Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DP GT 2023
Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 U.S.Department of Initial Date 03/12/2024 Submitted Transportation Pipeline and Hazardous ANNUAL REPORT FOR CALENDAR YEAR 2023 faMaterials NATURAL and OTHER GAS TRANSMISSION and Report SUPPLEME Safety Administration GATHERING SYSTEMS Submission NTAL Type Date 03/24/2024 Submitted A federal agency may not conduct or sponsor,and a person is not required to respond to,nor shall a person be subject to a penalty for failure to comply with a collection of information subject to the requirements of the Paperwork Reduction Act unless that collection of information displays a current valid OMB Control Number. The OMB Control Number for this information collection is 2137-0522. Public reporting for this collection of information is estimated to be approximately 47 hours per response, including the time for reviewing instructions,gathering the data needed, and completing and reviewing the collection of information. All responses to this collection of information are mandatory. Send comments regarding this burden estimate or any other aspect of this collection of information,including suggestions for reducing this burden to: Information Collection Clearance Officer,PHMSA,Office of Pipeline Safety(PHP-30)1200 New Jersey Avenue,SE,Washington,D.C.20590. Important:Please read the separate instructions for completing this form before you begin. They clarify the information requested and provide specific examples. If you do not have a copy of the instructions,you can obtain one from the PHMSA Pipeline Safety Community Web Page at http✓/www.phmsa.dot.go v/pipeline/library/forms. PART A-OPERATOR INFORMATION DOT USE ONLY 20240871 -44638 1. OPERATOR'S 5 DIGIT IDENTIFICATION NUMBER(OPID) 2. NAME OF OPERATOR: 31442 DOUGLAS PIPELINE CO 4. HEADQUARTERS ADDRESS: 3.RESERVED 901 CASTLE SHANNON BLVD. Street Address PITTSBURGH City State: PA Zip Code: 15234 5.THIS REPORT PERTAINS TO THE FOLLOWING COMMODITY GROUP: (Select Commodity Group based on the predominant gas carried and complete the report for that Commodity Group.File a separate report for each Commodity Group included in this OPID.) ® Natural Gas 13 Synthetic Gas 13 Hydrogen Gas 13 Propane Gas 13 Landfill Gas 13 Other Gas Name of the Other Gas: 6. RESERVED 7. FOR THE DESIGNATED"COMMODITY GROUP",THE PIPELINES AND/OR PIPELINE FACILITIES INCLUDED WITHIN THIS OPID ARE: (Select one or both) ® INTERstate pipeline—List all of the States and OSC portions in which INTERstate pipelines and/or pipeline facilities included under this OPID exist. PENNSYLVANIA, WEST VIRGINIA etc. ® INTRAstate pipeline—List all of the States in which INTRAstate pipelines and or pipeline facilities included under this OPID exist. IDAHO, MARYLAND, NEW JERSEY, OHIO, OKLAHOMA, PENNSYLVANIA, SOUTH CAROLINA etc. 8. RESERVED Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 1 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Use this form for Type A, B, and C gas gathering. Type R gas gathering is reported on Form PHMSA F 7100.2-3. For the designated Commodity Group, PARTS B and D will be calculated based on the data entered in Parts L and P respectively. Complete Part C one time for all pipelines and/or pipeline facilities-both INTERstate and INTRAstate-included within this OPID. PART B—TRANSMISSION PIPELINE HCA,§192.710,and in neither HCA nor§192.710 MILES Number of Class Location 3 Number of Class Location 1 Number of HCA Miles Number of§192.710 Miles or 4 Miles that are neither in or 2 Miles that are neither in HCA nor in§192.710 HCA nor in§192.710 Onshore 1.1 0.57 8.58 56.15 Offshore 1 0 1 0 0 110 Total Miles 1.1 0.57 8.58 56.15 Part B1 —HCA Miles by Determination Method and Risk Model Type Risk Model Type Miles HCA Method 1 Miles HCA Method 2 Total Subject Matter Expert (SME) 0 Relative Risk 0 0 0 Quantitative 0 0 0 Probabilistic 0 0 0 Scenario-Based 0 0 0 Other 0 0 0 Total 0 1.1 1.1 PART C-VOLUME TRANSPORTED IN TRANSMISSION Check this box and do not complete PART C if this PIPELINES(ONLY)IN MILLION SCF PER YEAR 13 report only includes gathering pipelines or (excludesTransmission lines of Gas Distribution systems) transmission lines of gas distribution systems. Onshore Offshore Natural Gas Propane Gas Synthetic Gas Hydrogen Gas Landfill Gas Other Gas-Name: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 2 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART D MILES OF PIPE BY MATERIAL AND CORROSION PREVENTION STATUS Steel Cathodically Steel Cathodically protected unprotected Bare Coated Bare Coated Cast Wrough Plastic Comp Other Total Iron t Iron ositel Miles Transmission Onshore 0 63.9 0 0 0 0 2.52 0 0 66.42 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 63.9 0 0 0 0 2.52 0 0 66.42 Transmission Gathering Onshore Type A 0 0 0 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 0 0 0 Onshore Type C 0 2.1 0 0 0 0 0 0 0 2.1 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal Gathering 0 2.1 0 0 0 0 0 0 0 2.1 Total Miles 0 66 0 0 0 0 2.52 0 0 68.52 1 Use of Composite pipe requires a PHMSA Special Permit or waiver from a State PART E—RESERVED Form PHMSA F 7100.2-1 (rev 3-2022) Pg.3 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 For the designated Commodity Group, complete PARTS F and G one time for all INTERstate gas transmission pipeline facilities included within this OPID and multiple times as needed for the designated Commodity Group for each State in which INTRAstate gas transmission pipeline facilities included within this OPID exist. Part F"WITHIN AN HCA SEGMENT"data and Part G may be completed only if HCA Miles in Part L is greater than zero. Use this form for Type A, B, and C gas gathering. Type R gas gathering is reported on Form PHMSA F 7100.2-3. PARTS F and G The data reported in these PARTS applies to: (select only one) 0 Interstate pipelines/pipeline facilities ® Intrastate pipelines/pipeline facilities in the State of IDAHO (complete for each State) PART F-INTEGRITY INSPECTIONS CONDUCTED AND ACTIONS TAKEN BASED ON INSPECTION INTRASTATEIDAHO 1. MILEAGE INSPECTED IN CALENDAR YEAR USING THE FOLLOWING IN-LINE INSPECTION(ILI)TOOLS a.Corrosion or metal loss tools b.Dent or deformation tools c.Crack or long seam defect detection tools d.Any other internal inspection tools,specify other tools: e.Total tool mileage inspected in calendar year using in-line inspection tools. (Lines a+b+c+d) 2. ACTIONS TAKEN IN CALENDAR YEAR BASED ON IN-LINE INSPECTIONS a. Based on ILI data,total number of anomalies excavated in calendar year because they met the operator's criteria for excavation. b. Total number of anomalies repaired in calendar year that were identified by ILI based on the operator's criteria, 0 both within an HCA Segment and outside of an HCA Segment. c. Total number of conditions repaired WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 3. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON PRESSURE TESTING a.Total mileage inspected by pressure testing in calendar year. b.Total number of pressure test failures(ruptures and leaks)repaired in calendar year,both within an HCA Segment and outside of an HCA Segment. c.Total number of pressure test ruptures(complete failure of pipe wall)repaired in calendar year WITHIN AN HCA SEGMENT. Form PHMSA F 7100.2-1 (rev 3-2022) Pg.4 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 d.Not used e.Total number of pressure test leaks(less than complete wall failure but including escape of test medium) repaired in calendar year WITHIN AN HCA SEGMENT. f.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT. g.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT. 4. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DA(Direct Assessment methods) a.Total mileage inspected by each DA method in calendar year. 0.4 1. ECDA 0.4 2. ICDA 3.SCCDA b.Total number of anomalies identified by each DA method and repaired in calendar year based on the 0 operator's criteria, both within an HCA Segment and outside of an HCA Segment. 1. ECDA 0 2. ICDA 3.SCCDA c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 4.1 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON GUIDED WAVE ULTRASONIC TESTING(GWUT) a.Total mileage inspected by GWUT method in calendar year. b.Total number of anomalies identified by GWUT method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or§192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192 Appendix F,Section XIX] 2."6-Month conditions"(192 Appendix F,Section XIX] 3.12-Month conditions"[192 Appendix F,Section XIX] 4."Monitored conditions"[192 Appendix F,Section XIX] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 4.2 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DIRECT EXAMINATION a.Total mileage inspected by DIRECT EXAMINATION method in calendar year. 0.4 b.Total number of anomalies identified by DIRECT EXAMINATION method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or §192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 5 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 5. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON OTHER INSPECTION TECHNIQUES a.Total mileage inspected by inspection techniques other than those listed above in calendar year. 1.0ther Inspection Techniques b.Total number of anomalies identified by other inspection techniques and repaired in calendar year based on 0 the operator's criteria,both within an HCA Segment and outside of an HCA Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933©] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor §192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor §192.710 SEGMENT: 6.TOTAL MILEAGE INSPECTED(ALL METHODS)AND ACTIONS TAKEN IN CALENDAR YEAR a.Total mileage inspected in calendar year. (Lines 1.e +3.a + 4.a.1 +4.a.2+4.a.3 +5.a) 0.8 b.Total number of anomalies repaired in calendar year both within an HCA Segment and outside of an HCA 0 Segment. (Lines 2.b+3.b+4.b.1 +4.b.2+4.b.3 +5.b) c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT. (Lines 2.0 +2.c.2+2.c.3 +2.c.4+3.c+3.d+4.c.1 +4.c.2+4.c.3+4.c.4+5.c.1 +5.c.2+5.c.3+5.c.4) d.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN AN HCA SEGMENT: e.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN AN HCA SEGMENT: f.Total number of conditions repaired in calendar year WITHIN A§192.710 SEGMENT.(Lines 2.d+3.e+4.d 0 +4.1.d+4.2.d+5.d) g.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A§192.710 SEGMENT: h.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A§192.710 SEGMENT: i.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA 0 nor§192.710 SEGMENT.(Lines 2.e+3.f+4.e+4.1.e+4.2.e+5.e) j.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: k.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: I.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA 0 nor§192.710 SEGMENT.(Lines 2.f+3.g+4.f+4.1.f+4.2.f+5.f) m.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: n.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 6 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART G—MILES OF BASELINE ASSESSMENTS AND REASSESSMENTS COMPLETED IN CALENDAR YEAR (HCA Segment miles ONLY) INTRASTATEIDAHO a. Baseline assessment miles completed during the calendar year. b. Reassessment miles completed during the calendar year. c. Total assessment and reassessment miles completed during the calendar year. d.§192.710 Segments Baseline assessment miles completed during the calendar year. e.§192.710 Segments Reassessment miles completed during the calendar year. f.§192.710 Segments Total assessment and reassessment miles completed during the calendar year. g.CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. h.CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. PARTS F and G The data reported in these PARTS applies to: (select only one) ® Interstate pipelines/pipeline facilities 13 Intrastate pipelines/pipeline facilities in the State of (complete for each State) PART F-INTEGRITY INSPECTIONS CONDUCTED AND ACTIONS TAKEN BASED ON INSPECTION INTERSTATE 1. MILEAGE INSPECTED IN CALENDAR YEAR USING THE FOLLOWING IN-LINE INSPECTION(ILI)TOOLS a.Corrosion or metal loss tools b.Dent or deformation tools c.Crack or long seam defect detection tools d.Any other internal inspection tools,specify other tools: e.Total tool mileage inspected in calendar year using in-line inspection tools. (Lines a+b+c+d) 2. ACTIONS TAKEN IN CALENDAR YEAR BASED ON IN-LINE INSPECTIONS a. Based on ILI data,total number of anomalies excavated in calendar year because they met the operator's criteria for excavation. b. Total number of anomalies repaired in calendar year that were identified by ILI based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. c. Total number of conditions repaired WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 7 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 3. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON PRESSURE TESTING a.Total mileage inspected by pressure testing in calendar year. b.Total number of pressure test failures(ruptures and leaks)repaired in calendar year,both within an HCA Segment and outside of an HCA Segment. c.Total number of pressure test ruptures(complete failure of pipe wall)repaired in calendar year WITHIN AN HCA SEGMENT. d.Not used e.Total number of pressure test leaks(less than complete wall failure but including escape of test medium) repaired in calendar year WITHIN AN HCA SEGMENT. f.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT. g.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT. 4. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DA(Direct Assessment methods) a.Total mileage inspected by each DA method in calendar year. 1. ECDA 2. ICDA 3.SCCDA b.Total number of anomalies identified by each DA method and repaired in calendar year based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. 1. ECDA 2. ICDA 3.SCCDA c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 4.1 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON GUIDED WAVE ULTRASONIC TESTING(GWUT) a.Total mileage inspected by GWUT method in calendar year. b.Total number of anomalies identified by GWUT method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or§192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1.`Immediate repair conditions"[192 Appendix F,Section XIX] 2."6-Month conditions"(192 Appendix F,Section XIX] 3.12-Month conditions"[192 Appendix F,Section XIX] 4."Monitored conditions"[192 Appendix F,Section XIX] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 8 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 4.2 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DIRECT EXAMINATION a.Total mileage inspected by DIRECT EXAMINATION method in calendar year. b.Total number of anomalies identified by DIRECT EXAMINATION method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or §192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 5. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON OTHER INSPECTION TECHNIQUES a.Total mileage inspected by inspection techniques other than those listed above in calendar year. 1.Other Inspection Techniques b.Total number of anomalies identified by other inspection techniques and repaired in calendar year based on the operator's criteria,both within an HCA Segment and outside of an HCA Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933©] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor §192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor §192.710 SEGMENT: 6.TOTAL MILEAGE INSPECTED(ALL METHODS)AND ACTIONS TAKEN IN CALENDAR YEAR a.Total mileage inspected in calendar year. (Lines 1.e +3.a + 4.a.1 +4.a.2+4.a.3 +5.a) b.Total number of anomalies repaired in calendar year both within an HCA Segment and outside of an HCA Segment. (Lines 2.b+3.b+4.b.1 +4.b.2+4.b.3 +5.b) c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT. (Lines 2.c.1 +2.c.2+2.c.3 +2.c.4+3.c+3.d+4.c.1 +4.c.2+4.c.3+4.c.4+5.0 +5.c.2+5.c.3+5.c.4) d.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN AN HCA SEGMENT: e.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN AN HCA SEGMENT: f.Total number of conditions repaired in calendar year WITHIN A§192.710 SEGMENT.(Lines 2.d+3.e+4.d 0 +4.1.d+4.2.d+5.d) g.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A§192.710 SEGMENT: h.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A§192.710 SEGMENT: i.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA 0 nor§192.710 SEGMENT.(Lines 2.e+3.f+4.e+4.1.e+4.2.e+5.e) j.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: k.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 9 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 I.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA 0 nor§192.710 SEGMENT.(Lines 2.f+3.g+4.f+4.1.f+4.2.f+5.f) m.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: n.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 10 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART G—MILES OF BASELINE ASSESSMENTS AND REASSESSMENTS COMPLETED IN CALENDAR YEAR (HCA Segment miles ONLY) INTERSTATE a. Baseline assessment miles completed during the calendar year. b. Reassessment miles completed during the calendar year. c. Total assessment and reassessment miles completed during the calendar year. d.§192.710 Segments Baseline assessment miles completed during the calendar year. e.§192.710 Segments Reassessment miles completed during the calendar year. f.§192.710 Segments Total assessment and reassessment miles completed during the calendar year. g.CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. h.CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. PARTS F and G The data reported in these PARTS applies to: (select only one) 0 Interstate pipelines/pipeline facilities ® Intrastate pipelines/pipeline facilities in the State of MARYLAND (complete for each State) PART F-INTEGRITY INSPECTIONS CONDUCTED AND ACTIONS TAKEN BASED ON INSPECTION INTRASTATE MARYLAND 1. MILEAGE INSPECTED IN CALENDAR YEAR USING THE FOLLOWING IN-LINE INSPECTION(ILI)TOOLS a.Corrosion or metal loss tools b.Dent or deformation tools c.Crack or long seam defect detection tools d.Any other internal inspection tools,specify other tools: e.Total tool mileage inspected in calendar year using in-line inspection tools. (Lines a+b+c+d) 2. ACTIONS TAKEN IN CALENDAR YEAR BASED ON IN-LINE INSPECTIONS a. Based on ILI data,total number of anomalies excavated in calendar year because they met the operator's criteria for excavation. b. Total number of anomalies repaired in calendar year that were identified by ILI based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. c. Total number of conditions repaired WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 11 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 3. