAIN AND NUMBER OF SERVICES BY DECADE OF INSTALLATION PRE- 1940- 1950- 1960- 1970- 1980- 1990- 2000- 2010- 2020- UNKNOWN 1940 1949 1959 1969 1979 1989 1999 2009 2019 2029 TOTAL MILES OF 0 0 0 0 0 0 0.049 35.308 14.956 2.413 .950 53.676 MAIN NUMBER OF 0 0 0 0 0 0 0 1649 365 299 63 2376 SERVICES PART C-TOTAL LEAKS AND HAZARDOUS LEAKS ELIMINATED/REPAIRED DURING THE YEAR MAINS SERVICES CAUSE OF LEAK TOTAL HAZARDOUS TOTAL HAZARDOUS CORROSION FAILURE 0 0 0 0 NATURAL FORCE DAMAGE 0 0 1 0 EXCAVATION DAMAGE 0 0 3 3 OTHER OUTSIDE FORCE 0 0 0 0 DAMAGE PIPE,WELD OR JOINT FAILURE 0 0 0 0 EQUIPMENT FAILURE 0 0 2 0 INCORRECT OPERATIONS 0 0 1 0 OTHER CAUSE 0 0 0 0 rW�MBEROFKNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR:0 PART D-EXCAVATION DAMAGE PART E-EXCESS FLOW VALUE(EFV)AND SERVICE VALVE DATA 1.TOTAL NUMBER OF EXCAVATION DAMAGES BY APPARENT Total Number Of Services with EFV Installed During Year: 57 ROOT CAUSE: 3 a. One-Call Notification Practices Not Sufficient: 2 Estimated Number Of Services with EFV In the System At End Of Year: 404 b. Locating Practices Not Sufficient: 0 "Total Number of Manual Service Line Shut-off Valves Installed During c. Excavation Practices Not Sufficient: 1 Year: 1 d. Other: 0 Estimated Number of Services with Manual Service Line Shut-off Valves Installed in the System at End of Year: 1 *These questions were added to the report in 2017. 2. NUMBER OF EXCAVATION TICKETS : 599 PART F-LEAKS ON FEDERAL LAND PART G-PERCENT OF UNACCOUNTED FOR GAS TOTAL NUMBER OF LEAKS ON FEDERAL LAND REPAIRED OR UNACCOUNTED FOR GAS AS A PERCENT OF TOTAL CONSUMPTION SCHEDULED TO REPAIR: 0 FOR THE 12 MONTHS ENDING JUNE 30 OF THE REPORTING YEAR. [(PURCHASED GAS+PRODUCED GAS)MINUS(CUSTOMER USE+ COMPANY USE+APPROPRIATE ADJUSTMENTS)]DIVIDED BY (CUSTOMER USE+COMPANY USE+APPROPRIATE ADJUSTMENTS) TIMES 100 EQUALS PERCENT UNACCOUNTED FOR. FOR YEAR ENDING 6/30: 0 48% PART H-ADDITIONAL INFORMATION Note: Part G-Percent of Unaccounted for Gas is a system wide measurement(Idaho,Utah,Colorado,and Wyoming). PARTI-PREPARER Sarah Silcox,Engineer 1 (801)209-9657 (Preparer's Name and Title) (Area Code and Telephone Number) Sarah.R.Silcox@dominionenergy.com (Preparer's email address) (Area Code and Facsimile Number)