Loading...
HomeMy WebLinkAboutAvista GD 2022 NOTICE: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty OMB No.2137-0629 as OMB NO:2137-0629 provided in 49 USC 60122. EXPIRATION DATE: 5/31/2024 Initial Date 03/06/2023 Submitted: U.S.Department of Transportation ANNUAL REPORT FOR CALENDAR Pipeline and Hazardous Materials YEAR 2022 Type ert Submission INITIAL Safety Administration GAS DISTRIBUTION SYSTEM Date Submitted: A federal agency may not conduct or sponsor,and a person is not required to respond to,nor shall a person be subject to a penalty for failure to comply with a collection of information subject to the requirements of the Paperwork Reduction Act unless that collection of information displays a current valid OMB Control Number. The OMB Control Number for this information collection is 2137-0629. Public reporting for this collection of information is estimated to be approximately 16 hours per response,including the time for reviewing instructions,gathering the data needed,and completing and reviewing the collection of information. All responses to this collection of information are mandatory. Send comments regarding this burden estimate or any other aspect of this collection of information,including suggestions for reducing this burden to:Information Collection Clearance Officer,PHMSA,Office of Pipeline Safety(PHP-30)1200 New Jersey Avenue,SE,Washington,D.C.20590. Important. Please read the separate instructions for completing this form before you begin. They clarify the information requested and provide specific examples. If you do not have a copy of the instructions,you can obtain one from the PHMSA Pipeline Safety Community Web Page at http://www.phmsa.dot.gov/pipeline/library/forms. PART A-OPERATOR INFORMATION (DOT use only 20230659-50959 1.Name of Operator AVISTA CORP 2.LOCATION OF OFFICE(WHERE ADDITIONAL INFORMATION MAY BE OBTAINED) 2a.Street Address 1411 East Mission Ave. 2b.City and County Spokane Spokane 2c.State WA 2d.Zip Code 99202 3.OPERATOR'S 5 DIGIT IDENTIFICATION NUMBER 31232 4.HEADQUARTERS NAME&ADDRESS 4a.Street Address 1411 East Mission(PO Box 3727,99220-3727) 4b.City and County Spokane 4c.State WA 4d.Zip Code 99202 5.STATE IN WHICH SYSTEM OPERATES ID 6.THIS REPORT PERTAINS TO THE FOLLOWING COMMODITY GROUP(Select Commodity Group based on the predominant gas carried and complete the report for that Commodity Group.File a separate report for each Commodity Group included in this OPID.) Natural Gas 7.THIS REPORT PERTAINS TO THE FOLLOWING TYPE OF OPERATOR(Select Type of Operator based on the structure of the company included in this OP/D for which this report is being submitted.): Investor Owned PART B-SYSTEM DESCRIPTION 1.GENERAL STEEL UNPROTECTED CATHODICALLY PLASTIC CAST/ DUCTILE COPPER OTHER RECONDITION SYSTEM PROTECTED WROUGHT IRON ED TOTAL IRON CAST IRON BARE COATED BARE COATED MILES OF 0 0 0 533.36 1652.055 0 0 0 0 0 2185.415 MAIN NO.OF 0 0 0 11667 75968 0 0 0 0 0 87635 SERVICES Form PHMSA F 7100.1-1 (rev 5-2021) Reproduction of this form is permitted Pg. 1 of 4 NOTICE: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty OMB No.2137-0629 as OMB NO:2137-0629 provided in 49 USC 60122. EXPIRATION DATE: 5/31/2024 2.MILES OF MAINS IN SYSTEM AT END OF YEAR MATERIAL UNKNOWN 2"OR LESS OVER 2" OVER 4" OVER 8" OVER 12" SYSTEM TOTALS THRU 4" THRU 8" THRU 12" STEEL 0 330.615 115.81 84.616 2.319 0 533.36 DUCTILE IRON 0 0 0 0 0 0 0 COPPER 0 0 0 0 0 0 0 CAST/WROUGHT 0 0 0 0 0 0 0 IRON PLASTIC PVC 0 0 0 0 0 0 0 PLASTIC PE 0 1231.434 294.029 126.592 0 0 1652.055 PLASTIC ABS 0 0 0 0 0 0 0 PLASTIC OTHER 0 0 0 0 0 0 0 OTHER 0 0 0 0 0 0 0 RECONDITIONED 0 0 0 0 0 0 0 CASTIRON