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON PRESSURE TESTING a.Total mileage inspected by pressure testing in calendar year. b.Total number of pressure test failures(ruptures and leaks)repaired in calendar year,both within an HCA Segment and outside of an HCA Segment. c.Total number of pressure test ruptures(complete failure of pipe wall)repaired in calendar year WITHIN AN HCA SEGMENT. d.Not used e.Total number of pressure test leaks(less than complete wall failure but including escape of test medium) repaired in calendar year WITHIN AN HCA SEGMENT. f.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT. g.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT. 4. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DA(Direct Assessment methods) a.Total mileage inspected by each DA method in calendar year. 1. ECDA 2. ICDA 3.SCCDA b.Total number of anomalies identified by each DA method and repaired in calendar year based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. 1. ECDA 2. ICDA 3.SCCDA c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 4.1 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON GUIDED WAVE ULTRASONIC TESTING(GWUT) a.Total mileage inspected by GWUT method in calendar year. b.Total number of anomalies identified by GWUT method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or§192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1.`Immediate repair conditions"[192 Appendix F,Section XIX] 2."6-Month conditions"(192 Appendix F,Section XIX] 3.12-Month conditions"[192 Appendix F,Section XIX] 4."Monitored conditions"[192 Appendix F,Section XIX] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 12 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 4.2 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DIRECT EXAMINATION a.Total mileage inspected by DIRECT EXAMINATION method in calendar year. b.Total number of anomalies identified by DIRECT EXAMINATION method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or §192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 5. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON OTHER INSPECTION TECHNIQUES a.Total mileage inspected by inspection techniques other than those listed above in calendar year. 1.Other Inspection Techniques b.Total number of anomalies identified by other inspection techniques and repaired in calendar year based on the operator's criteria,both within an HCA Segment and outside of an HCA Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933©] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor §192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor §192.710 SEGMENT: 6.TOTAL MILEAGE INSPECTED(ALL METHODS)AND ACTIONS TAKEN IN CALENDAR YEAR a.Total mileage inspected in calendar year. (Lines 1.e +3.a + 4.a.1 +4.a.2+4.a.3 +5.a) b.Total number of anomalies repaired in calendar year both within an HCA Segment and outside of an HCA Segment. (Lines 2.b+3.b+4.b.1 +4.b.2+4.b.3 +5.b) c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT. (Lines 2.c.1 +2.c.2+2.c.3 +2.c.4+3.c+3.d+4.c.1 +4.c.2+4.c.3+4.c.4+5.0 +5.c.2+5.c.3+5.c.4) d.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN AN HCA SEGMENT: e.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN AN HCA SEGMENT: f.Total number of conditions repaired in calendar year WITHIN A§192.710 SEGMENT.(Lines 2.d+3.e+4.d +4.1.d+4.2.d+5.d) g.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A§192.710 SEGMENT: h.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A§192.710 SEGMENT: i.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT.(Lines 2.e+3.f+4.e+4.1.e+4.2.e+5.e) j.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: k.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 13 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 I.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT.(Lines 2.f+3.g+4.f+4.1.f+4.2.f+5.f) m.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: n.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 14 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART G—MILES OF BASELINE ASSESSMENTS AND REASSESSMENTS COMPLETED IN CALENDAR YEAR (HCA Segment miles ONLY) INTRASTATE MARYLAND a. Baseline assessment miles completed during the calendar year. b. Reassessment miles completed during the calendar year. c. Total assessment and reassessment miles completed during the calendar year. d.§192.710 Segments Baseline assessment miles completed during the calendar year. e.§192.710 Segments Reassessment miles completed during the calendar year. f.§192.710 Segments Total assessment and reassessment miles completed during the calendar year. g.CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. h.CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. PARTS F and G The data reported in these PARTS applies to: (select only one) 0 Interstate pipelines/pipeline facilities ® Intrastate pipelines/pipeline facilities in the State of OHIO (complete for each State) PART F-INTEGRITY INSPECTIONS CONDUCTED AND ACTIONS TAKEN BASED ON INSPECTION INTRASTATE OHIO 1. MILEAGE INSPECTED IN CALENDAR YEAR USING THE FOLLOWING IN-LINE INSPECTION(ILI)TOOLS a.Corrosion or metal loss tools b.Dent or deformation tools c.Crack or long seam defect detection tools d.Any other internal inspection tools,specify other tools: e.Total tool mileage inspected in calendar year using in-line inspection tools. (Lines a+b+c+d) 2. ACTIONS TAKEN IN CALENDAR YEAR BASED ON IN-LINE INSPECTIONS a. Based on ILI data,total number of anomalies excavated in calendar year because they met the operator's criteria for excavation. b. Total number of anomalies repaired in calendar year that were identified by ILI based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. c. Total number of conditions repaired WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 15 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 3. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON PRESSURE TESTING a.Total mileage inspected by pressure testing in calendar year. b.Total number of pressure test failures(ruptures and leaks)repaired in calendar year,both within an HCA Segment and outside of an HCA Segment. c.Total number of pressure test ruptures(complete failure of pipe wall)repaired in calendar year WITHIN AN HCA SEGMENT. d.Not used e.Total number of pressure test leaks(less than complete wall failure but including escape of test medium) repaired in calendar year WITHIN AN HCA SEGMENT. f.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT. g.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT. 4. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DA(Direct Assessment methods) a.Total mileage inspected by each DA method in calendar year. 1. ECDA 2. ICDA 3.SCCDA b.Total number of anomalies identified by each DA method and repaired in calendar year based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. 1. ECDA 2. ICDA 3.SCCDA c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 4.1 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON GUIDED WAVE ULTRASONIC TESTING(GWUT) a.Total mileage inspected by GWUT method in calendar year. b.Total number of anomalies identified by GWUT method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or§192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1.`Immediate repair conditions"[192 Appendix F,Section XIX] 2."6-Month conditions"(192 Appendix F,Section XIX] 3.12-Month conditions"[192 Appendix F,Section XIX] 4."Monitored conditions"[192 Appendix F,Section XIX] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 16 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 4.2 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DIRECT EXAMINATION a.Total mileage inspected by DIRECT EXAMINATION method in calendar year. b.Total number of anomalies identified by DIRECT EXAMINATION method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or §192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 5. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON OTHER INSPECTION TECHNIQUES a.Total mileage inspected by inspection techniques other than those listed above in calendar year. 1.Other Inspection Techniques b.Total number of anomalies identified by other inspection techniques and repaired in calendar year based on the operator's criteria,both within an HCA Segment and outside of an HCA Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933©] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor §192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor §192.710 SEGMENT: 6.TOTAL MILEAGE INSPECTED(ALL METHODS)AND ACTIONS TAKEN IN CALENDAR YEAR a.Total mileage inspected in calendar year. (Lines 1.e +3.a + 4.a.1 +4.a.2+4.a.3 +5.a) b.Total number of anomalies repaired in calendar year both within an HCA Segment and outside of an HCA Segment. (Lines 2.b+3.b+4.b.1 +4.b.2+4.b.3 +5.b) c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT. (Lines 2.c.1 +2.c.2+2.c.3 +2.c.4+3.c+3.d+4.c.1 +4.c.2+4.c.3+4.c.4+5.0 +5.c.2+5.c.3+5.c.4) d.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN AN HCA SEGMENT: e.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN AN HCA SEGMENT: f.Total number of conditions repaired in calendar year WITHIN A§192.710 SEGMENT.(Lines 2.d+3.e+4.d +4.1.d+4.2.d+5.d) g.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A§192.710 SEGMENT: h.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A§192.710 SEGMENT: i.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT.(Lines 2.e+3.f+4.e+4.1.e+4.2.e+5.e) j.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: k.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 17 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 I.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT.(Lines 2.f+3.g+4.f+4.1.f+4.2.f+5.f) m.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: n.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 18 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART G—MILES OF BASELINE ASSESSMENTS AND REASSESSMENTS COMPLETED IN CALENDAR YEAR (HCA Segment miles ONLY) INTRASTATE OHIO a. Baseline assessment miles completed during the calendar year. b. Reassessment miles completed during the calendar year. c. Total assessment and reassessment miles completed during the calendar year. d.§192.710 Segments Baseline assessment miles completed during the calendar year. e.§192.710 Segments Reassessment miles completed during the calendar year. f.§192.710 Segments Total assessment and reassessment miles completed during the calendar year. g.CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. h.CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. PARTS F and G The data reported in these PARTS applies to: (select only one) 0 Interstate pipelines/pipeline facilities ® Intrastate pipelines/pipeline facilities in the State of OKLAHOMA (complete for each State) PART F-INTEGRITY INSPECTIONS CONDUCTED AND ACTIONS TAKEN BASED ON INSPECTION INTRASTATE OKLAHOMA 1. MILEAGE INSPECTED IN CALENDAR YEAR USING THE FOLLOWING IN-LINE INSPECTION(ILI)TOOLS a.Corrosion or metal loss tools b.Dent or deformation tools c.Crack or long seam defect detection tools d.Any other internal inspection tools,specify other tools: e.Total tool mileage inspected in calendar year using in-line inspection tools. (Lines a+b+c+d) 2. ACTIONS TAKEN IN CALENDAR YEAR BASED ON IN-LINE INSPECTIONS a. Based on ILI data,total number of anomalies excavated in calendar year because they met the operator's criteria for excavation. b. Total number of anomalies repaired in calendar year that were identified by ILI based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. c. Total number of conditions repaired WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 19 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 3. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON PRESSURE TESTING a.Total mileage inspected by pressure testing in calendar year. b.Total number of pressure test failures(ruptures and leaks)repaired in calendar year,both within an HCA Segment and outside of an HCA Segment. c.Total number of pressure test ruptures(complete failure of pipe wall)repaired in calendar year WITHIN AN HCA SEGMENT. d.Not used e.Total number of pressure test leaks(less than complete wall failure but including escape of test medium) repaired in calendar year WITHIN AN HCA SEGMENT. f.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT. g.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT. 4. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DA(Direct Assessment methods) a.Total mileage inspected by each DA method in calendar year. 1. ECDA 2. ICDA 3.SCCDA b.Total number of anomalies identified by each DA method and repaired in calendar year based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. 1. ECDA 2. ICDA 3.SCCDA c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 4.1 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON GUIDED WAVE ULTRASONIC TESTING(GWUT) a.Total mileage inspected by GWUT method in calendar year. b.Total number of anomalies identified by GWUT method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or§192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1.`Immediate repair conditions"[192 Appendix F,Section XIX] 2."6-Month conditions"(192 Appendix F,Section XIX] 3.12-Month conditions"[192 Appendix F,Section XIX] 4."Monitored conditions"[192 Appendix F,Section XIX] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 20 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 4.2 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DIRECT EXAMINATION a.Total mileage inspected by DIRECT EXAMINATION method in calendar year. b.Total number of anomalies identified by DIRECT EXAMINATION method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or §192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 5. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON OTHER INSPECTION TECHNIQUES a.Total mileage inspected by inspection techniques other than those listed above in calendar year. 1.Other Inspection Techniques b.Total number of anomalies identified by other inspection techniques and repaired in calendar year based on the operator's criteria,both within an HCA Segment and outside of an HCA Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933©] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor §192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor §192.710 SEGMENT: 6.TOTAL MILEAGE INSPECTED(ALL METHODS)AND ACTIONS TAKEN IN CALENDAR YEAR a.Total mileage inspected in calendar year. (Lines 1.e +3.a + 4.a.1 +4.a.2+4.a.3 +5.a) b.Total number of anomalies repaired in calendar year both within an HCA Segment and outside of an HCA Segment. (Lines 2.b+3.b+4.b.1 +4.b.2+4.b.3 +5.b) c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT. (Lines 2.c.1 +2.c.2+2.c.3 +2.c.4+3.c+3.d+4.c.1 +4.c.2+4.c.3+4.c.4+5.0 +5.c.2+5.c.3+5.c.4) d.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN AN HCA SEGMENT: e.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN AN HCA SEGMENT: f.Total number of conditions repaired in calendar year WITHIN A§192.710 SEGMENT.(Lines 2.d+3.e+4.d +4.1.d+4.2.d+5.d) g.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A§192.710 SEGMENT: h.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A§192.710 SEGMENT: i.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT.(Lines 2.e+3.f+4.e+4.1.e+4.2.e+5.e) j.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: k.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 21 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 I.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT.(Lines 2.f+3.g+4.f+4.1.f+4.2.f+5.f) m.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: n.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 22 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART G—MILES OF BASELINE ASSESSMENTS AND REASSESSMENTS COMPLETED IN CALENDAR YEAR (HCA Segment miles ONLY) INTRASTATE OKLAHOMA a. Baseline assessment miles completed during the calendar year. b. Reassessment miles completed during the calendar year. c. Total assessment and reassessment miles completed during the calendar year. d.§192.710 Segments Baseline assessment miles completed during the calendar year. e.§192.710 Segments Reassessment miles completed during the calendar year. f.§192.710 Segments Total assessment and reassessment miles completed during the calendar year. g.CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. h.CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. PARTS F and G The data reported in these PARTS applies to: (select only one) 0 Interstate pipelines/pipeline facilities ® Intrastate pipelines/pipeline facilities in the State of PENNSYLVANIA (complete for each State) PART F-INTEGRITY INSPECTIONS CONDUCTED AND ACTIONS TAKEN BASED ON INSPECTION INTRASTATE PENNSYLVANIA 1. MILEAGE INSPECTED IN CALENDAR YEAR USING THE FOLLOWING IN-LINE INSPECTION(ILI)TOOLS a.Corrosion or metal loss tools b.Dent or deformation tools c.Crack or long seam defect detection tools d.Any other internal inspection tools,specify other tools: e.Total tool mileage inspected in calendar year using in-line inspection tools. (Lines a+b+c+d) 2. ACTIONS TAKEN IN CALENDAR YEAR BASED ON IN-LINE INSPECTIONS a. Based on ILI data,total number of anomalies excavated in calendar year because they met the operator's criteria for excavation. b. Total number of anomalies repaired in calendar year that were identified by ILI based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. c. Total number of conditions repaired WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 23 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 3. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON PRESSURE TESTING a.Total mileage inspected by pressure testing in calendar year. b.Total number of pressure test failures(ruptures and leaks)repaired in calendar year,both within an HCA Segment and outside of an HCA Segment. c.Total number of pressure test ruptures(complete failure of pipe wall)repaired in calendar year WITHIN AN HCA SEGMENT. d.Not used e.Total number of pressure test leaks(less than complete wall failure but including escape of test medium) repaired in calendar year WITHIN AN HCA SEGMENT. f.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT. g.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT. 4. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DA(Direct Assessment methods) a.Total mileage inspected by each DA method in calendar year. 1. ECDA 2. ICDA 3.SCCDA b.Total number of anomalies identified by each DA method and repaired in calendar year based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. 1. ECDA 2. ICDA 3.SCCDA c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 4.1 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON GUIDED WAVE ULTRASONIC TESTING(GWUT) a.Total mileage inspected by GWUT method in calendar year. b.Total number of anomalies identified by GWUT method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or§192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1.`Immediate repair conditions"[192 Appendix F,Section XIX] 2."6-Month conditions"(192 Appendix F,Section XIX] 3.12-Month conditions"[192 Appendix F,Section XIX] 4."Monitored conditions"[192 Appendix F,Section XIX] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 24 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 4.2 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DIRECT EXAMINATION a.Total mileage inspected by DIRECT EXAMINATION method in calendar year. b.Total number of anomalies identified by DIRECT EXAMINATION method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or §192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 5. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON OTHER INSPECTION TECHNIQUES a.Total mileage inspected by inspection techniques other than those listed above in calendar year. 1.Other Inspection Techniques b.Total number of anomalies identified by other inspection techniques and repaired in calendar year based on the operator's criteria,both within an HCA Segment and outside of an HCA Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933©] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor §192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor §192.710 SEGMENT: 6.TOTAL MILEAGE INSPECTED(ALL METHODS)AND ACTIONS TAKEN IN CALENDAR YEAR a.Total mileage inspected in calendar year. (Lines 1.e +3.a + 4.a.1 +4.a.2+4.a.3 +5.a) b.Total number of anomalies repaired in calendar year both within an HCA Segment and outside of an HCA Segment. (Lines 2.b+3.b+4.b.1 +4.b.2+4.b.3 +5.b) c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT. (Lines 2.c.1 +2.c.2+2.c.3 +2.c.4+3.c+3.d+4.c.1 +4.c.2+4.c.3+4.c.4+5.0 +5.c.2+5.c.3+5.c.4) d.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN AN HCA SEGMENT: e.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN AN HCA SEGMENT: f.Total number of conditions repaired in calendar year WITHIN A§192.710 SEGMENT.(Lines 2.d+3.e+4.d +4.1.d+4.2.d+5.d) g.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A§192.710 SEGMENT: h.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A§192.710 SEGMENT: i.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT.(Lines 2.e+3.f+4.e+4.1.e+4.2.e+5.e) j.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: k.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 25 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 I.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT.(Lines 2.f+3.g+4.f+4.1.f+4.2.f+5.f) m.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: n.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 26 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART G—MILES OF BASELINE ASSESSMENTS AND REASSESSMENTS COMPLETED IN CALENDAR YEAR (HCA Segment miles ONLY) INTRASTATE PENNSYLVANIA a. Baseline assessment miles completed during the calendar year. b. Reassessment miles completed during the calendar year. c. Total assessment and reassessment miles completed during the calendar year. d.§192.710 Segments Baseline assessment miles completed during the calendar year. e.§192.710 Segments Reassessment miles completed during the calendar year. f.§192.710 Segments Total assessment and reassessment miles completed during the calendar year. g.CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. h.CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. PARTS F and G The data reported in these PARTS applies to: (select only one) 0 Interstate pipelines/pipeline facilities ® Intrastate pipelines/pipeline facilities in the State of SOUTH CAROLINA (complete for each State) PART F-INTEGRITY INSPECTIONS CONDUCTED AND ACTIONS TAKEN BASED ON INSPECTION INTRASTATE SOUTH CAROLINA 1. MILEAGE INSPECTED IN CALENDAR YEAR USING THE FOLLOWING IN-LINE INSPECTION(ILI)TOOLS a.Corrosion or metal loss tools b.Dent or deformation tools c.Crack or long seam defect detection tools d.Any other internal inspection tools,specify other tools: e.Total tool mileage inspected in calendar year using in-line inspection tools. (Lines a+b+c+d) 2. ACTIONS TAKEN IN CALENDAR YEAR BASED ON IN-LINE INSPECTIONS a. Based on ILI data,total number of anomalies excavated in calendar year because they met the operator's criteria for excavation. b. Total number of anomalies repaired in calendar year that were identified by ILI based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. c. Total number of conditions repaired WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 27 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 3. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON PRESSURE TESTING a.Total mileage inspected by pressure testing in calendar year. b.Total number of pressure test failures(ruptures and leaks)repaired in calendar year,both within an HCA Segment and outside of an HCA Segment. c.Total number of pressure test ruptures(complete failure of pipe wall)repaired in calendar year WITHIN AN HCA SEGMENT. d.Not used e.Total number of pressure test leaks(less than complete wall failure but including escape of test medium) repaired in calendar year WITHIN AN HCA SEGMENT. f.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT. g.Total number of pressure test failures(ruptures and leaks)repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT. 4. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DA(Direct Assessment methods) a.Total mileage inspected by each DA method in calendar year. 1. ECDA 2. ICDA 3.SCCDA b.Total number of anomalies identified by each DA method and repaired in calendar year based on the operator's criteria, both within an HCA Segment and outside of an HCA Segment. 1. ECDA 2. ICDA 3.SCCDA c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 4.1 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON GUIDED WAVE ULTRASONIC TESTING(GWUT) a.Total mileage inspected by GWUT method in calendar year. b.Total number of anomalies identified by GWUT method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or§192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1.`Immediate repair conditions"[192 Appendix F,Section XIX] 2."6-Month conditions"(192 Appendix F,Section XIX] 3.12-Month conditions"[192 Appendix F,Section XIX] 4."Monitored conditions"[192 Appendix F,Section XIX] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 28 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 4.2 MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON DIRECT EXAMINATION a.Total mileage inspected by DIRECT EXAMINATION method in calendar year. b.Total number of anomalies identified by DIRECT EXAMINATION method and repaired in calendar year based on the operator's criteria,within an HCA Segment,within a§192.710 Segment,and outside of an HCA or §192.710 Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933(c)] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: 5. MILEAGE INSPECTED AND ACTIONS TAKEN IN CALENDAR YEAR BASED ON OTHER INSPECTION TECHNIQUES a.Total mileage inspected by inspection techniques other than those listed above in calendar year. 1.Other Inspection Techniques b.Total number of anomalies identified by other inspection techniques and repaired in calendar year based on the operator's criteria,both within an HCA Segment and outside of an HCA Segment. c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT meeting the definition of: 1."Immediate repair conditions"[192.933(d)(1)] 2."One-year conditions"[192.933(d)(2)] 3."Monitored conditions"[192.933(d)(3)] 4.Other"Scheduled conditions"[192.933©] d.Total number of conditions repaired WITHIN A§192.710 SEGMENT: e.Total number of conditions repaired WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor §192.710 SEGMENT: f.Total number of conditions repaired WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor §192.710 SEGMENT: 6.TOTAL MILEAGE INSPECTED(ALL METHODS)AND ACTIONS TAKEN IN CALENDAR YEAR a.Total mileage inspected in calendar year. (Lines 1.e +3.a + 4.a.1 +4.a.2+4.a.3 +5.a) b.Total number of anomalies repaired in calendar year both within an HCA Segment and outside of an HCA Segment. (Lines 2.b+3.b+4.b.1 +4.b.2+4.b.3 +5.b) c.Total number of conditions repaired in calendar year WITHIN AN HCA SEGMENT. (Lines 2.c.1 +2.c.2+2.c.3 +2.c.4+3.c+3.d+4.c.1 +4.c.2+4.c.3+4.c.4+5.0 +5.c.2+5.c.3+5.c.4) d.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN AN HCA SEGMENT: e.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN AN HCA SEGMENT: f.Total number of conditions repaired in calendar year WITHIN A§192.710 SEGMENT.(Lines 2.d+3.e+4.d +4.1.d+4.2.d+5.d) g.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A§192.710 SEGMENT: h.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A§192.710 SEGMENT: i.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT.(Lines 2.e+3.f+4.e+4.1.e+4.2.e+5.e) j.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: k.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 29 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 I.Total number of conditions repaired in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT.(Lines 2.f+3.g+4.f+4.1.f+4.2.f+5.f) m.Total number of actionable anomalies eliminated by pipe replacement in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: n.Total number of actionable anomalies eliminated by pipe abandonment in calendar year WITHIN A CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 SEGMENT: Form PHMSA F 7100.2-1 (rev 3-2022) Pg.30 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART G—MILES OF BASELINE ASSESSMENTS AND REASSESSMENTS COMPLETED IN CALENDAR YEAR (HCA Segment miles ONLY) INTRASTATE SOUTH CAROLINA a. Baseline assessment miles completed during the calendar year. b. Reassessment miles completed during the calendar year. c. Total assessment and reassessment miles completed during the calendar year. d.§192.710 Segments Baseline assessment miles completed during the calendar year. e.§192.710 Segments Reassessment miles completed during the calendar year. f.§192.710 Segments Total assessment and reassessment miles completed during the calendar year. g.CLASS LOCATION 3 OR 4 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. h.CLASS LOCATION 1 OR 2 AND neither HCA nor§192.710 Segments assessment miles completed during the calendar year. Form PHMSA F 7100.2-1 (rev 3-2022) Pg.31 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Use this form for Type A, B, and C gas gathering. Type R gas gathering is reported on Form PHMSA F 7100.2-3. For the designated Commodity Group, complete PARTS H, 1, J, K, L, M, P, Q, R, S, and T covering INTERstate pipeline facilities for each State in which INTERstate systems exist within this OPID and again covering INTRAstate pipeline facilities for each State in which 1NTRAstate systems exist within this OP1D. PARTS H, I, J, K, L, M, P, Q, R, S, and T The data reported in these PARTS applies to: (select only one) 13 Interstate pipelines/pipeline facilities in the State of ® Intrastate pipelines/pipeline facilities in the State of IDAHO PART H-MILES OF TRANSMISSION PIPE BY NOMINAL PIPE SIZE(NPS) INTRASTATEIDAHO NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 1.3 0.7 0 0 0 0 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Onshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 2 Total Miles of Onshore Pipe—Transmission NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Offshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Offshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg.32 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART I - MILES OF GATHERING PIPE BY NOMINAL PIPE SIZE (NPS) INTRASTATEIDAHO NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore Type A 0 0 0 0 0 0 0 0 0 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type A Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type B 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type B Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type C 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Other Pipe Sizes Not Listed:0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type C Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less Offshore 22 24 26 28 30 32 34 36 38 Form PHMSA F 7100.2-1 (rev 3-2022) Pg.33 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 40 42 44 46 48 52 56 58 and over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Gathering Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 34 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART J — MILES OF PIPE BY DECADE INSTALLED INTRASTATEIDAHO Decade Pipe Unknown Pre-40 1940-1949 1950-1959 1960-1969 1970-1979 1980-1989 Installed Transmission Onshore 0 0 0 0 0 0 0 Offshore Subtotal Transmission 0 0 0 0 0 0 0 Gathering Onshore Type A 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 Offshore Subtotal Gathering 0 0 0 0 0 0 0 Total Miles 0 0 0 0 0 0 0 Decade Pipe 1990-1999 2000-2009 2010-2019 2020-2029 Total Miles Installed Transmission Onshore 0 0.7 1.3 0 2 Offshore Subtotal Transmission 0 0.7 1.3 0 2 Gathering Onshore Type A 0 0 0 0 0 Onshore Type B 0 0 0 0 0 Onshore Type c 0 0 0 0 0 Offshore Subtotal Gathering 1 0 10 10 0 10 Total Miles 1 0 0.7 1.3 0 2 Form PHMSA F 7100.2-1 (rev 3-2022) Pg.35 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART K-MILES OF TRANSMISSION PIPE BY SPECIFIED MINIMUM YIELD STRENGTH INTRASTATEIDAHO CLASS LOCATION Total Miles ONSHORE Class I Class 2 Class 3 Class 4 Steel pipe Less than 20%SMYS 0 0 0 0 0 Steel pipe Greater than or equal to 0 0 0 0 0 20%SMYS but less than 30%SMYS Steel pipe Greater than or equal to 30%SMYS but less than or equal to 0 0 0 0 0 0 SMYS Steel pipe Greater than 40%SMYS 0 0 0 0 0 but less than or equal to 50%SMYS Steel pipe Greater than 50%SMYS 1.6 0 0.4 0 2 but less than or equal to 60%SMYS Steel pipe Greater than 60%SMYS 0 0 0 0 0 but less than or equal to 72%SMYS Steel pipe Greater than 72%SMYS 0 0 0 0 0 but less than or equal to 80%SMYS Steel pipe Greater than 80%SMYS 0 0 0 0 0 Steel pipe Unknown percent of SMYS 0 0 0 0 0 All Non-Steel pipe 0 0 0 0 0 Onshore Totals 1.6 0 0.4 0 2 OFFSHORE Class I Steel pipe Less than or equal to 50% SMYS Steel pipe Greater than 50%SMYS but less than or egual to 0 SMYS Steel pipe Greater than 72%SMYS Steel Pipe Unknown percent of SMYS All non-steel pipe Offshore Total Total Miles 1.6 2 Form PHMSA F 7100.2-1 (rev 3-2022) Pg.36 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART L-MILES OF PIPE BY CLASS LOCATION INTRASTATEIDAHO Class Location Class Class Total Location 3 Location 1 Class HCA §192 or 4 Miles or 2 Miles Class I Class 2 Class 3 Class 4 Location Miles .710 that are that are Miles Miles neither in neither in HCA nor in HCA nor in §192.710 §192.710 Transmission Onshore 1.6 0 0.4 0 2 0.4 0.15 1.45 Offshore 0 Subtotal 1.6 0 0.4 0 2 0.4 0.15 1.45 Transmission Gathering Onshore Type 0 0 0 0 A Onshore Type 0 0 0 0 B Onshore Type 0 0 C Offshore 0 0 Subtotal 0 0 0 0 0 Gathering Total Miles 1.6 0 0.4 0 2 0.4 0.15 1.45 Form PHMSA F 7100.2-1 (rev 3-2022) Pg.37 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART M—FAILURES, LEAKS,AND REPAIRS INTRASTATEIDAHO PART M1 —ALL LEAKS ELIMINATED/REPAIRED IN CALENDAR YEAR; INCIDENTS&FAILURES IN HCA SEGMENTS IN CALENDAR YEAR Transmission Leaks,and Failures Gathering Leaks Leaks Failures Offsh Onshore Leaks Offshore Leaks in HCA Onshore Leaks ore Cause Segment Leaks s class Class 1 3&4 non- & Non- Type Type HCA MCA HCA non- HCA HCA Type A B C &non- HCA MCA &non-MCA External Corrosion Internal Corrosion Stress Corrosion Cracking Manufacturing Construction Equipment Incorrect Operations Third Party Damage/Mechanical Damage Excavation Damage Previous Damage(due to Excavation Activity) Vandalism (includes all Intentional Damage) Weather Related/Other Outside Force Natural Force Damage(all) Other Outside Force Damage (excluding Vandalism and all Intentional Damage) Other Total Form PHMSA F 7100.2-1 (rev 3-2022) Pg.38 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Fxoires::3/31/2025 PART M2—KNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR Transmission I Gathering PART M3—LEAKS ON FEDERAL LAND OR OCS REPAIRED OR SCHEDULED FOR REPAIR Transmission Gatherin Onshore Type A Onshore Onshore Type B Onshore Type C OCS OCS Subtotal Transmission Subtotal Gathering Total PART P-MILES OF PIPE BY MATERIAL AND CORROSION PREVENTION STATUS INTRASTATEIDAHO Steel Steel Cathodically Cathodically protected unprotected Coate Bare Coate Cast Wrought Plastic Other CoCornosite 2 Total Bare d d Iron Iron Miles Transmission Onshore 0 2 0 0 0 0 0 0 0 2 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 2 0 0 0 0 0 0 0 2 Transmission Gathering Onshore Type A 0 0 0 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 0 0 0 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 0 0 0 0 0 0 0 0 0 Gathering Total Miles 1 0 1 2 1 0 1 0 1 0 1 0 1 0 0 0 2 1 Use of Composite pipe requires PHMSA Special Permit or waiver from a State 2specify Other material(s): ; Form PHMSA F 7100.2-1 (rev 3-2022) Pg.39 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part Q- Gas Transmission Miles by MAOP Determination Method INTRASTATE IDAHO by§192.619 and Other Methods (a)(1) (a)(2) (a)(3) (c) (d) OtherIncomp (a)(4 Incomp Incom Other(a)(1) ete (a)(2) ncom le (a)(3) Incom le (a)(4) Incomplet (c) late (d) late 1 Incompl Total Record Total to Total to Total a Records Total Total p ete s Records Records Record Record Total s s Records Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 1 (in MCA Class 1 (not in 0 1.6 0 0 0 0 0 HCA or MCA i i Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 2 (in MCA Class 2 (not in 0 0 0 0 0 0 0 HCA or MCA Class 3 (in 0 0 0.4 0 0 0 0 0 0 0 0 0 0 0 HCA Class 3 (in MCA Class 3 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 4 (in MCA Class 4 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Total 0 0 2 0 0 0 0 0 0 0 0 0 0 0 by 4192.624 Methods (c)(1)Total (c)(2)Total (c)(3)Total (c)(4)Total (c)(5)Total (c)(6)Total Class 1 in HCA Class 1 (in MCA Class 1 (not in HCA or MCA Class 2 in HCA Class 2(in MCA Form PHMSA F 7100.2-1 (rev 3-2022) Pg.40 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Ex ire 3/31/20 Class 2(not in HCA or MCA Class 3 in HCA Class 3(in MCA Class 3(not in HCA or MCA Class 4 in HCA Class 4(in MCA Class 4(not in HCA or MCA Total Total under 192.619(a), 192.619(c), 192.619(d) and 2 Other Total under 192.624 as allowed by 