TOTAL 0 1562.049 409.839 211.208 2.319 0 2185.415 Describe Other Material: 3.NUMBER OF SERVICES IN SYSTEM AT END OF YEAR AVERAGE SERVICE LENGTH:89 MATERIAL UNKNOWN 1"OR LESS OVER 1" OVER 2" OVER 4" OVER 8" SYSTEM TOTALS THRU 2" THRU 4" THRU 8" STEEL 202 11296 161 7 1 0 11667 DUCTILE IRON 0 0 0 0 0 0 0 COOPER 0 0 0 0 0 0 0 CAST/WROUGHT 0 0 0 0 0 0 0 IRON PLASTIC PVC 0 0 0 0 0 0 0 PLASTIC PE 404 75201 348 11 4 0 75968 PLASTIC ABS 0 0 0 0 0 0 0 PLASTIC OTHER 0 0 0 0 0 0 0 OTHER 0 0 0 0 0 0 0 RECONDITIONED 0 0 0 0 0 0 0 CASTIRON TOTAL 606 86497 509 18 5 0 87635 Describe Other Material: 4.MILES OF MAIN AND NUMBER OF SERVICES BY DECADE OF INSTALLATION UNKNOWN PRE-1940 1940-1949 1950-1959 1960-1969 1970-1979 1980-1989 1990-1999 2000-2009 2010-2019 2020-2029 TOTAL MILES OF 4.813 0 0 90.343 293.768 113.104 91.853 763.379 479.438 229.802 118.915 2185.415 MAIN NUMBER OF 1056 0 0 695 6340 4880 4995 29052 19317 15031 6269 87635 SERVICES PART C-TOTAL LEAKS AND HAZARDOUS LEAKS ELIMINATED/REPAIRED DURING THE YEAR Form PHMSA F 7100.1-1 (rev 5-2021) Reproduction of this form is permitted Pg. 2 of 4 NOTICE: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty OMB No.2137-0629 as OMB NO:2137-0629 provided in 49 USC 60122. EXPIRATION DATE: 5/31/2024 MAINS SERVICES CAUSE OF LEAK TOTAL HAZARDOUS TOTAL HAZARDOUS CORROSION FAILURE 0 0 0 0 NATURAL FORCE DAMAGE 0 0 15 8 EXCAVATION DAMAGE 29 29 111 111 OTHER OUTSIDE FORCE DAMAGE 1 0 30 22 PIPE,WELD OR JOINT FAILURE 8 2 12 4 EQUIPMENT FAILURE 4 3 99 4 INCORRECT OPERATIONS 1 0 3 0 OTHER CAUSE 0 0 5 5 NUMBER OF KNOWN SYSTEM LEAKS AT END OF YEAR SCHEDULED FOR REPAIR:28 NUMBER OF HAZARDOUS LEAKS INVOLVING A MECHANICAL JOINT FAILURE: 4 PART D-EXCAVATION DAMAGE PART E—EXCESS FLOW VALUE(EFV)AND SERVICE VALUE DATA 1.TOTAL NUMBER OF EXCAVATION DAMAGES BY APPARENT Total Number Of Services with EFV Installed During Year : 1450 ROOT CAUSE: 147 a. One-Call Notification Practices Not Sufficient: 76 Estimated Number Of Services with EFV In the System At End Of Year:22687 *Total Number of Manual Service Line Shut-off Valves Installed During Year: b. Locating Practices Not Sufficient: 20 64 c. Excavation Practices Not Sufficient: 44 d. Other: 7 *Estimated Number of Services with Manual Service Line Shut-off Valves Installed in the System at End of Year: 748 *These questions were added to the report in 2017. 2. NUBMER OF EXCAVATION TICKETS 38401 PART F-LEAKS ON FEDERAL LAND PART G—PERCENT OF UNACCOUNTED FOR GAS TOTAL NUMBER OF LEAKS ON FEDERAL LAND REPAIRED OR SCHEDULED TO REPAIR:0 UNACCOUNTED FOR GAS AS A PERCENT OF TOTAL CONSUMPTION FOR THE 12 MONTHS ENDING JUNE 30 OF THE REPORTING YEAR. [(PURCHASED GAS+PRODUCED GAS)MINUS(CUSTOMER USE+ COMPANY USE+APPROPRIATE ADJUSTMENTS)]DIVIDED BY (CUSTOMER USE+COMPANY USE+APPROPRIATE ADJUSTMENTS) TIMES 100 EQUALS PERCENT UNACCOUNTED FOR. FOR YEAR ENDING 6/30: 0.78% Form PHMSA F 7100.1-1 (rev 5-2021) Reproduction of this form is permitted Pg.3 of 4 NOTICE: This report is required by 49 CFR Part 191. Failure to report may result in a civil penalty OMB No.2137-0629 as OMB NO:2137-0629 provided in 49 USC 60122. EXPIRATION DATE: 5/31/2024 INFORMATION Part C-65 leaks were carried over from 2021:21 were repaired in 2022,22 were non-reportable once repaired, 19 were found not to be gas leaksonce investi ated,and 3 were carried over into 2023. PAR PREPARER Dylan Karaus Integrity Program Manager (509)495-4668 (Preparer's Name and Title) (Area Code and Telephone Number) dylan.karaus@avistacorp.com (000)000-0000 (Preparer's email address) (Area Code and Facsimile Number) Form PHMSA F 7100.1-1 (rev 5-2021) Reproduction of this form is permitted Pg. 4 of 4