192.619 e Grand Total 2 Sum of Total row for all "Incomplete Records" 0 columns Specify Other method(s): Class 1(in Class 1(in Class 1(not in MCA HCA) MCA) or HCA) Class 2(in Class 2(in Class 2(notin MCA HCA) MCA) or HCA) Class 3(in Class 3(in Class 3(not in MCA HCA) MCA) or HCA) Class 4(in Class 4(in Class 4(not in MCA HCA) MCA) or HCA) Form PHMSA F 7100.2-1 (rev 3-2022) Pg.41 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part R—Gas Transmission Miles by Pressure Test(PT)Range and Internal Inspection INTRASTATEIDAHO PT>_ 1.50 MAOP 1.5 MAOP> PT>- 1.39 MAOP Miles Internal Miles Internal Miles Internal Miles Internal Location Inspection ABLE Inspection NOT Inspection ABLE Inspection NOTABLE ABLE Class 1 in HCA Class 2 in HCA Class 3 in HCA Class 4 in HCA in HCA subTotal Class 1 in MCA Class 2 in MCA Class 3 in MCA Class 4 in MCA in MCA subTotal Class 1 not in HCA or MCA Class 2 not in HCA or MCA Class 3 not in HCA or MCA Class 4 not in HCA or MCA not in HCA or MCA subTotal Total Form PHMSA F 7100.2-1 (rev 3-2022) Pg.42 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 1.39 MAOP > PT>_ 1.25 1.25 MAOP > PT >_ 1.1 1.1 MAOP > PT or No MAOP MAOP PT Miles Internal Miles Internal Miles Internal Miles Internal Miles Internal Miles Location Inspection Inspection NOT Inspection Inspection NOT Inspection Internal ABLE ABLE ABLE ABLE ABLE Inspection NOT ABLE Class 1 in HCA 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 3 in HCA 0.4 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 in HCA subTotal 0.4 0 0 0 0 0 Class 1 in MCA Class 2 in MCA Class 3 in MCA Class 4 in MCA in MCA subTotal Class 1 not in HCA or 0 0 0 0 0 MCA 1.6 Class 2 not in HCA or 0 0 0 0 0 MCA Class 3 not in HCA or 0 0 0 0 0 MCA Class 4 not in HCA or 0 0 0 0 0 MCA not in HCA or MCA 0 0 0 0 0 subTotal 1.6 Total 2 0 0 0 0 0 PT>_ 1.5 MAOP Total Total Miles Internal 2 Ins ection ABLE 1.5 MAOP > PT>_ 1.39 Total Miles Internal 0 MAOP Total Inspection NOT ABLE 1.39 > PT>_ 1.25 MAOP 2 Grand Total 2 Total 1.25 MAOP > PT>_ 1.1 0 1.1 MAOP > PT or No PT Total Grand Total ill Form PHMSA F 7100.2-1 (rev 3-2022) Pg.43 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part T— HCA Miles by Determination Method and Risk Model Type INTRASTATE IDAHO Risk Model Type Miles HCA Miles HCA Total Method 1 Method 2 Subject Matter Expert (SME) 0 0.4 0.4 Relative Risk 0 0 0 Quantitative 0 0 0 Probabilistic 0 0 0 Scenario-Based 0 0 0 Other describe: 0 0 0 Total 0 0.4 0.4 PARTS H, I, J, K, L, M, P, Q, R, S, and T The data reported in these PARTS applies to: (select only one) 0 Interstate pipelines/pipeline facilities in the State of ® Intrastate pipelines/pipeline facilities in the State of MARYLAND PART H-MILES OF TRANSMISSION PIPE BY NOMINAL PIPE SIZE(NPS) INTRASTATE MARYLAND NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 1.2 0 0 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Onshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 1.2 Total Miles of Onshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg.44 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Offshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Offshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg.45 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART I - MILES OF GATHERING PIPE BY NOMINAL PIPE SIZE (NPS) INTRASTATE MARYLAND NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore Type A 0 0 0 0 0 0 0 0 0 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type A Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type B 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type B Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type C 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Other Pipe Sizes Not Listed:0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type C Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less Offshore 22 24 26 28 30 32 34 36 38 Form PHMSA F 7100.2-1 (rev 3-2022) Pg.46 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 40 42 44 46 48 52 56 58 and over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Gathering Form PHMSA F 7100.2-1 (rev 3-2022) Pg.47 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART J — MILES OF PIPE BY DECADE INSTALLED INTRASTATE MARYLAND Decade Pipe Unknown Pre-40 1940-1949 1950-1959 1960-1969 1970-1979 1980-1989 Installed Transmission Onshore 0 0 0 0 0 0 0 Offshore Subtotal Transmission 0 0 0 0 0 0 0 Gathering Onshore Type A 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 Offshore Subtotal Gathering 0 0 0 0 0 0 0 Total Miles 0 0 0 0 0 0 0 Decade Pipe 1990-1999 2000-2009 2010-2019 2020-2029 Total Miles Installed Transmission Onshore 0 0 1.2 0 1.2 Offshore Subtotal Transmission 0 0 1.2 0 1.2 Gathering Onshore Type A 0 0 0 0 0 Onshore Type B 0 0 0 0 0 Onshore Type c 0 0 0 0 0 Offshore Subtotal Gathering 1 0 10 10 0 10 Total Miles 0 0 1.2 0 1.2 Form PHMSA F 7100.2-1 (rev 3-2022) Pg.48 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART K-MILES OF TRANSMISSION PIPE BY SPECIFIED MINIMUM YIELD STRENGTH INTRASTATE MARYLAND CLASS LOCATION Total Miles ONSHORE Class I Class 2 Class 3 Class 4 Steel pipe Less than 20%SMYS 0 0 0 0 0 Steel pipe Greater than or equal to 0 0 0 0 0 20%SMYS but less than 30%SMYS Steel pipe Greater than or equal to 30%SMYS but less than or equal to 0 0 1.2 0 1.2 0 SMYS Steel pipe Greater than 40%SMYS 0 0 0 0 0 but less than or equal to 50%SMYS Steel pipe Greater than 50%SMYS 0 0 0 0 0 but less than or equal to 60%SMYS Steel pipe Greater than 60%SMYS 0 0 0 0 0 but less than or equal to 72%SMYS Steel pipe Greater than 72%SMYS 0 0 0 0 0 but less than or equal to 80%SMYS Steel pipe Greater than 80%SMYS 0 0 0 0 0 Steel pipe Unknown percent of SMYS 0 0 0 0 0 All Non-Steel pipe 0 0 0 0 0 Onshore Totals 0 0 1.2 0 1.2 OFFSHORE Class I Steel pipe Less than or equal to 50% SMYS Steel pipe Greater than 50%SMYS but less than or egual to 0 SMYS Steel pipe Greater than 72%SMYS Steel Pipe Unknown percent of SMYS All non-steel pipe Offshore Total Total Miles 0 1.2 Form PHMSA F 7100.2-1 (rev 3-2022) Pg.49 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART L-MILES OF PIPE BY CLASS LOCATION INTRASTATE MARYLAND Class Location Class Class Total Location 3 Location 1 Class HCA §192 or 4 Miles or 2 Miles Class I Class 2 Class 3 Class 4 Location Miles .710 that are that are Miles Miles neither in neither in HCA nor in HCA nor in §192.710 §192.710 Transmission Onshore 0 0 1.2 0 1.2 0.2 0.02 0.98 Offshore 0 Subtotal 0 0 1.2 0 1.2 0.2 0.02 0.98 Transmission Gathering Onshore Type 0 0 0 0 A Onshore Type 0 0 0 0 B Onshore Type 0 0 C Offshore 0 0 Subtotal 0 0 0 0 0 Gathering Total Miles 0 0 1.2 0 1.2 0.2 0.02 0.98 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 50 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART M—FAILURES, LEAKS,AND REPAIRS INTRASTATE MARYLAND PART M1 —ALL LEAKS ELIMINATED/REPAIRED IN CALENDAR YEAR; INCIDENTS&FAILURES IN HCA SEGMENTS IN CALENDAR YEAR Transmission Leaks,and Failures Gathering Leaks Leaks Failures Offsh Onshore Leaks Offshore Leaks in HCA Onshore Leaks ore Cause Segment Leaks s class Class 1 3&4 non- & Non- Type Type HCA MCA HCA non- HCA HCA Type A B C &non- HCA MCA &non-MCA External Corrosion 0 0 0 0 0 0 0 0 Internal Corrosion 0 0 0 0 0 0 0 0 Stress Corrosion 0 0 0 0 0 0 0 0 Cracking Manufacturing 0 0 0 0 0 0 0 0 Construction 0 0 0 0 0 0 0 0 Equipment 0 0 0 0 0 0 0 0 Incorrect o 0 0 0 0 0 0 0 Operations Third Party Damage/Mechanical Damage Excavation 0 0 0 0 0 0 0 0 Damage Previous Damage(due to 0 0 0 0 0 0 0 0 Excavation Activity) Vandalism (includes all 0 0 0 0 0 0 0 0 Intentional Damage) Weather Related/Other Outside Force Natural Force 0 0 0 0 0 0 0 0 Damage(all) Other Outside Force Damage (excluding 0 0 0 0 0 0 0 0 Vandalism and all Intentional Damage) Other 0 1 0 1 0 0 1 0 1 0 1 0 1 0 Total 0 1 0 0 0 0 0 1 0 1 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 51 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Fxoires::3/31/2025 PART M2—KNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR Transmission 1 0 Gathering 0 PART M3—LEAKS ON FEDERAL LAND OR OCS REPAIRED OR SCHEDULED FOR REPAIR Transmission Gatherin Onshore Type A 0 Onshore 0 Onshore Type B 0 Onshore Type C 0 OCS 0 OCS 0 Subtotal Transmission 0 Subtotal Gathering 0 Total 0 PART P-MILES OF PIPE BY MATERIAL AND CORROSION PREVENTION STATUS INTRASTATE MARYLAND Steel Steel Cathodically Cathodically protected unprotected Coate Bare Coate Cast Wrought Plastic Other CoCornosite 2 Total Bare d d Iron Iron Miles Transmission Onshore 0 1.2 0 0 0 0 0 0 0 1.2 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 1.2 0 0 0 0 0 0 0 1.2 Transmission Gathering Onshore Type A 0 0 0 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 0 0 0 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 0 0 0 0 0 0 0 0 0 Gathering Total Miles 1 0 1 1.2 1 0 1 0 1 0 1 0 1 0 0 0 1.2 1 Use of Composite pipe requires PHMSA Special Permit or waiver from a State 2specify Other material(s): ; Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 52 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part Q- Gas Transmission Miles by MAOP Determination Method INTRASTATE MARYLAND by§192.619 and Other Methods (a)(1) (a)(2) (a)(3) (c) (d) OtherIncomp (a)(4 Incomp Incom Other(a)(1) ete (a)(2) Incom le (a)(3) Incom le (a)(4) Incomplet (c) lete (d) lete 1 Incompl Total Record Total to Total to Total a Records Total Total p ete s Records Records Record Record Total s s Records Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 1 (not in 0 0 0 0 0 0 0 HCA or MCA Class 2 (in o 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 2 (in o 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 2 (not in 0 0 0 0 HCA or wo No 0 MCA Class 3 (in 0 0 0.2 0 0 0 0 0 0 0 0 0 0 0 HCA Class 3 (in 0 0 0.02 0 0 0 0 0 0 0 0 0 0 0 MCA Class 3 (not in 0 0 0.98 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Class 4 (in o 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 4 (in o 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 4 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Total 0 0 1.2 0 0 0 0 0 0 0 0 0 0 0 by§192.624 Methods (c)(1)Total (c)(2)Total (c)(3)Total (c)(4)Total (c)(5)Total (c)(6)Total Class 1 in HCA 0 0 0 0 0 0 Class 1 (in MCA) 0 0 0 0 0 0 Class 1 (not in HCA or MCA) 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 2(in MCA) 0 0 1 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 53 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Ex ire 3/31/20 Class 2(not in HCA or MCA) 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 3(in MCA) 0 0 0 0 0 0 Class 3(not in HCA or MCA) 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 Class 4(in MCA) 0 0 0 0 0 0 Class 4(not in HCA or MCA) 1 0 1 0 1 0 1 0 1 0 1 0 Total 1 0 1 0 0 0 0 0 Total under 192.619(a), 192.619(c), 192.619(d) and 1.2 Other Total under 192.624 as allowed by 192.619 e 0 Grand Total 1.2 Sum of Total row for all "Incomplete Records" 0 columns Specify Other method(s): Class 1(in Class 1(in Class 1(not in MCA HCA) MCA) or HCA) Class 2(in Class 2(in Class 2(notin MCA HCA) MCA) or HCA) Class 3(in Class 3(in Class 3(not in MCA HCA) MCA) or HCA) Class 4(in Class 4(in Class 4(not in MCA HCA) MCA) or HCA) Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 54 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part R—Gas Transmission Miles by Pressure Test(PT)Range and Internal Inspection INTRASTATE MARYLAND PT>_ 1.50 MAOP 1.5 MAOP> PT>- 1.39 MAOP Miles Internal Miles Internal Miles Internal Miles Internal Location Inspection ABLE Inspection NOT Inspection ABLE Inspection NOTABLE ABLE Class 1 in HCA 0 0 0 0 Class 2 in HCA 0 0 0 0 Class 3 in HCA 0 0 0 0 Class 4 in HCA 0 0 0 0 in HCA subTotal 0 0 0 0 Class 1 in MCA 0 0 0 0 Class 2 in MCA 0 0 0 0 Class 3 in MCA 0 0 0 0 Class 4 in MCA 0 0 0 0 in MCA subTotal 0 0 0 0 Class 1 not in HCA or MCA 0 0 0 0 Class 2 not in HCA or MCA 0 0 0 0 Class 3 not in HCA or MCA 0 0 0 0 Class 4 not in HCA or MCA 0 0 0 0 not in HCA or MCA subTotal 0 0 0 0 Total 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 55 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 1.39 MAOP > PT>_ 1.25 1.25 MAOP > PT >_ 1.1 1.1 MAOP > PT or No MAOP MAOP PT Miles Internal Miles Internal Miles Internal Miles Internal Miles Internal Miles Location Inspection Inspection NOT Inspection Inspection NOT Inspection Internal ABLE ABLE ABLE ABLE ABLE Inspection NOT ABLE Class 1 in HCA 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 3 in HCA 0.2 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 in HCA subTotal 0.2 0 0 0 0 0 Class 1 in MCA 0 0 0 0 0 0 Class 2 in MCA 0.02 0 0 0 0 0 Class 3 in MCA 0 0 0 0 0 0 Class 4 in MCA 0 0 0 0 0 0 in MCA subTotal 0.02 0 0 0 0 0 Class 1 not in HCA or 0 0 0 0 0 MCA Class 2 not in HCA or 0 0 0 0 0 MCA Class 3 not in HCA or 0 0 0 0 0 MCA 0 98 Class 4 not in HCA or 0 0 0 0 0 MCA not in HCA or MCA 0.98 0 0 0 0 0 subTotal Total 1.2 0 0 0 0 0 PT>_ 1.5 MAOP Total 0 Total Miles Internal 1.2 Ins ection ABLE 1.5 MAOP > PT>_ 1.39 0 Total Miles Internal 0 MAOP Total Inspection NOT ABLE 1.39 > PT>_ 1.25 MAOP 1.2 Grand Total 1.2 Total 1.25 MAOP > PT>_ 1.1 0 1.1 MAOP > PT or No PT Total Grand Total Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 56 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part T— HCA Miles by Determination Method and Risk Model Type INTRASTATE MARYLAND Risk Model Type Miles HCA Miles HCA Total Method 1 Method 2 Subject Matter Expert (SME) 0 0.2 0.2 Relative Risk 0 0 0 Quantitative 0 0 0 Probabilistic 0 0 0 Scenario-Based 0 0 0 Other describe: 0 0 0 Total 0 0.2 0.2 PARTS H, I, J, K, L, M, P, Q, R, S, and T The data reported in these PARTS applies to: (select only one) 0 Interstate pipelines/pipeline facilities in the State of ® Intrastate pipelines/pipeline facilities in the State of NEW JERSEY PART H-MILES OF TRANSMISSION PIPE BY NOMINAL PIPE SIZE(NPS) INTRASTATE NEW JERSEY NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0.6 0 2 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Onshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 2.6 Total Miles of Onshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 57 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 NPS 4 6 8 10 12 14 16 18 20 or less 22 24 26 28 30 32 34 36 38 Offshore 58 and 40 42 44 46 48 52 56 over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 58 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART I - MILES OF GATHERING PIPE BY NOMINAL PIPE SIZE (NPS) INTRASTATE NEW JERSEY NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore Type A 0 0 0 0 0 0 0 0 0 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type A Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type B 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type B Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type C 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Other Pipe Sizes Not Listed:0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type C Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less Offshore 22 24 26 28 30 32 34 36 38 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 59 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 40 42 44 46 48 52 56 58 and over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Gathering Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 60 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART J — MILES OF PIPE BY DECADE INSTALLED INTRASTATE NEW JERSEY Decade Pipe Unknown Pre-40 1940-1949 1950-1959 1960-1969 1970-1979 1980-1989 Installed Transmission Onshore 0 0 0 0 0 0 0 Offshore Subtotal Transmission 0 0 0 0 0 0 0 Gathering Onshore Type A 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 Offshore Subtotal Gathering 0 0 0 0 0 0 0 Total Miles 0 0 0 0 0 0 0 Decade Pipe 1990-1999 2000-2009 2010-2019 2020-2029 Total Miles Installed Transmission Onshore 0.6 0 2 0 2.6 Offshore Subtotal Transmission 0.6 0 2 0 2.6 Gathering Onshore Type A 0 0 0 0 0 Onshore Type B 0 0 0 0 0 Onshore Type c 0 0 0 0 0 Offshore Subtotal Gathering 1 0 10 10 0 10 Total Miles 0.6 0 2 0 2.6 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 61 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART K-MILES OF TRANSMISSION PIPE BY SPECIFIED MINIMUM YIELD STRENGTH INTRASTATE NEW JERSEY CLASS LOCATION Total Miles ONSHORE Class I Class 2 Class 3 Class 4 Steel pipe Less than 20%SMYS 0 0 0 0 0 Steel pipe Greater than or equal to 0 0 0 0 0 20%SMYS but less than 30%SMYS Steel pipe Greater than or equal to 30%SMYS but less than or equal to 0.6 2 0 0 2.6 0 SMYS Steel pipe Greater than 40%SMYS 0 0 0 0 0 but less than or equal to 50%SMYS Steel pipe Greater than 50%SMYS 0 0 0 0 0 but less than or equal to 60%SMYS Steel pipe Greater than 60%SMYS 0 0 0 0 0 but less than or equal to 72%SMYS Steel pipe Greater than 72%SMYS 0 0 0 0 0 but less than or equal to 80%SMYS Steel pipe Greater than 80%SMYS 0 0 0 0 0 Steel pipe Unknown percent of SMYS 0 0 0 0 0 All Non-Steel pipe 0 0 0 0 0 Onshore Totals 0.6 2 0 0 2.6 OFFSHORE Class I Steel pipe Less than or equal to 50% SMYS Steel pipe Greater than 50%SMYS but less than or egual to 0 SMYS Steel pipe Greater than 72%SMYS Steel Pipe Unknown percent of SMYS All non-steel pipe Offshore Total Total Miles 0.6 2.6 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 62 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART L-MILES OF PIPE BY CLASS LOCATION INTRASTATE NEW JERSEY Class Location Class Class Total Location 3 Location 1 Class HCA §192 or 4 Miles or 2 Miles Class I Class 2 Class 3 Class 4 Location Miles .710 that are that are Miles Miles neither in neither in HCA nor in HCA nor in §192.710 §192.710 Transmission Onshore 0.6 2 0 0 2.6 0.4 2.2 Offshore 0 Subtotal 0.6 2 0 0 2 6 0.4 2.2 Transmission Gathering Onshore Type 0 0 0 0 A Onshore Type 0 0 0 0 B Onshore Type 0 0 C Offshore 0 0 Subtotal 0 0 0 0 0 Gathering Total Miles 0.6 2 0 0 2.6 0.4 2.2 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 63 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART M—FAILURES, LEAKS,AND REPAIRS INTRASTATE NEW JERSEY PART M1 —ALL LEAKS ELIMINATED/REPAIRED IN CALENDAR YEAR; INCIDENTS&FAILURES IN HCA SEGMENTS IN CALENDAR YEAR Transmission Leaks,and Failures Gathering Leaks Leaks Failures Offsh Onshore Leaks Offshore Leaks in HCA Onshore Leaks ore Cause Segment Leaks s class Class 1 3&4 non- & Non- Type Type HCA MCA HCA non- HCA HCA Type A B C &non- HCA MCA &non-MCA External Corrosion 0 0 0 0 0 0 0 0 Internal Corrosion 0 0 0 0 0 0 0 0 Stress Corrosion 0 0 0 0 0 0 0 0 Cracking Manufacturing 0 0 0 0 0 0 0 0 Construction 0 0 0 0 0 0 0 0 Equipment 0 0 0 0 0 0 0 0 Incorrect o 0 0 0 0 0 0 0 Operations Third Party Damage/Mechanical Damage Excavation 0 0 0 0 0 0 0 0 Damage Previous Damage(due to 0 0 0 0 0 0 0 0 Excavation Activity) Vandalism (includes all 0 0 0 0 0 0 0 0 Intentional Damage) Weather Related/Other Outside Force Natural Force 0 0 0 0 0 0 0 0 Damage(all) Other Outside Force Damage (excluding 0 0 0 0 0 0 0 0 Vandalism and all Intentional Damage) Other 0 1 0 1 0 0 1 0 1 0 1 0 1 0 Total 0 1 0 0 0 0 0 1 0 1 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 64 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Fxoires::3/31/2025 PART M2—KNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR Transmission I Gathering PART M3—LEAKS ON FEDERAL LAND OR OCS REPAIRED OR SCHEDULED FOR REPAIR Transmission Gatherin Onshore Type A Onshore Onshore Type B Onshore Type C OCS OCS Subtotal Transmission Subtotal Gathering Total PART P-MILES OF PIPE BY MATERIAL AND CORROSION PREVENTION STATUS INTRASTATE NEW JERSEY Steel Steel Cathodically Cathodically protected unprotected Coate Bare Coate Cast Wrought Plastic Other CoCornosite 2 Total Bare d d Iron Iron Miles Transmission Onshore 0 2.6 0 0 0 0 0 0 0 2.6 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 2.6 0 0 0 0 0 0 0 2.6 Transmission Gathering Onshore Type A 0 0 0 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 0 0 0 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 0 0 0 0 0 0 0 0 0 Gathering Total Miles 1 0 1 2.6 1 0 1 0 1 0 1 0 1 0 0 0 2.6 1 Use of Composite pipe requires PHMSA Special Permit or waiver from a State 2specify Other material(s): ; Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 65 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part Q- Gas Transmission Miles by MAOP Determination Method INTRASTATE NEW JERSEY by§192.619 and Other Methods (a)(1) (a)(2) (a)(3) (c) (d) OtherIncomp (a)(4 Incomp Incom Other(a)(1) ete (a)(2) Incom le (a)(3) Incom le (a)(4) Incomplet (c) lete (d) lete 1 Incompl Total Record Total to Total to Total a Records Total Total p ete s Records Records Record Record Total s s Records Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 1 (not in 0 0.6 0 0 0 0 0 HCA or MCA Class 2 (in 0 0 0.4 0 0 0 0 0 0 0 0 0 0 0 HCA Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 2 (not in 0 1.6 0 0 0 0 0 HCA or MCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 3 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 4 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Total 0 0 2.6 0 0 0 0 0 0 0 0 0 0 0 by§192.624 Methods (c)(1)Total (c)(2)Total (c)(3)Total (c)(4)Total (c)(5)Total (c)(6)Total Class 1 in HCA 0 0 0 0 0 0 Class 1 (in MCA) 0 0 0 0 0 0 Class 1 (not in HCA or MCA) 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 2(in MCA) 0 0 1 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 66 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Ex ire 3/31/20 Class 2(not in HCA or MCA) 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 3(in MCA) 0 0 0 0 0 0 Class 3(not in HCA or MCA) 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 Class 4(in MCA) 0 0 0 0 0 0 Class 4(not in HCA or MCA) 1 0 1 0 1 0 1 0 1 0 1 0 Total 1 0 1 0 0 0 0 0 Total under 192.619(a), 192.619(c), 192.619(d) and 2.6 Other Total under 192.624 as allowed by 192.619 e 0 Grand Total 2.6 Sum of Total row for all "Incomplete Records" 0 columns Specify Other method(s): Class 1(in Class 1(in Class 1(not in MCA HCA) MCA) or HCA) Class 2(in Class 2(in Class 2(notin MCA HCA) MCA) or HCA) Class 3(in Class 3(in Class 3(not in MCA HCA) MCA) or HCA) Class 4(in Class 4(in Class 4(not in MCA HCA) MCA) or HCA) Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 67 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part R—Gas Transmission Miles by Pressure Test(PT)Range and Internal Inspection INTRASTATE NEW JERSEY PT>_ 1.50 MAOP 1.5 MAOP> PT>- 1.39 MAOP Miles Internal Miles Internal Miles Internal Miles Internal Location Inspection ABLE Inspection NOT Inspection ABLE Inspection NOTABLE ABLE Class 1 in HCA 0 0 0 0 Class 2 in HCA 0 0 0 0 Class 3 in HCA 0 0 0 0 Class 4 in HCA 0 0 0 0 in HCA subTotal 0 0 0 0 Class 1 in MCA 0 0 0 0 Class 2 in MCA 0 0 0 0 Class 3 in MCA 0 0 0 0 Class 4 in MCA 0 0 0 0 in MCA subTotal 0 0 0 0 Class 1 not in HCA or MCA 0 0 0 0 Class 2 not in HCA or MCA 0 0 0 0 Class 3 not in HCA or MCA 0 0 0 0 Class 4 not in HCA or MCA 0 0 0 0 not in HCA or MCA subTotal 0 0 0 0 Total 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 68 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 1.39 MAOP > PT>_ 1.25 1.25 MAOP > PT >_ 1.1 1.1 MAOP > PT or No MAOP MAOP PT Miles Internal Miles Internal Miles Internal Miles Internal Miles Internal Miles Location Inspection Inspection NOT Inspection Inspection NOT Inspection Internal ABLE ABLE ABLE ABLE ABLE Inspection NOT ABLE Class 1 in HCA o 0 0 0 0 0 Class 2 in HCA 0.4 0 0 0 0 0 Class 3 in HCA o 0 0 0 0 0 Class 4 in HCA o 0 0 0 0 0 in HCA subTotal 0.4 0 0 0 0 0 Class 1 in MCA o 0 0 0 0 0 Class 2 in MCA o 0 0 0 0 0 Class 3 in MCA o 0 0 0 0 0 Class 4 in MCA o 0 0 0 0 0 in MCA subTotal 0 0 0 0 0 0 Class 1 not in HCA or 0 0 0 0 0 MCA o.6 Class 2 not in HCA or 0 0 0 0 0 MCA 1.6 Class 3 not in HCA or 0 0 0 0 0 MCA o Class 4 not in HCA or 0 0 0 0 0 MCA o not in HCA or MCA 0 0 0 0 0 subTotal 2.2 Total 2.6 0 0 0 0 0 PT>_ 1.5 MAOP Total o Total Miles Internal 2.6 Ins ection ABLE 1.5 MAOP > PT>_ 1.39 0 Total Miles Internal 0 MAOP Total Inspection NOT ABLE 1.39 > PT>_ 1.25 MAOP 2.6 Grand Total 2.6 Total 1.25 MAOP > PT>_ 1.1 0 1.1 MAOP > PT or No PT Total Grand Total Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 69 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part T— HCA Miles by Determination Method and Risk Model Type INTRASTATE NEW JERSEY Risk Model Type Miles HCA Miles HCA Total Method 1 Method 2 Subject Matter Expert (SME) 0 0.4 0.4 Relative Risk 0 0 0 Quantitative 0 0 0 Probabilistic 0 0 0 Scenario-Based 0 0 0 Other describe: 0 0 0 Total 0 0.4 0.4 PARTS H, I, J, K, L, M, P, Q, R, S, and T The data reported in these PARTS applies to: (select only one) 0 Interstate pipelines/pipeline facilities in the State of ® Intrastate pipelines/pipeline facilities in the State of OHIO PART H-MILES OF TRANSMISSION PIPE BY NOMINAL PIPE SIZE(NPS) INTRASTATE OHIO NPS 4 6 8 10 12 14 16 18 20 or less 0 0 5.6 0 2.35 0 0 0 2.27 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Onshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 10.22 Total Miles of Onshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 70 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 NPS 4 6 8 10 12 14 16 18 20 or less 22 24 26 28 30 32 34 36 38 Offshore 58 and 40 42 44 46 48 52 56 over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 71 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART I - MILES OF GATHERING PIPE BY NOMINAL PIPE SIZE (NPS) INTRASTATE OHIO NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 1 38 Onshore Type A 0 0 0 0 0 0 0 0 0 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles*0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type A Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type B 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type B Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type C 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Other Pipe Sizes Not Listed:0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type C Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less Offshore 22 24 26 28 30 32 34 36 38 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 72 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 40 42 44 46 48 52 56 58 and over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Gathering Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 73 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART J — MILES OF PIPE BY DECADE INSTALLED INTRASTATE OHIO Decade Pipe Unknown Pre-40 1940-1949 1950-1959 1960-1969 1970-1979 1980-1989 Installed Transmission Onshore 0 0 0 0 0 0 0 Offshore Subtotal Transmission 0 0 0 0 0 0 0 Gathering Onshore Type A 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 Offshore Subtotal Gathering 0 0 0 0 0 0 0 Total Miles 0 0 0 0 0 0 0 Decade Pipe 1990-1999 2000-2009 2010-2019 2020-2029 Total Miles Installed Transmission Onshore 7.95 0 0 2.27 10.22 Offshore Subtotal Transmission 7.95 0 0 2.27 10.22 Gathering Onshore Type A 0 0 0 0 0 Onshore Type B 0 0 0 0 0 Onshore Type c 0 0 0 0 0 Offshore Subtotal Gathering 1 0 10 10 0 10 Total Miles 7.95 0 0 2.27 10.22 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 74 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART K-MILES OF TRANSMISSION PIPE BY SPECIFIED MINIMUM YIELD STRENGTH INTRASTATE OHIO CLASS LOCATION Total Miles ONSHORE Class I Class 2 Class 3 Class 4 Steel pipe Less than 20%SMYS 2.3 4.85 0.8 0 7.95 Steel pipe Greater than or equal to 0 0 0 0 0 20%SMYS but less than 30%SMYS Steel pipe Greater than or equal to 30%SMYS but less than or equal to 2.27 0 0 0 2.27 0 SMYS Steel pipe Greater than 40%SMYS 0 0 0 0 0 but less than or equal to 50%SMYS Steel pipe Greater than 50%SMYS 0 0 0 0 0 but less than or equal to 60%SMYS Steel pipe Greater than 60%SMYS 0 0 0 0 0 but less than or equal to 72%SMYS Steel pipe Greater than 72%SMYS 0 0 0 0 0 but less than or equal to 80%SMYS Steel pipe Greater than 80%SMYS 0 0 0 0 0 Steel pipe Unknown percent of SMYS 0 0 0 0 0 All Non-Steel pipe 0 0 0 0 0 Onshore Totals 4.57 4.85 0.8 0 10.22 OFFSHORE Class I Steel pipe Less than or equal to 50% SMYS Steel pipe Greater than 50%SMYS but less than or egual to 0 SMYS Steel pipe Greater than 72%SMYS Steel Pipe Unknown percent of SMYS All non-steel pipe Offshore Total Total Miles 4.57 10.22 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 75 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART L-MILES OF PIPE BY CLASS LOCATION INTRASTATE OHIO Class Location Class Class Total Location 3 Location 1 Class HCA §192 or 4 Miles or 2 Miles Class I Class 2 Class 3 Class 4 Location Miles .710 that are that are Miles Miles neither in neither in HCA nor in HCA nor in §192.710 §192.710 Transmission Onshore 4.57 4.85 0.8 0 10.22 0 0.8 9.42 Offshore 0 Subtotal 4.57 4.85 0.8 0 10.22 0 0.8 9.42 Transmission Gathering Onshore Type 0 0 0 0 A Onshore Type 0 0 0 0 B Onshore Type 0 0 C Offshore 0 Subtotal 0 0 0 0 0 Gathering Total Miles 4.57 4.85 0.8 0 10.22 0 0.8 9.42 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 76 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART M—FAILURES, LEAKS,AND REPAIRS INTRASTATE OHIO PART M1 —ALL LEAKS ELIMINATED/REPAIRED IN CALENDAR YEAR; INCIDENTS&FAILURES IN HCA SEGMENTS IN CALENDAR YEAR Transmission Leaks,and Failures Gathering Leaks Leaks Failures Offsh Onshore Leaks Offshore Leaks in HCA Onshore Leaks ore Cause Segment Leaks s class Class 1 3&4 non- & Non- Type Type HCA MCA HCA non- HCA HCA Type A B C &non- HCA MCA &non-MCA External Corrosion 0 0 0 0 0 0 0 0 Internal Corrosion 0 0 0 0 0 0 0 0 Stress Corrosion 0 0 0 0 0 0 0 0 Cracking Manufacturing 0 0 0 0 0 0 0 0 Construction 0 0 0 0 0 0 0 0 Equipment 0 0 0 0 0 0 0 0 Incorrect o 0 0 0 0 0 0 0 Operations Third Party Damage/Mechanical Damage Excavation 0 0 0 0 0 0 0 0 Damage Previous Damage(due to 0 0 0 0 0 0 0 0 Excavation Activity) Vandalism (includes all 0 0 0 0 0 0 0 0 Intentional Damage) Weather Related/Other Outside Force Natural Force 0 0 0 0 0 0 0 0 Damage(all) Other Outside Force Damage (excluding 0 0 0 0 0 0 0 0 Vandalism and all Intentional Damage) Other 0 1 0 1 0 0 1 0 1 0 1 0 1 0 Total 0 1 0 0 0 0 0 1 0 1 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 77 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Fxoires::3/31/2025 PART M2—KNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR Transmission I Gathering PART M3—LEAKS ON FEDERAL LAND OR OCS REPAIRED OR SCHEDULED FOR REPAIR Transmission Gatherin Onshore Type A Onshore Onshore Type B Onshore Type C OCS OCS Subtotal Transmission Subtotal Gathering Total PART P-MILES OF PIPE BY MATERIAL AND CORROSION PREVENTION STATUS INTRASTATE OHIO Steel Steel Cathodically Cathodically protected unprotected Coate Bare Coate Cast Wrought Plastic Other CoCornosite 2 Total Bare d d Iron Iron Miles Transmission Onshore 0 10.22 0 0 0 0 0 0 0 10.22 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 10.22 0 0 0 0 0 0 0 10.22 Transmission Gathering Onshore Type A 0 0 0 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 0 0 0 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 0 0 0 0 0 0 0 0 0 Gathering Total Miles 1 0 1 10.22 1 0 1 0 1 0 1 0 1 0 0 0 10.22 1 Use of Composite pipe requires PHMSA Special Permit or waiver from a State 2specify Other material(s): ; Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 78 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part Q- Gas Transmission Miles by MAOP Determination Method INTRASTATE OHIO by§192.619 and Other Methods (a)(1) (a)(2) (a)(3) (c) (d) OtherIncomp (a)(4 Incomp Incom Other(a)(1) ete (a)(2) Incom le (a)(3) Incom le (a)(4) Incomplet (c) lete (d) lete 1 Incompl Total Record Total to Total to Total a Records Total Total p ete s Records Records Record Record Total s s Records Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 1 (not in 0 4.57 0 0 0 0 0 HCA or MCA Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 2 (not in 0 4.85 0 0 0 0 0 HCA or MCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 3 (not in 0 0 0.8 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 4 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Total 0 0 10.22 0 0 0 0 0 0 0 0 0 0 0 by§192.624 Methods (c)(1)Total (c)(2)Total (c)(3)Total (c)(4)Total (c)(5)Total (c)(6)Total Class 1 in HCA 0 0 0 0 0 0 Class 1 (in MCA) 0 0 0 0 0 0 Class 1 (not in HCA or MCA) 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 2(in MCA) 0 0 1 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 79 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Ex ire 3/31/20 Class 2(not in HCA or MCA) 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 3(in MCA) 0 0 0 0 0 0 Class 3(not in HCA or MCA) 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 Class 4(in MCA) 0 0 0 0 0 0 Class 4(not in HCA or MCA) 1 0 1 0 1 0 1 0 1 0 1 0 Total 1 0 1 0 1 0 0 0 0 Total under 192.619(a), 192.619(c), 192.619(d) and 10.22 Other Total under 192.624 as allowed by 192.619 e 0 Grand Total 10.22 Sum of Total row for all "Incomplete Records" 0 columns Specify Other method(s): Class 1(in Class 1(in Class 1(not in MCA HCA) MCA) or HCA) Class 2(in Class 2(in Class 2(notin MCA HCA) MCA) or HCA) Class 3(in Class 3(in Class 3(not in MCA HCA) MCA) or HCA) Class 4(in Class 4(in Class 4(not in MCA HCA) MCA) or HCA) Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 80 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part R—Gas Transmission Miles by Pressure Test(PT)Range and Internal Inspection INTRASTATE OHIO PT>_ 1.50 MAOP 1.5 MAOP> PT>- 1.39 MAOP Miles Internal Miles Internal Miles Internal Miles Internal Location Inspection ABLE Inspection NOT Inspection ABLE Inspection NOTABLE ABLE Class 1 in HCA 0 0 0 0 Class 2 in HCA 0 0 0 0 Class 3 in HCA 0 0 0 0 Class 4 in HCA 0 0 0 0 in HCA subTotal 0 0 0 0 Class 1 in MCA 0 0 0 0 Class 2 in MCA 0 0 0 0 Class 3 in MCA 0 0 0 0 Class 4 in MCA 0 0 0 0 in MCA subTotal 0 0 0 0 Class 1 not in HCA or MCA 0 0 0 0 Class 2 not in HCA or MCA 0 0 0 0 Class 3 not in HCA or MCA 0 0 0 0 Class 4 not in HCA or MCA 0 0 0 0 not in HCA or MCA subTotal 0 0 0 0 Total 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 81 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 1.39 MAOP > PT>_ 1.25 1.25 MAOP > PT >_ 1.1 1.1 MAOP > PT or No MAOP MAOP PT Miles Internal Miles Internal Miles Internal Miles Internal Miles Internal Miles Location Inspection Inspection NOT Inspection Inspection NOT Inspection Internal ABLE ABLE ABLE ABLE ABLE Inspection NOT ABLE Class 1 in HCA 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 in HCA subTotal 0 0 0 0 0 0 Class 1 in MCA 0 0 0 0 0 0 Class 2 in MCA 0 0 0 0 0 0 Class 3 in MCA 0 0 0 0 0 0 Class 4 in MCA 0 0 0 0 0 0 in MCA subTotal 0 0 0 0 0 0 Class 1 not in HCA or 0 0 0 0 0 MCA 4.57 Class 2 not in HCA or 0 0 0 0 0 MCA 4.85 Class 3 not in HCA or 0. 0 0 0 0 0 MCA $ Class 4 not in HCA or 0 0 0 0 0 MCA not in HCA or MCA 10.22 0 0 0 0 0 subTotal Total 10.22 0 0 0 0 0 PT>_ 1.5 MAOP Total 0 Total Miles Internal 10.22 Ins ection ABLE 1.5 MAOP > PT>_ 1.39 0 Total Miles Internal 0 MAOP Total Inspection NOT ABLE 1.39 > PT>_ 1.25 MAOP 10.22 Grand Total 10.22 Total 1.25 MAOP > PT>_ 1.1 0 1.1 MAOP > PT or No PT Total Grand Total Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 82 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part T— HCA Miles by Determination Method and Risk Model Type INTRASTATE OHIO Risk Model Type Miles HCA Miles HCA Total Method 1 Method 2 Subject Matter Expert (SME) 0 0 0 Relative Risk 0 0 0 Quantitative 0 0 0 Probabilistic 0 0 0 Scenario-Based 0 0 0 Other describe: 0 0 0 Total 0 0 0 PARTS H, I, J, K, L, M, P, Q, R, S, and T The data reported in these PARTS applies to: (select only one) 0 Interstate pipelines/pipeline facilities in the State of ® Intrastate pipelines/pipeline facilities in the State of OKLAHOMA PART H-MILES OF TRANSMISSION PIPE BY NOMINAL PIPE SIZE(NPS) INTRASTATE OKLAHOMA NPS 4 6 8 10 12 14 16 18 20 or less 0 0 3.6 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Onshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 3.6 Total Miles of Onshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 83 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 NPS 4 6 8 10 12 14 16 18 20 or less 22 24 26 28 30 32 34 36 38 Offshore 58 and 40 42 44 46 48 52 56 over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 84 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART I - MILES OF GATHERING PIPE BY NOMINAL PIPE SIZE (NPS) INTRASTATE OKLAHOMA NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore Type A 0 0 0 0 0 0 0 0 0 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type A Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type B 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type B Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type C 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Other Pipe Sizes Not Listed:0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type C Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less Offshore 22 24 26 28 30 32 34 36 38 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 85 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 40 42 44 46 48 52 56 58 and over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Gathering Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 86 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART J — MILES OF PIPE BY DECADE INSTALLED INTRASTATE OKLAHOMA Decade Pipe Unknown Pre-40 1940-1949 1950-1959 1960-1969 1970-1979 1980-1989 Installed Transmission Onshore 0 0 0 0 0 0 3.6 Offshore Subtotal Transmission 0 0 0 0 0 0 3.6 Gathering Onshore Type A 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 Offshore Subtotal Gathering 0 0 0 0 0 0 0 Total Miles 0 0 0 0 0 0 3.6 Decade Pipe 1990-1999 2000-2009 2010-2019 2020-2029 Total Miles Installed Transmission Onshore 0 0 0 0 3.6 Offshore Subtotal Transmission 0 0 0 0 3.6 Gathering Onshore Type A 0 0 0 0 0 Onshore Type B 0 0 0 0 0 Onshore Type c 0 0 0 0 0 Offshore Subtotal Gathering 1 0 10 10 0 10 Total Miles 0 0 0 0 3.6 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 87 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART K-MILES OF TRANSMISSION PIPE BY SPECIFIED MINIMUM YIELD STRENGTH INTRASTATE OKLAHOMA CLASS LOCATION Total Miles ONSHORE Class I Class 2 Class 3 Class 4 Steel pipe Less than 20%SMYS 0 3.6 0 0 3.6 Steel pipe Greater than or equal to 0 0 0 0 0 20%SMYS but less than 30%SMYS Steel pipe Greater than or equal to 30%SMYS but less than or equal to 0 0 0 0 0 0 SMYS Steel pipe Greater than 40%SMYS 0 0 0 0 0 but less than or equal to 50%SMYS Steel pipe Greater than 50%SMYS 0 0 0 0 0 but less than or equal to 60%SMYS Steel pipe Greater than 60%SMYS 0 0 0 0 0 but less than or equal to 72%SMYS Steel pipe Greater than 72%SMYS 0 0 0 0 0 but less than or equal to 80%SMYS Steel pipe Greater than 80%SMYS 0 0 0 0 0 Steel pipe Unknown percent of SMYS 0 0 0 0 0 All Non-Steel pipe 0 0 0 0 0 Onshore Totals 0 3.6 0 0 3.6 OFFSHORE Class I Steel pipe Less than or equal to 50% SMYS Steel pipe Greater than 50%SMYS but less than or egual to 0 SMYS Steel pipe Greater than 72%SMYS Steel Pipe Unknown percent of SMYS All non-steel pipe Offshore Total Total Miles 0 3.6 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 88 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART L-MILES OF PIPE BY CLASS LOCATION INTRASTATE OKLAHOMA Class Location Class Class Total Location 3 Location 1 Class HCA §192 or 4 Miles or 2 Miles Class I Class 2 Class 3 Class 4 Location Miles .710 that are that are Miles Miles neither in neither in HCA nor in HCA nor in §192.710 §192.710 Transmission Onshore 0 3.6 0 0 3.6 3.6 Offshore 0 Subtotal 0 3.6 0 0 3.6 3.6 Transmission Gathering Onshore Type 0 0 0 0 A Onshore Type 0 0 0 0 B Onshore Type 0 0 C Offshore 0 Subtotal 0 0 0 0 0 Gathering Total Miles 0 3.6 0 0 3.6 3.6 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 89 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART M—FAILURES, LEAKS,AND REPAIRS INTRASTATE OKLAHOMA PART M1 —ALL LEAKS ELIMINATED/REPAIRED IN CALENDAR YEAR; INCIDENTS&FAILURES IN HCA SEGMENTS IN CALENDAR YEAR Transmission Leaks,and Failures Gathering Leaks Leaks Failures Offsh Onshore Leaks Offshore Leaks in HCA Onshore Leaks ore Cause Segment Leaks s class Class 1 3&4 non- & Non- Type Type HCA MCA HCA non- HCA HCA Type A B C &non- HCA MCA &non-MCA External Corrosion 0 0 0 0 0 0 0 0 Internal Corrosion 0 0 0 0 0 0 0 0 Stress Corrosion 0 0 0 0 0 0 0 0 Cracking Manufacturing 0 0 0 0 0 0 0 0 Construction 0 0 0 0 0 0 0 0 Equipment 0 0 0 0 0 0 0 0 Incorrect o 0 0 0 0 0 0 0 Operations Third Party Damage/Mechanical Damage Excavation 0 0 0 0 0 0 0 0 Damage Previous Damage(due to 0 0 0 0 0 0 0 0 Excavation Activity) Vandalism (includes all 0 0 0 0 0 0 0 0 Intentional Damage) Weather Related/Other Outside Force Natural Force 0 0 0 0 0 0 0 0 Damage(all) Other Outside Force Damage (excluding 0 0 0 0 0 0 0 0 Vandalism and all Intentional Damage) Other 0 1 0 1 0 0 1 0 1 0 1 0 1 0 Total 0 1 0 0 0 0 0 1 0 1 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 90 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Fxoires::3/31/2025 PART M2—KNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR Transmission I Gathering PART M3—LEAKS ON FEDERAL LAND OR OCS REPAIRED OR SCHEDULED FOR REPAIR Transmission Gatherin Onshore Type A Onshore Onshore Type B Onshore Type C OCS OCS Subtotal Transmission Subtotal Gathering Total PART P-MILES OF PIPE BY MATERIAL AND CORROSION PREVENTION STATUS INTRASTATE OKLAHOMA Steel Steel Cathodically Cathodically protected unprotected Coate Bare Coate Cast Wrought Plastic Other CoCornosite 2 Total Bare d d Iron Iron Miles Transmission Onshore 0 3.6 0 0 0 0 0 0 0 3.6 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 3.6 0 0 0 0 0 0 0 3.6 Transmission Gathering Onshore Type A 0 0 0 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 0 0 0 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 0 0 0 0 0 0 0 0 0 Gathering Total Miles 1 0 1 3.6 1 0 1 0 1 0 1 0 1 0 0 0 3.6 1 Use of Composite pipe requires PHMSA Special Permit or waiver from a State 2specify Other material(s): ; Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 91 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part Q- Gas Transmission Miles by MAOP Determination Method INTRASTATE OKLAHOMA by§192.619 and Other Methods (a)(1) (a)(2) (a)(3) (c) (d) OtherIncomp (a)(4 Incomp Incom Other(a)(1) ete (a)(2) Incom le (a)(3) Incom le (a)(4) Incomplet (c) lete (d) lete 1 Incompl Total Record Total to Total to Total a Records Total Total p ete s Records Records Record Record Total s s Records Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 1 (not in 0 0 0 0 0 0 0 HCA or MCA Class 2 (in o 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 2 (in o 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 2 (not in 0 3.6 0 0wo0 HCA or No MCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 3 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Class 4 (in o 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 4 (in o 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 4 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Total 0 0 3.6 0 0 0 0 0 0 0 0 0 0 0 by§192.624 Methods (c)(1)Total (c)(2)Total (c)(3)Total (c)(4)Total (c)(5)Total (c)(6)Total Class 1 in HCA 0 0 0 0 0 0 Class 1 (in MCA) 0 0 0 0 0 0 Class 1 (not in HCA or MCA) 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 2(in MCA) 0 0 1 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg.92 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Ex ire 3/31/20 Class 2(not in HCA or MCA) 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 3(in MCA) 0 0 0 0 0 0 Class 3(not in HCA or MCA) 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 Class 4(in MCA) 0 0 0 0 0 0 Class 4(not in HCA or MCA) 1 0 1 0 1 0 1 0 1 0 1 0 Total 1 0 1 0 0 0 0 0 Total under 192.619(a), 192.619(c), 192.619(d) and 3.6 Other Total under 192.624 as allowed by 192.619 e 0 Grand Total 3.6 Sum of Total row for all "Incomplete Records" 0 columns Specify Other method(s): Class 1(in Class 1(in Class 1(not in MCA HCA) MCA) or HCA) Class 2(in Class 2(in Class 2(notin MCA HCA) MCA) or HCA) Class 3(in Class 3(in Class 3(not in MCA HCA) MCA) or HCA) Class 4(in Class 4(in Class 4(not in MCA HCA) MCA) or HCA) Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 93 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part R—Gas Transmission Miles by Pressure Test(PT)Range and Internal Inspection INTRASTATE OKLAHOMA PT>_ 1.50 MAOP 1.5 MAOP> PT>- 1.39 MAOP Miles Internal Miles Internal Miles Internal Miles Internal Location Inspection ABLE Inspection NOT Inspection ABLE Inspection NOTABLE ABLE Class 1 in HCA 0 0 0 0 Class 2 in HCA 0 0 0 0 Class 3 in HCA 0 0 0 0 Class 4 in HCA 0 0 0 0 in HCA subTotal 0 0 0 0 Class 1 in MCA 0 0 0 0 Class 2 in MCA 0 0 0 0 Class 3 in MCA 0 0 0 0 Class 4 in MCA 0 0 0 0 in MCA subTotal 0 0 0 0 Class 1 not in HCA or MCA 0 0 0 0 Class 2 not in HCA or MCA 0 0 0 0 Class 3 not in HCA or MCA 0 0 0 0 Class 4 not in HCA or MCA 0 0 0 0 not in HCA or MCA subTotal 0 0 0 0 Total 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 94 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 1.39 MAOP > PT>_ 1.25 1.25 MAOP > PT >_ 1.1 1.1 MAOP > PT or No MAOP MAOP PT Miles Internal Miles Internal Miles Internal Miles Internal Miles Internal Miles Location Inspection Inspection NOT Inspection Inspection NOT Inspection Internal ABLE ABLE ABLE ABLE ABLE Inspection NOT ABLE Class 1 in HCA 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 in HCA subTotal 0 0 0 0 0 0 Class 1 in MCA 0 0 0 0 0 0 Class 2 in MCA 0 0 0 0 0 0 Class 3 in MCA 0 0 0 0 0 0 Class 4 in MCA 0 0 0 0 0 0 in MCA subTotal 0 0 0 0 0 0 Class 1 not in HCA or 0 0 0 0 0 MCA Class 2 not in HCA or 0 0 0 0 0 MCA 3.6 Class 3 not in HCA or 0 0 0 0 0 MCA Class 4 not in HCA or 0 0 0 0 0 MCA not in HCA or MCA 0 0 0 0 0 subTotal 3.6 Total 3.6 0 0 0 0 0 PT>_ 1.5 MAOP Total 0 Total Miles Internal 3.6 Ins ection ABLE 1.5 MAOP > PT>_ 1.39 0 Total Miles Internal 0 MAOP Total Inspection NOT ABLE 1.39 > PT>_ 1.25 MAOP 3.6 Grand Total 3.6 Total 1.25 MAOP > PT>_ 1.1 0 1.1 MAOP > PT or No PT Total Grand Total Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 95 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PARTS H, I, J, K, L, M, P, Q, R, S, and T The data reported in these PARTS applies to: (select only one) ® Interstate pipelines/pipeline facilities in the State of PENNSYLVANIA 17 Intrastate pipelines/pipeline facilities in the State of PART H-MILES OF TRANSMISSION PIPE BY NOMINAL PIPE SIZE(NPS) INTERSTATE PENNSYLVANIA NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 8.49 0 10.19 0 0 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Onshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 1-0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 18.68 Total Miles of Onshore Pipe—Transmission NPS 4 6 8 10 12 14 16 18 20 or less 22 24 26 28 30 32 34 36 38 Offshore 58 and 40 42 44 46 48 52 56 over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 96 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART I - MILES OF GATHERING PIPE BY NOMINAL PIPE SIZE (NPS) INTERSTATE PENNSYLVANIA NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore Type A 0 0 0 0 0 0 0 0 0 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type A Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type B 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type B Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type C 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Other Pipe Sizes Not Listed:0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type C Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less Offshore 22 24 26 28 30 32 34 36 38 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 97 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 40 42 44 46 48 52 56 58 and over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Gathering Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 98 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART J — MILES OF PIPE BY DECADE INSTALLED INTERSTATE PENNSYLVANIA Decade Pipe Unknown Pre-40 1940-1949 1950-1959 1960-1969 1970-1979 1980-1989 Installed Transmission Onshore 0 0 0 0 0 0 0 Offshore Subtotal Transmission 0 0 0 0 0 0 0 Gathering Onshore Type A 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 Offshore Subtotal Gathering 0 0 0 0 0 0 0 Total Miles 0 0 0 0 0 0 0 Decade Pipe 1990-1999 2000-2009 2010-2019 2020-2029 Total Miles Installed Transmission Onshore 0 0 18.68 0 18.68 Offshore Subtotal Transmission 0 0 18.68 0 18.68 Gathering Onshore Type A 0 0 0 0 0 Onshore Type B 0 0 0 0 0 Onshore Type c 0 0 0 0 0 Offshore Subtotal Gathering 1 0 10 10 0 10 Total Miles 0 0 18.68 0 18.68 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 99 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART K-MILES OF TRANSMISSION PIPE BY SPECIFIED MINIMUM YIELD STRENGTH INTERSTATE PENNSYLVANIA CLASS LOCATION Total Miles ONSHORE Class I Class 2 Class 3 Class 4 Steel pipe Less than 20%SMYS 0 0 0 0 0 Steel pipe Greater than or equal to 0 0 0 0 0 20%SMYS but less than 30%SMYS Steel pipe Greater than or equal to 30%SMYS but less than or equal to 2.79 0 0 0 2.79 0 SMYS Steel pipe Greater than 40%SMYS 8.49 0 0 0 8.49 but less than or equal to 50%SMYS Steel pipe Greater than 50%SMYS 0 0 0 0 0 but less than or equal to 60%SMYS Steel pipe Greater than 60%SMYS 7.4 0 0 0 7.4 but less than or equal to 72%SMYS Steel pipe Greater than 72%SMYS 0 0 0 0 0 but less than or equal to 80%SMYS Steel pipe Greater than 80%SMYS 0 0 0 0 0 Steel pipe Unknown percent of SMYS 0 0 0 0 0 All Non-Steel pipe 0 0 0 0 0 Onshore Totals 18.68 0 0 0 18.68 OFFSHORE Class I Steel pipe Less than or equal to 50% SMYS Steel pipe Greater than 50%SMYS but less than or egual to 0 SMYS Steel pipe Greater than 72%SMYS Steel Pipe Unknown percent of SMYS All non-steel pipe Offshore Total Total Miles 18.68 18.68 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 100 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART L-MILES OF PIPE BY CLASS LOCATION INTERSTATE PENNSYLVANIA Class Location Class Class Total Location 3 Location 1 Class HCA §192 or 4 Miles or 2 Miles Class I Class 2 Class 3 Class 4 Location Miles .710 that are that are Miles Miles neither in neither in HCA nor in HCA nor in §192.710 §192.710 Transmission Onshore 18.68 0 0 0 18.68 18.68 Offshore 0 Subtotal 18.68 0 0 0 18.68 18.68 Transmission Gathering Onshore Type 0 0 0 0 A Onshore Type 0 0 0 0 B Onshore Type 0 0 C Offshore 0 Subtotal 0 0 0 0 0 Gathering Total Miles 18.68 0 0 0 18.68 18.68 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 101 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART M—FAILURES, LEAKS,AND REPAIRS INTERSTATE PENNSYLVANIA PART M1 —ALL LEAKS ELIMINATED/REPAIRED IN CALENDAR YEAR; INCIDENTS&FAILURES IN HCA SEGMENTS IN CALENDAR YEAR Transmission Leaks,and Failures Gathering Leaks Leaks Failures Offsh Onshore Leaks Offshore Leaks in HCA Onshore Leaks ore Cause Segment Leaks s class Class 1 3&4 non- & Non- Type Type HCA MCA HCA non- HCA HCA Type A B C &non- HCA MCA &non-MCA External Corrosion 0 0 0 0 0 0 Internal Corrosion 0 0 0 0 0 0 Stress Corrosion 0 0 0 0 0 0 Cracking Manufacturing 0 0 0 0 0 0 Construction 0 0 0 0 0 0 Equipment 0 0 0 0 0 0 Incorrect o 0 0 0 0 0 Operations Third Party Damage/Mechanical Damage Excavation 0 0 0 0 0 0 Damage Previous Damage(due to 0 0 0 0 0 0 Excavation Activity) Vandalism (includes all 0 0 0 0 0 0 Intentional Damage) Weather Related/Other Outside Force Natural Force 0 0 0 0 0 0 Damage(all) Other Outside Force Damage (excluding o 0 0 0 0 0 Vandalism and all Intentional Damage) Other o 1 0 0 1 0 1 0 1 0 Total 0 0 0 0 1 0 1 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 102 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Fxoires::3/31/2025 PART M2—KNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR Transmission I Gathering PART M3—LEAKS ON FEDERAL LAND OR OCS REPAIRED OR SCHEDULED FOR REPAIR Transmission Gatherin Onshore Type A Onshore Onshore Type B Onshore Type C OCS OCS Subtotal Transmission Subtotal Gathering Total PART P-MILES OF PIPE BY MATERIAL AND CORROSION PREVENTION STATUS INTERSTATE PENNSYLVANIA Steel Steel Cathodically Cathodically protected unprotected Coate Bare Coate Cast Wrought Plastic Other CoCornosite 2 Total Bare d d Iron Iron Miles Transmission Onshore 0 18.68 0 0 0 0 0 0 0 18.68 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 18.68 0 0 0 0 0 0 0 18.68 Transmission Gathering Onshore Type A 0 0 0 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 0 0 0 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 0 0 0 0 0 0 0 0 0 Gathering Total Miles 1 0 1 18.68 1 0 1 0 1 0 1 0 1 0 0 0 18.68 1 Use of Composite pipe requires PHMSA Special Permit or waiver from a State 2specify Other material(s): ; Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 103 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part Q- Gas Transmission Miles by MAOP Determination Method INTERSTATE PENNSYLVANIA by§192.619 and Other Methods (a)(1) (a)(2) (a)(3) (c) (d) OtherIncomp (a)(4 Incomp Incom Other(a)(1) ete (a)(2) Incom le (a)(3) Incom le (a)(4) Incomplet (c) lete (d) lete 1 Incompl Total Record Total to Total to Total a Records Total Total p ete s Records Records Record Record Total s s Records Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 1 (not in 0 18.68 0 0 0 0 0 HCA or MCA Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 2 (not in 0 0 0 0 0 0 0 HCA or MCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 3 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 4 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Total 0 0 18.68 0 0 0 0 0 0 0 0 0 0 0 by§192.624 Methods (c)(1)Total (c)(2)Total (c)(3)Total (c)(4)Total (c)(5)Total (c)(6)Total Class 1 in HCA 0 0 0 0 0 0 Class 1 (in MCA) 0 0 0 0 0 0 Class 1 (not in HCA or MCA) 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 2(in MCA) 0 0 1 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 104 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Ex ire 3/31/20 Class 2(not in HCA or MCA) 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 3(in MCA) 0 0 0 0 0 0 Class 3(not in HCA or MCA) 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 Class 4(in MCA) 0 0 0 0 0 0 Class 4(not in HCA or MCA) 1 0 1 0 1 0 1 0 1 0 1 0 Total 1 0 1 0 1 0 0 0 0 Total under 192.619(a), 192.619(c), 192.619(d) and 18.68 Other Total under 192.624 as allowed by 192.619 e 0 Grand Total 18.68 Sum of Total row for all "Incomplete Records" 0 columns Specify Other method(s): Class 1(in Class 1(in Class 1(not in MCA HCA) MCA) or HCA) Class 2(in Class 2(in Class 2(notin MCA HCA) MCA) or HCA) Class 3(in Class 3(in Class 3(not in MCA HCA) MCA) or HCA) Class 4(in Class 4(in Class 4(not in MCA HCA) MCA) or HCA) Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 105 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part R—Gas Transmission Miles by Pressure Test(PT)Range and Internal Inspection INTERSTATE PENNSYLVANIA PT>_ 1.50 MAOP 1.5 MAOP> PT>- 1.39 MAOP Miles Internal Miles Internal Miles Internal Miles Internal Location Inspection ABLE Inspection NOT Inspection ABLE Inspection NOTABLE ABLE Class 1 in HCA 0 0 0 0 Class 2 in HCA 0 0 0 0 Class 3 in HCA 0 0 0 0 Class 4 in HCA 0 0 0 0 in HCA subTotal 0 0 0 0 Class 1 in MCA 0 0 0 0 Class 2 in MCA 0 0 0 0 Class 3 in MCA 0 0 0 0 Class 4 in MCA 0 0 0 0 in MCA subTotal 0 0 0 0 Class 1 not in HCA or MCA 0 0 0 0 Class 2 not in HCA or MCA 0 0 0 0 Class 3 not in HCA or MCA 0 0 0 0 Class 4 not in HCA or MCA 0 0 0 0 not in HCA or MCA subTotal 0 0 0 0 Total 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 106 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 1.39 MAOP > PT>_ 1.25 1.25 MAOP > PT >_ 1.1 1.1 MAOP > PT or No MAOP MAOP PT Miles Internal Miles Internal Miles Internal Miles Internal Miles Internal Miles Location Inspection Inspection NOT Inspection Inspection NOT Inspection Internal ABLE ABLE ABLE ABLE ABLE Inspection NOT ABLE Class 1 in HCA 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 in HCA subTotal 0 0 0 0 0 0 Class 1 in MCA 0 0 0 0 0 0 Class 2 in MCA 0 0 0 0 0 0 Class 3 in MCA 0 0 0 0 0 0 Class 4 in MCA 0 0 0 0 0 0 in MCA subTotal 0 0 0 0 0 0 Class 1 not in HCA or 0 0 0 0 0 MCA 1 s.6s Class 2 not in HCA or 0 0 0 0 0 MCA Class 3 not in HCA or 0 0 0 0 0 MCA Class 4 not in HCA or 0 0 0 0 0 MCA not in HCA or MCA 18.68 0 0 0 0 0 subTotal Total 18.68 0 0 0 0 0 PT>_ 1.5 MAOP Total 0 Total Miles Internal 18.68 Ins ection ABLE 1.5 MAOP > PT>_ 1.39 0 Total Miles Internal 0 MAOP Total Inspection NOT ABLE 1.39 > PT>_ 1.25 MAOP 18.68 Grand Total 18.68 Total 1.25 MAOP > PT>_ 1.1 0 1.1 MAOP > PT or No PT Total Grand Total Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 107 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part S—Gas Transmission Verification of Materials (192.607) INTERSTATE PENNSYLVANIA Location Miles 192.607 this Year 192.607 Number Test Locations this Year Class 1 in HCA 0 0 Class 2 in HCA 0 0 Class 3 in HCA 0 0 Class 4 in HCA 0 0 Class 1 in MCA 0 0 Class 2 in MCA 0 0 Class 3 in MCA 0 0 Class 4 in MCA 0 0 Class 1 not in HCA or MCA 0 0 Class 2 not in HCA or MCA 0 0 Class 3 not in HCA or MCA 0 0 Class 4 not in HCA or MCA 0 0 Part T— HCA Miles by Determination Method and Risk Model Type INTERSTATE PENNSYLVANIA Risk Model Type Miles HCA Miles HCA Total Method 1 Method 2 Subject Matter Expert (SME) 0 0 0 Relative Risk 0 0 0 Quantitative 0 0 0 Probabilistic 0 0 0 Scenario-Based 0 0 0 Other describe: 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 108 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Total 0 0 0 PARTS H, I, J, K, L, M, P, Q, R, S, and T The data reported in these PARTS applies to: (select only one) 13 Interstate pipelines/pipeline facilities in the State of ® Intrastate pipelines/pipeline facilities in the State of PENNSYLVANIA PART H-MILES OF TRANSMISSION PIPE BY NOMINAL PIPE SIZE(NPS) INTRASTATE PENNSYLVANIA NPS 4 6 8 10 12 14 16 18 20 or less 2.5 11.5 2.7 0 1.1 0 1.2 0 0 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Onshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 19 Total Miles of Onshore Pipe—Transmission NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Offshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Offshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 109 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART I - MILES OF GATHERING PIPE BY NOMINAL PIPE SIZE (NPS) INTRASTATE PENNSYLVANIA NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore Type A 0 0 0 0 0 0 0 0 0 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type A Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type B 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type B Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 2.1 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type C 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Other Pipe Sizes Not Listed:0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 2.1 Total Miles of Onshore Type C Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 Offshore 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 110 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 40 42 44F46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0; 0-0; 0-0; 0-0; 0-0; 0-0;0-0; 0 Total Miles of Offshore Pipe—Gathering Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 111 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART J — MILES OF PIPE BY DECADE INSTALLED INTRASTATE PENNSYLVANIA Decade Pipe Unknown Pre-40 1940-1949 1950-1959 1960-1969 1970-1979 1980-1989 Installed Transmission Onshore 1 0 0 0 0 0 0 Offshore Subtotal Transmission 1 0 0 0 0 0 0 Gathering Onshore Type A 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 Offshore Subtotal Gathering 0 0 0 0 0 0 0 Total Miles 1 0 0 0 0 0 0 Decade Pipe 1990-1999 2000-2009 2010-2019 2020-2029 Total Miles Installed Transmission Onshore 10.5 1.5 6 0 19 Offshore Subtotal Transmission 10.5 1.5 6 0 19 Gathering Onshore Type A 0 0 0 0 0 Onshore Type B 0 0 0 0 0 Onshore Type c 0 0 2.1 0 2.1 Offshore Subtotal Gathering 1 0 10 12.1 0 12.1 Total Miles 1 10.5 1.5 8.1 0 21.1 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 112 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART K-MILES OF TRANSMISSION PIPE BY SPECIFIED MINIMUM YIELD STRENGTH INTRASTATE PENNSYLVANIA CLASS LOCATION Total Miles ONSHORE Class I Class 2 Class 3 Class 4 Steel pipe Less than 20%SMYS 0 0 1 0 1 Steel pipe Greater than or equal to 8.3 5.8 0 0 14.1 20%SMYS but less than 30%SMYS Steel pipe Greater than or equal to 30%SMYS but less than or equal to 2.2 0 0 0 2.2 0 SMYS Steel pipe Greater than 40%SMYS 0 0 0 0 0 but less than or equal to 50%SMYS Steel pipe Greater than 50%SMYS 0 0 0 0 0 but less than or equal to 60%SMYS Steel pipe Greater than 60%SMYS 0 0 0 0 0 but less than or equal to 72%SMYS Steel pipe Greater than 72%SMYS 0 0 0 0 0 but less than or equal to 80%SMYS Steel pipe Greater than 80%SMYS 0 0 0 0 0 Steel pipe Unknown percent of SMYS 0 0 0 0 0 All Non-Steel pipe 0 1.7 0 0 1.7 Onshore Totals 10.5 7.5 1 0 19 OFFSHORE Class I Steel pipe Less than or equal to 50% 0 SMYS Steel pipe Greater than 50%SMYS 0 but less than or egual to 0 SMYS Steel pipe Greater than 72%SMYS 0 Steel Pipe Unknown percent of SMYS 0 All non-steel pipe 0 Offshore Total 0 Total Miles 10.5 19 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 113 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART L-MILES OF PIPE BY CLASS LOCATION INTRASTATE PENNSYLVANIA Class Location Class Class Total Location 3 Location 1 Class HCA §192 or 4 Miles or 2 Miles Class I Class 2 Class 3 Class 4 Location Miles .710 that are that are Miles Miles neither in neither in HCA nor in HCA nor in §192.710 §192.710 Transmission Onshore 10.5 7.5 1 0 19 19 Offshore 0 0 Transmission Subtotal 10.5 7.5 1 0 19 19 Gathering Onshore Type 0 0 0 0 A Onshore Type 0 0 0 0 B Onshore Type 2 1 2.1 C Offshore 0 0 Subtotal 21 0 0 0 2.1 Gathering Total Miles 12.6 7.5 1 0 21.1 19 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 114 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART M—FAILURES, LEAKS,AND REPAIRS INTRASTATE PENNSYLVANIA PART M1 —ALL LEAKS ELIMINATED/REPAIRED IN CALENDAR YEAR; INCIDENTS&FAILURES IN HCA SEGMENTS IN CALENDAR YEAR Transmission Leaks,and Failures Gathering Leaks Leaks Failures Offsh Onshore Leaks Offshore Leaks in HCA Onshore Leaks ore Cause Segment Leaks s class Class 1 3&4 non- & Non- Type Type HCA MCA HCA non- HCA HCA Type A B C &non- HCA MCA &non-MCA External Corrosion 0 0 0 0 0 0 0 0 0 0 0 Internal Corrosion 0 0 0 0 0 0 0 0 0 0 0 Stress Corrosion 0 0 0 0 0 0 0 0 0 0 0 Cracking Manufacturing 0 0 0 0 0 0 0 0 0 0 0 Construction 0 0 0 0 0 0 0 0 0 0 0 Equipment 0 0 0 0 0 0 0 0 0 0 0 Incorrect o 0 0 0 0 0 0 0 0 0 0 Operations Third Party Damage/Mechanical Damage Excavation 0 0 0 0 0 0 0 0 0 0 0 Damage Previous Damage(due to 0 0 0 0 0 0 0 0 0 0 0 Excavation Activity) Vandalism (includes all 0 0 0 0 0 0 0 0 0 0 0 Intentional Damage) Weather Related/Other Outside Force Natural Force 0 0 0 0 0 0 0 0 0 0 0 Damage(all) Other Outside Force Damage (excluding 0 0 0 0 0 0 0 0 0 0 0 Vandalism and all Intentional Damage) Other 0 1 0 1 0 0 0 1 0 0 1 0 1 0 1 0 0 Total 0 1 0 0 0 0 0 0 0 1 0 1 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 115 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Fxoires::3/31/2025 PART M2—KNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR Transmission I Gathering PART M3—LEAKS ON FEDERAL LAND OR OCS REPAIRED OR SCHEDULED FOR REPAIR Transmission Gatherin Onshore Type A Onshore Onshore Type B Onshore Type C OCS OCS Subtotal Transmission Subtotal Gathering Total PART P-MILES OF PIPE BY MATERIAL AND CORROSION PREVENTION STATUS INTRASTATE PENNSYLVANIA Steel Steel Cathodically Cathodically protected unprotected Coate Bare Coate Cast Wrought Plastic Other CoCornosite 2 Total Bare d d Iron Iron Miles Transmission Onshore 0 16.5 0 0 0 0 2.5 0 0 19 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 16.5 0 0 0 0 2.5 0 0 19 Transmission Gathering Onshore Type A 0 0 0 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 0 0 0 Onshore Type C 0 2.1 0 0 0 0 0 0 0 2.1 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 2.1 0 0 0 0 0 0 0 2.1 Gathering Total Miles 1 0 1 18.6 1 0 1 0 1 0 1 0 1 2.5 0 0 21.1 1 Use of Composite pipe requires PHMSA Special Permit or waiver from a State 2specify Other material(s): ; Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 116 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part Q- Gas Transmission Miles by MAOP Determination Method INTRASTATE PENNSYLVANIA by§192.619 and Other Methods (a)(1) (a)(2) (a)(3) (c) (d) OtherIncomp (a)(4 Incomp Incom Other(a)(1) ete (a)(2) Incom le (a)(3) Incom le (a)(4) Incomplet (c) lete (d) lete 1 Incompl Total Record Total to Total to Total a Records Total Total p ete s Records Records Record Record Total s s Records Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 1 (not in 0 10.5 0 0 0 0 0 HCA or MCA Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 2 (not in 0 7.5 0 0 0 0 0 HCA or MCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 3 (in 0 0 0.1 0 0 0 0 0 0 0 0 0 0 0 MCA Class 3 (not in 0 0 0.9 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 4 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Total 0 0 19 0 0 0 0 0 0 0 0 0 0 0 by§192.624 Methods (c)(1)Total (c)(2)Total (c)(3)Total (c)(4)Total (c)(5)Total (c)(6)Total Class 1 in HCA 0 0 0 0 0 0 Class 1 (in MCA) 0 0 0 0 0 0 Class 1 (not in HCA or MCA) 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 2(in MCA) 0 0 1 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 117 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Ex ire 3/31/20 Class 2(not in HCA or MCA) 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 3(in MCA) 0 0 0 0 0 0 Class 3(not in HCA or MCA) 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 Class 4(in MCA) 0 0 0 0 0 0 Class 4(not in HCA or MCA) 1 0 1 0 1 0 1 0 1 0 1 0 Total 1 0 1 0 0 0 0 0 Total under 192.619(a), 192.619(c), 192.619(d) and 19 Other Total under 192.624 as allowed by 192.619 e 0 Grand Total 19 Sum of Total row for all "Incomplete Records" 0 columns Specify Other method(s): Class 1(in Class 1(in Class 1(not in MCA HCA) MCA) or HCA) Class 2(in Class 2(in Class 2(notin MCA HCA) MCA) or HCA) Class 3(in Class 3(in Class 3(not in MCA HCA) MCA) or HCA) Class 4(in Class 4(in Class 4(not in MCA HCA) MCA) or HCA) Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 118 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part R—Gas Transmission Miles by Pressure Test(PT)Range and Internal Inspection INTRASTATE PENNSYLVANIA PT>_ 1.50 MAOP 1.5 MAOP> PT>- 1.39 MAOP Miles Internal Miles Internal Miles Internal Miles Internal Location Inspection ABLE Inspection NOT Inspection ABLE Inspection NOTABLE ABLE Class 1 in HCA 0 0 0 0 Class 2 in HCA 0 0 0 0 Class 3 in HCA 0 0 0 0 Class 4 in HCA 0 0 0 0 in HCA subTotal 0 0 0 0 Class 1 in MCA 0 0 0 0 Class 2 in MCA 0 0 0 0 Class 3 in MCA 0 0 0.1 0 Class 4 in MCA 0 0 0 0 in MCA subTotal 0 0 0.1 0 Class 1 not in HCA or MCA 0 0 9.5 1 Class 2 not in HCA or MCA 0 0 5.8 1.7 Class 3 not in HCA or MCA 0 0 0.9 0 Class 4 not in HCA or MCA 0 0 0 0 not in HCA or MCA subTotal 0 0 16.2 2.7 Total 0 0 16.3 2.7 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 119 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 1.39 MAOP > PT>_ 1.25 1.25 MAOP > PT >_ 1.1 1.1 MAOP > PT or No MAOP MAOP PT Miles Internal Miles Internal Miles Internal Miles Internal Miles Internal Miles Location Inspection Inspection NOT Inspection Inspection NOT Inspection Internal ABLE ABLE ABLE ABLE ABLE Inspection NOT ABLE Class 1 in HCA 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 in HCA subTotal 0 0 0 0 0 0 Class 1 in MCA 0 0 0 0 0 0 Class 2 in MCA 0 0 0 0 0 0 Class 3 in MCA 0 0 0 0 0 0 Class 4 in MCA 0 0 0 0 0 0 in MCA subTotal 0 0 0 0 0 0 Class 1 not in HCA or 0 0 0 0 0 MCA Class 2 not in HCA or 0 0 0 0 0 MCA Class 3 not in HCA or 0 0 0 0 0 MCA Class 4 not in HCA or 0 0 0 0 0 MCA not in HCA or MCA 0 0 0 0 0 subTotal 0 Total 0 0 0 0 0 0 PT>_ 1.5 MAOP Total 0 Total Miles Internal 16.3 Ins ection ABLE 1.5 MAOP > PT>_ 1.39 19 Total Miles Internal 2.7 MAOP Total Inspection NOT ABLE 1.39 > PT>_ 1.25 MAOP 0 Grand Total 19 Total 1.25 MAOP > PT>_ 1.1 0 1.1 MAOP > PT or No PT Total Grand Total ill Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 120 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part S—Gas Transmission Verification of Materials (192.607) INTRASTATE PENNSYLVANIA Location Miles 192.607 this Year 192.607 Number Test Locations this Year Class 1 in HCA 0 0 Class 2 in HCA 0 0 Class 3 in HCA 0 0 Class 4 in HCA 0 0 Class 1 in MCA 0 0 Class 2 in MCA 0 0 Class 3 in MCA 0 0 Class 4 in MCA 0 0 Class 1 not in HCA or MCA 0 0 Class 2 not in HCA or MCA 0 0 Class 3 not in HCA or MCA 0 0 Class 4 not in HCA or MCA 0 0 Part T— HCA Miles by Determination Method and Risk Model Type INTRASTATE PENNSYLVANIA Risk Model Type Miles HCA Miles HCA Total Method 1 Method 2 Subject Matter Expert (SME) 0 0 0 Relative Risk 0 0 0 Quantitative 0 0 0 Probabilistic 0 0 0 Scenario-Based 0 0 0 Other describe: 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 121 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Total 0 0 0 PARTS H, I, J, K, L, M, P, Q, R, S, and T The data reported in these PARTS applies to: (select only one) 13 Interstate pipelines/pipeline facilities in the State of ® Intrastate pipelines/pipeline facilities in the State of SOUTH CAROLINA PART H-MILES OF TRANSMISSION PIPE BY NOMINAL PIPE SIZE(NPS) INTRASTATE SOUTH CAROLINA NPS 4 6 8 10 12 14 16 18 20 or less 2.2 5.4 1.5 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Onshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 9.1 Total Miles of Onshore Pipe—Transmission NPS 4 6 8 10 12 14 16 18 20 or less 22 24 26 28 30 32 34 36 38 Offshore 58 and 40 42 44 46 48 52 56 over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 122 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART I - MILES OF GATHERING PIPE BY NOMINAL PIPE SIZE (NPS) INTRASTATE SOUTH CAROLINA NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore Type A 0 0 0 0 0 0 0 0 0 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles*0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type A Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type B 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type B Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type C 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Other Pipe Sizes Not Listed:0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type C Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less Offshore 22 24 26 28 30 32 34 36 38 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 123 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 40 42 44 46 48 52 56 58 and over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Gathering Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 124 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART J — MILES OF PIPE BY DECADE INSTALLED INTRASTATE SOUTH CAROLINA Decade Pipe Unknown Pre-40 1940-1949 1950-1959 1960-1969 1970-1979 1980-1989 Installed Transmission Onshore 0 0 0 0 0 0 0 Offshore Subtotal Transmission 0 0 0 0 0 0 0 Gathering Onshore Type A 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 Offshore Subtotal Gathering 0 0 0 0 0 0 0 Total Miles 0 0 0 0 0 0 0 Decade Pipe 1990-1999 2000-2009 2010-2019 2020-2029 Total Miles Installed Transmission Onshore 3.6 4 1.5 0 9.1 Offshore Subtotal Transmission 3.6 4 1.5 0 9.1 Gathering Onshore Type A 0 0 0 0 0 Onshore Type B 0 0 0 0 0 Onshore Type c 0 0 0 0 0 Offshore Subtotal Gathering 1 0 10 10 0 10 Total Miles 3.6 4 1.5 0 9.1 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 125 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART K-MILES OF TRANSMISSION PIPE BY SPECIFIED MINIMUM YIELD STRENGTH INTRASTATE SOUTH CAROLINA CLASS LOCATION Total Miles ONSHORE Class I Class 2 Class 3 Class 4 Steel pipe Less than 20%SMYS 0 0 0 0 0 Steel pipe Greater than or equal to 0 5.5 3.6 0 9.1 20%SMYS but less than 30%SMYS Steel pipe Greater than or equal to 30%SMYS but less than or equal to 0 0 0 0 0 0 SMYS Steel pipe Greater than 40%SMYS 0 0 0 0 0 but less than or equal to 50%SMYS Steel pipe Greater than 50%SMYS 0 0 0 0 0 but less than or equal to 60%SMYS Steel pipe Greater than 60%SMYS 0 0 0 0 0 but less than or equal to 72%SMYS Steel pipe Greater than 72%SMYS 0 0 0 0 0 but less than or equal to 80%SMYS Steel pipe Greater than 80%SMYS 0 0 0 0 0 Steel pipe Unknown percent of SMYS 0 0 0 0 0 All Non-Steel pipe 0 0 0 0 0 Onshore Totals 0 5.5 3.6 0 9.1 OFFSHORE Class I Steel pipe Less than or equal to 50% SMYS Steel pipe Greater than 50%SMYS but less than or egual to 0 SMYS Steel pipe Greater than 72%SMYS Steel Pipe Unknown percent of SMYS All non-steel pipe Offshore Total Total Miles 0 9.1 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 126 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART L-MILES OF PIPE BY CLASS LOCATION INTRASTATE SOUTH CAROLINA Class Location Class Class Total Location 3 Location 1 Class HCA §192 or 4 Miles or 2 Miles Class I Class 2 Class 3 Class 4 Location Miles .710 that are that are Miles Miles neither in neither in HCA nor in HCA nor in §192.710 §192.710 Transmission Onshore 0 5.5 3.6 0 9.1 0.1 0.4 3.2 5.4 Offshore 0 0 Subtotal 0 5.5 3.6 0 9.1 0.1 0.4 3.2 5.4 Transmission Gathering Onshore Type 0 0 0 0 A Onshore Type 0 0 0 0 B Onshore Type 0 0 C Offshore 0 0 Subtotal 0 0 0 0 0 Gathering Total Miles 0 5.5 3.6 0 9.1 0.1 0.4 3.2 5.4 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 127 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART M—FAILURES, LEAKS,AND REPAIRS INTRASTATE SOUTH CAROLINA PART M1 —ALL LEAKS ELIMINATED/REPAIRED IN CALENDAR YEAR; INCIDENTS&FAILURES IN HCA SEGMENTS IN CALENDAR YEAR Transmission Leaks,and Failures Gathering Leaks Leaks Failures Offsh Onshore Leaks Offshore Leaks in HCA Onshore Leaks ore Cause Segment Leaks s class Class 1 3&4 non- & Non- Type Type HCA MCA HCA non- HCA HCA Type A B C &non- HCA MCA &non-MCA External Corrosion 0 0 0 0 0 0 0 0 Internal Corrosion 0 0 0 0 0 0 0 0 Stress Corrosion 0 0 0 0 0 0 0 0 Cracking Manufacturing 0 0 0 0 0 0 0 0 Construction 0 0 0 0 0 0 0 0 Equipment 0 0 0 0 0 0 0 0 Incorrect o 0 0 0 0 0 0 0 Operations Third Party Damage/Mechanical Damage Excavation 0 0 0 0 0 0 0 0 Damage Previous Damage(due to 0 0 0 0 0 0 0 0 Excavation Activity) Vandalism (includes all 0 0 0 0 0 0 0 0 Intentional Damage) Weather Related/Other Outside Force Natural Force 0 0 0 0 0 0 0 0 Damage(all) Other Outside Force Damage (excluding 0 0 0 0 0 0 0 0 Vandalism and all Intentional Damage) Other 0 1 0 1 0 0 1 0 1 0 1 0 1 0 Total 0 1 0 0 0 0 0 1 0 1 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 128 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Fxoires::3/31/2025 PART M2—KNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR Transmission I Gathering PART M3—LEAKS ON FEDERAL LAND OR OCS REPAIRED OR SCHEDULED FOR REPAIR Transmission Gatherin Onshore Type A Onshore Onshore Type B Onshore Type C OCS OCS Subtotal Transmission Subtotal Gathering Total PART P-MILES OF PIPE BY MATERIAL AND CORROSION PREVENTION STATUS INTRASTATE SOUTH CAROLINA Steel Steel Cathodically Cathodically protected unprotected Coate Bare Coate Cast Wrought Plastic Other CoCornosite 2 Total Bare d d Iron Iron Miles Transmission Onshore 0 9.1 0 0 0 0 0 0 0 9.1 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 9.1 0 0 0 0 0 0 0 9.1 Transmission Gathering Onshore Type A 0 0 0 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 0 0 0 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 0 0 0 0 0 0 0 0 0 Gathering Total Miles 1 0 1 9.1 1 0 1 0 1 0 1 0 1 0 0 0 9.1 1 Use of Composite pipe requires PHMSA Special Permit or waiver from a State 2specify Other material(s): ; Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 129 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part Q- Gas Transmission Miles by MAOP Determination Method INTRASTATE SOUTH CAROLINA by§192.619 and Other Methods (a)(1) (a)(2) (a)(3) (c) (d) OtherIncomp (a)(4 Incomp Incom Other(a)(1) ete (a)(2) Incom le (a)(3) Incom le (a)(4) Incomplet (c) lete (d) lete 1 Incompl Total Record Total to Total to Total a Records Total Total p ete s Records Records Record Record Total s s Records Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 1 (not in 0 0 0 0 0 0 0 HCA or MCA Class 2 (in 0 0 0.1 0 0 0 0 0 0 0 0 0 0 0 HCA Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 2 (not in 0 5.4 0 0 0 0 0 HCA or MCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 3 (not in 0 0 3.6 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 4 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Total 0 0 9.1 0 0 0 0 0 0 0 0 0 0 0 by§192.624 Methods (c)(1)Total (c)(2)Total (c)(3)Total (c)(4)Total (c)(5)Total (c)(6)Total Class 1 in HCA 0 0 0 0 0 0 Class 1 (in MCA) 0 0 0 0 0 0 Class 1 (not in HCA or MCA) 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 2(in MCA) 0 0 1 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 130 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Ex ire 3/31/20 Class 2(not in HCA or MCA) 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 3(in MCA) 0 0 0 0 0 0 Class 3(not in HCA or MCA) 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 Class 4(in MCA) 0 0 0 0 0 0 Class 4(not in HCA or MCA) 1 0 1 0 1 0 1 0 1 0 1 0 Total 1 0 1 0 0 0 0 0 Total under 192.619(a), 192.619(c), 192.619(d) and 9.1 Other Total under 192.624 as allowed by 192.619 e 0 Grand Total 9.1 Sum of Total row for all "Incomplete Records" 0 columns Specify Other method(s): Class 1(in Class 1(in Class 1(not in MCA HCA) MCA) or HCA) Class 2(in Class 2(in Class 2(notin MCA HCA) MCA) or HCA) Class 3(in Class 3(in Class 3(not in MCA HCA) MCA) or HCA) Class 4(in Class 4(in Class 4(not in MCA HCA) MCA) or HCA) Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 131 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part R—Gas Transmission Miles by Pressure Test(PT)Range and Internal Inspection INTRASTATE SOUTH CAROLINA PT>_ 1.50 MAOP 1.5 MAOP> PT>- 1.39 MAOP Miles Internal Miles Internal Miles Internal Miles Internal Location Inspection ABLE Inspection NOT Inspection ABLE Inspection NOTABLE ABLE Class 1 in HCA 0 0 0 0 Class 2 in HCA 0 0 0 0 Class 3 in HCA 0 0 0 0 Class 4 in HCA 0 0 0 0 in HCA subTotal 0 0 0 0 Class 1 in MCA 0 0 0 0 Class 2 in MCA 0 0 0 0 Class 3 in MCA 0 0 0 0 Class 4 in MCA 0 0 0 0 in MCA subTotal 0 0 0 0 Class 1 not in HCA or MCA 0 0 0 0 Class 2 not in HCA or MCA 0 0 0 0 Class 3 not in HCA or MCA 0 0 0 0 Class 4 not in HCA or MCA 0 0 0 0 not in HCA or MCA subTotal 0 0 0 0 Total 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 132 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 1.39 MAOP > PT>_ 1.25 1.25 MAOP > PT >_ 1.1 1.1 MAOP > PT or No MAOP MAOP PT Miles Internal Miles Internal Miles Internal Miles Internal Miles Internal Miles Location Inspection Inspection NOT Inspection Inspection NOT Inspection Internal ABLE ABLE ABLE ABLE ABLE Inspection NOT ABLE Class 1 in HCA 0 0 0 0 0 0 Class 2 in HCA 0.1 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 in HCA subTotal 0.1 0 0 0 0 0 Class 1 in MCA 0 0 0 0 0 0 Class 2 in MCA 0 0 0 0 0 0 Class 3 in MCA 0 0 0 0 0 0 Class 4 in MCA 0 0 0 0 0 0 in MCA subTotal 0 0 0 0 0 0 Class 1 not in HCA or 0 0 0 0 0 MCA Class 2 not in HCA or 0 0 0 0 0 MCA 5.4 Class 3 not in HCA or 0 0 0 0 0 MCA 3.6 Class 4 not in HCA or 0 0 0 0 0 MCA not in HCA or MCA 0 0 0 0 0 subTotal 9 Total 9.1 0 0 0 0 0 PT>_ 1.5 MAOP Total 0 Total Miles Internal 9.1 Ins ection ABLE 1.5 MAOP > PT>_ 1.39 0 Total Miles Internal 0 MAOP Total Inspection NOT ABLE 1.39 > PT>_ 1.25 MAOP 9.1 Grand Total 9.1 Total 1.25 MAOP > PT>_ 1.1 0 1.1 MAOP > PT or No PT Total Grand Total Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 133 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part S—Gas Transmission Verification of Materials (192.607) INTRASTATE SOUTH CAROLINA Location Miles 192.607 this Year 192.607 Number Test Locations this Year Class 1 in HCA 0 0 Class 2 in HCA 0 0 Class 3 in HCA 0 0 Class 4 in HCA 0 0 Class 1 in MCA 0 0 Class 2 in MCA 0 0 Class 3 in MCA 0 0 Class 4 in MCA 0 0 Class 1 not in HCA or MCA 0 0 Class 2 not in HCA or MCA 0 0 Class 3 not in HCA or MCA 0 0 Class 4 not in HCA or MCA 0 0 Part T— HCA Miles by Determination Method and Risk Model Type INTRASTATE SOUTH CAROLINA Risk Model Type Miles HCA Miles HCA Total Method 1 Method 2 Subject Matter Expert (SME) 0 0.1 0.1 Relative Risk 0 0 0 Quantitative 0 0 0 Probabilistic 0 0 0 Scenario-Based 0 0 0 Other describe: 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 134 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Total 0 0.1 0.1 PARTS H, I, J, K, L, M, P, Q, R, S, and T The data reported in these PARTS applies to: (select only one) ® Interstate pipelines/pipeline facilities in the State of WEST VIRGINIA 13 Intrastate pipelines/pipeline facilities in the State of PART H-MILES OF TRANSMISSION PIPE BY NOMINAL PIPE SIZE(NPS) INTERSTATE WEST VIRGINIA NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0.02 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 0 0 0 0 0 0 0 0 0 Onshore 58 and 40 42 44 46 48 52 56 over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;): 0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0.02 Total Miles of Onshore Pipe—Transmission NPS 4 6 8 10 12 14 16 18 20 or less 22 24 26 28 30 32 34 36 38 Offshore 58 and 40 42 44 46 48 52 56 over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Transmission Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 135 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART I - MILES OF GATHERING PIPE BY NOMINAL PIPE SIZE (NPS) INTERSTATE WEST VIRGINIA NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore Type A 0 0 0 0 0 0 0 0 0 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type A Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type B 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Additional Sizes and Miles(Size—Miles;):0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type B Pipe—Gathering NPS 4 6 8 10 12 14 16 18 20 or less 0 0 0 0 0 0 0 22 24 26 28 30 32 34 36 38 Onshore 0 0 0 0 0 0 0 0 0 Type C 40 42 44 46 48 52 56 58 and over 0 0 0 0 0 0 0 0 Other Pipe Sizes Not Listed:0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0;0-0; 0 Total Miles of Onshore Type C Pipe—Gathering NIPS 4 6 8 10 12 14 16 18 20 or less Offshore 22 24 26 28 30 32 34 36 38 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 136 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 40 42 44 46 48 52 56 58 and over Additional Sizes and Miles(Size—Miles;): Total Miles of Offshore Pipe—Gathering Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 137 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART J — MILES OF PIPE BY DECADE INSTALLED INTERSTATE WEST VIRGINIA Decade Pipe Unknown Pre-40 1940-1949 1950-1959 1960-1969 1970-1979 1980-1989 Installed Transmission Onshore 0 0 0 0 0 0 0 Offshore Subtotal Transmission 0 0 0 0 0 0 0 Gathering Onshore Type A 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 Offshore Subtotal Gathering 0 0 0 0 0 0 0 Total Miles 0 0 0 0 0 0 0 Decade Pipe 1990-1999 2000-2009 2010-2019 2020-2029 Total Miles Installed Transmission Onshore 0 0 0.02 0 0.02 Offshore Subtotal Transmission 0 0 0.02 0 0.02 Gathering Onshore Type A 0 0 0 0 0 Onshore Type B 0 0 0 0 0 Onshore Type c 0 0 0 0 0 Offshore Subtotal Gathering 1 0 10 10 0 10 Total Miles 1 0 0 0.02 0 0.02 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 138 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART K-MILES OF TRANSMISSION PIPE BY SPECIFIED MINIMUM YIELD STRENGTH INTERSTATE WEST VIRGINIA CLASS LOCATION Total Miles ONSHORE Class I Class 2 Class 3 Class 4 Steel pipe Less than 20%SMYS 0 0 0 0 0 Steel pipe Greater than or equal to 0 0 0 0 0 20%SMYS but less than 30%SMYS Steel pipe Greater than or equal to 30%SMYS but less than or equal to 0 0 0 0 0 0 SMYS Steel pipe Greater than 40%SMYS 0 0 0 0 0 but less than or equal to 50%SMYS Steel pipe Greater than 50%SMYS 0 0 0 0 0 but less than or equal to 60%SMYS Steel pipe Greater than 60%SMYS 0 0 0 0 0 but less than or equal to 72%SMYS Steel pipe Greater than 72%SMYS 0 0 0 0 0 but less than or equal to 80%SMYS Steel pipe Greater than 80%SMYS 0 0 0 0 0 Steel pipe Unknown percent of SMYS 0 0 0 0 0 All Non-Steel pipe 0.02 0 0 0 0.02 Onshore Totals 0.02 0 0 0 0.02 OFFSHORE Class I Steel pipe Less than or equal to 50% SMYS Steel pipe Greater than 50%SMYS but less than or egual to 0 SMYS Steel pipe Greater than 72%SMYS Steel Pipe Unknown percent of SMYS All non-steel pipe Offshore Total Total Miles 0.02 0.02 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 139 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART L-MILES OF PIPE BY CLASS LOCATION INTERSTATE WEST VIRGINIA Class Location Class Class Total Location 3 Location 1 Class HCA §192 or 4 Miles or 2 Miles Class I Class 2 Class 3 Class 4 Location Miles .710 that are that are Miles Miles neither in neither in HCA nor in HCA nor in §192.710 §192.710 Transmission Onshore 0.02 0 0 0 0.02 Offshore 0 Subtotal 0.02 0 0 0 0.02 Transmission Gathering Onshore Type 0 0 0 0 A Onshore Type 0 0 0 0 B Onshore Type 0 0 C Offshore 0 Subtotal 0 0 0 0 0 Gathering Total Miles 0.02 0 0 0 0.02 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 140 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 PART M—FAILURES, LEAKS,AND REPAIRS INTERSTATE WEST VIRGINIA PART M1 —ALL LEAKS ELIMINATED/REPAIRED IN CALENDAR YEAR; INCIDENTS&FAILURES IN HCA SEGMENTS IN CALENDAR YEAR Transmission Leaks,and Failures Gathering Leaks Leaks Failures Offsh Onshore Leaks Offshore Leaks in HCA Onshore Leaks ore Cause Segment Leaks s class Class 1 3&4 non- & Non- Type Type HCA MCA HCA non- HCA HCA Type A B C &non- HCA MCA &non-MCA External Corrosion 0 0 0 0 0 0 0 0 Internal Corrosion 0 0 0 0 0 0 0 0 Stress Corrosion 0 0 0 0 0 0 0 0 Cracking Manufacturing 0 0 0 0 0 0 0 0 Construction 0 0 0 0 0 0 0 0 Equipment 0 0 0 0 0 0 0 0 Incorrect o 0 0 0 0 0 0 0 Operations Third Party Damage/Mechanical Damage Excavation 0 0 0 0 0 0 0 0 Damage Previous Damage(due to 0 0 0 0 0 0 0 0 Excavation Activity) Vandalism (includes all 0 0 0 0 0 0 0 0 Intentional Damage) Weather Related/Other Outside Force Natural Force 0 0 0 0 0 0 0 0 Damage(all) Other Outside Force Damage (excluding 0 0 0 0 0 0 0 0 Vandalism and all Intentional Damage) Other 0 1 0 1 0 0 1 0 1 0 1 0 1 0 Total 0 1 0 0 0 0 0 1 0 1 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 141 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Fxoires::3/31/2025 PART M2—KNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR Transmission 1 0 Gathering 0 PART M3—LEAKS ON FEDERAL LAND OR OCS REPAIRED OR SCHEDULED FOR REPAIR Transmission Gatherin Onshore Type A 0 Onshore 0 Onshore Type B 0 Onshore Type C 0 OCS 0 OCS 0 Subtotal Transmission 0 Subtotal Gathering 0 Total 0 PART P-MILES OF PIPE BY MATERIAL AND CORROSION PREVENTION STATUS INTERSTATE WEST VIRGINIA Steel Steel Cathodically Cathodically protected unprotected Coate Bare Coate Cast Wrought Plastic Other CoCornosite 2 Total Bare d d Iron Iron Miles Transmission Onshore 0 0 0 0 0 0 0.02 0 0 0.02 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 0 0 0 0 0 0.02 0 0 0.02 Transmission Gathering Onshore Type A 0 0 0 0 0 0 0 0 0 0 Onshore Type B 0 0 0 0 0 0 0 0 0 0 Onshore Type C 0 0 0 0 0 0 0 0 0 0 Offshore 0 0 0 0 0 0 0 0 0 0 Subtotal 0 0 0 0 0 0 0 0 0 0 Gathering Total Miles 1 0 1 0 1 0 1 0 1 0 1 0 1 0.02 0 0 0.02 1 Use of Composite pipe requires PHMSA Special Permit or waiver from a State 2specify Other material(s): ; Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 142 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part Q- Gas Transmission Miles by MAOP Determination Method INTERSTATE WEST VIRGINIA by§192.619 and Other Methods (a)(1) (a)(2) (a)(3) (c) (d) OtherIncomp (a)(4 Incomp Incom Other(a)(1) ete (a)(2) Incom le (a)(3) Incom le (a)(4) Incomplet (c) lete (d) lete 1 Incompl Total Record Total to Total to Total a Records Total Total p ete s Records Records Record Record Total s s Records Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 1 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 1 (not in 0.02 0 0 0 0 0 0 HCA or MCA Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 2 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 2 (not in FA 0 0 0 0 0 0 HCA or MCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 3 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 3 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA Class 4 (in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MCA Class 4 (not in 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HCA or MCA Total 0.02 0 0 0 0 0 0 0 0 0 0 0 0 0 by§192.624 Methods (c)(1)Total (c)(2)Total (c)(3)Total (c)(4)Total (c)(5)Total (c)(6)Total Class 1 in HCA 0 0 0 0 0 0 Class 1 (in MCA) 0 0 0 0 0 0 Class 1 (not in HCA or MCA) 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 2(in MCA) 0 0 1 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 143 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Ex ire 3/31/20 Class 2(not in HCA or MCA) 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 3(in MCA) 0 0 0 0 0 0 Class 3(not in HCA or MCA) 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 Class 4(in MCA) 0 0 0 0 0 0 Class 4(not in HCA or MCA) 1 0 1 0 1 0 1 0 1 0 1 0 Total 1 0 1 0 0 0 0 0 Total under 192.619(a), 192.619(c), 192.619(d) and 0.02 Other Total under 192.624 as allowed by 192.619 e 0 Grand Total 0.02 Sum of Total row for all "Incomplete Records" 0 columns Specify Other method(s): Class 1(in Class 1(in Class 1(not in MCA HCA) MCA) or HCA) Class 2(in Class 2(in Class 2(notin MCA HCA) MCA) or HCA) Class 3(in Class 3(in Class 3(not in MCA HCA) MCA) or HCA) Class 4(in Class 4(in Class 4(not in MCA HCA) MCA) or HCA) Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 144 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part R—Gas Transmission Miles by Pressure Test(PT)Range and Internal Inspection INTERSTATE WEST VIRGINIA PT>_ 1.50 MAOP 1.5 MAOP> PT>- 1.39 MAOP Miles Internal Miles Internal Miles Internal Miles Internal Location Inspection ABLE Inspection NOT Inspection ABLE Inspection NOTABLE ABLE Class 1 in HCA 0 0 0 0 Class 2 in HCA 0 0 0 0 Class 3 in HCA 0 0 0 0 Class 4 in HCA 0 0 0 0 in HCA subTotal 0 0 0 0 Class 1 in MCA 0 0 0 0 Class 2 in MCA 0 0 0 0 Class 3 in MCA 0 0 0 0 Class 4 in MCA 0 0 0 0 in MCA subTotal 0 0 0 0 Class 1 not in HCA or MCA 0 0 0 0 Class 2 not in HCA or MCA 0 0 0 0 Class 3 not in HCA or MCA 0 0 0 0 Class 4 not in HCA or MCA 0 0 0 0 not in HCA or MCA subTotal 0 0 0 0 Total 0 0 0 0 Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 145 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 1.39 MAOP > PT>_ 1.25 1.25 MAOP > PT >_ 1.1 1.1 MAOP > PT or No MAOP MAOP PT Miles Internal Miles Internal Miles Internal Miles Internal Miles Internal Miles Location Inspection Inspection NOT Inspection Inspection NOT Inspection Internal ABLE ABLE ABLE ABLE ABLE Inspection NOT ABLE Class 1 in HCA 0 0 0 0 0 0 Class 2 in HCA 0 0 0 0 0 0 Class 3 in HCA 0 0 0 0 0 0 Class 4 in HCA 0 0 0 0 0 0 in HCA subTotal 0 0 0 0 0 0 Class 1 in MCA 0 0 0 0 0 0 Class 2 in MCA 0 0 0 0 0 0 Class 3 in MCA 0 0 0 0 0 0 Class 4 in MCA 0 0 0 0 0 0 in MCA subTotal 0 0 0 0 0 0 Class 1 not in HCA or 0 0 0 0 0 MCA o.02 Class 2 not in HCA or 0 0 0 0 0 MCA o Class 3 not in HCA or 0 0 0 0 0 MCA 0 Class 4 not in HCA or 0 0 0 0 0 MCA o not in HCA or MCA 0.02 0 0 0 0 0 subTotal Total 0.02 0 0 0 0 0 PT>_ 1.5 MAOP Total 0 Total Miles Internal 0.02 Ins ection ABLE 1.5 MAOP > PT>_ 1.39 0 Total Miles Internal 0 MAOP Total Inspection NOT ABLE 1.39 > PT>_ 1.25 MAOP 0.02 Grand Total 0.02 Total 1.25 MAOP > PT>_ 1.1 0 1.1 MAOP > PT or No PT Total Grand Total Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 146 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Part T— HCA Miles by Determination Method and Risk Model Type INTERSTATE WEST VIRGINIA Risk Model Type Miles HCA Miles HCA Total Method 1 Method 2 Subject Matter Expert (SME) 0 0 0 Relative Risk 0 0 0 Quantitative 0 0 0 Probabilistic 0 0 0 Scenario-Based 0 0 0 Other describe: 0 0 0 Total 0 0 0 For the designated Commodity Group, complete PART N one time for all of the pipelines and/or pipeline facilities included within this OPID, and then also PART O if any gas transmission pipeline facilities included within this OPID have Part L HCA mile value greater than zero. PART N-PREPARER SIGNATURE Andrea Shacklett (412)531-2440 Telephone Number Preparer's Name(type or print) Director of Regulatory Compliance Preparer's Title ashacklett@douglaspipeline.com Preparer's E-mail Address PART O-CERTIFYING SIGNATURE (applicable only to PARTs B,F,G,and 11111) (412)531-2440 Telephone Number Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 147 of 148 Reproduction of this form is permitted. Notice: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty Form Approved 3/1/2022 as provided in 49 USC 60122. OMB No.2137-0522 Expires::3/31/2025 Ryan Estabrook Senior Executive Officer's name certifying the information in PARTS B,F,G,and M as required by 49 U.S.C.60109(f) president Senior Executive Officer's title certifying the information in PARTs B,F,G,and M as required by 49 U.S.C.60109(f) restabrook@douglaspipeline.com Senior Executive Officer's E-mail Address Form PHMSA F 7100.2-1 (rev 3-2022) Pg. 148 of 148 Reproduction of this form is permitted.